Advertisement for orthosearch.org.uk
Results 421 - 440 of 946
Results per page:
The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 170 - 177
1 Feb 2019
Puri A Gulia A Hegde P Verma V Rekhi B

Aims

The aims of this study were to evaluate the efficacy of preoperative denosumab in achieving prospectively decided intention of therapy in operable giant cell tumour of bone (GCTB) patients, and to document local recurrence-free survival (LRFS).

Patients and Methods

A total of 44 patients received preoperative denosumab: 22 to facilitate curettage, 16 to facilitate resection, and six with intent of converting resection to curettage. There were 26 male and 18 female patients. The mean age was 27 years (13 to 47).


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 423 - 425
1 Apr 2003
Wigderowitz CA Cunningham T Rowley DI Mole PA Paterson CR

Fractures of the distal forearm are widely regarded as the result of “fragility”. We have examined the extent to which patients with Colles’ fractures have osteopenia. We measured the bone mineral density (BMD) in the contralateral radius of 235 women presenting with Colles’ fractures over a period of two years. While women of all ages had low values for ultra-distal BMD, the values, in age-matched terms, were particularly low among premenopausal women aged less than 45 years. This result was not due to the presence of women with an early menopause. This large survey confirms and extends the findings from earlier small studies. We consider that it is particularly important to investigate young patients with fractures of the distal forearm to identify those with osteoporosis, to seek an underlying cause and to consider treatment


Bone & Joint 360
Vol. 8, Issue 5 | Pages 33 - 35
1 Oct 2019


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 2 | Pages 234 - 239
1 Mar 1998
Kudo H

Six highly unstable elbows with severe bone loss due to rheumatoid arthritis were replaced by a non-constrained, unlinked prosthesis. Bone defects were filled with autogenous bone grafts. The mean follow-up was 4.5 years (2 to 8). The clinical results were excellent in four elbows and good in two, with good varus-valgus stability in all. Radiological follow-up showed no appreciable signs of loosening, and the bone grafts had retained most of their original size, with minimal resorption. There were no major complications such as dislocation, skin necrosis, infection or ulnar neuropathy. The study has shown that the so-called mutilans elbow can be successfully replaced using a properly selected type of non-constrained, unlinked prosthesis with bone grafting of the major defects


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 724 - 730
1 Jun 2008
Hartofilakidis G Georgiades G Babis GC Yiannakopoulos CK

We have evaluated the results of total hip replacement in patients with congenital hip disease using 46 cemented all-polyethylene Charnley acetabular components implanted with the cotyloplasty technique in 34 patients (group A), and compared them with 47 metal-backed cementless acetabular components implanted without bone grafting in 33 patients (group B). Patients in group A were treated between 1988 and 1993 and those in group B between 1990 and 1995. The mean follow-up for group A was 16.6 years (12 to 18) and the mean follow-up for group B was 13.4 years (10 to 16). Revision for aseptic loosening was undertaken in 15 hips (32.6%) in group A and in four hips (8.5%) in group B. When liner exchange was included, a total of 13 hips were revised in group B (27.7%). The mean polyethylene wear was 0.11 mm/yr (0.002 to 0.43) and 0.107 mm/yr (0 to 0.62) for groups A and B, respectively. Polyethylene wear in group A was associated with linear osteolysis, and in group B with expansile osteolysis. In patients with congenital hip disease, when 80% cover of the implant can be obtained, a cementless acetabular component appears to be acceptable and provides durable fixation. However, because of the type of osteolysis arising with these devices, early exchange of a worn liner is recommended before extensive bone loss makes revision surgery more complicated


Bone & Joint Research
Vol. 8, Issue 10 | Pages 443 - 450
1 Oct 2019
Treacy RBC Holland JP Daniel J Ziaee H McMinn DJW

Objectives

Modern metal-on-metal (MoM) hip resurfacing arthroplasty (HRA), while achieving good results with well-orientated, well-designed components in ideal patients, is contraindicated in women, men with head size under 50 mm, or metal hypersensitivity. These patients currently have no access to the benefits of HRA. Highly crosslinked polyethylene (XLPE) has demonstrated clinical success in total hip arthroplasty (THA) and, when used in HRA, potentially reduces metal ion-related sequelae. We report the early performance of HRA using a direct-to-bone cementless mono-bloc XLPE component coupled with a cobalt-chrome femoral head, in the patient group for whom HRA is currently contraindicated.

