Debate has raged over whether a cruciate retaining
(CR) or a posterior stabilised (PS) total knee replacement (TKR) provides
a better range of movement (ROM) for patients. Various sub-sets
of CR design are frequently lumped together when comparing outcomes.
Additionally, multiple factors have been proven to influence the
rate of manipulation under anaesthetic (MUA) following TKR. The
purpose of this study was to determine whether different CR bearing
insert designs provide better ROM or different MUA rates. All primary
TKRs performed by two surgeons between March 2006 and March 2009
were reviewed and 2449 CR-TKRs were identified. The same CR femoral
component, instrumentation, and tibial base plate were consistently
used. In 1334 TKRs a CR tibial insert with 3° posterior slope and
no posterior lip was used (CR-S). In 803 there was an insert with
no slope and a small posterior lip (CR-L) and in 312 knees the posterior
cruciate ligament (PCL) was either resected or lax and a deep-dish,
anterior stabilised insert was used (CR-AS). More CR-AS inserts
were used in patients with less pre-operative ROM and greater pre-operative
tibiofemoral deformity and flexion contracture (p <
0.05). The
mean improvement in ROM was highest for the CR-AS inserts (5.9°
(-40° to 55°) Cite this article:
There have been comparatively few studies of the incidence of osteolysis and the survival of hybrid and cementless total hip replacements (THRs) in patients younger than 50 years of age. We prospectively reviewed 78 patients (109 hips) with a hybrid THR having a mean age of 43.4 years (21 to 50) and 79 patients (110 hips) with a cementless THR with a mean age of 46.8 years (21 to 49). The patients were evaluated clinically using the Harris hip score, the Western Ontario and McMaster Universities (WOMAC) osteoarthritis score and the University of California, Los Angeles (UCLA) activity score. Radiographs and CT scans were assessed for loosening and osteolysis. The mean follow-up was for 18.4 years (16 to 19) in both groups. The mean post-operative Harris hip scores (91 points Although the long-term fixation of the acetabular metallic shell and the cemented and cementless femoral components was outstanding, wear and peri-acetabular osteolysis constitute the major challenges of THR in young patients.
The spinal manifestations of neurofibromatosis include cervicothoracic kyphosis, in which scalloping of the vertebral body and erosion of the pedicles may render conventional techniques of fixation impossible. We describe a case of cervicothoracic kyphosis managed operatively with a vascularised fibular graft anteriorly across the apex of the kyphus, followed by a long posterior construct using translaminar screws, which allow segmental fixation in vertebral bodies where placement of the pedicle screws was impracticable.
We describe the technique and results of medial
submuscular plating of the femur in paediatric patients and discuss its
indications and limitations. Specifically, the technique is used
as part of a plate-after-lengthening strategy, where the period
of external fixation is reduced and the plate introduced by avoiding
direct contact with the lateral entry wounds of the external fixator
pins. The technique emphasises that vastus medialis is interposed
between the plate and the vascular structures. A total of 16 patients (11 male and five female, mean age 9.6
years (5 to 17)), had medial submuscular plating of the femur. All
underwent distraction osteogenesis of the femur with a mean lengthening
of 4.99 cm (3.2 to 12) prior to plating. All patients achieved consolidation
of the regenerate without deformity. The mean follow-up was 10.5 months
(7 to 15) after plating for those with plates still Placing the plate on the medial side is advantageous when the
external fixator is present on the lateral side, and is biomechanically
optimal in the presence of a femoral defect. We conclude that medial
femoral submuscular plating is a useful technique for specific indications
and can be performed safely with a prior understanding of the regional
anatomy. Cite this article:
Our aim was to compare polylevolactic acid screws
with titanium screws when used for fixation of the distal tibiofibular
syndesmosis at mid-term follow-up. A total of 168 patients, with
a mean age of 38.5 years (18 to 72) who were randomly allocated
to receive either polylevolactic acid (n = 86) or metallic (n =
82) screws were included. The Baird scoring system was used to assess
the overall satisfaction and functional recovery post-operatively.
The demographic details and characteristics of the injury were similar
in the two groups. The mean follow-up was 55.8 months (48 to 66).
