Advertisement for orthosearch.org.uk
Results 401 - 420 of 1198
Results per page:
The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1417 - 1422
1 Oct 2015
Ferreira N Marais LC Aldous C

Tibial nonunion represents a spectrum of conditions which are challenging to treat, and optimal management remains unclear despite its high rate of incidence. We present 44 consecutive patients with 46 stiff tibial nonunions, treated with hexapod external fixators and distraction to achieve union and gradual deformity correction. There were 31 men and 13 women with a mean age of 35 years (18 to 68) and a mean follow-up of 12 months (6 to 40). No tibial osteotomies or bone graft procedures were performed. Bony union was achieved after the initial surgery in 41 (89.1%) tibias. Four persistent nonunions united after repeat treatment with closed hexapod distraction, resulting in bony union in 45 (97.8%) patients. The mean time to union was 23 weeks (11 to 49). Leg-length was restored to within 1 cm of the contralateral side in all tibias. Mechanical alignment was restored to within 5° of normal in 42 (91.3%) tibias. Closed distraction of stiff tibial nonunions can predictably lead to union without further surgery or bone graft. In addition to generating the required distraction to achieve union, hexapod circular external fixators can accurately correct concurrent deformities and limb-length discrepancies.

Cite this article: Bone Joint J 2015;97-B:1417–22.


The early failure and revision of bimodular primary total hip arthroplasty prostheses requires the identification of the risk factors for material loss and wear at the taper junctions through taper wear analysis. Deviations in taper geometries between revised and pristine modular neck tapers were determined using high resolution tactile measurements. A new algorithm was developed and validated to allow the quantitative analysis of material loss, complementing the standard visual inspection currently used.

The algorithm was applied to a sample of 27 retrievals (in situ from 2.9 to 38.1 months) of the withdrawn Rejuvenate modular prosthesis. The mean wear volumes on the flat distal neck piece taper was 3.35 mm3 (0.55 to 7.57), mainly occurring in a characteristic pattern in areas with high mechanical loading. Wear volume tended to increase with time to revision (r² = 0.423, p = 0.001). Implant and patient specific data (offset, stem size, patient’s mass, age and body mass index) did not correlate with the amount of material loss observed (p >  0.078). Bilaterally revised implants showed higher amounts of combined total material loss and similar wear patterns on both sides. The consistent wear pattern found in this study has not been reported previously, suggesting that the device design and materials are associated with the failure of this prosthesis.

Cite this article: Bone Joint J 2015;97-B:1350–7.


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1328 - 1337
1 Oct 2015
Briant-Evans TW Lyle N Barbur S Hauptfleisch J Amess R Pearce AR Conn KS Stranks GJ Britton JM

We investigated the changes seen on serial metal artefact reduction magnetic resonance imaging scans (MARS-MRI) of metal-on-metal total hip arthroplasties (MoM THAs). In total 155 THAs, in 35 male and 100 female patients (mean age 70.4 years, 42 to 91), underwent at least two MRI scans at a mean interval of 14.6 months (2.6 to 57.1), at a mean of 48.2 months (3.5 to 93.3) after primary hip surgery. Scans were graded using a modification of the Oxford classification. Progression of disease was defined as an increase in grade or a minimum 10% increase in fluid lesion volume at second scan. A total of 16 hips (30%) initially classified as ‘normal’ developed an abnormality on the second scan. Of those with ‘isolated trochanteric fluid’ 9 (47%) underwent disease progression, as did 7 (58%) of ‘effusions’. A total of 54 (77%) of hips initially classified as showing adverse reactions to metal debris (ARMD) progressed, with higher rates of progression in higher grades. Disease progression was associated with high blood cobalt levels or an irregular pseudocapsule lining at the initial scan. There was no association with changes in functional scores. Adverse reactions to metal debris in MoM THAs may not be as benign as previous reports have suggested. Close radiological follow-up is recommended, particularly in high-risk groups.

Cite this article: Bone Joint J 2015;97-B:1328–37.


