Advertisement for orthosearch.org.uk
Results 381 - 400 of 760
Results per page:
The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1081 - 1086
1 Sep 2019
Murphy WS Harris S Pahalyants V Zaki MM Lin B Cheng T Talmo C Murphy SB

Aims

The practice of alternating operating theatres has long been used to reduce surgeon idle time between cases. However, concerns have been raised as to the safety of this practice. We assessed the payments and outcomes of total knee arthroplasty (TKA) performed during overlapping and nonoverlapping days, also comparing the total number of the surgeon’s cases and the total time spent in the operating theatre per day.

Materials and Methods

A retrospective analysis was performed on the Centers for Medicare & Medicaid Services (CMS) Limited Data Set (LDS) on all primary elective TKAs performed at the New England Baptist Hospital between January 2013 and June 2016. Using theatre records, episodes were categorized into days where a surgeon performed overlapping and nonoverlapping lists. Clinical outcomes, economic outcomes, and demographic factors were calculated. A regression model controlling for the patient-specific factors was used to compare groups. Total orthopaedic cases and aggregate time spent operating (time between skin incision and closure) were also compared.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 449 - 454
1 Apr 2006
Hart AJ Hester T Sinclair K Powell JJ Goodship AE Pele L Fersht NL Skinner J

We have studied the relationship between metal ion levels and lymphocyte counts in patients with metal-on-metal hip resurfacings. Peripheral blood samples were analysed for lymphocyte subtypes and whole blood cobalt and chromium ion levels in 68 patients (34 with metal-on-metal hip resurfacings and 34 with standard metal-on-polyethylene total hip replacements). All hip components were radiologically well-fixed and the patients were asymptomatic. Cobalt and chromium levels were significantly elevated in the patients with metal-on-metal hip resurfacings, compared with the patients with standard metal-on-polyethylene designs (p < 0.0001). There was a statistically significant decrease in the level of CD8. +. cells (T-cytotoxic/suppressor) (p = 0.005) in the metal-on-metal hip resurfacing group. A threshold level of blood cobalt and chromium ions was associated with reduced CD8. +. T-cell counts. We have no evidence that our patients suffered as a result of this reduced level of CD8. +. T-cells


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 12 | Pages 1675 - 1680
1 Dec 2005
Howie C Hughes H Watts AC

This population-based study investigated the incidence and trends in venous thromboembolic disease after total hip and knee arthroplasty over a ten-year period. Death or readmission for venous thromboembolic disease up to two years after surgery for all patients in Scotland was the primary outcome. The incidence of venous thromboembolic disease, including fatal pulmonary embolism, three months after surgery was 2.27% for primary hip arthroplasty and 1.79% for total knee arthroplasty. The incidence of fatal pulmonary embolism within three months was 0.22% for total hip arthroplasty and 0.15% for total knee arthroplasty. The majority of events occurred after hospital discharge, with no apparent trend over the period. The data support current advice that prophylaxis should be continued for at least six weeks following surgery. Despite the increased use of policies for prophylaxis and earlier mobilisation, there has been no change in the incidence of venous thromboembolic disease


Bone & Joint 360
Vol. 8, Issue 4 | Pages 42 - 44
1 Aug 2019


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 5 | Pages 544 - 547
1 Nov 1983
Verberne G

Twenty patients each with a fractured femoral neck had a prosthesis with a built-in ball-and-socket joint inserted. Movements at the built-in joint were compared with total hip movement immediately after operation, one month later and three months later. It was found that the built-in joint soon lost mobility and at three months was almost completely stiff. Consequently such joints cannot be expected to prevent the acetabular erosion which is liable to follow femoral head replacement for fracture


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 6 | Pages 985 - 987
1 Nov 1990
Blomgren G Hoborn J Nystrom B

We assessed wound, air and operative field contamination at 50 total hip operations, performed in a zonal ventilation system. Theatre staff wore either a specially designed polypropylene non-woven coverall or conventional cotton shirt and trousers. The surgeons wore partially impermeable operating gowns. The polypropylene coverall was associated with significantly lower air and wound counts. The coverall was warmer than cotton but judged to be acceptable. The combined use of zonal ventilation and the coverall achieved ultra-clean air conditions


Bone & Joint 360
Vol. 8, Issue 4 | Pages 16 - 19
1 Aug 2019


Bone & Joint Research
Vol. 8, Issue 10 | Pages 451 - 458
1 Oct 2019
Kuroda Y Tanaka T Miyagawa T Kawai T Goto K Tanaka S Matsuda S Akiyama H

Objectives

Using a simple classification method, we aimed to estimate the collapse rate due to osteonecrosis of the femoral head (ONFH) in order to develop treatment guidelines for joint-preserving surgeries.

