Advertisement for orthosearch.org.uk
Results 481 - 500 of 671
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 19 - 21
1 Nov 2012
Callaghan JJ Liu SS Haidukewych GJ

Options for the treatment of subcapital femoral neck fractures basically fall into two categories: internal fixation or arthroplasty (either hemiarthroplasty or total hip arthroplasty). Historically, the treatment option has been driven by a diagnosis-related approach (non-displaced neck fractures versus displaced neck fractures). More recently, the traditional paradigm has changed. Instead of a diagnosis-related approach, it has become more of a patient-related approach. Treatment options take in to consideration the patient’s age, functional demands, and individual risk profile. A simple algorithm can be helpful in terms of directing the treatment. Non-displaced fractures, regardless of age of the patient, should be treated with closed reduction and internal fixation. For displaced femoral neck fractures, the treatment differs depending on the age of the patient. The younger patient should be treated with urgent ORIF with the goal of an anatomic reduction. For displaced femoral neck fractures in the elderly, cognitive function should be determined. For those who are cognitively functioning, total hip arthroplasty appears to be the best option. In the cognitively dysfunctional, a bipolar hemiarthroplasty or a total hip arthroplasty with use of larger heads (32 mm or 36 mm) and/or constrained sockets are a viable option.


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 681 - 688
1 May 2015
Wagener ML de Vos MJ Hannink G van der Pluijm M Verdonschot N Eygendaal D

Unlinked, linked and convertible total elbow arthroplasties (TEAs) are currently available. This study is the first to report the clinical results of the convertible Latitude TEA. This was a retrospective study of a consecutive cohort of 63 patients (69 primary TEAs) with a mean age of 60 years (23 to 87). Between 2006 and 2008 a total of 19 men and 50 women underwent surgery. The mean follow-up was 43 months (8 to 84). The range of movement, function and pain all improved six months post-operatively and either continued to improve slightly or reached a plateau thereafter. The complication rate is similar to that reported for other TEA systems. No loosening was seen. Remarkable is the disengagement of the radial head component in 13 TEAs (31%) with a radial head component implanted.

Implantation of both the linked and the unlinked versions of the Latitude TEA results in improvement of function and decreased pain, and shows high patient satisfaction at mid-term follow-up.

Cite this article: Bone Joint J 2015; 97-B:681–8.


Bone & Joint 360
Vol. 2, Issue 5 | Pages 29 - 31
1 Oct 2013

The October 2013 Spine Roundup360 looks at: Standing straighter may reduce falls; Operative management of congenital kyphosis; Athletic discectomy; Lumbar spine stenosis worsens with time; Flexible stabilisation?: spinal stenosis revisited; Do epidural steroids cause spinal fractures?; Who does well with cervical myelopathy?; Secretly adverse to BMP-2?


Bone & Joint 360
Vol. 2, Issue 4 | Pages 12 - 15
1 Aug 2013

The August 2013 Foot & Ankle Roundup360 looks at: mobility, ankles and fractures; hindfoot nailing: not such a bad option after all?; little treatment benefit for blood injection in tendonitis; fixed bearing ankles successful in the short term; hindfoot motion following STAR ankle replacement; minimally invasive calcaneal fracture fixation?; pes planus in adolescents; and subluxing peroneals and groove deepening


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 398 - 404
1 Mar 2015
Fang C Lau TW Wong TM Lee HL Leung F

The spiral blade modification of the Dynamic Hip Screw (DHS) was designed for superior biomechanical fixation in the osteoporotic femoral head. Our objective was to compare clinical outcomes and in particular the incidence of loss of fixation.

In a series of 197 consecutive patients over the age of 50 years treated with DHS-blades (blades) and 242 patients treated with conventional DHS (screw) for AO/OTA 31.A1 or A2 intertrochanteric fractures were identified from a prospectively compiled database in a level 1 trauma centre. Using propensity score matching, two groups comprising 177 matched patients were compiled and radiological and clinical outcomes compared. In each group there were 66 males and 111 females. Mean age was 83.6 (54 to 100) for the conventional DHS group and 83.8 (52 to 101) for the blade group.

Loss of fixation occurred in two blades and 13 DHSs. None of the blades had observable migration while nine DHSs had gross migration within the femoral head before the fracture healed. There were two versus four implant cut-outs respectively and one side plate pull-out in the DHS group. There was no significant difference in mortality and eventual walking ability between the groups. Multiple logistic regression suggested that poor reduction (odds ratio (OR) 11.49, 95% confidence intervals (CI) 1.45 to 90.9, p = 0.021) and fixation by DHS (OR 15.85, 95%CI 2.50 to 100.3, p = 0.003) were independent predictors of loss of fixation.

