Advertisement for orthosearch.org.uk
Results 461 - 480 of 1103
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 49-B, Issue 2 | Pages 362 - 367
1 May 1967
Gad P

1. A method of finger dissection is described which provides a new approach to the anatomical study of structures in close relation to joints. 2. The volar part of the capsule of the finger joints is described, the attachment to the bones being particularly emphasised together with its form which is like that of a meniscus. 3. A gap between bone and tendon sheath is described. 4. Theoretical and clinical aspects of the local anatomy are discussed


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 5 | Pages 751 - 754
1 Nov 1986
Roberts J

A study of 79 children with malunion of forearm fractures is presented. Age at the time of injury, the site of the fracture and the degree and direction of angulation at union were correlated with loss of forearm rotation at review 3.5 to 6 years later. Some guidelines are proposed for the acceptability of angular deformity at union, importance being placed on the avoidance of radial deviation of the radius, and the maintenance of the interosseous gap between the shafts of the radius and ulna


Bone & Joint 360
Vol. 8, Issue 6 | Pages 22 - 26
1 Dec 2019


Bone & Joint Research
Vol. 8, Issue 10 | Pages 472 - 480
1 Oct 2019
Hjorthaug GA Søreide E Nordsletten L Madsen JE Reinholt FP Niratisairak S Dimmen S

Objectives

Experimental studies indicate that non-steroidal anti-inflammatory drugs (NSAIDs) may have negative effects on fracture healing. This study aimed to assess the effect of immediate and delayed short-term administration of clinically relevant parecoxib doses and timing on fracture healing using an established animal fracture model.

Methods

A standardized closed tibia shaft fracture was induced and stabilized by reamed intramedullary nailing in 66 Wistar rats. A ‘parecoxib immediate’ (Pi) group received parecoxib (3.2 mg/kg bodyweight twice per day) on days 0, 1, and 2. A ‘parecoxib delayed’ (Pd) group received the same dose of parecoxib on days 3, 4, and 5. A control group received saline only. Fracture healing was evaluated by biomechanical tests, histomorphometry, and dual-energy x-ray absorptiometry (DXA) at four weeks.


Bone & Joint 360
Vol. 9, Issue 2 | Pages 23 - 27
1 Apr 2020


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 6 | Pages 962 - 966
1 Nov 1993
Yadav S

We treated 25 patients with severely deformed and shortened lower limbs by double oblique diaphyseal osteotomy of the short deformed bone, followed by balanced skeletal traction to correct the alignment and increase the length of the limb. The technique is simple and inexpensive and does not require special equipment. It has the advantage of allowing rapid lengthening and secure healing as the overlap allows end-to-end union with no bone gap. The lengthening achieved ranged from 6 to 16 cm. No serious complications were encountered


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 1 | Pages 130 - 132
1 Jan 1992
Maffulli N Hughes T Fixsen J

Limb lengthening in nine patients was monitored by radiographs and by ultrasound scans. The distraction gap appeared as a sonolucent area within which echogenic foci developed soon after distraction commenced. By seven weeks a new cortex was detected, and medullary canal began to develop between seven and eight weeks. Ultrasound scanning can be used to measure distraction, but it was not as useful as radiographs in detecting angulation. Its use in patients undergoing limb lengthening could reduce their exposure to radiation


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 3 | Pages 366 - 371
1 Apr 2004
Nabeyama R Matsuda S Miura H Mawatari T Kawano T Iwamoto Y

Our study evaluated the accuracy of an image-guided total knee replacement system based on CT with regard to preparation of the femoral and tibial bone using nine limbs from five cadavers. The accuracy was assessed by direct measurement using an extramedullary alignment rod without radiographs. The mean angular errors of the femur and tibia, which represent angular gaps from the real mechanical axis in the coronal plane, were 0.3° and 1.1°, respectively. The CT-based system, provided almost perfect alignment of the femoral component with less than 1° of error and excellent alignment with less than 3° of error for the tibial component. Our results suggest that standardisation of knee replacement by the use of this system will lead to improved long-term survival of total knee arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 48-B, Issue 2 | Pages 333 - 335
1 May 1966
Giannikas AC

1. Three patients with enchondromata of the metacarpal bones are described. 2. The nature of the enchondromata in all three patients was confirmed by histological examination. 3. Treatment was by radical excision and bridging of the gap by a cortical bone graft. 4. There has been no impairment of function in the hands. No patient complained of pain after the operation. 5. Radiographs taken one year after operation in two patients showed that the flat bone grafts had become cylindrical and that medullary canals had appeared


The Journal of Bone & Joint Surgery British Volume
Vol. 30-B, Issue 4 | Pages 595 - 605
1 Nov 1948
Le Mesurier AB

Most of what I have said has been said before by various writers. Abduction osteotomy is the recognised form of treatment for developmental coxa vara. The results from this operation are usually good. But the results of treatment would probably be better if the condition could be diagnosed before deformity had become disabling, and if the gap in the bone could be closed by other means than osteotomy. Good results of bone grafting in early cases of developmental coxa vara are reported


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 5 | Pages 719 - 722
1 Nov 1987
Dias J Steingold R Richardson R Tesfayohannes B Gregg P

The treatment of acromioclavicular injuries is controversial; few studies document the late results. We have reviewed 53 patients about five years after conservative management, in nine for subluxation and 44 for dislocation. Subjective and objective results were satisfactory in all cases except for one with painful subluxation, who was the only patient to change her occupation because of the injury. At review, joint stability was demonstrated by improvement in position and by the very small increase in the coracoclavicular gap on stress radiographs


