The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 210 - 216
1 Feb 2011
Young A Walch G Boileau P Favard L Gohlke F Loew M Molé D

We report the long-term clinical and radiological outcomes of the Aequalis total shoulder replacement with a cemented all-polyethylene flat-back keeled glenoid component implanted for primary osteoarthritis between 1991 and 2003 in nine European centres. A total of 226 shoulders in 210 patients were retrospectively reviewed at a mean of 122.7 months (61 to 219) or at revision. Clinical outcome was assessed using the Constant score, patient satisfaction score and range of movement. Kaplan-Meier survivorship analysis was performed with glenoid revision for loosening and radiological glenoid loosening (sd) as endpoints. The Constant score was found to improve from a mean of 26.8 (sd 10.3) pre-operatively to 57.6 (sd 20.0) post-operatively (p < 0.001). Active forward flexion improved from a mean of 85.3° (sd 27.4) pre-operatively to 125° (sd 37.3) postoperatively (p < 0.001). External rotation improved from a mean of 7° (sd 6.5) pre-operatively to 30.3° (sd 21.8°) post-operatively (p < 0.001). Survivorship with revision of the glenoid component as the endpoint was 99.1% at five years, 94.5% at ten years and 79.4% at 15 years. Survivorship with radiological loosening as the endpoint was 99.1% at five years, 80.3% at ten years and 33.6% at 15 years.

Younger patient age and the curettage technique for glenoid preparation correlated with loosening. The rate of glenoid revision and radiological loosening increased with duration of follow-up, but not until a follow-up of five years. Therefore, we recommend that future studies reporting radiological outcomes of new glenoid designs should report follow-up of at least five to ten years.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 941 - 948
1 Jul 2010
Stone KR Adelson WS Pelsis JR Walgenbach AW Turek TJ

We describe 119 meniscal allograft transplantations performed concurrently with articular cartilage repair in 115 patients with severe articular cartilage damage. In all, 53 (46.1%) of the patients were over the age of 50 at the time of surgery. The mean follow-up was for 5.8 years (2 months to 12.3 years), with 25 procedures (20.1%) failing at a mean of 4.6 years (2 months to 10.4 years). Of these, 18 progressed to knee replacement at a mean of 5.1 years (1.3 to 10.4). The Kaplan-Meier estimated mean survival time for the whole series was 9.9 years (sd 0.4). Cox’s proportional hazards model was used to assess the effect of covariates on survival, with age at the time of surgery (p = 0.026) and number of previous operations (p = 0.006) found to be significant.

The survival of the transplant was not affected by gender, the severity of cartilage damage, axial alignment, the degree of narrowing of the joint space or medial versus lateral allograft transplantation. Patients experienced significant improvements at all periods of follow-up in subjective outcome measures of pain, activity and function (all p-values < 0.05), with the exception of the seven-year Tegner index score (p = 0.076).


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 11 | Pages 1568 - 1573
1 Nov 2010
Krieg AH Lenze U Gaston MS Hefti F

We retrospectively evaluated 18 patients with a mean age of 37.3 years (14 to 72) who had undergone pelvic reconstruction stabilised with a non-vascularised fibular graft after resection of a primary bone tumour. The mean follow-up was 10.14 years (2.4 to 15.7). The mean Musculoskeletal Tumor Society Score was 76.5% (50% to 100%). Primary union was achieved in the majority of reconstructions within a mean of 22.9 weeks (7 to 60.6). The three patients with delayed or nonunion all received additional therapy (chemotherapy/radiation) (p = 0.0162). The complication rate was comparable to that of other techniques described in the literature.

