Advertisement for orthosearch.org.uk
Results 401 - 420 of 560
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 954 - 957
1 Jul 2010
Mann HA Myerson MS

We describe five adolescent patients aged between 13 and 16 years with bipartite ossification of the posteromedial aspect of the talus. All presented without a history of trauma.

All the ankles had a similar radiological appearance. Clinically, some restriction of movement was noted in three ankles and two subtalar joints, In addition, pain was noted over the posteromedial aspect of the ankle in three patients. In each patient the bipartite fragment was excised through a posteromedial approach to the ankle. Complete resolution was achieved at six months in three patients, with the remaining two describing exercise-induced symptoms. In one of these this precluded participation in sport.

Despite numerous anatomical variations within the tarsus, a case series of a bipartite talus has not previously been reported. This anatomical variation should be recognised to avoid misinterpretation as post-traumatic or other pathological processes. In the presence of recalcitrant symptoms excision is an option, but this is not universally successful in abolishing symptoms.


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1040 - 1044
1 Aug 2013
Kazi HA Perera JR Gillott E Carroll FA Briggs TWR

We prospectively assessed the efficacy of a ceramic-on-metal (CoM) hip bearing with uncemented acetabular and femoral components in which cobalt­–chrome acetabular liners and alumina ceramic heads were used.

The cohort comprised 94 total hip replacements (THRs) in 83 patients (38 women and 45 men) with a mean age of 58 years (42 to 70). Minimum follow-up was two years. All patients had pre- and post-operative assessment using the Western Ontario and McMaster Universities osteoarthritis index (WOMAC), Oxford hip score and Short-Form 12 scores. All showed a statistically significant improvement from three months post-operatively onwards (all p < 0.001).

After two years whole blood metal ion levels were measured and chromosomal analysis was performed. The levels of all metal ions were elevated except vanadium. Levels of chromium, cobalt, molybdenum and titanium were significantly higher in patients who underwent bilateral THR compared with those undergoing unilateral THR (p < 0.001). Chromosomal analysis demonstrated both structural and aneuploidy mutations. There were significantly more breaks and losses than in the normal population (p < 0.001). There was no significant difference in chromosomal aberration between those undergoing unilateral and bilateral procedures (all analyses p ≥ 0.62).

The use of a CoM THR is effective clinically in the short-term, with no concerns, but the significance of high metal ion levels and chromosomal aberrations in the long-term remains unclear.

Cite this article: Bone Joint J 2013;95-B:1040–44.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 315 - 320
1 Mar 2011
Hart AJ Ilo K Underwood R Cann P Henckel J Lewis A Cobb J Skinner J

We measured the orientation of the acetabular and femoral components in 45 patients (33 men, 12 women) with a mean age of 53.4 years (30 to 74) who had undergone revision of metal-on-metal hip resurfacings. Three-dimensional CT was used to measure the inclination and version of the acetabular component, femoral version and the horizontal femoral offset, and the linear wear of the removed acetabular components was measured using a roundness machine.

We found that acetabular version and combined version of the acetabular and femoral components were weakly positively correlated with the rate of wear. The acetabular inclination angle was strongly positively correlated with the rate of wear. Femoral version was weakly negatively correlated with the rate of wear. Application of a threshold of > 5 μm/year for the rate of wear in order to separate the revisions into low or high wearing groups showed that more high wearing components were implanted outside Lewinnek’s safe zone, but that this was mainly due to the inclination of the acetabular component, which was the only parameter that significantly differed between the groups.

We were unable to show that excess version of the acetabular component alone or combined with femoral version was associated with an increase in the rate of wear based on our assessment of version using CT.


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1114 - 1120
1 Aug 2013
Wijdicks CA Anavian J Hill BW Armitage BM Vang S Cole PA

The glenopolar angle assesses the rotational alignment of the glenoid and may provide prognostic information and aid the management of scapula fractures. We have analysed the effect of the anteroposterior (AP) shoulder radiograph rotational offset on the glenopolar angle in a laboratory setting and used this to assess the accuracy of shoulder imaging employed in routine clinical practice. Fluoroscopic imaging was performed on 25 non-paired scapulae tagged with 2 mm steel spheres to determine the orientation of true AP views. The glenopolar angle was measured on all the bony specimens rotated at 10° increments. The mean glenopolar angle measured on the bone specimens in rotations between 0° and 20° and thereafter was found to be significantly different (p < 0.001). We also obtained the AP radiographs of the uninjured shoulder of 30 patients treated for fractures at our centre and found that none fitted the criteria of a true AP shoulder radiograph. The mean angular offset from the true AP view was 38° (10° to 65°) for this cohort. Radiological AP shoulder views may not fully project the normal anatomy of the scapular body and the measured glenopolar angle. The absence of a true AP view may compromise the clinical management of a scapular fracture.

