Advertisement for orthosearch.org.uk
Results 421 - 440 of 670
Results per page:
Bone & Joint 360
Vol. 7, Issue 4 | Pages 12 - 15
1 Aug 2018


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 838 - 847
1 Jul 2019
Robinson PG Clement ND Hamilton D Blyth MJG Haddad FS Patton JT

Aims

Robotic-assisted unicompartmental knee arthroplasty (UKA) promises accurate implant placement with the potential of improved survival and functional outcomes. The aim of this study was to present the current evidence for robotic-assisted UKA and describe the outcome in terms of implant positioning, range of movement (ROM), function and survival, and the types of robot and implants that are currently used.

Materials and Methods

A search of PubMed and Medline was performed in October 2018 in line with the Preferred Reporting Items for Systematic Review and Meta-Analysis statement. Search terms included “robotic”, “knee”, and “surgery”. The criteria for inclusion was any study describing the use of robotic UKA and reporting implant positioning, ROM, function, and survival for clinical, cadaveric, or dry bone studies.


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 621 - 624
1 May 2019
Pumberger M Bürger J Strube P Akgün D Putzier M

Aims

During revision procedures for aseptic reasons, there remains a suspicion that failure may have been the result of an undetected subclinical infection. However, there is little evidence available in the literature about unexpected positive results in presumed aseptic revision spine surgery. The aims of our study were to estimate the prevalence of unexpected positive culture using sonication and to evaluate clinical characteristics of these patients.

Patients and Methods

All patients who underwent a revision surgery after instrumented spinal surgery at our institution between July 2014 and August 2016 with spinal implants submitted for sonication were retrospectively analyzed. Only revisions presumed as aseptic are included in the study. During the study period, 204 spinal revisions were performed for diagnoses other than infection. In 38 cases, sonication cultures were not obtained, leaving a study cohort of 166 cases. The mean age of the cohort was 61.5 years (sd 20.4) and there were 104 female patients


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 3 | Pages 371 - 373
1 May 1997
Nicolai P Aldam CH Allen PW

An intact barrier between the hands of the surgeon and the patient remains the single most important factor in protection against infection for both. Increasing the awareness of possible glove perforation without skin penetration will decrease the risk of contamination. We performed a prospective, randomised trial comparing the incidence of glove perforation using a new type of glove (Regent Biogel Reveal) and standard double-gloves in total hip and knee replacement. One or more perforations was detected in 14.6% of all gloves. The new gloves increased significantly the awareness of perforation. Multiple perforations at the base of the ring finger were found in surgeons who wore wedding rings during the operation and we recommend that rings be removed before undertaking surgery


Bone & Joint 360
Vol. 7, Issue 2 | Pages 12 - 15
1 Apr 2018


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 2 | Pages 178 - 181
1 Mar 2003
Møller AM Pedersen T Villebro N Munksgaard A

Smoking is an important risk factor for the development of postoperative pulmonary complications after major surgical procedures. We studied 811 consecutive patients who had undergone hip or knee arthroplasty, recording current smoking and drinking habits, any history of chronic disease and such intraoperative factors as the type of anaesthesia and the type and duration of surgery. We recorded any postoperative complications occurring before discharge from hospital. There were 232 smokers (28.6%) and 579 non-smokers. We found that smoking was the single most important risk factor for the development of postoperative complications, particularly those relating to wound healing, cardiopulmonary complications, and the requirement of postoperative intensive care. A delay in discharge from hospital was usual for those suffering a complication. In those patients requiring prolonged hospitalisation (> 15 days) the proportion of smokers with wound complications was twice that of non-smokers


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 582 - 588
1 May 2019
Sidhu MS Cooper G Jenkins N Jeys L Parry M Stevenson JD

Aims

The aims of this study were to report the efficacy of revision surgery for patients with co-infective bacterial and fungal prosthetic joint infections (PJIs) presenting to a single institution, and to identify prognostic factors that would guide management.

Patients and Methods

A total of 1189 patients with a PJI were managed in our bone infection service between 2006 and 2015; 22 (1.85%) with co-infective bacterial and fungal PJI were included in the study. There were nine women and 13 men, with a mean age at the time of diagnosis of 64.5 years (47 to 83). Their mean BMI was 30.9 kg/m2 (24 to 42). We retrospectively reviewed the outcomes of these PJIs, after eight total hip arthroplasties and 14 total knee arthroplasties. The mean clinical follow-up was 4.1 years (1.4 to 8.8).