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1358 - 1363
1 Oct 2015
Hooper N Snell D Hooper G Maxwell R Frampton C

This study reports on the first 150 consecutive Oxford cementless unicompartmental knee arthroplasties (UKA) performed in an independent centre (126 patients). All eligible patients had functional scores (Oxford knee score and high activity arthroplasty score) recorded pre-operatively and at two- and five-years of follow-up. Fluoroscopically aligned radiographs were taken at five years and analysed for any evidence of radiolucent lines (RLLs), subsidence or loosening. The mean age of the cohort was 63.6 years (39 to 86) with 81 (53.1%) males. Excellent functional scores were maintained at five years and there were no progressive RLLs demonstrated on radiographs. Two patients underwent revision to a total knee arthroplasty giving a revision rate of 0.23/100 (95% confidence interval 0.03 to 0.84) component years with overall component survivorship of 98.7% at five years. There were a further four patients who underwent further surgery on the same knee, two underwent bearing exchanges for dislocation and two underwent lateral UKAs for disease progression. This was a marked improvement from other UKAs reported in New Zealand Joint Registry data and supports the designing centre’s early results.

Cite this article: Bone Joint J 2015;97-B:1358–63.


The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1296 - 1300
1 Sep 2015
Jauregui JJ Bor N Thakral R Standard SC Paley D Herzenberg JE

External fixation is widely used in orthopaedic and trauma surgery. Infections around pin or wire sites, which are usually localised, non-invasive, and are easily managed, are common. Occasionally, more serious invasive complications such as necrotising fasciitis (NF) and toxic shock syndrome (TSS) may occur.

We retrospectively reviewed all patients who underwent external fixation between 1997 and 2012 in our limb lengthening and reconstruction programme. A total of eight patients (seven female and one male) with a mean age of 20 years (5 to 45) in which pin/wire track infections became limb- or life-threatening were identified. Of these, four were due to TSS and four to NF. Their management is described. A satisfactory outcome was obtained with early diagnosis and aggressive medical and surgical treatment.

Clinicians caring for patients who have external fixation and in whom infection has developed should be aware of the possibility of these more serious complications. Early diagnosis and aggressive treatment are required in order to obtain a satisfactory outcome.

Cite this article: Bone Joint J 2015;97-B:1296–1300.


The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1226 - 1231
1 Sep 2015
Nakamura R Komatsu N Murao T Okamoto Y Nakamura S Fujita K Nishimura H Katsuki Y

The objective of this study was to validate the efficacy of Takeuchi classification for lateral hinge fractures (LHFs) in open wedge high tibial osteotomy (OWHTO). In all 74 osteoarthritic knees (58 females, 16 males; mean age 62.9 years, standard deviation 7.5, 42 to 77) were treated with OWHTO using a TomoFix plate. The knees were divided into non-fracture (59 knees) and LHF (15 knees) groups, and the LHF group was further divided into Takeuchi types I, II, and III (seven, two, and six knees, respectively). The outcomes were assessed pre-operatively and one year after OWHTO. Pre-operative characteristics (age, gender and body mass index) showed no significant difference between the two groups. The mean Japanese Orthopaedic Association score was significantly improved one year after operation regardless of the presence or absence of LHF (p = 0.0015, p < 0.001, respectively). However, six of seven type I cases had no LHF-related complications; both type II cases had delayed union; and of six type III cases, two had delayed union with correction loss and one had overcorrection. These results suggest that Takeuchi type II and III LHFs are structurally unstable compared with type I.

Cite this article: Bone Joint J 2015;97-B:1226–31.


The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1279 - 1283
1 Sep 2015
Mahale YJ Aga N

In this retrospective observational cohort study, we describe 17 patients out of 1775 treated for various fractures who developed mycobacterium tuberculosis (MTB) infection after surgery. The cohort comprised 15 men and two women with a mean age of 40 years (24 to 70). A total of ten fractures were open and seven were closed. Of these, seven patients underwent intramedullary nailing of a fracture of the long bone, seven had fractures fixed with plates, two with Kirschner-wires and screws, and one had a hemiarthroplasty of the hip with an Austin Moore prosthesis. All patients were followed-up for two years. In all patients, the infection resolved, and in 14 the fractures united. Nonunion was seen in two patients one of whom underwent two-stage total hip arthroplasty (THA) and the other patient was treated using excision arthoplasty. Another patient was treated using two-stage THA. With only sporadic case reports in the literature, MTB infection is rarely clinically suspected, even in underdeveloped and developing countries, where pulmonary and other forms of TB are endemic. In developed countries there is also an increased incidence among immunocompromised patients. In this paper we discuss the pathogenesis and incidence of MTB infection after surgical management of fractures and suggest protocols for early diagnosis and management.

Cite this article: Bone Joint J 2015;97-B:1279–83.