Cite this article: Bone Joint J 2013;95-B:1114–20.


The Bone & Joint Journal
Vol. 95-B, Issue 7 | Pages 917 - 922
1 Jul 2013
Sabouret P Lavoie F Cloutier J

We report on the long-term results of 163 bicruciate-retaining Hermes 2C total knee replacements in 130 patients at a mean follow-up of 22.4 years (20.3 to 23.5). Even when the anterior cruciate ligament had a partially degenerative appearance it was preserved as long as the knee had a normal anterior drawer and Lachman’s test pre-operatively. The description and surgical technique of this minimally constrained prosthesis were published in 1983 and the ten-year clinical results in 1999.

A total of 12% of the knees (20 of 163) in this study were revised because of wear of the polyethylene tibial insert. Excellent stability was achieved and the incidence of aseptic component loosening was 4.3% (seven of 163). The survival rate using revision for any reason as the endpoint was 82% (95% confidence interval 76.2 to 88.0).

Although this series included a relatively small number of replacements, it demonstrated that the anterior cruciate ligament, even when partially degenerated at the time of TKR, remained functional and provided adequate stability at a long-term follow-up.

Cite this article: Bone Joint J 2013;95-B:917–22.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1617 - 1625
1 Dec 2013
Schmitz MWJL Timmer C Rijnen WHC Gardeniers JWM Schreurs BW

Despite the worldwide usage of the cemented Contemporary acetabular component (Stryker), no published data are available regarding its use in patients aged < 50 years. We undertook a mid- to long-term follow-up study, including all consecutive patients aged < 50 years who underwent a primary total hip replacement using the Contemporary acetabular component with the Exeter cemented stem between January 1999 and January 2006. There were 152 hips in 126 patients, 61 men and 65 women, mean age at surgery 37.6 years (16 to 49 yrs). One patient was lost to follow-up.

Mean clinical follow-up of all implants was 7.6 years (0.9 to 12.0). All clinical questionnaire scores, including Harris hip score, Oxford hip score and several visual analogue scales, were found to have improved. The eight year survivorship of all acetabular components for the endpoints revision for any reason or revision for aseptic loosening was 94.4% (95% confidence interval (CI) 89.2 to 97.2) and 96.4% (95% CI 91.6 to 98.5), respectively. Radiological follow-up was complete for 146 implants. The eight year survival for the endpoint radiological loosening was 93.1% (95% CI 86.2 to 96.6). Three surviving implants were considered radiologically loose but were asymptomatic. The presence of acetabular osteolysis (n = 17, 11.8%) and radiolucent lines (n = 20, 13.9%) in the 144 surviving cups indicates a need for continued observation in the second decade of follow-up in order to observe their influence on long-term survival.

The clinical and radiological data resulting in a ten-year survival rate > 90% in young patients support the use of the Contemporary acetabular component in this specific patient group.

Cite this article: Bone Joint J 2013;95-B:1617–25.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 402 - 404
1 Mar 2006
Boardman DR Middleton FR Kavanagh TG

As metal-on-metal arthroplasty becomes more widespread, concerns are being raised about the potential dangers of metal particulate debris. We present the case of a benign psoas mass secondary to the presence of such particles. The mass was excised and the hip resurfacing subsequently revised to a total hip replacement.


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1339 - 1347
1 Oct 2013
Scott CEH Eaton MJ Nutton RW Wade FA Pankaj P Evans SL

As many as 25% to 40% of unicompartmental knee replacement (UKR) revisions are performed for pain, a possible cause of which is proximal tibial strain. The aim of this study was to examine the effect of UKR implant design and material on cortical and cancellous proximal tibial strain in a synthetic bone model. Composite Sawbone tibiae were implanted with cemented UKR components of different designs, either all-polyethylene or metal-backed. The tibiae were subsequently loaded in 500 N increments to 2500 N, unloading between increments. Cortical surface strain was measured using a digital image correlation technique. Cancellous damage was measured using acoustic emission, an engineering technique that detects sonic waves (‘hits’) produced when damage occurs in material.