Bone & Joint 360
Vol. 7, Issue 3 | Pages 10 - 12
1 Jun 2018


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 1 | Pages 116 - 118
1 Jan 2000
Best AJ Williams S Crozier A Bhatt R Gregg PJ Hui ACW

We recruited 89 patients who had hip or knee replacements to assess the performance of below-knee graded compression stockings. The pressure gradients generated by the stockings were measured and all patients had venography of the ipsilateral leg. We found that 98% of stockings failed to produce the ‘ideal’ pressure gradient (± 20%) of 18, 14 and 8 mmHg from the ankle to the knee, while 54% produced a ‘reversed gradient’ on at least one occasion during the course of the study. The overall rate of deep-venous thrombosis was 16.7%. Stockings which produced reversed gradients were associated with a significantly higher incidence of deep-venous thrombosis (p = 0.026) than those with the correct gradient (25.6% v 6.1%). This suggests that the performance of graded compression stockings can be improved if reversed pressure gradients are detected and prevented


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 241 - 248
1 Feb 2005
Pynsent PB Adams DJ Disney SP

The Oxford hip and knee scores are used to measure the outcome after primary total hip and knee replacement. We propose a new layout for the instrument in which patients are always asked about both limbs. In addition, we have defined an alternative scoring method which accounts for missing data. Over a period of 4.5 years, 4086 (1423 patients) and 5708 (1458 patients) questionnaires were completed for hips and knees, respectively. The hip score had a pre-operative median of 70.8 (interquartile range (IQR) 58.3 to 81.2) decreasing to 20.8 (IQR 10.4 to 35.4) after one year. The knee score had a pre-operative median of 68.8 (IQR 56.2 to 79.2) decreasing to 29.2 (IQR 14.6 to 45.8). There was no further significant change in either score after one year. As a result of the data analysis, we suggest that the score percentiles can be used as a standard for auditing patients before and after operation


Bone & Joint 360
Vol. 8, Issue 2 | Pages 16 - 18
1 Apr 2019


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 3 | Pages 427 - 430
1 May 1996
Dhillon KS Askander A Doraisamy S

Postoperative deep-vein thrombosis (DVT) is believed to be rare in Asians. We studied 88 consecutive patients in Malaysia who had operations for fracture of the proximal femur or for total hip or knee replacement. No patient had prophylaxis against DVT; bilateral ascending venography was performed between six and ten days after operation. A total of 55 patients (62.5%) showed venographic evidence of DVT. The prevalence was greatest after total knee replacement (76.5%), less after total hip replacement (64.3%) and smallest in the fracture group (50%). One patient developed symptomatic pulmonary embolism. In contrast to other reports from Asia, we found an incidence of postoperative DVT which is similar to that reported in Western populations. This suggests that the present practice of withholding routine prophylaxis against thromboembolism in Asian patients undergoing high-risk orthopaedic procedures should be reconsidered


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 1 | Pages 95 - 98
1 Jan 2004
Riding G Daly K Hutchinson S Rao S Lovell M McCollum C

Fat embolism occurs following fractures of a long bone or arthroplasty. We investigated whether paradoxical embolisation through a venous-to-arterial circulation shunt (v-a) could lead to cerebral embolisation during elective hip or knee arthroplasty. Transcranial Doppler ultrasound (TCD), following the intravenous injection of microbubble contrast, identified the presence of a shunt in 41 patients undergoing hip (n=20) or knee (n=21) arthroplasty. Intra-operative cerebral embolism was detected during continuous TCD monitoring. Of the 41 patients, 34 had a v-a shunt of whom 18 had an embolism and embolism only occurred in patients with a shunt (p = 0.012). Spontaneous and larger shunts were associated with a greater number of emboli (r. s. = 0.67 and r. s. = 0.71 respectively, p < 0.01). Observations in two patients with large spontaneous shunts revealed 368 and 203 emboli and unexplained post-operative confusion and pancreatitis. Paradoxical cerebral embolisation only occurred in patients with a shunt and may explain both postoperative confusion and fat embolism syndrome following surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 3 | Pages 411 - 413
1 May 1998
Sutton PM Greene T Howell FR

We performed a prospective, randomised study comparing the rates of glove perforation using double latex gloving with or without a disposable protective glove liner (Paraderm) on 118 patients undergoing primary or revision arthroplasty of the hip or knee by one surgeon (FRH). The patients were randomly allocated into two groups: in group 1 an inner and outer pair of latex gloves were worn as double gloves and in group 2 the glove liner was worn between the two latex gloves. There was glove perforation in at least one outer glove in 99 operations (84%). The operating surgeon was aware of the perforation in 21 of these. There were 22 perforations of the inner glove. Group 1 had a significantly higher perforation rate per operation (p < 0.05) than group 2. Our findings show that protective glove liners significantly reduce the rate of perforation of the inner glove during hip and knee arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 92 - 94
1 Jan 1996
Brown AR Taylor GJS Gregg PJ

