1 . In the common type of Volkmann's ischaemic contracture affecting the forearm flexors, the infarct takes the form of an ellipsoid with its axis in the line of the anterior interosseous artery and with its central point a little above the middle of the forearm. The greatest damage is at the centre and usually falls most heavily on flexor digitorum profundus and flexor pollicis longus, which are often necrotic. Those muscles more superficially placed, and sometimes the deep extensors, are more likely to exhibit fibrosis. 2. The median nerve runs near the centre of the ellipsoid and may exhibit profound ischaemia. The ulnar nerve, lying at the edge of the ischaemic zone, tends to be less severely affected. 3. The
Hinged casts and roller traction were used in two developing countries to treat fractured femora, most of which were due to road traffic accidents or civil violence. This method of
A method of
The case histories of 361 subcapital fractures of the femoral neck in 354 patients treated by primary replacement with the cemented Thompson prosthesis were reviewed, and 156 survivors were seen at follow-up. The average age was eighty-one years. Three hundred and thirty fractures occurred in women and thirty-one in men. The antero-lateral approach to the hip was used at all operations because it allows immediate and unrestricted mobilisation after operation. It is considered that this method is the best
1. The results of fifty-three operations in forty adults with a persistent congenital dislocation of the hip have been reviewed. 2. Arthrodesis as a primary operation was successful in five of six patients, giving a pain-free hip and good function. After an arthroplasty or an osteotomy that had failed to relieve symptoms it was successful in only one patient. 3. Cup arthroplasty on one hip relieved pain in five of nine patients, giving an increase in functional activity, although the range of hip movement was often disappointing. Bilateral cup arthroplasty, performed in four patients, gave partial relief in three, but did not permit an increase in activity. 4. High osteotomy of the femur was undertaken in eleven patients with a unilateral dislocation; pain was rarely relieved, and a stiff hip resulted in seven. 5. Low osteotomy in nine patients gave some relief from pain with a good range of hip movement. 6. In unilateral dislocation arthrodesis appeared to be the operation of choice, although cup arthroplasty was capable of giving a good functional result. 7. In bilateral dislocation, when only one hip was painful, the results of both these operations were on the whole good. When both hips were painful the operations that had been performed seldom gave clinical improvement. 8. High osteotomy of the femur appeared to have little place in the
The medical
We report the results of a three-year study of bifocal fractures of the tibia and fibula, excluding segmental shaft fractures. In our whole series, these formed 4.7% of all tibial diaphyseal fractures. We describe three groups: bifocal fractures of both the proximal and the distal joint surfaces, fractures of the shaft and tibial plateau, and fractures of the shaft and ankle. These groups of fractures had different characteristics and prognoses. We discuss
This study aimed to evaluate the use of pin leverage in the reduction of Gartland type III supracondylar fractures of the humerus in children. The study comprised 95 children, who were split into three groups according to the type of method of reduction used. Group 1, had an open reduction, group 2, had closed reduction and percutaneous pin fixation and group 3, the pin leverage technique. Each group was analysed according to the time to surgery, the duration of the procedure, the incidence of complications, and the clinical and radiological outcome. The mean duration of the operative procedure in groups 1, 2 and 3 was 119 minutes (80 to 235), 57 minutes (20 to 110) and 68 minutes (30 to 90), respectively. At a mean follow-up of 30 months (12 to 63) the clinical results were declared excellent or good in all children and the radiological results intermediate in five patients in group 2. The results of the closed reduction using the pin leverage technique was classified as failure in two children. Our findings lead us to believe that the pin leverage method of reduction gives good results in the
1. In chronic osteomyelitis grafting a cavity with split skin is a reliable method of
1. Congenital dislocation of the hip can be diagnosed clinically immediately after birth and the diagnosis confirmed radiologically by a special technique. 2. If the affected joint is reduced during the first two or three days after birth and held reduced for a period not exceeding three months, the joint will remain stable. 3. This
1. Cancellous bone grafting of the head of the femur in Perthes' disease accelerates reossification and thus shortens the period of
1. It is suggested that replacement of the costo-clavicular ligament is mechanically an essential part of the operative
1. Paraplegia from fracture-dislocation at the thoraco-lumbar junction is a mixed cord and root injury. The root damage can be distinguished from cord damage by neurological examination and by comparison of the neurological level with the fracture level. 2. Even though the cord injury is complete, as it usually is, the roots often escape or recover. 3. Fracture-dislocations can be divided into stable and unstable types. Because of the possibility of root recovery care must be taken to prevent further damage to the roots by manipulation of the spine or during
1. The results of
All tibial shaft fractures treated at one hospital during a five-year period were studied in a prospective trial. Ninety-one displaced fractures in adults were treated using a conservative policy that included early bone grafting when indicated. Sound bony union was obtained in all cases. Those that healed primarily took on average 16.3 weeks whereas the 24 per cent that required bone grafts took 35.1 weeks. The number of complications, most of which were minor, was considered acceptable. It is concluded that provided early bone grafting is performed when necessary, a basically conservative policy of
We report a prospective study of 49 patients who had arthroscopic subacromial decompression for chronic rotator-cuff impingement. All patients were assessed preoperatively and at 3, 6 and 12 months using the modified UCLA shoulder score. The dominant arm was affected in 35 patients, but only 13 recognised overuse as a cause of their shoulder pain. Before operation, the UCLA shoulder score was poor or fair in all patients. After three months only 28% of patients had satisfactory relief of symptoms but at one year 85% of patients examined had a good or excellent result. Patients with calcific tendonitis recovered more quickly: 93% reported a good result at six months. We conclude that arthroscopic subacromial decompression is an effective form of
Twenty-two patients with ulnar nerve palsy at the elbow, confirmed by electromyography, were treated by a night splint which prevented flexion of the elbow beyond 60 degrees. The splint was worn all night regularly for at least six months. At a mean follow-up of 11.3 months, 17 patients had clinical and electromyographic assessment and five were contacted by telephone. There was improvement in the symptoms in every patient, including three who had failed to respond to surgical decompression. There was electromyographic improvement in 16 of the 17 patients re-examined at follow-up. The mean improvement in motor nerve conduction velocity was 6.5 m/s and in sensory nerve conduction velocity 9.5 m/s. The efficacy of this
This paper describes a simple method for the recording of rib deformity in idiopathic scoliosis. The relationships have been recorded between the measured rib hump and rib depression deformities and 1) the rotation of the vertebral bodies (as measured by the method of Nash and Moe on the standing radiograph); 2) the degree of lateral curvature (as measured by the method of Cobb on the standing radiograph); and 3) the rib-vertebra angles and their differences (as described by Mehta). No clear linear relationships were found. Many examples of irregular relationship were recorded, for example, marked spinal rotation with minimal rib hump. The response of the rib deformities to
Between 1989 and 1993 we implanted a matrix support prosthesis made of carbon fibre for the
The