Methods

This is a cross-sectional, observational assessment of 88 consecutive metal-on-XLPE HRAs performed in 84 patients between 2015 and 2018 in three centres (three surgeons, including the designer surgeon). Mean follow-up is 1.6 years (0.7 to 3.9). Mean age at operation was 56 years (sd 11; 21 to 82), and 73% of implantations were in female patients. All patients were individually counselled, and a detailed informed consent was obtained prior to operation. Primary resurfacing was carried out in 85 hips, and three cases involved revision of previous MoM HRA. Clinical, radiological, and Oxford Hip Score (OHS) assessments were studied, along with implant survival.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 5 | Pages 759 - 770
1 Jul 2004
Vermes C Chandrasekaran R Dobai JG Jacobs JJ Andersson GBJ An H Hallab NJ Galante JO Glant TT

Periprosthetic bone loss after total joint arthroplasty is a major clinical problem resulting in aseptic loosening of the implant. Among many cell types, osteoblasts play a crucial role in the development of peri-implant osteolysis. In this study, we tested the effects of calcitriol (1α,25-dihydroxy-vitamin-D. 3. ) and the bisphosphonate pamidronate on titanium-particle- and TNF-α-induced release of interleukin-6 and suppression of osteoblast-specific gene expressions in bone-marrow-derived stromal cells with an osteoblastic phenotype. We monitored the expression of procollagen α1[1], osteocalcin, osteonectin and alkaline phosphatase mRNAs by Northern blots and real-time reverse transcription and polymerase chain reaction analyses. The release of various cytokines was also analysed by ELISA. We found that calcitriol or pamidronate could only partially recover the altered functions of osteoblasts when added alone. Only a combination of these compounds restored all the tested functions of osteoblasts. The local delivery of these drugs may have therapeutic potential to prevent or to treat periprosthetic osteolysis and aseptic loosening of implants


Objectives

MicroRNAs (miRNAs) have been reported as key regulators of bone formation, signalling, and repair. Fracture healing is a proliferative physiological process where the body facilitates the repair of a bone fracture. The aim of our study was to explore the effects of microRNA-186 (miR-186) on fracture healing through the bone morphogenetic protein (BMP) signalling pathway by binding to Smad family member 6 (SMAD6) in a mouse model of femoral fracture.

Methods

Microarray analysis was adopted to identify the regulatory miR of SMAD6. 3D micro-CT was performed to assess the bone volume (BV), bone volume fraction (BVF, BV/TV), and bone mineral density (BMD), followed by a biomechanical test for maximum load, maximum radial degrees, elastic radial degrees, and rigidity of the femur. The positive expression of SMAD6 in fracture tissues was measured. Moreover, the miR-186 level, messenger RNA (mRNA) level, and protein levels of SMAD6, BMP-2, and BMP-7 were examined.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 6 | Pages 884 - 891
1 Nov 1996
Malchau H Herberts P Wang YX Kärrholm J Romanus B

We enrolled 98 patients (107 hips) with a mean age of 47 years (SD 8.6) into a prospective study of the Madreporic Lord THR; 34 hips had primary and 73 secondary osteoarthritis. After ten years, the survival rate using revision as the endpoint for failure was 70% (±9) for the cup and 98% (±0.3) for the stem. The combined clinical and radiological survival rates were 46% (±11) and 81% (±10), respectively. Osteoporosis due to stress-shielding was observed in the proximal femur. Hips with radiologically dense bone postoperatively showed the most pronounced bone loss. We recommend continued radiological follow-up of patients with this type of implant to allow revision to be performed before there is severe bony destruction of the pelvis


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 6 | Pages 914 - 917
1 Nov 1993
Janes G Collopy D Price R Sikorski J

We used dual-energy X-ray absorptiometry (DEXA) to measure the bone mineral content (BMC) of both tibiae in 13 patients who had been treated for a tibial fracture by rigid plate fixation. Within two weeks of plate removal the BMC was significantly greater in the bone that had been under the plate than at the same site in the control tibia. An unplated area of bone near the ankle showed a significant decrease in BMC at the time of plate removal with subsequent return to the level of the control tibia during the ensuing 18 months. We conclude that osteoinductive influences outweigh the potential causes of osteopenia, such as stress shielding and disuse, and that, contrary to expectation, demineralisation is not a factor in the diminished strength of the tibia after plating for fracture