Non-vascularised fibular transfer to the pelvis is a simpler, cheaper and quicker procedure than other currently described techniques. It is a biological reconstruction with good results and a relatively low donor site complication rate. However, adjuvant therapy can negatively affect the outcome of such grafts.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 11 | Pages 1501 - 1508
1 Nov 2010
Donell ST Darrah C Nolan JF Wimhurst J Toms A Barker THW Case CP Tucker JK

Metal-on-metal total hip replacement has been targeted at younger patients with anticipated long-term survival, but the effect of the production of metal ions is a concern because of their possible toxicity to cells. We have reviewed the results of the use of the Ultima hybrid metal-on-metal total hip replacement, with a cemented polished tapered femoral component with a 28 mm diameter and a cobalt-chrome (CoCr) modular head, articulating with a 28 mm CoCr acetabular bearing surface secured in a titanium alloy uncemented shell.

Between 1997 and 2004, 545 patients with 652 affected hips underwent replacement using this system. Up to 31 January 2008, 90 (13.8%) hips in 82 patients had been revised. Pain was the sole reason for revision in 44 hips (48.9%) of which 35 had normal plain radiographs. Peri-prosthetic fractures occurred in 17 hips (18.9%) with early dislocation in three (3.3%) and late dislocation in 16 (17.8%). Infection was found in nine hips (10.0%).

At operation, a range of changes was noted including cavities containing cloudy fluid under pressure, necrotic soft tissues with avulsed tendons and denuded osteonecrotic upper femora. Corrosion was frequently observed on the retrieved cemented part of the femoral component. Typically, the peri-operative findings confirmed those found on pre-operative metal artefact reduction sequence MRI and histological examination showed severe necrosis.

Metal artefact reduction sequence MRI proved to be useful when investigating these patients with pain in the absence of adverse plain radiological features.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1325 - 1331
1 Oct 2010
Patel S Rodriguez-Merchan EC Haddad FS

Fibrin glue, also known as fibrin sealant, is now established as a haemostatic agent in surgery, but its role in orthopaedic surgery is neither well known nor clearly defined. Although it was originally used over 100 years ago, concerns about transmission of disease meant that it fell from favour. It is also available as a slow-release drug delivery system and as a substrate for cellular growth and tissue engineering. Consequently, it has the potential to be used in a number of ways in orthopaedic surgery. The purpose of this review is to address its use in surgery of the knee in which it appears to offer great promise.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 651 - 655
1 May 2010
Meuffels DE Schuit H van Biezen FC Reijman M Verhaar JAN

We present the long-term outcome, at a median of 18 years (12.8 to 23.5) of open posterior bone block stabilisation for recurrent posterior instability of the shoulder in a heterogenous group of 11 patients previously reported on in 2001 at a median follow-up of six years.

We found that five (45%) would not have chosen the operation again, and that four (36%) had further posterior dislocation. Clinical outcome was significantly worse after 18 years than after six years of follow-up (median Rowe score of 60 versus 90 (p = 0.027)). The median Western Ontario Shoulder Index was 60% (37% to 100%) at 18 years’ follow-up, which is a moderate score. At the time of surgery four (36%) had glenohumeral radiological osteoarthritis, which was present in all after 18 years.

This study showed poor long-term results of the posterior bone block procedure for posterior instability and a high rate of glenohumeral osteoarthritis although three patients with post-traumatic instability were pleased with the result of their operations.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 661 - 667
1 May 2010
van Riet RP Sanchez-Sotelo J Morrey BF

There is little information available at present regarding the mechanisms of failure of modern metallic radial head implants. Between 1998 and 2008, 44 consecutive patients (47 elbows) underwent removal of a failed metallic radial head replacement. In 13 patients (13 elbows) the initial operation had been undertaken within one week of a fracture of the radial head, at one to six weeks in seven patients (seven elbows) and more than six weeks (mean of 2.5 years (2 to 65 months)) in 22 patients (25 elbows). In the remaining two elbows the replacement was inserted for non-traumatic reasons. The most common indication for further surgery was painful loosening (31 elbows). Revision was undertaken for stiffness in 18 elbows, instability in nine, and deep infection in two. There were signs of over-lengthening of the radius in 11 elbows. Degenerative changes were found in all but one. Only three loose implants had been fixed with cement. Instability was not identified in any of the bipolar implants.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1310 - 1315
1 Oct 2009
Ibrahim SAR Hamido F Al Misfer AK Mahgoob A Ghafar SA Alhran H

