Advertisement for orthosearch.org.uk
Results 441 - 460 of 1021
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 887 - 892
1 Jul 2006
Pandit H Beard DJ Jenkins C Kimstra Y Thomas NP Dodd CAF Murray DW

The options for treatment of the young active patient with isolated symptomatic osteoarthritis of the medial compartment and pre-existing deficiency of the anterior cruciate ligament are limited. The potential longevity of the implant and levels of activity of the patient may preclude total knee replacement, and tibial osteotomy and unicompartmental knee arthroplasty are unreliable because of the ligamentous instability. Unicompartmental knee arthroplasties tend to fail because of wear or tibial loosening resulting from eccentric loading. Therefore, we combined reconstruction of the anterior cruciate ligament with unicompartmental arthroplasty of the knee in 15 patients (ACLR group), and matched them with 15 patients who had undergone Oxford unicompartmental knee arthroplasty with an intact anterior cruciate ligament (ACLI group). The clinical and radiological data at a minimum of 2.5 years were compared for both groups. The groups were well matched for age, gender and length of follow-up and had no significant differences in their pre-operative scores. At the last follow-up, the mean outcome scores for both the ACLR and ACLI groups were high (Oxford knee scores of 46 (37 to 48) and 43 (38 to 46), respectively, objective Knee Society scores of 99 (95 to 100) and 94 (82 to 100), and functional Knee Society scores of 96 and 96 (both 85 to 100). One patient in the ACLR group needed revision to a total knee replacement because of infection. No patient in either group had radiological evidence of component loosening. The radiological study showed no difference in the pattern of tibial loading between the groups. The short-term clinical results of combined anterior cruciate ligament reconstruction and unicompartmental knee arthroplasty are excellent. The previous shortcomings of unicompartmental knee arthroplasty in the presence of deficiency of the anterior cruciate ligament appear to have been addressed with the combined procedure. This operation seems to be a viable treatment option for young active patients with symptomatic arthritis of the medial compartment, in whom the anterior cruciate ligament has been ruptured


Bone & Joint Research
Vol. 7, Issue 1 | Pages 20 - 27
1 Jan 2018
Kang K Son J Suh D Kwon SK Kwon O Koh Y

Objectives

Patient-specific (PS) implantation surgical technology has been introduced in recent years and a gradual increase in the associated number of surgical cases has been observed. PS technology uses a patient’s own geometry in designing a medical device to provide minimal bone resection with improvement in the prosthetic bone coverage. However, whether PS unicompartmental knee arthroplasty (UKA) provides a better biomechanical effect than standard off-the-shelf prostheses for UKA has not yet been determined, and still remains controversial in both biomechanical and clinical fields. Therefore, the aim of this study was to compare the biomechanical effect between PS and standard off-the-shelf prostheses for UKA.

Methods

The contact stresses on the polyethylene (PE) insert, articular cartilage and lateral meniscus were evaluated in PS and standard off-the-shelf prostheses for UKA using a validated finite element model. Gait cycle loading was applied to evaluate the biomechanical effect in the PS and standard UKAs.


Objectives

Posterior condylar offset (PCO) and posterior tibial slope (PTS) are critical factors in total knee arthroplasty (TKA). A computational simulation was performed to evaluate the biomechanical effect of PCO and PTS on cruciate retaining TKA.

Methods

We generated a subject-specific computational model followed by the development of ± 1 mm, ± 2 mm and ± 3 mm PCO models in the posterior direction, and -3°, 0°, 3° and 6° PTS models with each of the PCO models. Using a validated finite element (FE) model, we investigated the influence of the changes in PCO and PTS on the contact stress in the patellar button and the forces on the posterior cruciate ligament (PCL), patellar tendon and quadriceps muscles under the deep knee-bend loading conditions.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 96 - 99
1 Jan 1991
Korkala O Tanskanen P Makijarvi J Sorvali T Ylikoski M Haapala J

We studied the late outcome of 40 ankles (from a consecutive series of 42) treated by a modified Evans procedure. The peroneus brevis tendon was used to fashion a static tenodesis. All the patients had suffered from persistent lateral instability following an ankle sprain. The follow-up period was between nine and 12 years. Excellent or good results were achieved in 33 ankles (82.5%), three had a fair result, and four were poor. The clinical results were matched by the radiographic results which showed significant talar tilt or anterior talar translation in only three ankles. The functional result showed no positive correlation with the stress-radiographic analysis. We concluded that this modification of the Evans operation gives satisfactory long-term results, which show little change from the good results at 24 to 35 months reported in an earlier paper from our department


