Advertisement for orthosearch.org.uk
Results 401 - 420 of 882
Results per page:
Bone & Joint 360
Vol. 8, Issue 5 | Pages 20 - 21
1 Oct 2019


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 461 - 469
1 Apr 2019
Lädermann A Schwitzguebel AJ Edwards TB Godeneche A Favard L Walch G Sirveaux F Boileau P Gerber C

Aims

The aim of this study was to report the outcomes of different treatment options for glenoid loosening following reverse shoulder arthroplasty (RSA) at a minimum follow-up of two years.

Patients and Methods

We retrospectively studied the records of 79 patients (19 men, 60 women; 84 shoulders) aged 70.4 years (21 to 87) treated for aseptic loosening of the glenosphere following RSA. Clinical evaluation included pre- and post-treatment active anterior elevation (AAE), external rotation, and Constant score.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 8 | Pages 1116 - 1120
1 Nov 2002
Sanchez-Sotelo J Morrey BF

Seven patients with chronic insufficiency of the triceps were treated by either a rotation flap using anconeus (4) or an allograft of tendo Achillis (3). The latter procedure was selected for patients with a large defect in whom the anconeus muscle had been devitalised. Five disruptions were in patients who had previously undergone an elbow replacement. The patients were assessed for subjective satisfaction, pain, range of movement and strength, and the results were graded using the Mayo Elbow Performance Score (MEPS). The mean follow-up was for 33 months (9 to 63). One rotation flap failed six months after operation. At the most recent follow-up, the remaining six patients had no or slight pain, restoration of a functional arc of movement and normal or slightly decreased power of extension. All six were satisfied with the outcome and were able to resume their daily activities with no limitations other than those imposed by the previous elbow replacement. The final MEPS was 100 points in five patients and 75 in one


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 4 | Pages 579 - 582
1 May 2000
Nakata K Shino K Horibe S Natsu-ume T Mae T Ochi T

We have described a method of anatomical reconstruction of the lateral ligaments of the ankles with instability using allogeneic fascia lata dried with solvents and sterilised with gamma irradiation. Twenty ankles of 20 patients were assessed objectively and subjectively after a mean follow-up of 4.2 years (3.1 to 10). The result was excellent in 12 (60%), good in seven (35%) and fair in one (5%); none had a poor result. Stress radiography showed that the angle of talar tilt improved from 12.3 ± 4.2° (mean ±. sd. ) to 5.9 ± 3.0° and that the anterior drawer distance decreased from 9.2 ± 3.9 mm to 4.4 ± 2.5 mm. Neither infection nor limitation of movement occurred after operation. Fascia lata allografts provide a good alternative to autogenous grafts such as the peroneus brevis tendon


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 5 | Pages 689 - 694
1 Jul 2000
Haddad FS Muirhead-Allwood SK Manktelow ARJ Bacarese-Hamilton I

We treated 50 consecutive patients with infected total hip arthroplasties according to a standard protocol. Previous surgery to eradicate the infection had been attempted in 13 patients and discharging sinuses were present in 20. Aspiration arthrography was routinely carried out before our interventions. The first stage was a meticulous removal of all foreign and potentially infected material. Samples were taken for culture and a thorough lavage carried out. Antibiotic-loaded beads were placed in the femoral shaft and an antibiotic-loaded cement ball in the acetabulum. At the second stage an uncemented arthroplasty was introduced. Bone allograft was used in 18 patients. The interval between procedures was usually three weeks, but this was extended if the wound was slow to heal or there was extensive bony destruction. Appropriate antibiotics were given for three months. At a mean follow-up of 5.8 years the rate of reinfection was 8% (4 patients). Two of these patients have had another, successful, two-stage revision. At this medium-term review, a satisfactory clinical and radiological outcome was obtained in all except two patients


The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 116 - 122
1 Jun 2019
Whiteside LA Roy ME

Aims

The aims of this study were to assess the exposure and preservation of the abductor mechanism during primary total hip arthroplasty (THA) using the posterior approach, and to evaluate gluteus maximus transfer to restore abductor function of chronically avulsed gluteus medius and minimus.

Patients and Methods

A total of 519 patients (525 hips) underwent primary THA using the posterior approach, between 2009 and 2013. The patients were reviewed preoperatively and at two and five years postoperatively. Three patients had mild acute laceration of the gluteus medius caused by retraction. A total of 54 patients had mild chronic damage to the tendon (not caused by exposure), which was repaired with sutures through drill holes in the greater trochanter. A total of 41 patients had severe damage with major avulsion of the gluteus medius and minimus muscles, which was repaired with sutures through bone and a gluteus maximus flap transfer to the greater trochanter.


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1626 - 1632
1 Dec 2018
Medellin MR Fujiwara T Tillman RM Jeys LM Gregory J Stevenson JD Parry M Abudu A

Aims

The aim of this paper was to investigate the prognostic factors for local recurrence in patients with pathological fracture through giant cell tumours of bone (GCTB).