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 4 | Pages 517 - 520
1 May 2003
Mackay DC Siddique MS

We have compared the survival of 67 revision arthroplasties of the knee undertaken for aseptic loosening with and without the retention of a secure, cemented femoral component. All the patients had undergone a single primary procedure at a mean of nine years previously. In group I (25 knees) the original femoral component was secure and was retained. There were no abrasions or osteolysis. The knees were stable, normally aligned, with minimal bone loss. In group II 42 knees did not fulfil these criteria and underwent revision of both components. The mean follow-up was four years. Re-revision for loosening was required in seven knees (28%) in group I and three (7%) in group II (p < 0.01). The remaining knees function well with Knee Society scores averaging 84/69 and no radiological evidence of osteolysis. When revising cemented implants, retention of a secure femoral component cannot be recommended even when conditions appear to be suitable


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 3 | Pages 407 - 411
1 May 1995
Court-Brown C Keating J Christie J McQueen M

Exchange nailing for failure of union after primary intramedullary nailing of the tibia is widely used but the indications and effectiveness have not been reported in detail. We have reviewed 33 cases of uninfected nonunion of the tibia treated by exchange nailing. This technique was successful without open bone grafting in all closed fractures and in open fractures of Gustilo types I, II and IIIa. The requirement for open bone grafting was reduced in type-IIIb fractures, but exchange nailing failed in type-IIIb fractures with significant bone loss. For these we recommend early open bone grafting. The most common complication was wound infection, seen more often than after primary nailing. We discuss our protocol for the use and timing of exchange nailing of all grades and types of tibial fracture


Bone & Joint 360
Vol. 8, Issue 5 | Pages 4 - 10
1 Oct 2019
Tsoi K Samuel A Jeys LM Ashford RU Gregory JJ


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 4 | Pages 497 - 503
1 May 2002
Hedström M åström K Sjöberg H Dalén N Sjöberg K Brosjö E

A total of 63 women who had an operation for a fracture of the hip was randomly allocated to one year of treatment either with anabolic steroids, vitamin D and calcium (anabolic group) or with calcium only (control group). The thigh muscle volume was measured by quantitative CT. The bone mineral density of the hip, femur and tibia was assessed by quantitative CT and dual-energy x-ray absorptiometry and of the heel by quantitative ultrasound. Quantitative CT showed that the anabolic group did not lose muscle volume during the first 12 months whereas the control group did (p< 0.01). There was less bone loss in the proximal tibia in the anabolic group than in the control group. The speed of gait and the Harris hip score were significantly better in the anabolic group after six and 12 months. Anabolic steroids, even in this moderate dose, given in combination with vitamin D and calcium had a beneficial effect on muscle volume, bone mineral density and clinical function in this group of elderly women


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 4 | Pages 573 - 579
1 Aug 1984
Lifeso R Al-Saati F

One hundred and sixteen patients with 129 ununited fractures were treated either by rigid internal fixation and bone grafting or, in 14 tibial non-unions, by posterolateral bone grafting. In 37 actively infected cases this was combined with sequestrectomy and appropriate antibiotics. The final success rate was 98.4%. Technical errors or inadequate immobilisation after operation in patients with severe osteoporosis led to some early failures. No patient had a discharge or evidence of osteomyelitis after removal of metal. Rigid internal fixation with or without bone grafting is the treatment of choice for established non-union with bone loss when true synovial pseudarthrosis is present, when malalignment or shortening needs correction, and when prolonged immobilisation is either difficult or would lead to unacceptable stiffness in adjacent joints. Active osteomyelitis is not a contra-indication to internal fixation


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 4 | Pages 489 - 493
1 Aug 1982
Freeman M Bradley G Revell P

