Advertisement for orthosearch.org.uk
Results 481 - 500 of 2573
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 724 - 730
1 Jun 2008
Hartofilakidis G Georgiades G Babis GC Yiannakopoulos CK

We have evaluated the results of total hip replacement in patients with congenital hip disease using 46 cemented all-polyethylene Charnley acetabular components implanted with the cotyloplasty technique in 34 patients (group A), and compared them with 47 metal-backed cementless acetabular components implanted without bone grafting in 33 patients (group B). Patients in group A were treated between 1988 and 1993 and those in group B between 1990 and 1995. The mean follow-up for group A was 16.6 years (12 to 18) and the mean follow-up for group B was 13.4 years (10 to 16). Revision for aseptic loosening was undertaken in 15 hips (32.6%) in group A and in four hips (8.5%) in group B. When liner exchange was included, a total of 13 hips were revised in group B (27.7%). The mean polyethylene wear was 0.11 mm/yr (0.002 to 0.43) and 0.107 mm/yr (0 to 0.62) for groups A and B, respectively. Polyethylene wear in group A was associated with linear osteolysis, and in group B with expansile osteolysis. In patients with congenital hip disease, when 80% cover of the implant can be obtained, a cementless acetabular component appears to be acceptable and provides durable fixation. However, because of the type of osteolysis arising with these devices, early exchange of a worn liner is recommended before extensive bone loss makes revision surgery more complicated


The Journal of Bone & Joint Surgery British Volume
Vol. 63-B, Issue 1 | Pages 53 - 57
1 Feb 1981
Andrews H Arden G Hart G Owen J

Sixty-eight patients suffering deep infection from a consecutive series of 1746 total hip replacement operations are reviewed. The infection rate has been reduced considerably by improved technique and multiple antibiotic prophylaxis without the use of a special operation enclosure. Factors affecting deep infection are analysed and discussed


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 611 - 616
1 May 2015
Shin WC Lee SM Lee KW Cho HJ Lee JS Suh KT

There is no single standardised method of measuring the orientation of the acetabular component on plain radiographs after total hip arthroplasty. We assessed the reliability and accuracy of three methods of assessing anteversion of the acetabular component for 551 THAs using the PolyWare software and the methods of Liaw et al, and of Woo and Morrey. All measurements of the three methods had excellent intra- and inter-observer reliability. The values of the PolyWare software, which determines version of the acetabular component by edge detection were regarded as the reference standard. Although the PolyWare software and the method of Liaw et al were similarly precise, the method of Woo and Morrey was significantly less accurate (p < 0.001). The method of Liaw et al seemed to be more accurate than that of Woo and Morrey when compared with the measurements using the PolyWare software. If the qualified lateral radiograph was selected, anteversion measured using the method of Woo and Morrey was considered to be relatively reliable. Cite this article: Bone Joint J 2015; 97-B:611–16


The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 123 - 126
1 Jun 2019
El-Husseiny M Masri B Duncan C Garbuz DS

Aims

We investigated the long-term performance of the Tripolar Trident acetabular component used for recurrent dislocation in revision total hip arthroplasty. We assessed: 1) rate of re-dislocation; 2) incidence of complications requiring re-operation; and 3) Western Ontario and McMaster Universities osteoarthritis index (WOMAC) pain and functional scores.