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 3 | Pages 377 - 381
1 May 1988
Cheng C Gross A

We reviewed 40 cementless Porous Coated Anatomic knee replacements in 34 consecutive patients. The average follow-up was 12.9 months (range 6 to 36 months). At review, loose beads were identified in 23 knees, in 11 on the femoral side and in 16 on the tibial side (in five knees on both sides). One loose bead was adjacent to the patella. In four knees there were intra-articular beads. Radiolucent lines at the interface between bone and prosthesis were seen in 19 knees, in six on the femoral side and in 16 on the tibial side (in three knees on both sides). In relation to the tibial component loose beads were associated with a radiolucent line in all except one case. Progressive loosening with an increasing number of loose beads was seen in three knees. At this early stage of follow-up there was no correlation between the clinical results and the presence of loose beads


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 2 | Pages 211 - 216
1 Mar 1988
Aglietti P Buzzi R

We have reviewed 85 knees in 71 patients after total-condylar posteriorly stabilised (Insall-Burstein) knee replacement with an average follow-up of five years. Excellent or good results were obtained in 90% with an average maximum flexion of 98 degrees. The four poor results (5%) included two with deep infection, one with patellar dislocation and one with loosening. Four other knees (5%) showed signs of probable tibial loosening, but the patients were asymptomatic, the clinical results had not deteriorated with time and lucent lines had not progressed. Varus alignment of the knee and a varus tilt of more than 2 degrees of the tibial component correlated with the incidence of lucent lines around the tibial implant. No patellar stress fractures were seen but impingement symptoms were present in 20%, although they were troublesome in less than half of them. The virtue of the prosthesis lies in its versatility for use in the severely deformed joint


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 928 - 933
1 Jul 2005
Berli BJ Schäfer D Morscher EW

The Morscher-Spotorno (MS-30) femoral stem is a stainless-steel, straight, three-dimensionally tapered, collarless implant for cemented fixation in total hip replacement. We report the results at ten years of a consecutive series of 124 total hip replacements in 121 patients with the matt-surfaced MS-30 stem and an alumina ceramic head of 28-mm diameter. All the stems were fixed with Palacos bone cement with gentamicin using a modern cementing technique. They were combined with an uncemented, press-fit cup. The mean period of observation was 10.2 years (8.3 to 12.1) and no patient was lost to follow-up. Twenty-seven patients (22%) died with the implant in situ. Nine could only be interviewed by telephone. We included 85 patients with 88 hips in the clinical and radiological follow-up examinations. None of the stems or cups had been revised. The Harris hip score was excellent or good in 97% (85 hips) and moderate in 3% (three hips). Radiologically, six hips (6.8%) had osteolysis adjacent to the stem, mostly in Gruen zone 7. Twenty (22.7%) showed one or more radiolucent lines. Twenty-two stems (25%) had subsided by 2 mm to 5 mm. In these cases two showed osteolysis (9.1%) with subsidence and four without (6.1%). Radiolucent lines were seen in seven with migration (31.8%) and in 13 without (19.7%). No infections and no acetabular osteolysis were observed. The clinical results were excellent with survivorship after ten years of 100% and only a slightly statistically non-significant higher rate of osteolysis and radiolucency in cases of subsidence


The Journal of Bone & Joint Surgery British Volume
Vol. 56-B, Issue 3 | Pages 427 - 437
1 Aug 1974
Porter BB Richardson C Vainio K

1. One hundred and twenty-three patients with rheumatoid arthritis who had synovectomy and excision of the head of the radius performed on 154 elbows have been reviewed one to six years after operation. 2. The severity of the disease process at the time of operation was graded radiologically and an attempt made to relate this to the results. 3. Overall, the clinical results were most satisfactory; more than 70 per cent of the patients were pleased with the outcome. When radiographic deterioration of the joint was taken into account, however, only 54 per cent achieved a "satisfactory" result. 4. Clearance of the synovium through combined medial and lateral incisions gave better results than a lateral approach alone. 5. When the disease was far advanced by the time of operation any good results were likely to be short-lived. 6. The indications for synovectomy of the rheumatoid elbow are discussed in the light of these findings