Anteromedial cortical surface strain showed significant differences between implants at 1500 N and 2500 N in the proximal 10 mm only (p < 0.001), with relative strain shielding in metal-backed implants. Acoustic emission showed significant differences in cancellous bone damage between implants at all loads (p = 0.001). All-polyethylene implants displayed 16.6 times the total number of cumulative acoustic emission hits as controls. All-polyethylene implants also displayed more hits than controls at all loads (p < 0.001), more than metal-backed implants at loads ≥ 1500 N (p < 0.001), and greater acoustic emission activity on unloading than controls (p = 0.01), reflecting a lack of implant stiffness. All-polyethylene implants were associated with a significant increase in damage at the microscopic level compared with metal-backed implants, even at low loads. All-polyethylene implants should be used with caution in patients who are likely to impose large loads across their knee joint.

Cite this article: Bone Joint J 2013;95-B:1339–47.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1591 - 1595
1 Dec 2006
Price AJ Oppold PT Murray DW Zavatsky AB

The Oxford medial unicompartmental knee replacement was designed to reproduce normal mobility and forces in the knee, but its detailed effect on the patellofemoral joint has not been studied previously. We have examined the effect on patellofemoral mechanics of the knee by simultaneously measuring patellofemoral kinematics and forces in 11 cadaver knee specimens in a supine leg-extension rig. Comparison was made between the intact normal knee and sequential unicompartmental and total knee replacement. Following medial mobile-bearing unicompartmental replacement in 11 knees, patellofemoral kinematics and forces did not change significantly from those in the intact knee across any measured parameter. In contrast, following posterior cruciate ligament retaining total knee replacement in eight knees, there were significant changes in patellofemoral movement and forces.

The Oxford device appears to produce near-normal patellofemoral mechanics, which may partly explain the low incidence of complications with the extensor mechanism associated with clinical use.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1595 - 1602
1 Dec 2013
Modi CS Beazley J Zywiel MG Lawrence TM Veillette CJH

The aim of this review is to address controversies in the management of dislocations of the acromioclavicular joint. Current evidence suggests that operative rather than non-operative treatment of Rockwood grade III dislocations results in better cosmetic and radiological results, similar functional outcomes and longer time off work. Early surgery results in better functional and radiological outcomes with a reduced risk of infection and loss of reduction compared with delayed surgery.

Surgical options include acromioclavicular fixation, coracoclavicular fixation and coracoclavicular ligament reconstruction. Although non-controlled studies report promising results for arthroscopic coracoclavicular fixation, there are no comparative studies with open techniques to draw conclusions about the best surgical approach. Non-rigid coracoclavicular fixation with tendon graft or synthetic materials, or rigid acromioclavicular fixation with a hook plate, is preferable to fixation with coracoclavicular screws owing to significant risks of loosening and breakage.

The evidence, although limited, also suggests that anatomical ligament reconstruction with autograft or certain synthetic grafts may have better outcomes than non-anatomical transfer of the coracoacromial ligament. It has been suggested that this is due to better restoration horizontal and vertical stability of the joint.

Despite the large number of recently published studies, there remains a lack of high-quality evidence, making it difficult to draw firm conclusions regarding these controversial issues.

Cite this article: Bone Joint J 2013;95-B:1595–1602.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1579 - 1582
1 Dec 2009
Starks I Roberts S White SH

We present a prospective review of the two-year functional outcome of 37 Avon patellofemoral joint replacements carried out in 29 patients with a mean age of 66 years (30 to 82) between October 2002 and March 2007. No patients were lost to follow-up. This is the first independent assessment of this prosthesis using both subjective and objective analysis of outcome. At two years the median Oxford knee score was 39 (interquartile range 32 to 44), the median American Knee Society objective score was 95 (interquartile range 90 to 100), the median American Knee Society functional score was 85 (interquartile range 60 to 100), and the median Melbourne Knee score was 28 (interquartile range 21 to 30). Two patients underwent further surgery. Only one patient reported an unsatisfactory outcome.

We conclude that the promising early results observed by the designing centre are reproducible and provide further support for the role of patellofemoral joint replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1443 - 1447
1 Nov 2009
Zenz P Stiehl JB Knechtel H Titzer-Hochmaier G Schwagerl W

Cementless acetabular fixation has demonstrated superior long-term durability in total hip replacement, but most series have studied implants with porous metal surfaces. We retrospectively evaluated the results of 100 consecutive patients undergoing total hip replacement where a non-porous Allofit component was used for primary press-fit fixation.