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1111 - 1117
1 Aug 2015
Chiu CK Kwan MK Chan CYW Schaefer C Hansen-Algenstaedt N

We undertook a retrospective study investigating the accuracy and safety of percutaneous pedicle screws placed under fluoroscopic guidance in the lumbosacral junction and lumbar spine. The CT scans of patients were chosen from two centres: European patients from University Medical Center Hamburg-Eppendorf, Germany, and Asian patients from the University of Malaya, Malaysia. Screw perforations were classified into grades 0, 1, 2 and 3. A total of 880 percutaneous pedicle screws from 203 patients were analysed: 614 screws from 144 European patients and 266 screws from 59 Asian patients. The mean age of the patients was 58.8 years (16 to 91) and there were 103 men and 100 women. The total rate of perforation was 9.9% (87 screws) with 7.4% grade 1, 2.0% grade 2 and 0.5% grade 3 perforations. The rate of perforation in Europeans was 10.4% and in Asians was 8.6%, with no significant difference between the two (p = 0.42). The rate of perforation was the highest in S1 (19.4%) followed by L5 (14.9%). The accuracy and safety of percutaneous pedicle screw placement are comparable to those cited in the literature for the open method of pedicle screw placement. Greater caution must be taken during the insertion of L5 and S1 percutaneous pedicle screws owing to their more angulated pedicles, the anatomical variations in their vertebral bodies and the morphology of the spinal canal at this location.

Cite this article: Bone Joint J 2015; 97-B:1111–17.


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1096 - 1101
1 Aug 2015
Oizumi N Suenaga N Yoshioka C Yamane S

To prevent insufficiency of the triceps after total elbow arthroplasty, we have, since 2008, used a triceps-sparing ulnar approach. This study evaluates the clinical results and post-operative alignment of the prosthesis using this approach.

We reviewed 25 elbows in 23 patients. There were five men and 18 women with a mean age of 69 years (54 to 83). There were 18 elbows with rheumatoid arthritis, six with a fracture or pseudoarthrosis and one elbow with osteoarthritis.

Post-operative complications included one intra-operative fracture, one elbow with heterotopic ossification, one transient ulnar nerve palsy, and one elbow with skin necrosis, but no elbow was affected by insufficiency of the triceps.

Patients were followed for a mean of 42 months (24 to 77). The mean post-operative Japanese Orthopaedic Association Elbow Score was 90.8 (51 to 100) and the mean Mayo Elbow Performance score 93.8 (65 to 100). The mean post-operative flexion/extension of the elbow was 135°/-8°. The Manual Muscle Testing score of the triceps was 5 in 23 elbows and 2 in two elbows (one patient). The mean alignment of the implants examined by 3D-CT was 2.8° pronation (standard deviation (sd) 5.5), 0.3° valgus (sd 2.7), and 0.7° extension (sd 3.2) for the humeral component, and 9.3° pronation (sd 9.7), 0.3° valgus (sd 4.0), and 8.6° extension (sd 3.1) for the ulnar component. There was no radiolucent line or loosening of the implants on the final radiographs.

The triceps-sparing ulnar approach allows satisfactory alignment of the implants, is effective in preventing post-operative triceps insufficiency, and gives satisfactory short-term results.

Cite this article: 2015;97-B:1096–1101.


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1090 - 1095
1 Aug 2015
Urita A Funakoshi T Suenaga N Oizumi N Iwasaki N

This pilot study reports the clinical outcomes of a combination of partial subscapularis tendon transfer and small-head hemiarthroplasty in patients with rotatator cuff arthropathy. A total of 30 patients (30 shoulders; eight men and 22 women) with a mean age of 74 years (55 to 84) were assessed at a mean follow-up of 31 months (24 to 60). The inclusion criteria were painful cuff tear arthropathy with normal deltoid function and a non-degenerative subscapularis muscle and tendon and a preserved teres minor.

Outcome was assessed using the University of California Los Angeles score, the Japanese Orthopaedic Association score, and the Oxford Shoulder Score. Radiographic measurements included the centre of rotation distance and the length of the deltoid.

All clinical scores were significantly improved post-operatively. The active flexion and external rotation improved significantly at the most recent follow-up (p < 0.035). Although the mean centre of rotation distance changed significantly (p < 0.001), the mean length of the deltoid did not change significantly from the pre-operative value (p = 0.29). The change in the length of the deltoid with < 100° flexion was significantly less than that with > 100° (p < 0.001).