The Baird scores were similar in the two groups at the final follow-up.
Patients in the polylevolactic acid group had a greater mean dorsiflexion
(p = 0.011) and plantar-flexion of the injured ankles (p <
0.001).
In the same group, 18 patients had a mild and eight patients had
a moderate foreign body reaction. In the metallic groups eight had
mild and none had a moderate foreign body reaction (p <
0.001).
In total, three patients in the polylevolactic acid group and none
in the metallic group had heterotopic ossification (p = 0.246). We conclude that both screws provide adequate fixation and functional
recovery, but polylevolactic acid screws are associated with a higher
incidence of foreign body reactions. Cite this article:
In order to determine the epidemiology of adult scoliosis in the elderly and to analyse the radiological parameters and symptoms related to adult scoliosis, we carried out a prospective cross-sectional radiological study on 1347 adult volunteers. There were 615 men and 732 women with a mean age of 73.3 years (60 to 94), and a mean Cobb angle of 7.55° ( In our study, 478 subjects met the definition of scoliosis (Cobb angle ≥10°) showing a prevalence of 35.5%. There was a significant difference in the epidemiological distribution and prevalence between the age and gender groups. The older adults showed a larger prevalence and more severe scoliosis, more prominent in women (p = 0.004). Women were more affected by adult scoliosis and showed more linear correlation with age (p <
0.001). Symptoms were more severe in those with scoliosis than in the normal group, but were similar between the mild, moderate and severe scoliosis groups (p = 0.224) and between men and women (p = 0.231). Adult scoliosis showed a significant relationship with lateral listhesis, vertebral rotation, lumbar hypolordosis, sagittal imbalance and a high level of the L4–5 disc (p <
0.0001, p <
0.0001, p = 0.002, p = 0.002, p <
0.0001 respectively). Lateral listhesis, lumbar hypolordosis and sagittal imbalance were related to symptoms (p <
0.0001, p = 0.001, p <
0.0001 respectively).
The October 2013 Spine Roundup360 looks at: Standing straighter may reduce falls; Operative management of congenital kyphosis; Athletic discectomy; Lumbar spine stenosis worsens with time; Flexible stabilisation?: spinal stenosis revisited; Do epidural steroids cause spinal fractures?; Who does well with cervical myelopathy?; Secretly adverse to BMP-2?
The October 2013 Wrist &
Hand Roundup360 looks at: Cost effectiveness of Dupuytren’s surgery; A 'new horizon' in distal radius imaging; Undisplaced means undisplaced; The mystery of the distal radial fracture continues; How thick is thick enough?: articular cartilage step off revisited; Is the midcarpal joint more important than we think?; Plates and Kirschner wires; Better early results with an IM nail?
Osteoarthritis results in changes in the dimensions
of the glenoid. This study aimed to assess the size and radius of curvature
of arthritic glenoids. A total of 145 CT scans were analysed, performed
as part of routine pre-operative assessment before total shoulder
replacement in 91 women and 54 men. Only patients with primary osteoarthritis and
a concentric glenoid were included in the study. The CT scans underwent
three-dimensional (3D) reconstruction and were analysed using dedicated
computer software. The measurements consisted of maximum superoinferior height,
anteroposterior width and a best-fit sphere radius of curvature
of the glenoid. The mean height was 40.2 mm ( With current shoulder replacement systems using a unique backside
radius of curvature for the glenoid component, there is a risk of
undertaking excessive reaming to adapt the bone to the component
resulting in sacrifice of subchondral bone or under-reaming and
instability of the component due to a ’rocking horse‘ phenomenon. Cite this article:
We performed a retrospective review of a consecutive
series of 178 Mobility total ankle replacements (TARs) performed
by three surgeons between January 2004 and June 2009, and analysed
radiological parameters and clinical outcomes in a subgroup of 129
patients. The mean follow-up was 4 years (2 to 6.3). A total of
ten revision procedures (5.6%) were undertaken. The mean Ankle Osteoarthritis
Scale (AOS) pain score was 17 (0 to 88) and 86% of patients were
clinically improved at follow-up. However, 18 patients (18 TARs,
14%) had a poor outcome with an AOS pain score of >
30. A worse
outcome was associated with a pre-operative diagnosis of post-traumatic degenerative
arthritis. However, no pre- or post-operative radiological parameters
were significantly associated with a poor outcome. Of the patients
with persistent pain, eight had predominantly medial-sided pain.