The Journal of Bone & Joint Surgery British Volume
Vol. 36-B, Issue 3 | Pages 411 - 417
1 Aug 1954
Cregan JCF

1. Sixty-five cases of medial fracture of the femoral neck treated by substitution of the head by an acrylic prosthesis have been studied. 2. In general, the long-term clinical results of prosthetic arthroplasty after fresh fractures have been disappointing. The method has given slightly better results in the treatment of old fractures. 3. In view of the almost perfect results obtained after successful Smith-Petersen nailing in the presence of an adequate blood supply to the femoral head, it seems unjustifiable to abandon this principle for immediate substitution with an acrylic femoral head. Nevertheless it is believed that an arthroplasty of this type is justified in fractures seen late, and in fresh subcapital fractures when the fracture is irreducible. If a prosthesis is to be used, more protection for the stump of the neck against the strain of weight bearing is essential; a simple head prosthesis is inadequate, and a head with either a neck extension or an intramedullary prolongation may give better results


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 24 - 26
1 Jan 1999
Vyskocil P Gerber C Bamert P

The radiolucent lines and the stability of the components of 66 knee arthroplasties were assessed by six orthopaedic surgeons on conventional anteroposterior and lateral radiographs and on fluoroscopic views which had been taken on the same day. The examiners were blinded as to the patients and clinical results. The interpretation of the radiographs was repeated after five months. On fluoroscopically-assisted radiographs four of the six examiners identified significantly more radiolucent lines for the femoral component (p < 0.05) and one significantly more for the tibial implant. Five examiners rated more femoral components as radiologically loose on fluoroscopically-assisted radiographs (p = 0.0008 to 0.0154), but none did so for the tibial components. The mean intra- and interobserver kappa values were higher for fluoroscopically-assisted radiographs for both components. We have shown that fluoroscopically-assisted radiographs allow more reproducible, and therefore reliable, detection of radiolucent lines in total knee arthroplasty. Assessment of the stability of the components is significantly influenced by the radiological technique used. Conventional radiographs are not adequate for evaluation of the stability of total knee arthroplasty and should be replaced by fluoroscopically-assisted films


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 971 - 975
1 Nov 1998
McCaskie AW Deehan DJ Green TP Lock KR Thompson JR Harper WM Gregg PJ

Early implants for total knee replacement were fixed to bone with cement. No firm scientific reason has been given for the introduction of cementless knee replacement and the long-term survivorship of such implants has not shown any advantage over cemented forms. In a randomised, prospective study we have compared cemented and uncemented total knee replacement and report the results of 139 prostheses at five years. Outcome was assessed both clinically by independent examination using the Nottingham knee score and radiologically using the Knee Society scoring system. Independent statistical analysis of the data showed no significant difference between cemented and cementless fixation for pain, mobility or movement. There was no difference in the radiological alignment at five years, but there was a notable disparity in the radiolucent line score. With cemented fixation there was a significantly greater number of radiolucent lines on anteroposterior radiographs of the tibia and lateral radiographs of the femur. At five years, our clinical results would not support the use of the more expensive cementless fixation whereas the radiological results are of unknown significance. Longer follow-up will determine any changes in the results and conclusions


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 1 | Pages 42 - 49
1 Jan 1995
Fairbank A Bhatia D Jinnah R Hungerford D

We have studied the long-term results of core decompression as the sole treatment for Ficat stages I, II and III ischaemic necrosis of 128 femoral heads in 90 patients. The 5-, 10- and 15-year survival rates for the three stages were respectively: stage I 100%, 96% and 90%; stage II 85%, 74% and 66%; and stage III 58%, 35% and 23%. At a mean follow-up of 11 years (4.5 to 19), 55 hips had failed (43%). No further surgery had been needed for 88% of stage-I, 72% of stage-II and 26% of stage-III hips; but despite the generally satisfactory clinical results, 56% of the hips had progressed radiographically by at least one Ficat stage. Complications of the core procedure included four fractures, all from postoperative falls, and one head perforation due to technical error. We conclude that core decompression delays the need for total hip replacement in young patients with ischaemic necrosis


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 636 - 640
1 Jul 1998
Akazawa H Oda K Mitani S Yoshitaka T Asaumi K Inoue H