Methods

We retrospectively analyzed 505 hips from 310 patients (141 men, 169 women; mean age 45.5 years (sd 14.9; 15 to 86)) diagnosed with ONFH and classified them using the Japanese Investigation Committee (JIC) classification. The JIC system includes four visualized types based on the location and size of osteonecrotic lesions on weightbearing surfaces (types A, B, C1, and C2) and the stage of ONFH. The collapse rate due to ONFH was calculated using Kaplan–Meier survival analysis, with radiological collapse/arthroplasty as endpoints.


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 753 - 754
1 Jul 2019
Haddad FS


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 951 - 959
1 Aug 2019
Preston N McHugh GA Hensor EMA Grainger AJ O’Connor PJ Conaghan PG Stone MH Kingsbury SR

Aims

This study aimed to develop a virtual clinic for the purpose of reducing face-to-face orthopaedic consultations.

Patients and Methods

Anonymized experts (hip and knee arthroplasty patients, surgeons, physiotherapists, radiologists, and arthroplasty practitioners) gave feedback via a Delphi Consensus Technique. This consisted of an iterative sequence of online surveys, during which virtual documents, made up of a patient-reported questionnaire, standardized radiology report, and decision-guiding algorithm, were modified until consensus was achieved. We tested the patient-reported questionnaire on seven patients in orthopaedic clinics using a ‘think-aloud’ process to capture difficulties with its completion.


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1218 - 1229
1 Oct 2019
Lerch TD Eichelberger P Baur H Schmaranzer F Liechti EF Schwab JM Siebenrock KA Tannast M

Aims

Abnormal femoral torsion (FT) is increasingly recognized as an additional cause for femoroacetabular impingement (FAI). It is unknown if in-toeing of the foot is a specific diagnostic sign for increased FT in patients with symptomatic FAI. The aims of this study were to determine: 1) the prevalence and diagnostic accuracy of in-toeing to detect increased FT; 2) if foot progression angle (FPA) and tibial torsion (TT) are different among patients with abnormal FT; and 3) if FPA correlates with FT.

Patients and Methods

A retrospective, institutional review board (IRB)-approved, controlled study of 85 symptomatic patients (148 hips) with FAI or hip dysplasia was performed in the gait laboratory. All patients had a measurement of FT (pelvic CT scan), TT (CT scan), and FPA (optical motion capture system). We allocated all patients to three groups with decreased FT (< 10°, 37 hips), increased FT (> 25°, 61 hips), and normal FT (10° to 25°, 50 hips). Cluster analysis was performed.


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 1 | Pages 58 - 62
1 Jan 1989
Langlais F Vielpeau C

Four en-bloc resections for malignant tumours of the hip, the peri-acetabular region and the iliac wing were reconstructed using an irradiated hemipelvic allograft together with a total hip prosthesis. Technical aspects include the use of an anterior Enneking approach which excises the previous biopsy site, division and re-attachment of the iliac crest and fixation of the prosthesis using a modified acetabular cup and three polypropylene artificial ligaments to increase the stability of the joint. Weight-bearing was allowed at three months. The oncological and clinical results were satisfactory after a mean follow-up of 19 months, with walking distances of 500 metres to two kilometres without pain


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 12 | Pages 1631 - 1635
1 Dec 2005
von Schewelov T Sanzén L Önsten I Carlsson Å Besjakov J

We investigated the wear characteristics and clinical performance of four different total hip joint articulations in 114 patients. Wear and migration was measured by roentgenstereophotogrammetric analysis at five years or at the last follow-up. The mean annual wear was 0.11 mm for a stainless steel/Enduron articulation, 0.34 mm for stainless steel/Hylamer cup, 0.17 mm for zirconium oxide ceramic/Enduron and 0.40 mm for zirconium oxide ceramic/Hylamer. The difference between the groups was significant (p < 0.008) except for stainless steel/Hylamer vs zirconium oxide ceramic/Hylamer (p = 0.26). At present, 12 patients have undergone a revision procedure, four at five years and eight thereafter. No patient who received a stainless steel/Enduron articulation at their primary replacement required revision. Conflicting results have been reported about the performance of the zirconium oxide ceramic femoral head, but our findings suggest that it should not be used with a polymethylmethacrylate acetabular component. Hylamer has already been withdrawn from the market


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 3 | Pages 371 - 373
1 May 1997
Nicolai P Aldam CH Allen PW

An intact barrier between the hands of the surgeon and the patient remains the single most important factor in protection against infection for both. Increasing the awareness of possible glove perforation without skin penetration will decrease the risk of contamination. We performed a prospective, randomised trial comparing the incidence of glove perforation using a new type of glove (Regent Biogel Reveal) and standard double-gloves in total hip and knee replacement. One or more perforations was detected in 14.6% of all gloves. The new gloves increased significantly the awareness of perforation. Multiple perforations at the base of the ring finger were found in surgeons who wore wedding rings during the operation and we recommend that rings be removed before undertaking surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 59-B, Issue 3 | Pages 293 - 297
1 Aug 1977
Hunter G Dandy D