A total of 218 patients with unilateral anterior cruciate ligament deficiency were randomly assigned to one of four groups. In group A an anatomical double bundle anterior cruciate ligament reconstruction was performed; group B were treated by a single bundle using an Endobutton for femoral fixation; in group C by a single bundle using RigidFix cross pins for femoral fixation; and in group D by a single bundle using a bioabsorbable TransFix II screw for femoral fixation. For tibial fixation a bioabsorbable Intrafix interference screw was used for all the groups and the graft was fashioned from the semitendinosus and gracilis tendons in all patients. In all, 18 patients were lost to follow-up. The remaining 200 were subjected to a clinical evaluation, with assessment of the anterior drawer, Lachman’s and the pivot-shift tests, and KT-1000 arthrometer measurement. They also completed the International Knee Documentation Committee, Lysholm knee and Tegner activity scores.

At a mean of 29 months (25 to 38) follow-up there were no significant differences concerning time between injury and range of movement and Lysholm knee scores among the four groups. However, the double bundle method showed significantly better results for the pivot-shift test (p = 0.002). The KT 1000 measurements showed a mean difference between the reconstructed knee and the patients’ normal knee of 1.4 mm in the double bundle group and 2.4 mm in the single bundle group; which was statistically significant. The Lachman and anterior drawer tests also showed superior results for the double bundle method. The International Knee Documentation Committee scale showed no significant difference among the groups (p < 0.001).

On clinical evaluation the double bundle group showed less laxity than the single bundle groups. However, regardless of the technique, all knees were improved by anterior cruciate ligament reconstruction compared with their pre-operative status.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 6 | Pages 835 - 842
1 Jun 2009
Hart AJ Skinner JA Winship P Faria N Kulinskaya E Webster D Muirhead-Allwood S Aldam CH Anwar H Powell JJ

We carried out a cross-sectional study with analysis of the demographic, clinical and laboratory characteristics of patients with metal-on-metal hip resurfacing, ceramic-on-ceramic and metal-on-polyethylene hip replacements. Our aim was to evaluate the relationship between metal-on-metal replacements, the levels of cobalt and chromium ions in whole blood and the absolute numbers of circulating lymphocytes. We recruited 164 patients (101 men and 63 women) with hip replacements, 106 with metal-on-metal hips and 58 with non-metal-on-metal hips, aged < 65 years, with a pre-operative diagnosis of osteoarthritis and no pre-existing immunological disorders.

Laboratory-defined T-cell lymphopenia was present in13 patients (15%) (CD8+ lymphopenia) and 11 patients (13%) (CD3+ lymphopenia) with unilateral metal-on-metal hips. There were significant differences in the absolute CD8+ lymphocyte subset counts for the metal-on-metal groups compared with each control group (p-values ranging between 0.024 and 0.046). Statistical modelling with analysis of covariance using age, gender, type of hip replacement, smoking and circulating metal ion levels, showed that circulating levels of metal ions, especially cobalt, explained the variation in absolute lymphocyte counts for almost all lymphocyte subsets.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1373 - 1377
1 Oct 2009
Spiegelberg BGI Sewell MD Aston WJS Blunn GW Pollock R Cannon SR Briggs TWR

This paper describes the preliminary results of a proximal tibial endoprosthesis which spares the knee joint and enables retention of the natural articulation by replacing part of the tibial metaphysis and diaphysis. In eight patients who had a primary malignant bone tumour of the proximal tibia, the distal stem, which had a hydroxyapatite-coated collar to improve fixation, was cemented into the medullary canal. The proximal end had hydroxyapatite-coated extracortical plates which were secured to the remaining proximal tibial metaphysis using cortical screws. The mean age of the patients at operation was 28.9 years (8 to 43) and the mean follow-up was for 35 months (4 to 48). The mean Musculoskeletal Tumour Society score was 79% (57% to 90%), the mean Oxford Knee score was 40 points of 48 (36 to 46) and the mean knee flexion was 112° (100° to 120°). In one patient, revision to a below-knee amputation through the prosthesis was required because of recurrence of the tumour. Another patient sustained a periprosthetic fracture which healed with a painful malunion. This was revised to a further endoprosthesis which replaced the knee.