Patients and Methods

We retrospectively identified 111 patients who had 113 revision tripolar constrained liners between 1994 and 2008. All patients had undergone revision hip arthroplasty before the constrained liner was used: 13 after the first revision, 17 after the second, 38 after the third, and 45 after more than three revisions. A total of 75 hips (73 patients) were treated with Tripolar liners due to recurrent instability with abductor deficiency, In addition, six patients had associated cerebral palsy, four had poliomyelitis, two had multiple sclerosis, two had spina bifida, two had spondyloepiphyseal dysplasia, one had previous reversal of an arthrodesis, and 21 had proximal femoral replacements. The mean age of patients at time of Tripolar insertions was 72 years (53 to 89); there were 69 female patients (two bilateral) and 42 male patients. All patients were followed up for a mean of 15 years (10 to 24). Overall, 55 patients (57 hips) died between April 2011 and February 2018, at a mean of 167 months (122 to 217) following their tripolar liner implantation. We extracted demographics, implant data, rate of dislocations, and incidence of other complications.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 6 | Pages 801 - 808
1 Aug 2004
Ostendorf M van Stel HF Buskens E Schrijvers AJP Marting LN Verbout AJ Dhert WJA

Our aim was to define the minimum set of patient-reported outcome measures which are required to assess health status after total hip replacement (THR). In 114 patients, we compared the pre-operative characteristics and sensitivity to change of the Oxford hip score (OHS), the Western Ontario and McMaster Universities osteoarthritis index (WOMAC), the SF-36, the SF-12 (derived from the SF-36), and the Euroqol questionnaire (EQ-5D). At one year after operation, very large effect sizes were found for the disease-specific measures, the physical domains of the SF-12, SF-36 and the EQ-5D. index. (1.3 to 3.0). Patients in Charnley class A showed more change in the OHS, WOMAC pain and function, the physical domains of the SF-36 and the EQ-5D. vas. (p < 0.05) compared with those in the Charnley B and C group. In this group, the effect size for the OHS more than doubled the effect sizes of WOMAC pain and physical function. We found high correlations and correlations of change between the OHS, the WOMAC, the physical domains of the SF-12 and the SF-36 and EQ-5D. index. The SF-36 and EQ-5D scores at one year after operation approached those of the general population. Furthermore, we found a binomial distribution of the pre-operative EQ-5D. index. score and a pre-operative discrepancy and post-operative agreement between the EQ-5D. vas. and EQ-5D. index. . We recommend the use of the OHS and SF-12 in the assessment of THR. The SF-36 may be used in circumstances when smaller changes in health status are investigated, for example in the follow-up of THR. The EQ-5D is useful in situations in which utility values are needed in order to calculate cost-effectiveness or quality-adjusted life years (QALYs), such as in the assessment of new techniques in THR


The Bone & Joint Journal
Vol. 102-B, Issue 5 | Pages 593 - 599
1 May 2020
Amanatullah DF Cheng RZ Huddleston III JI Maloney WJ Finlay AK Kappagoda S Suh GA Goodman SB

Aims

To establish the utility of adding the laboratory-based synovial alpha-defensin immunoassay to the traditional diagnostic work-up of a prosthetic joint infection (PJI).

Methods

A group of four physicians evaluated 158 consecutive patients who were worked up for PJI, of which 94 underwent revision arthroplasty. Each physician reviewed the diagnostic data and decided on the presence of PJI according to the 2014 Musculoskeletal Infection Society (MSIS) criteria (yes, no, or undetermined). Their initial randomized review of the available data before or after surgery was blinded to each alpha-defensin result and a subsequent randomized review was conducted with each result. Multilevel logistic regression analysis assessed the effect of having the alpha-defensin result on the ability to diagnose PJI. Alpha-defensin was correlated to the number of synovial white blood cells (WBCs) and percentage of polymorphonuclear cells (%PMN).


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 4 | Pages 539 - 542
1 Aug 1988
Gillespie W Frampton C Henderson R Ryan P

We have studied the incidence of tumours at remote sites following total hip replacement: 1,358 individuals have been followed up for 14,286 person-years after operation. In the decade following implantation the incidence of tumours of the lymphatic and haemopoietic systems was significantly greater, and that of cancer of the breast, colon, and rectum, significantly less than expected. Whilst the association might be due in part to an effect of the prosthetic implants, other mechanisms, particularly drug therapy, require consideration


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 2 | Pages 225 - 227
1 Feb 2008
Reigstad O Siewers P

