It has been shown that the preoperative modification of risk factors associated with obesity may reduce complications after total knee arthroplasty (TKA). However, the optimal method of doing so remains unclear. The aim of this study was to investigate whether a preoperative Risk Stratification Tool (RST) devised in our institution could reduce unexpected intensive care unit (ICU) transfers and 90-day emergency department (ED) visits, readmissions, and reoperations after TKA in obese patients. We retrospectively reviewed 1,614 consecutive patients undergoing primary unilateral TKA. Their mean age was 65.1 years (17.9 to 87.7) and the mean BMI was 34.2 kg/m2 (SD 7.7). All patients underwent perioperative optimization and monitoring using the RST, which is a validated calculation tool that provides a recommendation for postoperative ICU care or increased nursing support. Patients were divided into three groups: non-obese (BMI < 30 kg/m2, n = 512); obese (BMI 30 kg/m2 to 39.9 kg/m2, n = 748); and morbidly obese (BMI > 40 kg/m2, n = 354). Logistic regression analysis was used to evaluate the outcomes among the groups adjusted for age, sex, smoking, and diabetes.Aims
Methods
Removal of infected components and culture-directed antibiotics are important for the successful treatment of chronic periprosthetic joint infection (PJI). However, as many as 27% of chronic PJI patients yield negative culture results. Although culture negativity has been thought of as a contraindication to one-stage revision, data supporting this assertion are limited. The aim of our study was to report on the clinical outcomes for one-stage and two-stage exchange arthroplasty performed in patients with chronic culture-negative PJI. A total of 105 consecutive patients who underwent revision arthroplasty for chronic culture-negative PJI were retrospectively evaluated. One-stage revision arthroplasty was performed in 30 patients, while 75 patients underwent two-stage exchange, with a minimum of one year's follow-up. Reinfection, re-revision for septic and aseptic reasons, amputation, readmission, mortality, and length of stay were compared between the two treatment strategies.Aims
Methods
Limb alignment in total knee arthroplasty (TKA) influences periarticular soft-tissue tension, biomechanics through knee flexion, and implant survival. Despite this, there is no uniform consensus on the optimal alignment technique for TKA. Neutral mechanical alignment facilitates knee flexion and symmetrical component wear but forces the limb into an unnatural position that alters native knee kinematics through the arc of knee flexion. Kinematic alignment aims to restore native limb alignment, but the safe ranges with this technique remain uncertain and the effects of this alignment technique on component survivorship remain unknown. Anatomical alignment aims to restore predisease limb alignment and knee geometry, but existing studies using this technique are based on cadaveric specimens or clinical trials with limited follow-up times. Functional alignment aims to restore the native plane and obliquity of the joint by manipulating implant positioning while limiting soft tissue releases, but the results of high-quality studies with long-term outcomes are still awaited. The drawbacks of existing studies on alignment include the use of surgical techniques with limited accuracy and reproducibility of achieving the planned alignment, poor correlation of intraoperative data to long-term functional outcomes and implant survivorship, and a paucity of studies on the safe ranges of limb alignment. Further studies on alignment in TKA should use surgical adjuncts (e.g. robotic technology) to help execute the planned alignment with improved accuracy, include intraoperative assessments of knee biomechanics and periarticular soft-tissue tension, and correlate alignment to long-term functional outcomes and survivorship.