This implant is titanium alloy, grit-blasted, with a macrostructure of forged teeth and has a biradial shape. A total of 81 patients (82 hips) were evaluated at final follow-up at a mean of 10.1 years (8.9 to 11.9). The Harris Hip Score improved from a mean 53 points (23 to 73) pre-operatively to a mean of 96 points (78 to 100) at final review. The osseointegration of all acetabular components was radiologically evaluated with no evidence of loosening. The survival rate with revision of the component as the endpoint was 97.5% (95% confidence interval 94 to 100) after 11.9 years. Radiolucency was found in one DeLee-Charnley zone in four acetabular components. None of the implants required revision for aseptic loosening. Two patients were treated for infection, one requiring a two-stage revision of the implant. One femoral stem was revised for osteolysis due to the production of metal wear debris, but the acetabular shell did not require revision.

This study demonstrates that a non-porous titanium acetabular component with adjunct surface fixation offers an alternative to standard porous-coated implants.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 112 - 115
1 Nov 2012
Su EP

Fixed flexion deformities are common in osteoarthritic knees that are indicated for total knee arthroplasty. The lack of full extension at the knee results in a greater force of quadriceps contracture and energy expenditure. It also results in slower walking velocity and abnormal gait mechanics, overloading the contralateral limb. Residual flexion contractures after TKA have been associated with poorer functional scores and outcomes.

Although some flexion contractures may resolve with time after surgery, a substantial percentage will become permanent. Therefore, it is essential to correct fixed flexion deformities at the time of TKA, and be vigilant in the post-operative course to maintain the correction.

Surgical techniques to address pre-operative flexion contractures include: adequate bone resection, ligament releases, removal of posterior osteophytes, and posterior capsular releases. Post-operatively, extension can be maintained with focused physiotherapy, a specially modified continuous passive motion machine, a contralateral heel lift, and splinting.


Bone & Joint 360
Vol. 2, Issue 1 | Pages 6 - 11
1 Feb 2013
Saw K Jee CS

Modern athletes are constantly susceptible to performance-threatening injury as they push their bodies to greater limits and endure higher physical stresses. Loss of performance and training time can adversely and permanently affect a sportsperson’s career. Now more than ever with advancing medical technology the answer may lie in biologic therapy. We have been using peripheral blood stem cells (PBSC) clinically and have been able to demonstrate that stem cells differentiate into target cells to enable regenerative repair. The potential of this technique as a regenerative agent can be seen in three broad applications: 1) articular cartilage, 2) bone and 3) soft tissue. This article highlights the successful cases, among many, in all three of these applications.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 685 - 696
1 Jun 2008
Robinson CM Jenkins PJ Markham PE Beggs I

The sternoclavicular joint is vulnerable to the same disease processes as other synovial joints, the most common of which are instability from injury, osteoarthritis, infection and rheumatoid disease. Patients may also present with other conditions, which are unique to the joint, or are manifestations of a systemic disease process. The surgeon should be aware of these possibilities when assessing a patient with a painful, swollen sternoclavicular joint.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 61 - 64
1 Nov 2012
Mayle Jr RE Paprosky WG

Revision total hip arthroplasty (THA) is projected to increase by 137% from the years 2005 to 2030. Reconstruction of the femur with massive bone loss can be a formidable undertaking. The goals of revision surgery are to create a stable construct, preserve bone and soft tissues, augment deficient host bone, improve function, provide a foundation for future surgery, and create a biomechanically restored hip. Options for treatment of the compromised femur include: resection arthroplasty, allograft prosthetic composite (APC), proximal femoral replacement, cementless fixation with a modular tapered fluted stem, and impaction grafting. The purpose of this article is to review the treatment options along with their associated outcomes in the more severe femoral defects (Paprosky types IIIb and IV) in revision THA.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 449 - 454
1 Apr 2006
Hart AJ Hester T Sinclair K Powell JJ Goodship AE Pele L Fersht NL Skinner J

We have studied the relationship between metal ion levels and lymphocyte counts in patients with metal-on-metal hip resurfacings. Peripheral blood samples were analysed for lymphocyte subtypes and whole blood cobalt and chromium ion levels in 68 patients (34 with metal-on-metal hip resurfacings and 34 with standard metal-on-polyethylene total hip replacements). All hip components were radiologically well-fixed and the patients were asymptomatic. Cobalt and chromium levels were significantly elevated in the patients with metal-on-metal hip resurfacings, compared with the patients with standard metal-on-polyethylene designs (p < 0.0001). There was a statistically significant decrease in the level of CD8+ cells (T-cytotoxic/suppressor) (p = 0.005) in the metal-on-metal hip resurfacing group. A threshold level of blood cobalt and chromium ions was associated with reduced CD8+ T-cell counts. We have no evidence that our patients suffered as a result of this reduced level of CD8+ T-cells.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 877 - 882
1 Jul 2006
Hasegawa M Sudo A Uchida A