Progressive erosion of the glenoid was seen in four patients. No patient required revision or further surgery.

A combination of partial subscapularis tendon transfer and small-head hemiarthroplasty effectively restored function and relieved pain in patients with rotator cuff arthropathy.

Cite this article: 2015;97-B:1090–5.


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 1004 - 1006
1 Jul 2015
Middleton SD McNiven N Griffin EJ Anakwe RE Oliver CW

We define the long-term outcomes and rates of further operative intervention following displaced Bennett’s fractures treated with Kirschner (K-) wire fixation between 1996 and 2009. We retrospectively identified 143 patients (127 men and 16 women) with a mean age at the time of injury of 33.2 years (18 to 75). Electronic records were examined and patients were invited to complete the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire in addition to a satisfaction questionnaire. The time since injury was a mean of 11.5 years (3.4 to 18.5). In total 11 patients had died, one had developed dementia and 12 patients were lost to follow-up. This left 119 patients available for recruitment. Of these, 57 did not respond, leaving a study group of 62 patients. Patients reported excellent functional outcomes and high levels of satisfaction at follow-up. Median satisfaction was 94% (interquartile range 91.5 to 97.5) and the mean DASH score was 3.0 (0 to 38). None of the patients had undergone salvage procedures and none of the responders had changed occupation or sporting activities. Long-term patient reported outcomes following displaced Bennett’s fractures treated by closed reduction and K-wire fixation show excellent functional results and a high level of patient satisfaction. The rate of infection is low and similar to other surgical procedures with percutaneous K-wires.

Cite this article: Bone Joint J 2015;97-B:1004–6.


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 871 - 874
1 Jul 2015
Breakwell LM Cole AA Birch N Heywood C

The effective capture of outcome measures in the healthcare setting can be traced back to Florence Nightingale’s investigation of the in-patient mortality of soldiers wounded in the Crimean war in the 1850s.

Only relatively recently has the formalised collection of outcomes data into Registries been recognised as valuable in itself.

With the advent of surgeon league tables and a move towards value based health care, individuals are being driven to collect, store and interpret data.

Following the success of the National Joint Registry, the British Association of Spine Surgeons instituted the British Spine Registry. Since its launch in 2012, over 650 users representing the whole surgical team have registered and during this time, more than 27 000 patients have been entered onto the database.

There has been significant publicity regarding the collection of outcome measures after surgery, including patient-reported scores. Over 12 000 forms have been directly entered by patients themselves, with many more entered by the surgical teams.

Questions abound: who should have access to the data produced by the Registry and how should they use it? How should the results be reported and in what forum?

Cite this article: Bone Joint J 2015;97-B:871–4.


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 883 - 889
1 Jul 2015
Jassim SS Patel S Wardle N Tahmassebi J Middleton R Shardlow DL Stephen A Hutchinson J Haddad FS

Oxidised zirconium (OxZi) has been developed as an alternative bearing surface for femoral heads in total hip arthroplasty (THA). This study has investigated polyethylene wear, functional outcomes and complications, comparing OxZi and cobalt–chrome (CoCr) as part of a three-arm, multicentre randomised controlled trial. Patients undergoing THA from four institutions were prospectively randomised into three groups. Group A received a CoCr femoral head and highly cross-linked polyethylene (XLPE) liner; Group B received an OxZi femoral head and XLPE liner; Group C received an OxZi femoral head and ultra-high molecular weight polyethylene (UHMWPE) liner. At five years, 368 patients had no statistically significant differences in short-form-36 (p = 0.176 mental, p = 0.756 physical), Western Ontario and McMaster Universities Osteoarthritis Index (p = 0.847), pain scores (p = 0.458) or complications. The mean rate of linear wear was 0.028 mm/year (standard deviation (sd) 0.010) for Group A, 0.023 mm/year (sd 0.010) for Group B, and 0.09 mm/year (sd 0.045) for Group C. Penetration was significantly higher in the UHMWPE liner group compared with both XLPE liner groups (p < 0.001) but no significant difference was noted between CoCr and OxZi when articulating with XLPE (p = 0.153). In this, the largest randomised study of this bearing surface, it appears that using a XLPE acetabular liner is more important in reducing THA component wear than the choice of femoral head bearing, at mid-term follow-up. There is a non-significant trend towards lower wear, coupling OxZi rather than CoCr with XLPE but long-term analysis is required to see if this observation changes with time and becomes significant.