Fifty-three of 55 consecutive elbow replacements for post-traumatic arthritis were followed for a minimum of two years (mean 6.3, range 2 to 14.4). The patients presented difficult management problems, having undergone an average of two previous operations per joint; 22 joints had suffered prior complications; 18 had less than 50 degrees of flexion and six were flail. One of three versions of the Coonrad prosthesis was employed in all. During the follow-up period, 10 patients underwent 14 revision procedures for aseptic loosening; 38 elbows are currently without progressive radiolucent lines. In two patients an elbow had to be resected, one for
The incidence and prognostic significance of fractures of acrylic cement related to the stem of a femoral head prosthesis in total hip replacement are examined. These fractures are demonsfrated when the cement has been rendered radio-opaque by the addition of barium sulphate. One and a half per cent of the radiographs of 6,649 patients showed these fractures, which were sometimes associated with subsidence of the prosthesis. Fracture of the cement was usually evident at the six-month post-operative review, if it occurred at all. This radiological complication was devoid of symptoms in the majority of cases and tended to occur in patients with excellent functional recovery. In a minority of patients pain in the thigh during the first six months seemed likely to be explained by this fracture. Slight subsidence of the prosthesis in the cement bed appeared to result in a new and final position of stability. The prognosis was very good; only when separation of the fracture exceeded about 4 millimetres was the prognosis doubtful, in which case a chronic
All surgical operations have the potential for contamination, and the equipment used can harbour bacteria. We collected samples from 100 elective primary hip and knee arthroplasties. These showed rates of contamination of 11.4% for the sucker tips, 14.5% for light handles, 9.4% for skin blades and 3.2% for the inside blades used during surgery; 28.7% of gloves used for preparation were also contaminated. Of the samples taken from the collection bags used during hip arthroplasty, 20% grew bacteria, which represents a significant microbial reservoir. Also, 17% of theatre gowns were contaminated at the end of the operation. Contamination was found in 10% of the needles used during closure of the fascia. Overall, 76% of the organisms grown were coagulase-negative staphylococcus. A total of 63% of operations showed contamination in the field of operation. Some changes in practice are suggested. Follow-up for a minimum of two years revealed one
We performed limb lengthening and correction of deformity of nine long bones of the lower limb in six children (mean age, 14.7 years) with osteogenesis imperfecta (OI). All had femoral lengthening and three also had ipsilateral tibial lengthening. Angular deformities were corrected simultaneously. Five limb segments were treated using a monolateral external fixator and four with the Ilizarov frame. In three children, lengthening was done over previously inserted femoral intramedullary rods. The mean lengthening achieved was 6.26 cm (mean healing index, 33.25 days/cm). Significant complications included one
Various surgical techniques have been described for total hip arthroplasty (THA) in patients with Crowe type III dislocated hips, who have a large acetabular bone defect. The aim of this study was to evaluate the long-term clinical results of patients in whom anatomical reconstruction of the acetabulum was performed using a cemented acetabular component and autologous bone graft from the femoral neck. A total of 22 patients with Crowe type III dislocated hips underwent 28 THAs using bone graft from the femoral neck between 1979 and 2000. A Charnley cemented acetabular component was placed at the level of the true acetabulum after preparation with bone grafting. All patients were female with a mean age at the time of surgery of 54 years (35 to 68). A total of 18 patients (21 THAs) were followed for a mean of 27.2 years (20 to 33) after the operation.Aims
Methods
We studied the effects of the timing of tourniquet release in 88 patients randomly allocated for release after wound closure and bandaging (group A), or before the quadriceps layer had been closed allowing control of bleeding before suture (group B). The groups were similar in mean age, weight, gender, preoperative knee score, radiographic grading, and prosthesis implanted. Patients in group B had less postoperative pain, achieved earlier straight-leg raising, and had fewer wound complications. Five patients in group A had to return to theatre, three for manipulation under anaesthesia, one for secondary closure of wound dehiscence, and one for drainage of a haematoma. The last patient later developed a
The outcome at ten years of 100 Freeman hip stems (Finsbury Orthopaedics, Leatherhead, United Kingdom) retaining the neck with a proximal hydroxyapatite coating in a series of 52 men (six bilateral) and 40 women (two bilateral), has been described previously. None required revision for aseptic loosening. We have extended the follow-up to 20 years with a minimum of 17 years. The mean age of the patients at total hip replacement was 58.9 years (19 to 84). Six patients were lost to follow-up, but were included up to their last clinical review. A total of 22 patients (22 hips) had died, all from causes unrelated to their surgery. There have been 43 re-operations for failure of the acetabular component. However, in 38 of these the stem was not revised since it remained stable and there was no associated osteolysis. Two of the revisions were for damage to the trunnion after fracture of a modular ceramic head, and in another two, removal of the femoral component was because of the preference of the surgeon. In all cases the femoral component was well fixed, but could be extracted at the time of acetabular revision. In one case both components were revised for