An 86-year-old male presented with a loose total hip replacement (THR) ten years after implantation. At revision for anticipated aseptic loosening, watery pus was found in the joint and Bacille-Calmette-Guérin (BCG) was seen on culture. The bacterial strain was identified and was identical to the BCG used in the intravesicular treatment of superficial bladder carcinoma in this patient ten months earlier. After revision he received a full course of antituberculous treatment. The clinical and radiological results were excellent after follow-up for 30 months with his uncemented THR showing satisfactory incorporation. His inflammatory markers were normal and his Harris hip score was 95 points. The diagnosis of a tuberculous infection can be easily missed, but must be considered, especially if sterile pus is encountered


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1533 - 1535
1 Nov 2009
Salih S Currall VA Ward AJ Chesser TJS

Surgeons remain concerned that ceramic hip prostheses may fail catastrophically if either the head or the liner is fractured. We report two patients, each with a ceramic-on-ceramic total hip replacement who sustained high-energy trauma sufficient to cause a displaced periprosthetic acetabular fracture in whom the ceramic bearings survived intact. Simultaneous fixation of the acetabular fracture, revision of the cementless acetabular prosthesis and exchange of the ceramic bearings were performed successfully in both patients. Improved methods of manufacture of new types of alumina ceramic with a smaller grain size, and lower porosity, have produced much stronger bearings. Whether patients should be advised to restrict high-impact activities in order to protect these modern ceramic bearings from fracture remains controversial


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 5 | Pages 792 - 795
1 Sep 1997
Lehtimäki MY Lehto MUK Kautiainen H Savolainen HA Hämäläinen MMJ

Between 1971 and 1991 we performed Charnley low-friction arthroplasty (LFA) on 116 patients (186 hips) with juvenile chronic arthritis (JCA). We have now carried out a survival study, taking endpoints as revision, death or the end of the year 1993. Overall survival was 91.9% at ten years and 83.0% at 15 years. That of the femoral component was 95.6% at ten years and 91.9% at 15 years and of the acetabulum 95.0% and 87.8%, respectively. Only the use of steroids significantly impaired the survival. We therefore recommend the use of Charnley LFA for young patients with JCA requiring total hip replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 2 | Pages 168 - 171
1 Mar 1984
McElwaine J Colville J

A study of excision arthroplasty (Girdlestone's pseudarthrosis) for infected total hip replacements is presented. Twenty-two patients were reviewed with a minimum follow-up of one year. Reduction in pain was significant but the functional results were poor. Factors contributing to poor function were old age, poor medical condition and arthritis of the contralateral hip; these were in addition to the gross instability resulting from the pseudarthrosis. The patients were easily fatigued and dependent on external supports; calipers were found to be unacceptable. The symptoms after excision arthroplasty are compared with those before the original hip replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 2 | Pages 240 - 246
1 Mar 1997
Emery DFG Clarke HJ Grover ML

Fifty-seven Stanmore Total Hip replacements were implanted between 1974 and 1986 in patients under the age of 50 years. We have reviewed the results in terms of survivorship and function, and assessed the reasons for revision. Of the original 57, 22 (39%) have been revised at an average of 12 years from implantation, usually for aseptic loosening. Most of them had originally been implanted for osteoarthritis. Prostheses cemented with second-generation techniques have lasted significantly longer, and acetabular loosening emerged as a continuing problem. The overall survivorship was 90% at 10 years and 68% at 15 years. Cemented hip replacement appears to be a viable option in younger patients and the Stanmore implant is comparable with other cemented prostheses in this age group


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 198 - 206
1 Feb 2019
Salib CG Reina N Perry KI Taunton MJ Berry DJ Abdel MP

Aims

Concurrent hip and spine pathologies can alter the biomechanics of spinopelvic mobility in primary total hip arthroplasty (THA). This study examines how differences in pelvic orientation of patients with spine fusions can increase the risk of dislocation risk after THA.