Cite this article: Bone Joint J 2015;97-B:883–9.


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 749 - 754
1 Jun 2015
Syed MA Hutt NJ Shah N Edge AJ

This study reports the results of 38 total hip arthroplasties (THAs) in 33 patients aged <  50 years, using the JRI Furlong hydroxyapatite ceramic (HAC)-coated femoral component. This represents an update of previous reports of the same cohort at ten and 16 years, which were reported in 2004 and 2009, respectively. We describe the survival, radiological and functional outcomes at a mean follow-up of 21 years (17 to 25). Of the surviving 34 THAs, one underwent femoral revision for peri-prosthetic fracture after 21 years, and one patient (one hip) was lost to follow-up. Using aseptic loosening as the end-point, 12 hips (31.5%) needed acetabular revision but none needed femoral revision, demonstrating 100% survival (95% confidence interval 89 to 100).

In young patients with high demands, the Furlong HAC–coated femoral component gives excellent long-term results.

Cite this article: Bone Joint J 2015;97-B:749–54.


Bone & Joint Research
Vol. 4, Issue 6 | Pages 93 - 98
1 Jun 2015
Smith NA Achten J Parsons N Wright D Parkinson B Thompson P Hutchinson CE Spalding T Costa ML

Objectives

Subtotal or total meniscectomy in the medial or lateral compartment of the knee results in a high risk of future osteoarthritis. Meniscal allograft transplantation has been performed for over thirty years with the scientifically plausible hypothesis that it functions in a similar way to a native meniscus. It is thought that a meniscal allograft transplant has a chondroprotective effect, reducing symptoms and the long-term risk of osteoarthritis. However, this hypothesis has never been tested in a high-quality study on human participants. This study aims to address this shortfall by performing a pilot randomised controlled trial within the context of a comprehensive cohort study design.

Methods

Patients will be randomised to receive either meniscal transplant or a non-operative, personalised knee therapy program. MRIs will be performed every four months for one year. The primary endpoint is the mean change in cartilage volume in the weight-bearing area of the knee at one year post intervention. Secondary outcome measures include the mean change in cartilage thickness, T2 maps, patient-reported outcome measures, health economics assessment and complications.


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 741 - 748
1 Jun 2015
Bonnin MP Neto CC Aitsiselmi T Murphy CG Bossard N Roche S

The aim of this study was to investigate the relationship between the geometry of the proximal femur and the incidence of intra-operative fracture during uncemented total hip arthroplasty (THA).

We studied the pre-operative CT scans of 100 patients undergoing THA with an uncemented femoral component. We measured the anteroposterior and mediolateral dimensions at the level of division of the femoral neck to calculate the aspect ratio of the femur. Wide variations in the shape of the femur were observed, from round, to very narrow elliptic. The femurs of women were narrower than those of men (p < 0.0001) and small femurs were also narrower than large ones. Patients with an intra-operative fracture of the calcar had smaller and narrower femurs than those without a fracture (p < 0.05) and the implanted Corail stems were smaller in those with a fracture (mean size 9 vs 12, p < 0.0001).

The variability of the shape of the femoral neck at the level of division contributes to the understanding of the causation of intra-operative fractures in uncemented THA.

Cite this article: Bone Joint J 2015;97-B:741–8.


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 802 - 808
1 Jun 2015
Kodama N Takemura Y Ueba H Imai S Matsusue Y

A new method of vascularised tibial grafting has been developed for the treatment of avascular necrosis (AVN) of the talus and secondary osteoarthritis (OA) of the ankle. We used 40 cadavers to identify the vascular anatomy of the distal tibia in order to establish how to elevate a vascularised tibial graft safely. Between 2008 and 2012, eight patients (three male, five female, mean age 50 years; 26 to 68) with isolated AVN of the talus and 12 patients (four male, eight female, mean age 58 years; 23 to 76) with secondary OA underwent vascularised bone grafting from the distal tibia either to revascularise the talus or for arthrodesis. The radiological and clinical outcomes were evaluated at a mean follow-up of 31 months (24 to 62). The peri-malleolar arterial arch was confirmed in the cadaveric study. A vascularised bone graft could be elevated safely using the peri-malleolar pedicle. The clinical outcomes for the group with AVN of the talus assessed with the mean Mazur ankle grading scores, improved significantly from 39 points (21 to 48) pre-operatively to 81 points (73 to 90) at the final follow-up (p = 0.01). In all eight revascularisations, bone healing was obtained without progression to talar collapse, and union was established in 11 of 12 vascularised arthrodeses at a mean follow-up of 34 months (24 to 58). MRI showed revascularisation of the talus in all patients.