The occurrence of a radiolucent line at the interface of bone and cement in total joint prostheses is a frequently observed, although little understood, phenomenon. Because of an operative technique utilised in instances of bone loss, we have, within a single implant mass used in each of a series of 18 total knee replacements, been able to observe two separate interfaces, one between bone and cement and the other between bone and cobalt chrome. The average period of observation was 32 months. All of the knees except one demonstrated a lucency at the bone-cement interface; only one of the knees had a similar lucency at the bone-CoCr interface. One of the knees was studied histologically. In the light of the universal observation of macrophages at bone-cement interfaces and the recent finding that osteoclasts are derived from macrophages, these observations are significant in relation to the aetiology of bone-cement lucencies


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 3 | Pages 378 - 383
1 Apr 2004
Herbst SA Jones KB Saltzman CL

The relationship between the bone mineral density (BMD) and Charcot arthropathy is unclear. Prospectively, 55 consecutive diabetic patients presenting with a Charcot arthropathy of the foot or ankle were classified as having a fracture, dislocation, or a combination fracture-dislocation pattern of initial destruction. In these groups we used dual-energy x-ray absorptiometry to compare the peripheral bone of the affected and unaffected limbs. The clinical data relating to diabetes and related major comorbidities and the site of the arthropathy (ankle, hindfoot, midfoot, forefoot) were also compared. There were 23 patients with a fracture pattern, 23 with a dislocation pattern, and nine with a combination. The age-adjusted odds ratio for developing a Charcot joint with a fracture pattern as opposed to a dislocation pattern in patients with osteopenia was 9.5 (95% confidence interval 2.4 to 37.4; p = 0.0014). Groups also differed as to the site of the arthropathy. Fracture patterns predominated at the ankle and forefoot whereas dislocations did so in the midfoot. Diabetic Charcot arthropathy of the foot and ankle differs according to the pattern of the initial destruction. The fracture pattern is associated with peripheral deficiency of BMD. The dislocation pattern is associated with a normal BMD


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1272 - 1279
1 Oct 2019
Nowak LL Hall J McKee MD Schemitsch EH

Aims

To compare complication-related reoperation rates following primary arthroplasty for proximal humerus fractures (PHFs) versus secondary arthroplasty for failed open reduction and internal fixation (ORIF).

Patients and Methods

We identified patients aged 50 years and over, who sustained a PHF between 2004 and 2015, from linkable datasets. We used intervention codes to identify patients treated with initial ORIF or arthroplasty, and those treated with ORIF who returned for revision arthroplasty within two years. We used multilevel logistic regression to compare reoperations between groups.


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 1 | Pages 67 - 73
1 Jan 1992
Kwong L Jasty M Mulroy R Maloney W Bragdon C Harris W

The radiographic and histological features of radiolucent areas at the cement-bone interface were correlated in 15 specimens retrieved at post-mortem from patients who had undergone cemented total hip arthroplasty, two weeks to 15 years prior to death. All but one of the components were securely fixed, as demonstrated by direct measurements of micromotion. Extensive radiolucencies were present in all but one case. In 11 of the 14 specimens with radiolucencies, histological examination showed that the radiolucent areas represented regions of osteoporosis and bone remodelling. The remodelling changes were characterised by osteoporosis, cancellisation and thinning of the endosteal cortex, and osteopenia of the trabecular bone. In two specimens the appearance of radiolucency was found to be due to fibrous tissue at the cement-bone interface and in one specimen there was a mixed picture of osteolysis and fibrosis. The study demonstrates that radiolucent lines can occur with well-fixed components and that they may commonly represent osteoporosis rather than the presence of a fibrous membrane at the cement-bone interface


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 3 | Pages 448 - 451
1 May 1991
Thakur A Patankar J

Seventy-nine open tibial fractures were treated with unilateral uniplanar tubular external fixators. Excellent stability allowed early weight-bearing. All comminuted fractures, with or without bone loss, and some transverse or short oblique fractures with intermediate fragments were treated by early bone grafting through a posterolateral approach. The external fixator was dynamised as soon as periosteal callus was seen on the radiograph. Bone healing times ranged from 11 to 40 weeks (mean 20). Significant ankle stiffness occurred in 10.9% and leg shortening in 2.8%. Pin track infection was seen in 45.2% but was easily controlled with standard management. The external fixation frame allowed excellent functional freedom for Oriental patients to sit cross-legged and squat. Combined with early bone grafting, external fixation is an excellent method for the management of open tibial fractures