Patients and Methods

We identified 84 patients (97 THAs) between 1998 and 2015 who had undergone spinal fusion prior to primary THA. Patients were stratified into three groups depending on the length of lumbar fusion and whether or not the sacrum was involved. Mean age was 71 years (40 to 87) and 54 patients (56%) were female. The mean body mass index (BMI) was 30 kg/m2 (19 to 45). Mean follow-up was six years (2 to 17). Patients were 1:2 matched to patients with primary THAs without spine fusion. Hazard ratios (HR) were calculated.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 168 - 172
1 Feb 2006
Mayr E de la Barrera JM Eller G Bach C Nogler M

In navigated total hip arthroplasty, the pelvis and the femur are tracked by means of rigid bodies fixed directly to the bones. Exact tracking throughout the procedure requires that the connection between the marker and bone remains stable in terms of translation and rotation. We carried out a cadaver study to compare the intra-operative stability of markers consisting of an anchoring screw with a rotational stabiliser and of pairs of pins and wires of different diameters connected with clamps. These devices were tested at different locations in the femur. Three human cadavers were placed supine on an operating table, with a reference marker positioned in the area of the greater trochanter. K-wires (3.2 mm), Steinman pins (3 and 4 mm), Apex pins (3 and 4 mm), and a standard screw were used as fixation devices. They were positioned medially in the proximal third of the femur, ventrally in the middle third and laterally in the distal portion. In six different positions of the leg, the spatial positions were recorded with a navigation system. Compared with the standard single screw, with the exception of the 3 mm Apex pins, the two-pin systems were associated with less movement of the marker and could be inserted less invasively. With the knee flexed to 90° and the dislocated hip rotated externally until the lower leg was parallel to the table (figure-four position), all the anchoring devices showed substantial deflection of 1.5° to 2.5°. The most secure area for anchoring markers was the lateral aspect of the femur


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 1 | Pages 56 - 62
1 Jan 1988
Johnsson R Thorngren K Persson B

During the 11-year-period from 1970 to 1980, 799 total hip arthroplasties with metal-on-plastic prostheses were performed for primary osteoarthritis. In all cases high viscosity cement was used, but not under pressure; acetabular cartilage was removed, but the femoral canal was not plugged. The rate of revision and risk factors were evaluated by survivorship analysis. The overall cumulative revision rates were 11%, 14% and 19% after 8, 10, and 14 years respectively. When prophylactic antibiotics were not used, there was a significant risk of revision for infection. The risk of revision for mechanical loosening of both the acetabular and femoral components was significantly increased for men, younger patients, and if a snap-fit prosthesis with a 35 mm head and short wedged stem was used. The survivorship findings were validated by multivariate statistical analysis


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 2 | Pages 258 - 263
1 Feb 2008
Parratte S Kilian P Pauly V Champsaur P Argenson JA

We have evaluated in vitro the accuracy of percutaneous and ultrasound registration as measured in terms of errors in rotation and version relative to the bony anterior pelvic plane in computer-assisted total hip replacement, and analysed the intra- and inter-observer reliability of manual or ultrasound registration. Four clinicians were asked to perform registration of the landmarks of the anterior pelvic plane on two cadavers. Registration was performed under four different conditions of acquisition. Errors in rotation were not significant. Version errors were significant with percutaneous methods (16.2°; p < 0.001 and 19.25° with surgical draping; p < 0.001), but not with the ultrasound acquisition (6.2°, p = 0.13). Intra-observer repeatability was achieved for all the methods. Inter-observer analysis showed acceptable agreement in the sagittal but not in the frontal plane. Ultrasound acquisition of the anterior pelvic plane was more reliable in vitro than the cutaneous digitisation currently used


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1458 - 1462
1 Nov 2015
Langlois J Atlan F Scemama C Courpied JP Hamadouche M