Despite the use of ultraclean air, there are still cases of infection in total joint arthroplasty. One possible route by which bacteria may enter the wound is indirectly by contamination of instruments during skin preparation and draping. We found that bacterial air counts were 4.4 times higher during preparation and draping for hip or knee arthroplasty using an unscrubbed, ungowned leg holder than during the operation itself. With the leg holder scrubbed and gowned during preparation and draping, the air counts were reduced but were still 2.4 fold greater than intraoperatively. On some occasions, the air counts during preparation and draping exceeded the standards for ultraclean air irrespective of the attire of the leg holder. We recommend that the leg is held by a scrubbed and gowned member of the team. More importantly, we consider that instrument packs should be opened only after skin preparation and draping have been completed


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 5 | Pages 886 - 889
1 Sep 1999
Davis N Curry A Gambhir AK Panigrahi H Walker CRC Wilkins EGL Worsley MA Kay PR

All surgical operations have the potential for contamination, and the equipment used can harbour bacteria. We collected samples from 100 elective primary hip and knee arthroplasties. These showed rates of contamination of 11.4% for the sucker tips, 14.5% for light handles, 9.4% for skin blades and 3.2% for the inside blades used during surgery; 28.7% of gloves used for preparation were also contaminated. Of the samples taken from the collection bags used during hip arthroplasty, 20% grew bacteria, which represents a significant microbial reservoir. Also, 17% of theatre gowns were contaminated at the end of the operation. Contamination was found in 10% of the needles used during closure of the fascia. Overall, 76% of the organisms grown were coagulase-negative staphylococcus. A total of 63% of operations showed contamination in the field of operation. Some changes in practice are suggested. Follow-up for a minimum of two years revealed one deep infection but the organism was not identified as a contaminant. These data provide a baseline for studying the bacteriology of the surgery of revision arthroplasty


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 415 - 425
1 Apr 2019
Thewlis D Bahl JS Fraysse F Curness K Arnold JB Taylor M Callary S Solomon LB

Aims

The purpose of this exploratory study was to investigate if the 24-hour activity profile (i.e. waking activities and sleep) objectively measured using wrist-worn accelerometry of patients scheduled for total hip arthroplasty (THA) improves postoperatively.

Patients and Methods

A total of 51 THA patients with a mean age of 64 years (24 to 87) were recruited from a single public hospital. All patients underwent THA using the same surgical approach with the same prosthesis type. The 24-hour activity profiles were captured using wrist-worn accelerometers preoperatively and at 2, 6, 12, and 26 weeks postoperatively. Patient-reported outcomes (Hip Disability and Osteoarthritis Outcome Score (HOOS)) were collected at all timepoints except two weeks postoperatively. Accelerometry data were used to quantify the intensity (sedentary, light, moderate, and vigorous activities) and frequency (bouts) of activity during the day and sleep efficiency. The analysis investigated changes with time and differences between Charnley class.


Bone & Joint 360
Vol. 8, Issue 1 | Pages 40 - 42
1 Feb 2019


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 1005 - 1012
1 Nov 1999
Gschwend N Scheier NH Baehler AR

Between 1978 and 1986, 59 patients received a GSB III elbow prosthesis, six of them in both elbows. Rheumatoid arthritis (RA) was the underlying cause in 51 of the patients and post-traumatic osteoarthritis (PTOA) in eight. Of these, 24 patients (28 prostheses) have since died; two, both operated on bilaterally, had had their implants for more than ten years and had already been assessed for inclusion in the long-term follow-up. Two patients, each with one elbow prosthesis, have been lost to follow-up and three males who are still living (two with PTOA, one with juvenile RA) had their prosthesis removed before ten years had elapsed. The remaining 32 patients (28 RA, 4 PTOA) with 36 GSB III elbows were examined clinically and radiologically after a mean period of 13.5 years. Pain was considerably reduced in 91.6%. Mobility was increased by 37° in those with RA and by 67° in those with PTOA. There were three cases of aseptic loosening and three of deep infection. The main complication was disassembly of the prosthetic component in nine elbows (13.8%). This last group included two patients with postoperative fractures unrelated to the operative technique and one with neuropathic arthritis. Ulnar neuritis occurred in two patients. Since 87.7% of all the GSB III prostheses implanted in this period remained in situ, our results are comparable with those for hip and knee arthroplasty


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 703 - 711
1 Jun 2018
Marson BA Deshmukh SR Grindlay DJC Scammell BE

Aims

The aim of this review was to evaluate the available literature and to calculate the pooled sensitivity and specificity for the different alpha-defensin test systems that may be used to diagnose prosthetic joint infection (PJI).

Materials and Methods

Studies using alpha-defensin or Synovasure (Zimmer Biomet, Warsaw, Indiana) to diagnose PJI were identified from systematic searches of electronic databases. The quality of the studies was evaluated using the Quality Assessment of Studies of Diagnostic Accuracy (QUADAS) tool. Meta-analysis was completed using a bivariate model.