Arthrogryposis multiplex congenita (AMC) is a rare disease with multiple joint contractures. It is widely believed that bilaterally dislocated hips should not be reduced since movement is satisfactory and open reduction has had poor results. Since 1977 we have performed a new method of open reduction using an extensive anterolateral approach on ten hips in five children with AMC. The mean age at surgery was 31.5 months (17 to 64) and the mean follow-up was 11.8 years (3.8 to 19.5). At the final follow-up all children walked without crutches or canes. Two managed independently, one required a long leg brace and two had short leg braces because of knee and/or foot problems. The clinical results were good in eight hips and fair in two and on the Severin classification seven hips were rated as good (group I or group II). We recommend the extensive anterolateral approach for unilateral or bilateral dislocation of the hip in children with arthrogryposis or developmental dislocation of the hip


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 6 | Pages 888 - 893
1 Aug 2001
Mazda K Boggione C Fitoussi F Penneçot GF

We report the results of 116 consecutive displaced extension supracondylar fractures of the elbow in children treated during the first two years after the introduction of the following protocol; closed reduction under general anaesthesia with fluoroscopic control and lateral percutaneous pinning using two parallel pins or, when closed reduction failed, open reduction and internal fixation by cross-pinning. Eight patients were lost to follow-up during the first postoperative year. The mean follow-up for the remaining 108 was 27.9 months (12 to 47, median 26.5). At the final follow-up, using Flynn’s overall modified classification, the clinical result was considered to be excellent in 99 patients (91.6%), good in five (4.6%) and poor in four (3.7%). All the poor results were due to a poor cosmetic result, but had good or excellent function. Technical error in the initial management of these four cases was thought to be the cause of the poor results. The protocol described resulted in good or excellent results in 96% of our patients, providing a safe and efficient treatment for displaced supracondylar fractures of the humerus even in less experienced hands


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 5 | Pages 640 - 645
1 Jul 2001
Levy O Wilson M Williams H Bruguera JA Dodenhoff R Sforza G Copeland S

We present the short- and medium-term clinical results of thermal shrinkage in selected groups of patients with multidirectional or capsular stretch-type instability. We treated 56 patients (61 shoulders) by laser-assisted capsular shrinkage (LACS) and 34 patients (38 shoulders) by radiofrequency (RF) capsular shrinkage. The two groups were followed for mean periods of 40 months and 23 months, respectively. In the LACS group the mean Walch-Duplay score improved to 90 points 18 months after the operation, but then declined to a plateau of about 80 points; 59% of patients considered their shoulders to be ‘much better’ or ‘better’ but there was a failure rate of 36.1%. For the RF group the mean Walch-Duplay and Constant scores were 80 points at the various follow-up times; 76.3% of patients considered their shoulder to be ‘much better’ or ‘better’. RF failed in nine shoulders (23.7%). These results match some clinical series of patients with multidirectional instability, undergoing open inferior capsular shift, with a similar rate of failure. We believe that the minimal morbidity involved makes thermal shrinkage a viable alternative to open capsular shift in this difficult group of patients


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 5 | Pages 734 - 739
1 Sep 1992
Sugano N Takaoka K Ohzono K Matsui M Saito M Saito S

We reviewed 41 hips in 40 patients at three to 11 years (average 6.3 years) after Sugioka transtrochanteric rotational osteotomy for non-traumatic avascular necrosis of the femoral head. The clinical results were excellent or good in 23 hips (56%) and the radiological success rate was 56%. Failure was due to fracture of the femoral neck, nonunion of the osteotomy, secondary collapse, or osteoarthritis. Nonunion and femoral neck fracture were more common after the use of the large screws described by Sugioka than with AO blade plates. Secondary collapse was significantly more common when less than one-third of the posterior articular surface was intact (p = 0.002). Postoperative degenerative changes were seen in cases with stage III avascular necrosis. We conclude that success depends to a large extent on the amount and stage of necrosis of the femoral head, but that careful technique and the use of AO hip plates may increase the likelihood of a satisfactory result


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 5 | Pages 748 - 752
1 Jul 2002
Berlemann U Ferguson SJ Nolte L Heini PF