The spiral blade design may decrease the risk of implant migration in the femoral head but does not reduce the incidence of cut-out and reoperation. Reduction of the fracture is of paramount importance since poor reduction was an independent predictor for loss of fixation regardless of the implant being used.

Cite this article: Bone Joint J 2015;97-B:398–404.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 104 - 108
1 Jan 2015
Bretherton CP Parker MJ

There has been extensive discussion about the effect of delay to surgery on mortality in patients sustaining a fracture of the hip. Despite the low level of evidence provided by many studies, a consensus has been accepted that delay of > 48 hours is detrimental to survival. The aim of this prospective observational study was to determine if early surgery confers a survival benefit at 30 days.

Between 1989 and 2013, data were prospectively collected on patients sustaining a fracture of the hip at Peterborough City Hospital. They were divided into groups according to the time interval between admission and surgery. These thresholds ranged from <  6 hours to between 49 and 72 hours. The outcome which was assessed was the 30-day mortality. Adjustment for confounders was performed using multivariate binary logistic regression analysis. In all, 6638 patients aged > 60 years were included.

Worsening American Society of Anaesthesiologists grade (p < 0.001), increased age (p <  0.001) and extracapsular fracture (p < 0.019) increased the risk of 30-day mortality.

Increasing mobility score (p = 0.014), mini mental test score (p < 0.001) and female gender (p = 0.014) improved survival. After adjusting for these confounders, surgery before 12 hours improved survival compared with surgery after 12 hours (p = 0.013). Beyond this the increasing delay to surgery did not significantly affect the 30-day mortality.

Cite this article: Bone Joint J 2015;97-B:104–8.


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 43 - 47
1 Nov 2014
Su EP Su SL

Surgical interventions consisting of internal fixation (IF) or total hip replacement (THR) are required to restore patient mobility after hip fractures. Conventionally, this decision was based solely upon the degree of fracture displacement. However, in the last ten years, there has been a move to incorporate patient characteristics into the decision making process. Research demonstrating that joint replacement renders superior functional results when compared with IF, in the treatment of displaced femoral neck fractures, has swayed the pendulum in favour of THR. However, a high risk of dislocation has always been the concern. Fortunately, there are newer technologies and alternative surgical approaches that can help reduce the risk of dislocation. The authors propose an algorithm for the treatment of femoral neck fractures: if minimally displaced, in the absence of hip joint arthritis, IF should be performed; if arthritis is present, or the fracture is displaced, then THR is preferred.

Cite this article: Bone Joint J 2014;96-B(11 Suppl A):43–7.


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 66 - 69
1 Nov 2014
Lombardi Jr AV Berend KR Adams JB

The common recommended treatment for infected total hip replacement is two-staged exchange including removal of all components. However, removal of well-fixed femoral stems can result in structural bone damage. We recently reported on an alternative treatment of partial two-stage exchange used in selected cases, in which a well-fixed femoral stem was left and only the acetabular component removed, the joint space was debrided thoroughly, an antibiotic-laden polymethylmethacrylate spacer was moulded using a bulb-type syringe and placed in the acetabulum, intravenous antibiotics were administered during the interval, and delayed re-implantation was performed. In 19 patients treated with this technique from January 2000 to January 2011, 89% were free of infection at a mean follow-up of four years (2 to 11). Since then, disposable silicone moulds have become available to fabricate spacers in separate femoral and head units. The head spacer mould, which incorporates various neck taper adapter options, greatly facilitates the technique of partial two-stage exchange. We report our early experience using disposable silicone head spacer moulds for partial two-stage exchange in seven patients with infected primary hip replacements.

Cite this article: Bone Joint J 2014;96-B(11 Suppl A):66–9


Bone & Joint 360
Vol. 3, Issue 6 | Pages 23 - 26
1 Dec 2014

The December 2014 Trauma Roundup360 looks at: infection and temporising external fixation; Vitamin C in distal radial fractures; DRAFFT: Cheap and cheerful Kirschner wires win out; femoral neck fractures not as stable as they might be; displaced sacral fractures give high morbidity and mortality; sanders and calcaneal fractures: a 20-year experience; bleeding and pelvic fractures; optimising timing for acetabular fractures; and tibial plateau fractures.