A modular layered acetabular component (metal-polyethylene-ceramic) was developed in Japan for use in alumina ceramic-on-ceramic total hip replacement. Between May 1999 and July 2000, we performed 35 alumina ceramic-on-ceramic total hip replacements in 30 consecutive patients, using this layered component and evaluated the clinical and radiological results over a mean follow-up of 5.8 years (5 to 6.5). A total of six hips underwent revision, one for infection, two for dislocation with loosening of the acetabular component, two for alumina liner fractures and one for component dissociation with pelvic osteolysis. There were no fractures of the ceramic heads, and no loosening of the femoral or acetabular component in the unrevised hips was seen at final follow-up. Osteolysis was not observed in any of the unrevised hips. The survivorship analysis at six years after surgery was 83%. The layered acetabular component in our experience, has poor durability because of unexpected mechanical failures including alumina liner fracture and component dissociation.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 472 - 476
1 Apr 2006
Savarino L Greco M Cenni E Cavasinni L Rotini R Baldini N Giunti A

Modern metal-on-metal bearings produce less wear debris and osteolysis, but have the potential adverse effect of release of ions. Improved ceramic-on-ceramic bearings have the lowest wear of all, but the corrosion process has not been analysed.

Our aim was to measure the serum ion release (ng/ml) in 23 patients having stable hip prostheses with a ceramic-on-ceramic coupling (group A) and to compare it with the release in 42 patients with a metal-on-metal bearing (group B) in the medium term. Reference values were obtained from a population of 47 healthy subjects (group C). The concentrations of chromium, cobalt, aluminium and titanium were measured.

There was a significant increase of cobalt, chromium and aluminium levels (p < 0.05) in group B compared with groups A and C. Group A did not differ significantly from the control group. Despite the apparent advantage of a metal-on-metal coupling, especially in younger patients with a long life expectancy, a major concern arises regarding the extent and duration of ion exposure. For this reason, the low corrosion level in a ceramic-on-ceramic coupling could be advantageous.


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 721 - 731
1 Jun 2013
Sewell MD Al-Hadithy N Le Leu A Lambert SM

The sternoclavicular joint (SCJ) is a pivotal articulation in the linked system of the upper limb girdle, providing load-bearing in compression while resisting displacement in tension or distraction at the manubrium sterni. The SCJ and acromioclavicular joint (ACJ) both have a small surface area of contact protected by an intra-articular fibrocartilaginous disc and are supported by strong extrinsic and intrinsic capsular ligaments. The function of load-sharing in the upper limb by bulky periscapular and thoracobrachial muscles is extremely important to the longevity of both joints. Ligamentous and capsular laxity changes with age, exposing both joints to greater strain, which may explain the rising incidence of arthritis in both with age. The incidence of arthritis in the SCJ is less than that in the ACJ, suggesting that the extrinsic ligaments of the SCJ provide greater stability than the coracoclavicular ligaments of the ACJ.

Instability of the SCJ is rare and can be difficult to distinguish from medial clavicular physeal or metaphyseal fracture-separation: cross-sectional imaging is often required. The distinction is important because the treatment options and outcomes of treatment are dissimilar, whereas the treatment and outcomes of ACJ separation and fracture of the lateral clavicle can be similar. Proper recognition and treatment of traumatic instability is vital as these injuries may be life-threatening. Instability of the SCJ does not always require surgical intervention. An accurate diagnosis is required before surgery can be considered, and we recommend the use of the Stanmore instability triangle. Most poor outcomes result from a failure to recognise the underlying pathology.

There is a natural reluctance for orthopaedic surgeons to operate in this area owing to unfamiliarity with, and the close proximity of, the related vascular structures, but the interposed sternohyoid and sternothyroid muscles are rarely injured and provide a clear boundary to the medial retroclavicular space, as well as an anatomical barrier to unsafe intervention.

This review presents current concepts of instability of the SCJ, describes the relevant surgical anatomy, provides a framework for diagnosis and management, including physiotherapy, and discusses the technical challenges of operative intervention.

Cite this article: Bone Joint J 2013;95-B:721–31.