The aim of this study was to report the results of three forms of reconstruction for patients with a ditsl tibial bone tumour: an intercalary resection and reconstruction, an osteoarticular reconstruction, and arthrodesis of the ankle. A total of 73 patients with a median age of 19 years (interquartile range (IQR) 14 to 36) were included in this retrospective, multicentre study.Aims
Methods
Distraction osteogenesis is widely used for leg lengthening, but often requires a long period of external fixation which carries risks of pin-track sepsis, malalignment, stiffness of the joint and late fracture of the regenerate. We present the results of 20 cases in which, in an attempt to reduce the rate of complications, a combination of external fixation and intramedullary nailing was used. The mean gain in length was 4.7 cm (2 to 8.6). The mean time of external fixation was 20 days per centimetre gain in length. All distracted segments healed spontaneously without refracture or malalignment. There were three cases of
Displaced fractures of the forearm in children are often treated conservatively, but there is a relatively high incidence of redisplacement, malunion and consequent limitation of function. We have performed percutaneous Kirschner (K) wire fixation in 72 such children under the age of 14 years, of which 57 were reviewed for our study. Both the radius and ulna were fractured in 45 (79%), the radius only in eight and the ulna only in four. The mean initial angulation was 19° in the lateral plane and 9° in the anteroposterior plane for the radius and 15° and 9°, respectively, for the ulna. In 42 patients (74%) we performed closed reduction. In the remaining 15 (26%) closed reduction failed and an open reduction, through a minimal approach, was required before K wiring. At a mean follow-up of 20 months all patients had good functional results with an excellent range of movement. Only five had angulation of from 10° to 15° and none had nonunion, premature epiphyseal closure or
We present the results of 525 primary Souter elbow arthroplasties undertaken in 406 patients between 1982 and 1997. There were 372 women and 34 men with a mean age of 57 years; 119 patients had a bilateral procedure. The elbows were affected by chronic inflammatory disease, usually rheumatoid arthritis, which had been present for a mean of 24.7 years (2 to 70). In about 30% the joints were grossly destroyed with significant loss of bone. In 179 elbows the ulnar components were metal-backed and retentive; in the remaining 346, with better bone stock, non-retentive, all-polyethylene prostheses were used. Because of complications, 108 further operations were required in 82 patients. During the early years the incidence of complications was higher. Dislocation was the indication for 30 further procedures in 26 patients. Thirty patients underwent 33 revision procedures for aseptic loosening, 12 had 29 operations because of
The aims of this systematic review were to assess the learning curve of semi-active robotic arm-assisted total hip arthroplasty (rTHA), and to compare the accuracy, patient-reported functional outcomes, complications, and survivorship between rTHA and manual total hip arthroplasty (mTHA). Searches of PubMed, Medline, and Google Scholar were performed in April 2020 in line with the Preferred Reporting Items for Systematic Review and Meta-Analysis statement. Search terms included “robotic”, “hip”, and “arthroplasty”. The criteria for inclusion were published clinical research articles reporting the learning curve for rTHA (robotic arm-assisted only) and those comparing the implantation accuracy, functional outcomes, survivorship, or complications with mTHA.Aims
Methods
We reviewed 50 capitellocondylar elbow replacements performed by the lateral approach in 42 rheumatoid patients, at a median follow-up of three years. There were two major and 17 minor complications; 18 were early and one was late. Eight elbows required reoperation: soft-tissue surgery was performed in seven and prosthesis removal in one because of a
There is an increased risk of dislocation of the hip after the resection of a periacetabular tumour and endoprosthetic reconstruction of the defect in the hemipelvis. The aim of this study was to determine the rate and timing of dislocation and to identify its risk factors. To determine the dislocation rate, we conducted a retrospective single-institution study of 441 patients with a periacetabular tumour who had undergone a standard modular hemipelvic endoprosthetic reconstruction between 2003 and 2019. After excluding ineligible patients, 420 patients were enrolled. Patient-specific, resection-specific, and reconstruction-specific variables were studied using univariate and multivariate analyses.Aims
Methods
We report a series of 640 consecutive cervical hip fractures which were followed prospectively for two years after primary internal fixation with two hook-pins. Secondary arthroplasties were performed as salvage procedures in 75 cases and the early outcome of these was studied retrospectively. The mean time in hospital was 25 days for prosthetic replacement, though 60% of the patients had other medical conditions considered as risk factors. Mortality was 5% after six months and 8% after one year. Dislocation was seen in 11% and additional surgery was required in 4%. There was one case of
The results of primary total knee replacement performed on a group of haemophiliac patients in a single institution by the same surgeon using the same surgical technique and prosthesis are reported. A total of 35 primary replacements in 30 patients were carried out between 1996 and 2005 and were reviewed retrospectively. The mean age of the patients was 31 years (24 to 42) and the mean follow-up was for 7.5 years (1 to 10). There were 25 patients with haemophilia A and five with haemophilia B. The HIV status and CD4 count were recorded, and Knee Society scores determined. Two patients had inhibitors to the deficient coagulation factor. There were no early wound infections and only one late