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 2 | Pages 293 - 297
1 Mar 1988
Jones W

A consecutive series of 100 cases of wrist injury, other than those referred with a radial fracture, have been reviewed to determine the incidence of acute scapholunate instability; a "clenched fist" radiograph was used in addition to the routine scaphoid views. Of 19 patients with an increase in the scapholunate gap, five were eventually considered to have significant scapholunate instability, two in association with Colles' fractures. Injuries producing significant ligamentous damage and carpal instability may be as common as scaphoid fractures. They require special consideration in diagnosis and management


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 4 | Pages 416 - 421
1 Aug 1982
Ryan M Taylor T

Twenty-three adults with fractures of the odontoid process are reviewed. Te possible reasons for the high rate of non-union in reported series are considered: these include the type of fracture, its displacement, the presence of a gap at the fracture site, imperfect reduction and inadequate immobilisation. Type 2 fractures (at the base of the odontoid process) are the commonest and also the most liable to nonunion. In their treatment, reduction is important; as seen in the lateral radiograph at least two-thirds of the fracture surfaces should be in contact. Skull traction is not advised and halo-cast fixation is the treatment of choice; with this method 87.5 per cent of recent odontoid fractures united


Bone & Joint 360
Vol. 8, Issue 2 | Pages 12 - 15
1 Apr 2019


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 2 | Pages 307 - 310
1 Mar 1989
Dias J Brenkel I Finlay D

Eighty-two of 85 patients who had sustained a fracture of the waist of the scaphoid in 1985 were reviewed more than one year after injury. The incidence of nonunion, defined as a clear gap at the fracture site one year after injury, was 12.3%. This was much higher than expected. Most of the patients with nonunion had symptoms and had appreciable restriction of wrist movement. In a further 25% of the patients at review, the site of the fracture could be easily identified although it appeared to have healed. These patients were older and more of them were women. Three-quarters of these patients had symptoms but their wrist movement was essentially normal


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 2 | Pages 313 - 316
1 Mar 1985
Howard C McKibbin B Ralis Z

We have studied the use of filamentous polyglycolic acid (Dexon) for the induction of neotendon in the calcaneal tendon of sheep. Uniformly good results were obtained, with the formation of a thick neotendon. However, in a control group the power of spontaneous regeneration of the tendon was studied; it was found that, provided overlengthening of the gap was prevented, an equally good tendon resulted. It is concluded that this particular model is not an appropriate one for testing neotendon induction, despite its use for this purpose in the past. The favourable results of using filamentous polyglycolic acid as a tendon replacement suggest that it should be further investigated (in a more suitable model) since it may well have useful clinical applications


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 1 | Pages 52 - 53
1 Feb 1982
Sondergard-Petersen P Mikkelsen P

Posterior dislocation of the acromioclavicular joint with the lateral end of the clavicle locked behind the acromion has only rarely been described. This paper present such a case diagnosed two weeks after the shoulder was injured in an accident. The clavicle was locked behind the articular surface of the acromion, restricting the movement of the shoulder and causing considerable pain. Anteroposterior radiographs showed a high-riding clavicle but no gap in the joint, but the axial view showed the dislocation. At operation the coracoclavicular ligaments were found overstretched but not ruptured. As reduction of the acromioclavicular joint was not possible, the lateral end of the clavicle was resected. Although the result was perfect, we consider the correct treatment should be early closed or open reduction of the acromioclavicular joint


The Journal of Bone & Joint Surgery British Volume
Vol. 61-B, Issue 4 | Pages 455 - 463
1 Nov 1979
Campanacci M Costa P

Resection of the distal femur or proximal tibia en bloc has been performed on twenty-six patients with primary bone tumours. The gap was filled with autogenous bone grafts stabilised with a long intramedullary nail, thus arthrodesing the knee. In two cases temporary stabilisation with a Kuntscher rod and acrylic cement was adopted because of adjuvant chemotherapy. Union was achieved in twenty-four cases (92 per cent). Infection was the main and practically the only major complication, occurring in five (19 per cent) of the cases: it healed with union in three, healed with non-union in one, and led to an above-knee amputation in the fifth case. Follow-up has been from one to eight years with an average of four years


The Journal of Bone & Joint Surgery British Volume
Vol. 47-B, Issue 1 | Pages 36 - 42
1 Feb 1965
Debeyre J Patte D Elmelik E

1. The results of operation in sixty-three patients with rupture of the rotator cuff of the shoulder have been reviewed. 2. In seventeen patients the classical delto-pectoral route was found to give poor access and mediocre results. 3. In forty-six patients a superior approach along the supraspinatus fossa and through the divided acromion process was found to give excellent access and to permit lateral advancement of the supraspinatus muscle in order to enable wide gaps to be closed. With this improved surgical access the proportion of good results has been doubled. 4. It is suggested that when a case of rupture of the cuff, confirmed by arthrography, fails to respond to physiotherapy, operative repair should be undertaken


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 5 | Pages 874 - 880
1 Sep 1990
Pereira J Cowley S Gschmeissner S Bowden R Turk J

About 20% of patients with leprosy develop localised granulomatous lesions in peripheral nerves. We report experiments in guinea-pigs in which freeze-thawed autogenous muscle grafts were used for the treatment of such mycobacterial granulomas. Granulomas were induced in guinea-pig tibial nerves and the animals were left for 7 to 100 days in order to assess maximal damage. The local area of nerve damage was then excised and the gap filled with denatured muscle grafts. Clinical assessment after periods up to 150 days showed good sensory and motor recovery which correlated well with the histological findings. The muscle graft technique may be of value for the treatment of chronic nerve lesions in selected cases of leprosy