Thirty TARs (29%) had a radiolucency in at least one zone. The outcome of the Mobility TAR at a mean of four years is satisfactory
in >
85% of patients. However, there is a significant incidence
of persistent pain, particularly on the medial side, for which we
were unable to establish a cause. Cite this article:
Although gradual bone transport may permit the
restoration of large-diameter bones, complications are common owing
to the long duration of external fixation. In order to reduce such
complications, a new technique of bone transport involving the use
of an external fixator and a locking plate was devised for segmental
tibial bone defects. A total of ten patients (nine men, one woman) with a mean age
at operation of 40.4 years (16 to 64) underwent distraction osteogenesis
with a locking plate to treat previously infected post-traumatic
segmental tibial defects. The locking plate was fixed percutaneously
to bridge proximal and distal segments, and was followed by external fixation.
After docking, percutaneous screws were fixed at the transported
segment through plate holes. At the same time, bone grafting was
performed at the docking site with the external fixator removed. The mean defect size was 5.9 cm (3.8 to 9.3) and mean external
fixation index was
13.4 days/cm (11.8 to 19.5). In all cases, primary union of the
docking site and distraction callus was achieved, with an excellent
bony result. There was no recurrence of deep infection or osteomyelitis,
and with the exception of one patient with a pre-existing peroneal
nerve injury, all achieved an excellent or good functional result. With short external fixation times and low complication rates,
bone transport with a locking plate could be recommended for patients
with segmental tibial defects. Cite this article:
In a study on ten fresh human cadavers we examined the change in the height of the intervertebral disc space, the angle of lordosis and the geometry of the facet joints after insertion of intervertebral total disc replacements. SB III Charité prostheses were inserted at L3-4, L4-5, and L5-S1. The changes studied were measured using computer navigation sofware applied to CT scans before and after instrumentation. After disc replacement the mean lumbar disc height was doubled (p <
0.001). The mean angle of lordosis and the facet joint space increased by a statistically significant extent (p <
0.005 and p = 0.006, respectively). By contrast, the mean facet joint overlap was significantly reduced (p <
0.001). Our study indicates that the increase in the intervertebral disc height after disc replacement changes the geometry at the facet joints. This may have clinical relevance.
The August 2013 Foot &
Ankle Roundup360 looks at: mobility, ankles and fractures; hindfoot nailing: not such a bad option after all?; little treatment benefit for blood injection in tendonitis; fixed bearing ankles successful in the short term; hindfoot motion following STAR ankle replacement; minimally invasive calcaneal fracture fixation?; pes planus in adolescents; and subluxing peroneals and groove deepening
Orientation of the acetabular component influences
wear, range of movement and the incidence of dislocation after total
hip replacement (THR). During surgery, such orientation is often
referenced to the anterior pelvic plane (APP), but APP inclination
relative to the coronal plane (pelvic tilt) varies substantially
between individuals. In contrast, the change in pelvic tilt from
supine to standing (dPT) is small for nearly all individuals. Therefore,
in THR performed with the patient supine and the patient’s coronal
plane parallel to the operating table, we propose that freehand placement
of the acetabular component placement is reliable and reflects standing
(functional) cup position. We examined this hypothesis in 56 hips
in 56 patients (19 men) with a mean age of 61 years (29 to 80) using
three-dimensional CT pelvic reconstructions and standing lateral
pelvic radiographs. We found a low variability of acetabular component
placement, with 46 implants (82%) placed within a combined range
of 30° to 50° inclination and 5° to 25° anteversion. Changing from
the supine to the standing position (analysed in 47 patients) was associated
with an anteversion change <
10° in 45 patients (96%). dPT was
<
10° in 41 patients (87%). In conclusion, supine THR appears
to provide reliable freehand acetabular component placement. In
most patients a small reclination of the pelvis going from supine
to standing causes a small increase in anteversion of the acetabular component Cite this article:
This study used CT analysis to determine the rotational alignment of 39 painful and 26 painless fixed-bearing total knee replacements (TKRs) from a cohort of 740 NexGen Legacy posterior-stabilised and cruciate-retaining prostheses implanted between May 1996 and August 2003. The mean rotation of the tibial component was 4.3° of internal rotation (25.4° internal to 13.9° external rotation) in the painful group and 2.2° of external rotation (8.5° internal to 18.2° external rotation) in the painfree group (p = 0.024). In the painful group 17 tibial components were internally rotated more than 9° compared with none in the painfree group (p <
0.001). Additionally, six femoral components in the painful group were internally rotated more than 6° compared with none in the painfree group (p = 0.017). External rotational errors were not found to be associated with pain. Overall, 22 (56.4%) of the painful TKRs had internal rotational errors involving the femoral, the tibial or both components. It is estimated that at least 4.6% of all our TKRs have been implanted with significant internal rotational errors.