In the remaining six patients the prosthesis allowed preservation of the knee joint with good function and no early evidence of loosening. Further follow-up is required to assess the longevity of these prostheses.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1296 - 1300
1 Oct 2009
Jackson MP Sexton SA Yeung E Walter WL Walter WK Zicat BA

The outcome of total hip replacement (THR) is potentially affected by the body mass index (BMI) of the patient. We studied the outcome of 2026 consecutive primary cementless THRs performed for osteoarthritis. The mean follow-up was 6.3 years (0 to 11.71) and no patient was lost to follow-up for survival analysis. The patients were divided into two groups according to their BMI as follows: non-obese (BMI < 30 kg/m2) and obese (BMI ≥ 30 kg/m2).

The obese patient undergoing surgery was found to be significantly younger (p < 0.001). The log-rank test for equality of survival showed no difference in the mid-term survival (p = 0.552) with an estimated survival at 11 years of 95.2% (95% CI 92.5 to 98.0) in the non-obese and 96.7% (95% CI 94.9 to 98.5) in the obese groups. The clinical and radiological outcome was determined in a case-matched study performed on 134 obese individuals closely matched with 134 non-obese controls. The non-obese group was found to have a significantly higher post-operative Harris hip score (p < 0.001) and an increased range of movement, but overall satisfaction with surgery was comparable with that of the obese patients. Radiological analysis of the acetabular and femoral components showed no significant differences with regard to radiolucent lines, osteolysis, ingrowth of the femoral component, the acetabular inclination angle or alignment of the femoral component. Our results suggest that the survival of cementless THR is not adversely affected by obesity. Obese patients can therefore be counselled that despite a lower clinical score, they should expect to be satisfied with the result of their THR with a mid-term survival rate equivalent to that of non-obese patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1316 - 1321
1 Oct 2009
Wallander H Larsson S Bjönness T Hansson G

The outcome in 83 patients with congenital clubfoot was evaluated at a mean age of 64 years using three validated questionnaires assessing both quality of life (short-form (SF)-36 and EQ-5D) and foot and ankle function (American Academy of Orthopaedic Surgeons (AAOS) Foot and Ankle questionnaire). In SF-36, male patients scored significantly better than male norms in seven of the eight domains, whereas female patients scored significantly worse than female norms in two of the eight. Male patients scored better than male norms in both the EQ-5D index (p = 0.027) and visual analogue scale (VAS) (p = 0.013), whereas female patients scored worse than female norms in the VAS (p < 0.001). Both male and female patients had a significantly worse outcome on the AAOS Core Scale than did norms. There was a significant correlation for both genders between the SF-36 Physical Component Summary Score and the AAOS Core Scale.

The influence on activities of daily life was limited to foot and ankle problems in all patients, and in females there was an adverse effect in physical aspects of quality of life.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 7 | Pages 915 - 917
1 Jul 2009
Gwilym SE Watkins B Cooper CD Harvie P Auplish S Pollard TCB Rees JL Carr AJ

The aim of this study was to investigate genetic influences on the development and progression of tears of the rotator cuff. From a group of siblings of patients with a tear of the rotator cuff and of controls studied five years earlier, we determined the prevalence of tears of the rotator cuff with and without associated symptoms using ultrasound and the Oxford Shoulder Score.

In the five years since the previous assessment, three of 62 (4.8%) of the sibling group and one of the 68 (1.5%) controls had undergone shoulder surgery. These subjects were excluded from the follow-up.

Full-thickness tears were found in 39 of 62 (62.9%) siblings and in 15 of 68 (22.1%) controls (p = 0.0001). The relative risk of full-thickness tears in siblings as opposed to controls was 2.85 (95% confidence interval (CI) 1.75 to 4.64), compared to 2.42 (95% CI 1.77 to 3.31) five years earlier. Full-thickness tears associated with pain were found in 30 of 39 (76.9%) tears in the siblings and in eight of 15 (53.3%) tears in the controls (p = 0.045). The relative risk of pain associated with a full-thickness tear in the siblings as opposed to the controls was 1.44 (95% CI 2.04 to 8.28) (p = 0.045).