Bone & Joint 360
Vol. 4, Issue 5 | Pages 21 - 22
1 Oct 2015

The October 2015 Spine Roundup360 looks at: Traumatic spinal cord injury under the spotlight; The odontoid peg nonunion; Driving and spinal surgery; Drains and antibiotics post-spinal surgery; Vertebroplasty and kyphoplasty equally effective; Who will benefit from steroid injections?; Back pain following lumbar discectomy


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 960 - 965
1 Jul 2013
Försth P Michaëlsson K Sandén B

Whether to combine spinal decompression with fusion in patients with symptomatic lumbar spinal stenosis remains controversial. We performed a cohort study to determine the effect of the addition of fusion in terms of patient satisfaction after decompressive spinal surgery in patients with and without a degenerative spondylolisthesis.

The National Swedish Register for Spine Surgery (Swespine) was used for the study. Data were obtained for all patients in the register who underwent surgery for stenosis on one or two adjacent lumbar levels. A total of 5390 patients fulfilled the inclusion criteria and completed a two-year follow-up. Using multivariable models the results of 4259 patients who underwent decompression alone were compared with those of 1131 who underwent decompression and fusion. The consequence of having an associated spondylolisthesis in the operated segments pre-operatively was also considered.

At two years there was no significant difference in patient satisfaction between the two treatment groups for any of the outcome measures, regardless of the presence of a pre-operative spondylolisthesis. Moreover, the proportion of patients who required subsequent further lumbar surgery was also similar in the two groups.

In this large cohort the addition of fusion to decompression was not associated with an improved outcome.

Cite this article: Bone Joint J 2013;95-B:960–5.


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1485 - 1490
1 Nov 2014
Kim CW Seo SS Kim JH Roh SM Lee CR

The aim of this study was to find anatomical landmarks for rotational alignment of the tibial component in total knee replacement (TKR) in a CT-based study. Pre-operative CT scanning was performed on 94 South Korean patients (nine men, 85 women, 188 knees) with osteoarthritis of the knee joint prior to TKR. The tibial anteroposterior (AP) axis was defined as a line perpendicular to the femoral surgical transepicondylar axis and passing through the centre of the posterior cruciate ligament (PCL). The angles between the defined tibial AP axis and anatomical landmarks at various levels of the tibia were measured. The mean values of the angles between the defined tibial AP axis and the line connecting the anterior border of the proximal third of the tibia to the centre of the PCL was -0.2° (-17 to 14.1, sd 4.1). This was very close to the defined tibial axis, and remained so regardless of lower limb alignment and the degree of tibial bowing. Therefore, AP axis defined as described, is a reliable anatomical landmark for rotational alignment of tibial components.

Cite this article: Bone Joint J 2014; 96-B:1485–90.


Bone & Joint 360
Vol. 3, Issue 5 | Pages 25 - 28
1 Oct 2014

The October 2014 Trauma Roundup360 looks at: proximal humeral fractures in children; quadrilateral surface plates in transverse acetabular fractures; sleep deprivation and poor outcomes in trauma; bipolar hemiarthroplasty; skeletal traction; forefoot fractures; telemedicine in trauma; ketamine infusion for orthopaedic injuries; and improved functional outcomes seen with trauma networks.


Bone & Joint 360
Vol. 2, Issue 1 | Pages 30 - 32
1 Feb 2013

The February 2013 Trauma Roundup360 looks at: the risk of ankle fractures; absorbable implants; minimally invasive heel fracture fixation; pertrochanteric fractures; arthroplasty and intracapsular hip fractures; and extensor mechanism disruption.


Bone & Joint 360
Vol. 3, Issue 4 | Pages 25 - 28
1 Aug 2014

The August 2014 Trauma Roundup360 looks at: On-table CT for calcaneal fractures; timing of femoral fracture surgery and outcomes; salvage arthroplasty for failed internal fixation of the femoral neck; screw insertion in osteoporotic bone; fibular intramedullary nailing on the ascendant; posterior wall acetabular fractures not all that innocent; bugs, plating and resistance and improving outcomes in olecranon tension band wiring.


The Bone & Joint Journal
Vol. 96-B, Issue 8 | Pages 1035 - 1040
1 Aug 2014
Meling T Nawab A Harboe K Fosse L

An atypical femoral fracture (AFF), with a transverse fracture radiologically through the lateral cortex is a rare but serious condition. In order to improve our ability to identify patients with this condition, we retrospectively surveyed all subtrochanteric, peri-implant and diaphyseal femoral fractures in patients aged ≥ 65 years who underwent surgical treatment at our hospital between 2004 and 2011.

We describe the incidence of atypical fractures and their characteristics, with observational data including a review of the hospital and general practitioner records. Clinical outcomes were evaluated using the Harris hip score (HHS) and the timed up-and-go (TUG) test.