Deep infection, the most serious local complication of total hip replacement, prompted a study of the records of 135 patients (137 hips) thus afflicted in a nationwide survey of Canada. Particular attention has been paid to the natural history of the infection, and the problems of diagnosis are described. Twenty-one patients died after the insertion, or removal, of the prosthesis, and of the survivors of the original 135 patients only eighteen have been able to retain the prosthesis without further problems with the wound. The remaining patients had the prosthesis removed, and most dry wounds. Certain suggestions are made on management. The advice that a second total hip prosthesis should be inserted after a deep infection of the first implant is not supported


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 3 | Pages 468 - 474
1 May 1993
Schuller H Dalstra M Huiskes R Marti R

In acetabular dysplasia, fixation of the acetabular component of a cemented total hip prosthesis may be insecure and superolateral bone grafts are often used to augment the acetabular roof. We used finite element analysis to study the mechanical importance of the lateral acetabular roof and found that the lateral acetabular rim plays an important role in the load transfer of the pelvic bone. When the superlateral rim was lacking, the load shifted to the posterosuperior rim and to the area of pubic support, and the stresses in all materials, especially in the cement and in the trabecular bone, increased greatly. At the cement-bone interface the tilting component of the shear stress increased threefold. In a model in which the dysplastic acetabulum was augmented by a rigidly fixed, load-transmitting bone graft, the stresses were considerably diminished


The Journal of Bone & Joint Surgery British Volume
Vol. 61-B, Issue 4 | Pages 419 - 421
1 Nov 1979
Hunter G Welsh R Cameron H Bailey W

The results of 140 total hip revision procedures for "non-septic" loosening, dislocation, and fracture of the femoral stem or shaft have been personally reviewed and rated by the Harris method. The minimum follow-up period was six months: thirty-three (24 per cent) showed excellent or good results, seventy-two (51 per cent) showed fair or poor results. Subsequent excision arthroplasty was performed in thirty-one patients. The infection rate for these revision procedures was very high, suggesting that many were already infected at the time of revision, and that every "loose" hip must be assumed to be infected until proved otherwise. The mortality rate of 3 per cent was surprisingly low after more than one major surgical procedure in these elderly patients


The Journal of Bone & Joint Surgery British Volume
Vol. 58-B, Issue 1 | Pages 79 - 83
1 Feb 1976
Feith R Slooff T Kazem I van Rens T

In a series of seventeen patients with unilateral osteoarthritis of the hip a scintiscanning follow-up study was made before and after total hip replacement for the assessment of the normal course of the 87mSr-scintiscan. In another series of twenty-eight patients with total hip replacement a photoscan was made as a supplement for the diagnosis of loosening of one or both components of a total hip implant. In most of these cases it proved to be a useful method, especially when clinical and raidological examination was inconclusive. It is concluded that up to six months after operation increased osteoblastic activity exists; the scintiscan became normal after that time. 87mSr scintiscanning offers a safe and simple technique for the assessment of the success and stability of total hip arthroplasty. It is also a useful aid for the early detection of loosening and infection. The procedure can help in the differential diagnosis of complaints after total hip replacement


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 800 - 807
1 Jul 2019
Hampton SN Nakonezny PA Richard HM Wells JE

Aims

Psychological factors play a critical role in patient presentation, satisfaction, and outcomes. Pain catastrophizing, anxiety, and depression are important to consider, as they are associated with poorer outcomes and are potentially modifiable. The aim of this study was to assess the level of pain catastrophizing, anxiety, and depression in patients with a range of hip pathology and to evaluate their relationship with patient-reported psychosocial and functional outcome measures.

Patients and Methods

Patients presenting to a tertiary-centre specialist hip clinic were prospectively evaluated for outcomes of pain catastrophizing, anxiety, and depression. Validated assessments were undertaken such as: the Pain Catastrophizing Scale (PCS), the Hospital Anxiety Depression Scale (HADS), and the 12-Item Short-Form Health Survey (SF-12). Patient characteristics and demographics were also recorded. Multiple linear regression modelling, with adaptive least absolute shrinkage and selection operator (LASSO) variable selection, was used for analysis.


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 838 - 847
1 Jul 2019
Robinson PG Clement ND Hamilton D Blyth MJG Haddad FS Patton JT

Aims

Robotic-assisted unicompartmental knee arthroplasty (UKA) promises accurate implant placement with the potential of improved survival and functional outcomes. The aim of this study was to present the current evidence for robotic-assisted UKA and describe the outcome in terms of implant positioning, range of movement (ROM), function and survival, and the types of robot and implants that are currently used.

Materials and Methods

A search of PubMed and Medline was performed in October 2018 in line with the Preferred Reporting Items for Systematic Review and Meta-Analysis statement. Search terms included “robotic”, “knee”, and “surgery”. The criteria for inclusion was any study describing the use of robotic UKA and reporting implant positioning, ROM, function, and survival for clinical, cadaveric, or dry bone studies.