Patients with flexion instability after total knee arthroplasty
(TKA) often present with a recurrent effusion, which may be a haemarthrosis.
While the radiographic factors contributing to flexion instability
have been elucidated, the clinical diagnosis remains challenging.
Our aim, in this study, was to determine the mean white cell count
and differential profile in pre-operative aspirations of synovial
fluid in a consecutive series of patients undergoing revision TKA
for flexion instability. Between 2000 and 2010, 60 patients undergoing aseptic revision
TKA for flexion instability were identified. The results of the
pre-operative aspiration of synovial fluid were available for 53
patients (88%). These patients were 1:2 matched to 106 patients
who underwent aseptic TKA for indications other than flexion instability.
The mean age of the patients at revision TKA was 65 years (44 to
82) and 55% were women. The mean follow-up was 4.3 years (2 to 10.2).Aims
Patients and Methods
Our aim was to examine the clinical and radiographic outcomes
in 257 consecutive Oxford unicompartmental knee arthroplasties (OUKAs)
(238 patients), five years post-operatively. A retrospective evaluation was undertaken of patients treated
between April 2008 and October 2010 in a regional centre by two
non-designing surgeons with no previous experience of UKAs. The
Oxford Knee Scores (OKSs) were recorded and fluoroscopically aligned
radiographs were assessed post-operatively at one and five years.Aims
Patients and Methods
Positive cultures are not uncommon in cases of revision total
knee and hip arthroplasty (TKA and THA) for presumed aseptic causes.
The purpose of this study was to assess the incidence of positive
intra-operative cultures in presumed aseptic revision of TKA and
THA, and to determine whether the presence of intra-operative positive cultures
results in inferior survival in such cases. A retrospective cohort study was assembled with 679 patients
undergoing revision knee (340 cases) or hip arthroplasty (339 cases)
for presumed aseptic causes. For all patients three or more separate
intra-operative cultures were obtained. Patients were diagnosed
with a previously unsuspected prosthetic joint infection (PJI) if two
or more cultures were positive with the same organism. Records were
reviewed for demographic details, pre-operative laboratory results
and culture results. The primary outcome measure was infection-free
implant survival at two years.Aims
Patients and Methods
To investigate whether elective joint arthroplasty performed
at the weekend is associated with a different 30-day mortality We examined the 30-day cumulative mortality rate (Kaplan-Meier)
for all elective hip and knee arthroplasties performed in England
and Wales between 1st April 2003 and 31st December 2014, comprising
118 096 episodes undertaken at the weekend and 1 233 882 episodes
performed on a weekday. We used Cox proportional-hazards regression
models to assess for time-dependent variation and adjusted for identified
risk factors for mortality.Aims
Patients and Methods
To validate the English language Forgotten Joint Score-12 (FJS-12)
as a tool to evaluate the outcome of hip and knee arthroplasty in
a United Kingdom population. All patients undergoing surgery between January and August 2014
were eligible for inclusion. Prospective data were collected from
205 patients undergoing total hip arthroplasty (THA) and 231 patients
undergoing total knee arthroplasty (TKA). Outcomes were assessed
with the FJS-12 and the Oxford Hip and Knee Scores (OHS, OKS) pre-operatively,
then at six and 12 months post-operatively. Internal consistency,
convergent validity, effect size, relative validity and ceiling
effects were determined.Aims
Patients and Methods
We sought to determine whether cobalt-chromium alloy (CoCr) femoral
stem tapers (trunnions) wear more than titanium (Ti) alloy stem
tapers (trunnions) when used in a large diameter (LD) metal-on-metal
(MoM) hip arthroplasty system. We performed explant analysis using validated methodology to
determine the volumetric material loss at the taper surfaces of
explanted LD CoCr MoM hip arthroplasties used with either a Ti alloy
(n = 28) or CoCr femoral stem (n = 21). Only 12/14 taper constructs
with a rough male taper surface and a nominal included angle close
to 5.666° were included. Multiple regression modelling was undertaken
using taper angle, taper roughness, bearing diameter (horizontal
lever arm) as independent variables. Material loss was mapped using
a coordinate measuring machine, profilometry and scanning electron
microscopy.Aims
Patients and Methods
The purpose of our study is to summarise the current scientific
findings regarding the impact of obesity on total hip arthroplasty
(THA); specifically the influence of obesity on the timing of THA,
incidence of complications, and effect on clinical and functional
outcomes. We performed a systematic review that was compliant with the
Preferred Reporting Items for Systematic Reviews and Meta-Analyses
guidelines to identify prospective studies from the PubMed/Medline,
Embase, and Cochrane Library databases that evaluated primary THA
in obese (body mass index (BMI) ≥ 30 kg/m2) patients.Aims
Materials and Methods
We reviewed all patients who sustained a fracture of the hip
and were treated in Northern Ireland over a period of 15 years to
identify trends in incidence, the demographics of the patients,
the rates of mortality, the configuration of the fracture and the
choice of implant. Since 01 January 2001 data about every fracture of the hip sustained
in an adult have been collected centrally in Northern Ireland. All
adults with such a fracture between 2000 and 2015 were included
in the study. Temporal changes in their demographics, the mode of
treatment, and outcomes including mortality were analysed.Aims
Patients and Methods
Up to 40% of unicompartmental knee arthroplasty (UKA) revisions are performed for unexplained pain which may be caused by elevated proximal tibial bone strain. This study investigates the effect of tibial component metal backing and polyethylene thickness on bone strain in a cemented fixed-bearing medial UKA using a finite element model (FEM) validated experimentally by digital image correlation (DIC) and acoustic emission (AE). A total of ten composite tibias implanted with all-polyethylene (AP) and metal-backed (MB) tibial components were loaded to 2500 N. Cortical strain was measured using DIC and cancellous microdamage using AE. FEMs were created and validated and polyethylene thickness varied from 6 mm to 10 mm. The volume of cancellous bone exposed to < -3000 µε (pathological loading) and < -7000 µε (yield point) minimum principal (compressive) microstrain and > 3000 µε and > 7000 µε maximum principal (tensile) microstrain was computed.Objectives
Materials and Methods
The MAGnetic Expansion Control (MAGEC) system
is used increasingly in the management of early-onset scoliosis.
Good results have been published, but there have been recent reports
identifying implant failures that may be associated with significant
metallosis surrounding the implants. This article aims to present
the current knowledge regarding the performance of this implant,
and the potential implications and strategies that may be employed
to identify and limit any problems. We urge surgeons to apply caution to patient and construct selection;
engage in prospective patient registration using a spine registry;
ensure close clinical monitoring until growth has ceased; and send
all explanted MAGEC rods for independent analysis. The MAGEC system may be a good instrumentation system for the
treatment of early-onset scoliosis. However, it is innovative and
like all new technology, especially when deployed in a paediatric
population, robust systems to assess long-term outcome are required
to ensure that patient safety is maintained. Cite this article:
To determine the outcomes following revision surgery of metal-on-metal
hip arthroplasties (MoMHA) performed for adverse reactions to metal
debris (ARMD), and to identify factors predictive of re-revision. We performed a retrospective observational study using National
Joint Registry (NJR) data on 2535 MoMHAs undergoing revision surgery
for ARMD between 2008 and 2014. The outcomes studied following revision were
intra-operative complications, mortality and re-revision surgery.
Predictors of re-revision were identified using competing-risk regression
modelling.Aims
Patients and Methods