Most published randomised controlled trials which compare the rates of wear of conventional and cross-linked (XL) polyethylene (PE) in total hip arthroplasty (THA) have described their use with a cementless acetabular component. . We conducted a prospective randomised study to assess the rates of penetration of two distinct types of PE in otherwise identical cemented all-PE acetabular components. . A total of 100 consecutive patients for THA were randomised to receive an acetabular component which had been either highly XL then remelted or moderately XL then annealed. . After a minimum of eight years follow-up, 38 hips in the XL group and 30 hips in the annealed group had complete data (mean follow-up of 9.1 years (7.6 to 10.7) and 8.7 years (7.2 to 10.2), respectively). In the XL group, the steady state rate of penetration from one year onwards was -0.0002 mm/year (. sd. 0.108): in the annealed group it was 0.1382 mm/year (. sd. 0.129) (Mann–Whitney U test, p < 0.001). No complication specific to either material was recorded. These results show that the yearly linear rate of femoral head penetration can be significantly reduced by using a highly XLPE cemented acetabular component. Cite this article: Bone Joint J 2015;97-B:1458–62


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 9 | Pages 1201 - 1209
1 Sep 2011
Peng K Hsu W Shih H Hsieh C Huang T Hsu RW Chang P

In this study of 41 patients, we used proteomic, Western blot and immunohistochemical analyses to show that several reactive oxygen species scavenging enzymes are expressed differentially in patients with primary osteoarthritis and those with non-loosening and aseptic loosening after total hip replacement (THR). The patients were grouped as A (n = 16, primary THR), B (n = 10, fixed THR but requiring revision for polyethylene wear) and C (n = 15, requiring revision due to aseptic loosening) to verify the involvement of the identified targets in aseptic loosening. When compared with Groups A and B, Group C patients exhibited significant up-regulation of transthyretin and superoxide dismutase 3, but down-regulation of glutathione peroxidase 2 in their hip synovial fluids. Also, higher levels of superoxide dismutase 2 and peroxiredoxin 2, but not superoxide dismutase 1, catalase and glutathione perioxidase 1, were consistently detected in the hip capsules of Group C patients. We propose that dysregulated reactive oxygen species-related enzymes may play an important role in the pathogenesis and progression of aseptic loosening after THR


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 1 | Pages 93 - 98
1 Jan 1997
Britton AR Murray DW Bulstrode CJ McPherson K Denham RA

We have assessed the relative value of various outcome measures after THR, by the analysis of follow-up data from over 2000 patients. They had been reviewed clinically and radiologically six months after operation, at one year, and then every two years, some for 16 years. At each review their pain level, stiffness and opinion of progress were scored and a radiograph taken. We found that pain level was the most informative outcome as a predictor of revision and correlated well with the patients’ opinions. We made a comparison between the six types of implant in the series, using survival analysis and log-rank testing with different pain levels as endpoints. This analysis revealed differences which were not detected by survival analysis using the traditional endpoint of revision. We therefore recommend the use of different levels of pain as the main outcome measures after total hip replacement


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 3 | Pages 382 - 390
1 May 1998
Eggli S Pisan M Müller ME

To analyse the value and accuracy of preoperative planning for total hip replacement (THR) we digitised electronically and compared the hand-sketched preoperative plans with the pre- and postoperative radiographs of 100 consecutive primary THRs. The correct type of prosthesis was planned in 98%; the agreement between planned and actually used components was 92% on the femoral side and 90% on the acetabular side. The mean (± SD) absolute difference between the planned and actual position of the centre of rotation of the hip was 2.5 ± 1.1 mm vertically and 4.4 ± 2.1 mm horizontally. On average, the inclination of the acetabular component differed by 7 ± 2° and anteversion by 9 ± 3° from the preoperative plans. The mean postoperative leg-length difference was 0.3 ± 0.1 cm clinically and 0.2 ± 0.1 cm radiologically. More than 80% of intraoperative difficulties were anticipated. Preoperative planning is of significant value for the successful performance of THR