Patients and Methods

A total of 107 patients presenting with fractures through GCTB treated at our institution (Royal Orthopaedic Hospital, Birmingham, United Kingdom) between 1995 and 2016 were retrospectively studied. Of these patients, 57 were female (53%) and 50 were male (47%).The mean age at diagnosis was 33 years (14 to 86). A univariate analysis was performed, followed by multivariate analysis to identify risk factors based on the treatment and clinical characteristics.


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 725 - 732
1 Jun 2018
Gibon E Barut N Courpied J Hamadouche M

Aims

The purpose of this retrospective study was to evaluate the minimum five-year outcome of revision total hip arthroplasty (THA) using the Kerboull acetabular reinforcement device (KARD) in patients with Paprosky type III acetabular defects and destruction of the inferior margin of the acetabulum.

Patients and Methods

We identified 36 patients (37 hips) who underwent revision THA under these circumstances using the KARD, fresh frozen allograft femoral heads, and reconstruction of the inferior margin of the acetabulum. The Merle d’Aubigné system was used for clinical assessment. Serial anteroposterior pelvic radiographs were used to assess migration of the acetabular component.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 118 - 124
1 Jan 1999
Brewster NT Gillespie WJ Howie CR Madabhushi SPG Usmani AS Fairbairn DR

In impaction grafting of contained bone defects after revision joint arthroplasty the graft behaves as a friable aggregate and its resistance to complex forces depends on grading, normal load and compaction. Bone mills in current use produce a distribution of particle sizes more uniform than is desirable for maximising resistance to shear stresses. We have performed experiments in vitro using morsellised allograft bone from the femoral head which have shown that its mechanical properties improve with increasing normal load and with increasing shear strains (strain hardening). The mechanical strength also increases with increasing compaction energy, and with the addition of bioglass particles to make good the deficiency in small and very small fragments. Donor femoral heads may be milled while frozen without affecting the profile of the particle size. Osteoporotic femoral heads provide a similar grading of sizes, although fewer particles are obtained from each specimen. Our findings have implications for current practice and for the future development of materials and techniques


The Journal of Bone & Joint Surgery British Volume
Vol. 59-B, Issue 2 | Pages 189 - 196
1 May 1977
Nade S Burwell R

This paper examines the fate of decalcified allografts (homografts) of iliac cancellous bone impregnated with autologous red marrow and implanted intermuscularly into the anterior abdominal wall of rabbits. In contrast to the findings of Urist and other workers that cortical bone decalcified with hydrochloric acid (HCl) and then freeze-dried is inductive to new bone formation in various heterotopic sites, evidence is presented that iliac bone decalcified by HCl and grafted alone to a muscular site is itself very weakly inductive to bone formation. However, when combined with autologous bone marrow the HCl-decalcified bone provides a better substrate for bone formation by marrow cells than does either undecalcified iliac bone, or iliac bone decalcified with ethylene-diamine-tetra-acetic acid. The freezing or freeze-drying of decalcified bone does not affect new bone formation when implanted alone or with autologous marrow. The differences between the cortical and cancellous bone as inductive substrates for osteogenesis are discussed and the interrelationship of bone and marrow in combined bone grafts are re-evaluated


The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 68 - 76
1 Jun 2019
Jones CW Choi DS Sun P Chiu Y Lipman JD Lyman S Bostrom MPG Sculco PK

Aims

Custom flange acetabular components (CFACs) are a patient-specific option for addressing large acetabular defects at revision total hip arthroplasty (THA), but patient and implant characteristics that affect survivorship remain unknown. This study aimed to identify patient and design factors related to survivorship.

Patients and Methods

A retrospective review of 91 patients who underwent revision THA using 96 CFACs was undertaken, comparing features between radiologically failed and successful cases. Patient characteristics (demographic, clinical, and radiological) and implant features (design characteristics and intraoperative features) were collected. There were 74 women and 22 men; their mean age was 62 years (31 to 85). The mean follow-up was 24.9 months (sd 27.6; 0 to 116). Two sets of statistical analyses were performed: 1) univariate analyses (Pearson’s chi-squared and independent-samples Student’s t-tests) for each feature; and 2) bivariable logistic regressions using features identified from a random forest analysis.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 1 | Pages 103 - 107
1 Jan 2000
Pekkarinen J Alho A Lepistö J Ylikoski M Ylinen P Paavilainen T

We have reviewed retrospectively 68 revisions of the femoral component in arthroplasties of the hip in 65 patients, using impaction bone grafting, at a median of three years (1 month to 6 years). We employed the cemented Exeter X-Change technique in 36 patients and the uncemented Bi-Metric allografting method in 32. The 37 bone defects were grade 3 or grade 4 on the Endo-Klinik classification. The Mayo hip score improved from a mean of 32 (. sd. ± 18) to 62 (. sd. ± 15). Most (25) of the 34 complications occurred in grade-3 and grade-4 defects; nine were intraoperative diaphyseal fractures and eight fractures of the greater trochanter. All the fractures united. The risk of intraoperative fracture was prevented by supporting the bone with wires in 16 hips, with reinforcement mesh in 18 and by a plate in six. Early migration of the stem of more than 10 mm during the first year indicated rotational instability; it occurred in three cases. In difficult revision cases with large defects of the femoral bone, bone-impaction techniques carry a high risk of complications