In the siblings group ten of 62 (16.1%) had progressed in terms of tear size or development compared to one of 68 (1.5%) in the control group which had increased in size.

Full-thickness rotator cuff tears in siblings are significantly more likely to progress over a period of five years than in a control population. This implies that genetic factors have a role, not only in the development but also in the progression of full-thickness tears of the rotator cuff.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 7 | Pages 855 - 858
1 Jul 2009
Wroblewski BM Siney PD Fleming PA

The design of the Charnley total hip replacement follows the principle of low frictional torque. It is based on the largest possible difference between the radius of the femoral head and that of the outer aspect of the acetabular component. The aim is to protect the bone-cement interface by movement taking place at the smaller radius, the articulation. This is achieved in clinical practice by a 22.225 mm diameter head articulating with a 40 mm or 43 mm diameter acetabular component of ultra-high molecular weight polyethylene.

We compared the incidence of aseptic loosening of acetabular components with an outer diameter of 40 mm and 43 mm at comparable depths of penetration with a mean follow-up of 17 years (1 to 40).

In cases with no measurable wear none of the acetabular components were loose. With increasing acetabular penetration there was an increased incidence of aseptic loosening which reflected the difference in the external radii, with 1.5% at 1 mm, 8.8% at 2 mm, 9.7% at 3 mm and 9.6% at 4 mm of penetration in favour of the larger 43 mm acetabular component.

Our findings support the Charnley principle of low frictional torque. The level of the benefit is in keeping with the predicted values.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 9 | Pages 1183 - 1190
1 Sep 2009
Kim BS Choi WJ Kim YS Lee JW

Our study describes the clinical outcome of total ankle replacement (TAR) performed in patients with moderate to severe varus deformity. Between September 2004 and September 2007, 23 ankles with a varus deformity ≥ 10° and 22 with neutral alignment received a TAR. Following specific algorithms according to joint congruency, the varus ankles were managed by various additional procedures simultaneously with TAR.

After a mean follow-up of 27 months (12 to 47), the varus ankles improved significantly in all clinical measures (p < 0.0001 for visual analogue scale and American Orthopaedic Foot and Ankle Society score, p = 0.001 for range of movement). No significant differences were found between the varus and neutral groups regarding the clinical (p = 0.766 for visual analogue scale, p = 0.502 for American Orthopaedic Foot and Ankle Society score, p = 0.773 for range of movement) and radiological outcome (p = 0.339 for heterotopic ossification, p = 0.544 for medial cortical reaction, p = 0.128 for posterior focal osteolysis). Failure of the TAR with conversion to an arthrodesis occurred in one case in each group.

The clinical outcome of TAR performed in ankles with pre-operative varus alignment ≥ 10° is comparable with that of neutrally aligned ankles when appropriate additional procedures to correct the deformity are carried out simultaneously with TAR.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 6 | Pages 720 - 724
1 Jun 2009
Ollivere B Darrah C Brankin RC Donnell ST Walton NP

We report the follow-up at 12 years of the use of the Elite Plus total hip replacement (THR). We have previously reported the results at a mean of 6.4 years. Of the 217 patients (234 THRs), 83 had died and nine had been lost to follow-up. The patients were reviewed radiologically and clinically using the Oxford hip score.

Of the 234 THRs, 19 (8.1%) had required a revision by the final follow-up in all but one for aseptic loosening. Survivorship analysis for revision showed a survival of 93.9% (95% confidence interval (CI) 89.2 to 96.5) at ten years, and of 88.0% (95% CI 81.8 to 92.3) at 12 years. At the final follow-up survival analysis showed that 37% (95% CI 37.3 to 44.7) of the prostheses had either failed radiologically or had been revised. Patients with a radiologically loose femoral component had a significantly poorer Oxford hip score than those with a well-fixed component (p = 0.03). Radiological loosening at 6.4 years was predictive of failure at 12 years.