We conclude that a vascularised tibial graft can be used both for revascularisation of the talus and for the arthrodesis of the ankle in patients with OA secondary to AVN of the talus.

Cite this article: Bone Joint J 2015; 97-B:802–8.


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 681 - 688
1 May 2015
Wagener ML de Vos MJ Hannink G van der Pluijm M Verdonschot N Eygendaal D

Unlinked, linked and convertible total elbow arthroplasties (TEAs) are currently available. This study is the first to report the clinical results of the convertible Latitude TEA. This was a retrospective study of a consecutive cohort of 63 patients (69 primary TEAs) with a mean age of 60 years (23 to 87). Between 2006 and 2008 a total of 19 men and 50 women underwent surgery. The mean follow-up was 43 months (8 to 84). The range of movement, function and pain all improved six months post-operatively and either continued to improve slightly or reached a plateau thereafter. The complication rate is similar to that reported for other TEA systems. No loosening was seen. Remarkable is the disengagement of the radial head component in 13 TEAs (31%) with a radial head component implanted.

Implantation of both the linked and the unlinked versions of the Latitude TEA results in improvement of function and decreased pain, and shows high patient satisfaction at mid-term follow-up.

Cite this article: Bone Joint J 2015; 97-B:681–8.


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 711 - 715
1 May 2015
Xie C Whalley N Adasonla K Grimer R Jeys L

The purpose of this study was to evaluate the long-term outcome of patients with a sacral chordoma and the surgical management of locally recurrent disease.

Between October 1990 and August 2013 we operated on 54 consecutive patients with a sacral chordoma. There were 34 men and 20 women with a mean age of 60 years (25 to 86). The mean maximum diameter of the tumour was 9.3 cm (3 to 20).

The mean follow-up was 7.8 years (2 months to 23.4 years). The disease-specific survival was 82% at five years, 57% at ten years and 45% at 15 years. The local recurrence-free survival was 49% at five years, 37% at ten years and 20% at 15 years. Local recurrence occurred in 30 patients (56%) at a mean of 3.8 years (3 months to 13 years) post-operatively.

Survival after the treatment of recurrence was 89% at two years, 56% at five years and 19% at ten years. Of nine patients who had complete resection of a recurrence, one died after 72 months and eight remain disease-free. Incomplete resection of recurrent disease resulted in a survival of 54% at two years and 36% at five years.

For 12 patients with a local recurrence who were treated palliatively, survival was 81% at two years and 31% at five years.

A wide margin of resection gave the best chance of long-term survival and complete resection of local recurrence the best chance of control of disease.

Cite this article: Bone Joint J 2015;97-B:711–15.


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 649 - 653
1 May 2015
Hawi N Kendoff D Citak M Gehrke T Haasper C

Knee arthrodesis is a potential salvage procedure for limb preservation after failure of total knee arthroplasty (TKA) due to infection. In this study, we evaluated the outcome of single-stage knee arthrodesis using an intramedullary cemented coupled nail without bone-on-bone fusion after failed and infected TKA with extensor mechanism deficiency. Between 2002 and 2012, 27 patients (ten female, 17 male; mean age 68.8 years; 52 to 87) were treated with septic single-stage exchange. Mean follow-up duration was 67.1months (24 to 143, n = 27) (minimum follow-up 24 months) and for patients with a minimum follow-up of five years 104.9 (65 to 143,; n = 13). A subjective patient evaluation (Short Form (SF)-36) was obtained, in addition to the Visual Analogue Scale (VAS). The mean VAS score was 1.44 (SD 1.48). At final follow-up, four patients had recurrent infections after arthrodesis (14.8%). Of these, three patients were treated with a one-stage arthrodesis nail exchange; one of the three patients had an aseptic loosening with a third single-stage exchange, and one patient underwent knee amputation for uncontrolled sepsis at 108 months. All patients, including the amputee, indicated that they would choose arthrodesis again. Data indicate that a single-stage knee arthrodesis offers an acceptable salvage procedure after failed and infected TKA.

Cite this article: Bone Joint J 2015;97-B:649–53.