Vertebroplasty, which is the percutaneous injection of bone cement into vertebral bodies has recently been used to treat painful osteoporotic compression fractures. Early clinical results have been encouraging, but very little is known about the consequences of augmentation with cement for the adjacent, non-augmented level. We therefore measured the overall failure, strength and structural stiffness of paired osteoporotic two-vertebra functional spine units (FSUs). One FSU of each pair was augmented with polymethyl-methacrylate bone cement in the caudal vertebra, while the other served as an untreated control. Compared with the controls, the ultimate failure load for FSUs treated by injection of cement was lower. The geometric mean treated/untreated ratio of failure load was 0.81, with 95% confidence limits from 0.70 to 0.92, (p < 0.01). There was no significant difference in overall FSU stiffness. For treated FSUs, there was a trend towards lower failure loads with increased filling with cement (r. 2. = 0.262, p = 0.13). The current practice of maximum filling with cement to restore the stiffness and strength of a vertebral body may provoke fractures in adjacent, non-augmented vertebrae. Further investigation is required to determine an optimal protocol for augmentation


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 1 | Pages 14 - 18
1 Jan 2001
Nimon GA Dobson PJ Angel KR Lewis PL Stevenson TM

Of 111 primary ankle ligament arthroplasties (modified Evans procedure) performed between 1983 and 1994, we were able to identify 89 patients (94 ankles) for follow-up. All were under 50 years of age. Two had died and one refused to co-operate; 86 patients (91 ankles) were therefore reviewed, 25 by telephone and the remainder by clinical examination with all but three also undergoing radiological review. Of the 91 ankles, 70 had no or very mild pain and 72 had no or rare episodes of instability and when considered together only 59 (65%) had no or mild pain and minimal instability. The results were supported by the Karlsson grading system. Clinical examination showed that 17 of the 66 ankles examined had increased inversion, while 21 had some limitation of inversion. Early degenerative changes were seen in 11 ankles, although only four had subtalar changes. These results show that this procedure does not give universally good clinical results. Patient satisfaction, however, was high with 97.7% being willing to undergo the same procedure if their other ankle became similarly affected


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 8 | Pages 1107 - 1112
1 Nov 2000
Hintermann B Trouillier HH Schäfer D

In 42 elderly patients, 33 women and nine men with a mean age of 72 years, we treated displaced fractures of the proximal humerus (34 three-part, 8 four-part) using a blade plate and a standard deltopectoral approach. Functional treatment was started immediately after surgery. We reviewed 41 patients at one year and 38 at final follow-up at 3.4 years (2.4 to 4.5). At the final review, all the fractures had healed. The clinical results were graded as excellent in 13 patients, good in 17, fair in seven, and poor in one. The median Constant score was 73 ± 18. Avascular necrosis of the humeral head occurred in two patients (5%). We conclude that rigid fixation of displaced fractures of the proximal humerus with a blade plate in the elderly patient provides sufficient primary stability to allow early functional treatment. The incidence of avascular necrosis and nonunion was low. Restoration of the anatomy and biomechanics may contribute to a good functional outcome when compared with alternative methods of fixation or conservative treatment. Regardless of the age of the patients, we advocate primary open reduction and rigid internal fixation of three- and four-part fractures of the proximal humerus


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 8 | Pages 1121 - 1125
1 Nov 2002
Trail IA Nuttall D

We have performed a clinical and radiological analysis of 105 shoulder arthroplasties in patients with rheumatoid arthritis. The clinical results showed improvements in the Constant-Murley and Association of Shoulder and Elbow Surgeons score of 21 and 35, respectively. Both were statistically significant (p < 0.001). This improvement was maintained over a period of 8.8 years. There was no statistically significant difference in the scores after hemiarthroplasty and those after total arthroplasty. The presence of an intact rotator cuff was associated with improved function in both groups. In spite of the use of an uncemented humeral stem, no implant was radiologically loose or at risk. There was lucency in a single zone in 14 implants. One glenoid component was at risk and 16 had lucency in a single zone. There was, however, a significant difference in the amount of lucency which was associated with pegged and keeled glenoid components (p = 0.005). In the group with hemiarthroplasty, two or more years after surgery there was superior migration of the humeral component by more than 5 mm in 18 shoulders (28%) and medial migration by more than 2 mm in eight (16%). Both superior and medial migration had an effect on the outcome. Revision was undertaken in four patients for persistent pain relating to medial migration. With revision taken as the endpoint for survival after eight years, 92% were found to be still in situ