The treatment of fractures of the proximal tibia is complex and makes great demands on the implants used. Our study aimed to identify what levels of primary stability could be achieved with various forms of osteosynthesis in the treatment of diaphyseal fractures of the proximal tibia. Pairs of human tibiae were investigated. An unstable fracture was simulated by creating a defect at the metaphyseal-diaphyseal junction. Six implants were tested in a uniaxial testing device (Instron) using the quasi-static and displacement-controlled modes and the force-displacement curve was recorded. The movements of each fragment and of the implant were recorded video-optically (MacReflex, Qualysis). Axial deviations were evaluated at 300 N. The results show that the nailing systems tolerated the highest forces. The lowest axial deviations in varus and valgus were also found for the nailing systems; the highest axial deviations were recorded for the buttress plate and the less invasive stabilising system (LISS). In terms of rotational displacement the LISS was better than the buttress plate. In summary, it was found that higher loads were better tolerated by centrally placed load carriers than by eccentrically placed ones. In the case of the latter, it appears advantageous to use additive procedures for medial buttressing in the early phase.
The requirement for release of collateral ligaments to achieve a stable, balanced total knee replacement has been reported to arise in about 50% to 100% of procedures. This wide range reflects a lack of standardised quantitative indicators to determine the necessity for a release. Using recent advances in computerised navigation, we describe two navigational predictors which provide quantitative measures that can be used to identify the need for release. The first was the ability to restore the mechanical axis before any bone resection was performed and the second was the discrepancy in the measured medial and lateral joint spaces after the tibial osteotomy, but before any femoral resection. These predictors showed a significant association with the need for collateral ligament release (p <
0.001). The first predictor using the knee stress test in extension showed a sensitivity of 100% and a specificity of 98% and the second, the difference between medial and lateral gaps in millimetres, a sensitivity of 83% and a specificity of 95%. The use of the two navigational predictors meant that only ten of the 93 patients required collateral ligament release to achieve a stable, neutral knee.
The June 2013 Knee Roundup360 looks at: knee arthroplasty in diabetic patients; whether TKR is a timebomb; the use of antidepressants for knee OA; trochleoplasty; articulated spacers; mental health and joint replacement; and the use of physiotherapy for meniscal tear.
The objective of this study was to evaluate the rotation and
translation of each joint in the hindfoot and compare the load response
in healthy feet with that in stage II posterior tibial tendon dysfunction
(PTTD) flatfoot by analysing the reconstructive three-dimensional
(3D) computed tomography (CT) image data during simulated weight-bearing. CT scans of 15 healthy feet and 15 feet with stage II PTTD flatfoot
were taken first in a non-weight-bearing condition, followed by
a simulated full-body weight-bearing condition. The images of the
hindfoot bones were reconstructed into 3D models. The ‘twice registration’
method in three planes was used to calculate the position of the
talus relative to the calcaneus in the talocalcaneal joint, the
navicular relative to the talus in talonavicular joint, and the cuboid
relative to the calcaneus in the calcaneocuboid joint.Objective
Methods