Atypical fractures only occurred in women with an incidence of 9.8 per 100 000 person-years. The incidence in those who were treated with bisphosphonates was 79.0 per 100 000 person-years; eight of 17 fractures occurred around metal implants. There was a high incidence of delayed union and revision surgery. A total of nine patients (ten AFFs) were available for review at a mean follow-up of 36.5 months (10 to 104). The clinical outcome was poor with a mean HHS of 58.9 (95% CI 47.4 to 70.4) and a mean TUG test of 25.7 s (95% CI 12.7 to 38.8).

The delay in diagnosis and treatment of AFF may result from a lack of knowledge of this condition.

Cite this article: Bone Joint J 2014; 96-B:1035–40.


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1274 - 1281
1 Sep 2014
Farhang K Desai R Wilber JH Cooperman DR Liu RW

Malpositioning of the trochanteric entry point during the introduction of an intramedullary nail may cause iatrogenic fracture or malreduction. Although the optimal point of insertion in the coronal plane has been well described, positioning in the sagittal plane is poorly defined.

The paired femora from 374 cadavers were placed both in the anatomical position and in internal rotation to neutralise femoral anteversion. A marker was placed at the apparent apex of the greater trochanter, and the lateral and anterior offsets from the axis of the femoral shaft were measured on anteroposterior and lateral photographs. Greater trochanteric morphology and trochanteric overhang were graded.

The mean anterior offset of the apex of the trochanter relative to the axis of the femoral shaft was 5.1 mm (sd 4.0) and 4.6 mm (sd 4.2) for the anatomical and neutralised positions, respectively. The mean lateral offset of the apex was 7.1 mm (sd 4.6) and 6.4 mm (sd 4.6), respectively.

Placement of the entry position at the apex of the greater trochanter in the anteroposterior view does not reliably centre an intramedullary nail in the sagittal plane. Based on our findings, the site of insertion should be about 5 mm posterior to the apex of the trochanter to allow for its anterior offset.

Cite this article: Bone Joint J 2014;96-B:1274–81.


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1370 - 1376
1 Oct 2015
Jordan RW Saithna A

This article is a systematic review of the published literature about the biomechanics, functional outcome and complications of intramedullary nailing of fractures of the distal radius.

We searched the Medline and EMBASE databases and included all studies which reported the outcome of intramedullary (IM) nailing of fractures of the distal radius. Data about functional outcome, range of movement (ROM), strength and complications, were extracted. The studies included were appraised independently by both authors using a validated quality assessment scale for non-controlled studies and the CONSORT statement for randomised controlled trials (RCTs).

The search strategy revealed 785 studies, of which 16 were included for full paper review. These included three biomechanical studies, eight case series and five randomised controlled trials (RCTs).

The biomechanical studies concluded that IM nails were at least as strong as locking plates. The clinical studies reported that IM nailing gave a comparable ROM, functional outcome and grip strength to other fixation techniques.

However, the mean complication rate of intramedullary nailing was 17.6% (0% to 50%). This is higher than the rates reported in contemporary studies for volar plating. It raises concerns about the role of intramedullary nailing, particularly when comparative studies have failed to show that it has any major advantage over other techniques. Further adequately powered RCTs comparing the technique to both volar plating and percutaneous wire fixation are needed.

Cite this article: Bone Joint J 2015;97-B:1370–6.


Bone & Joint Research
Vol. 3, Issue 5 | Pages 146 - 149
1 May 2014
Jameson SS Baker PN Deehan DJ Port A Reed MR

The National Institute for Health and Clinical Excellence (NICE) has thus far relied on historical data and predominantly industry-sponsored trials to provide evidence for venous thromboembolic (VTE) prophylaxis in joint replacement patients. We argue that the NICE guidelines may be reliant on assumptions that are in need of revision. Following the publication of large scale, independent observational studies showing little difference between low-molecular-weight heparins and aspirin, and recent changes to the guidance provided by other international bodies, should NICE reconsider their recommendations?

Cite this article: Bone Joint Res 2014;3:146–9.


Bone & Joint 360
Vol. 3, Issue 3 | Pages 25 - 27
1 Jun 2014

The June 2014 Shoulder & Elbow Roundup360 looks at: suprascapular nerve and rotator cuff pathology; anchors in Bankart repair: it’s not what you’ve got, but how you use it; not all shoulder PROMs are equal; reverse shoulder arthroplasty OK in trauma; not all in the mind: frozen shoulder personality debunked; open and arthroscopic repair equivalent in shoulder instability; natural history of olecranon fractures not so bleak?; and resurfacing of the shoulder: a Danish perspective.