Medium-term radiographs and clinical scores should be included in the surveillance of THR to give an early indication of the performance of specific implants.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 499 - 503
1 Apr 2009
Kircher J Patzer T Magosch P Lichtenberg S Habermeyer P

We describe the outcome at a mean follow-up of 8.75 years (7.6 to 9.8) of seven patients who had undergone osteochondral autologous transplantation for full-thickness cartilage defects of the shoulder between 1998 and 2000. These patients have been described previously at a mean of 32.6 months when eight were included. One patient has been lost to follow-up. The outcome was assessed by the Constant shoulder score and the Lysholm knee score to assess any donor-site morbidity. Standard radiographs and MR scores were obtained and compared with the pre-operative findings and the results from the previous review.

No patient required any further surgery on the shoulder. The mean Constant score improved significantly until the final follow-up (p = 0.018). The Lysholm score remained excellent throughout. There was a significant progression of osteoarthritic changes from the initial surgery to the first and final follow-up but this did not appear to be related to the size of the defect, the number of cylinders required or the Constant score (p = 0.016). MRI showed that all except one patient had a congruent joint surface at the defect with full bony integration of all osteochondral cylinders.

The results have remained satisfactory over a longer period with very good objective and subjective findings.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 6 | Pages 713 - 719
1 Jun 2009
Denaro V Papalia R Denaro L Di Martino A Maffulli N

Cervical spinal disc replacement is used in the management of degenerative cervical disc disease in an attempt to preserve cervical spinal movement and to prevent adjacent disc overload and subsequent degeneration. A large number of patients have undergone cervical spinal disc replacement, but the effectiveness of these implants is still uncertain. In most instances, degenerative change at adjacent levels represents the physiological progression of the natural history of the arthritic disc, and is unrelated to the surgeon. Complications of cervical disc replacement include loss of movement from periprosthetic ankylosis and ossification, neurological deficit, loosening and failure of the device, and worsening of any cervical kyphosis. Strict selection criteria and adherence to scientific evidence are necessary. Only prospective, randomised clinical trials with long-term follow-up will establish any real advantage of cervical spinal disc replacement over fusion.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 676 - 682
1 May 2009
Østbyhaug PO Klaksvik J Romundstad P Aamodt A

Hydroxyapatite-coated standard anatomical and customised femoral stems are designed to transmit load to the metaphyseal part of the proximal femur in order to avoid stress shielding and to reduce resorption of bone. In a randomised in vitro study, we compared the changes in the pattern of cortical strain after the insertion of hydroxyapatite-coated standard anatomical and customised stems in 12 pairs of human cadaver femora. A hip simulator reproduced the physiological loads on the proximal femur in single-leg stance and stair-climbing. The cortical strains were measured before and after the insertion of the stems.

Significantly higher strain shielding was seen in Gruen zones 7, 6, 5, 3 and 2 after the insertion of the anatomical stem compared with the customised stem. For the anatomical stem, the hoop strains on the femur also indicated that the load was transferred to the cortical bone at the lower metaphyseal or upper diaphyseal part of the proximal femur.

The customised stem induced a strain pattern more similar to that of the intact femur than the standard, anatomical stem.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 357 - 360
1 Mar 2009
Dalury DF Mason JB Murphy JA Adams MJ

Gender-specific total knee replacement has generated much interest recently. We reviewed 1970 Sigma knees implanted in 920 women and 592 men with a mean age of 69.7 years.

At a mean follow-up of 7.3 years (minimum, five years), we found minimal differences in the outcome between genders. At the final follow-up, men had a higher overall Knee Society score and more osteolysis (3.8% vs 1.1%). However, there were no significant differences between men and women in terms of complications or improvements in knee function, pain score or range of movement. The estimated ten-year survivorship was 97% in women and 98% in men (p = 0.96).

We concluded that there was little difference in outcome between the genders treated by a modern unisex design of total knee replacement in this large multicentre study.