Bone & Joint 360
Vol. 7, Issue 5 | Pages 30 - 33
1 Oct 2018


Bone & Joint 360
Vol. 8, Issue 2 | Pages 2 - 8
1 Apr 2019
Shivji F Bryson D Nicolaou N Ali F


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 4 | Pages 510 - 516
1 May 2003
Langlais F Lambotte JC Collin P Langlois F Fontaine JW Thomazeau H

We used a trochanteric slide osteotomy (TSO) in 94 consecutive revision total hip arthroplasties (90 with replacement of both the cup and stem). This technique proved to be adequate for removing the components, with few complications (two minor fractures), and for implanting acetabular allografts (18%) and reinforcement devices (23%). Trochanteric union was obtained in most patients (96%), even in those with septic loosening (18/19), major femoral osteolysis (32/32), or previous trochanteric osteotomy (17/18). TSO is versatile, since it can be extended by a femoral flap (four cases) or a distal femoral window (eight cases). Despite significant bone loss, in 24% of the femora and 57% of the acetabula, favourable midterm results were achieved and only six reoperations were required, including two for trochanteric nonunion and two for loosening. It leaves the lateral femoral cortex intact so that a stem longer than 200 mm was needed in only 25% of patients. This is a considerable advantage compared with the extended trochanteric osteotomy in which the long lateral flap (12 to 14 cm) requires an average length of stem of 220 mm beyond the calcar. TSO provides an approach similar in size to the standard trochanteric osteotomy but with a rate of nonunion of 4% versus 15%. It reduces the risk of difficulties with removal of the stem, and removes the need for routine distal anchoring of long revision stems. The limited distal femoral compromise is very important in patients with a long life expectancy


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1493 - 1498
1 Nov 2018
Wagner ER Hevesi M Houdek MT Cofield RH Sperling JW Sanchez-Sotelo J

Aims

Patients with a failed reverse shoulder arthroplasty (RSA) have limited salvage options. The aim of this study was to determine the outcome of revision RSA when used as a salvage procedure for a failed primary RSA.

Patients and Methods

We reviewed all revision RSAs performed for a failed primary RSA between 2006 and 2012, excluding patients with a follow-up of less than two years. A total of 27 revision RSAs were included in the study. The mean age of the patients at the time of revision was 70 years (58 to 82). Of the 27 patients, 14 (52% were female). The mean follow-up was 4.4 years (2 to 10).


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1238 - 1247
1 Oct 2019
Soreide E Denbeigh JM Lewallen EA Thaler R Xu W Berglund L Yao JJ Martinez A Nordsletten L van Wijnen AJ Kakar S

Aims

Options for the treatment of intra-articular ligament injuries are limited, and insufficient ligament reconstruction can cause painful joint instability, loss of function, and progressive development of degenerative arthritis. This study aimed to assess the capability of a biologically enhanced matrix material for ligament reconstruction to withstand tensile forces within the joint and enhance ligament regeneration needed to regain joint function.

Materials and Methods

A total of 18 New Zealand rabbits underwent bilateral anterior cruciate ligament reconstruction by autograft, FiberTape, or FiberTape-augmented autograft. Primary outcomes were biomechanical assessment (n = 17), microCT (µCT) assessment (n = 12), histological evaluation (n = 12), and quantitative polymerase chain reaction (qPCR) analysis (n = 6).


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1609 - 1617
1 Dec 2018
Malhas AM Granville-Chapman J Robinson PM Brookes-Fazakerley S Walton M Monga P Bale S Trail I

Aims

We present our experience of using a metal-backed prosthesis and autologous bone graft to treat gross glenoid bone deficiency.

Patients and Methods

A prospective cohort study of the first 45 shoulder arthroplasties using the SMR Axioma Trabecular Titanium (TT) metal-backed glenoid with autologous bone graft. Between May 2013 and December 2014, 45 shoulder arthroplasties were carried out in 44 patients with a mean age of 64 years (35 to 89). The indications were 23 complex primary arthroplasties, 12 to revise a hemiarthroplasty or resurfacing, five for aseptic loosening of the glenoid, and five for infection.


Bone & Joint 360
Vol. 8, Issue 4 | Pages 23 - 25
1 Aug 2019


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 34 - 40
1 Jan 2019
Kraus Schmitz J Lindgren V Janarv P Forssblad M Stålman A

Aims

The aim of this study was to investigate the incidence, risk factors, and outcome of venous thromboembolism (VTE) following anterior cruciate ligament (ACL) reconstruction in a nationwide cohort.

Patients and Methods

All ACL reconstructions, primary and revision, that were recorded in the Swedish Knee Ligament Register (SKLR) between 2006 and 2013 were linked with data from the Swedish National Board of Health and Welfare. The incidence of VTE was determined by entries between the day of surgery until 90 days postoperatively based on diagnosis codes and the prescription of anticoagulants. Risk factors, outcome, and the use of thromboprophylaxis were analyzed. Descriptive statistics with multivariate analysis were used to describe the findings.