Advertisement for orthosearch.org.uk
Results 21 - 40 of 266
Results per page:

Aims. The aim of this study was to assess and compare active rotation of the forearm in normal subjects after the application of a short-arm cast (SAC) in the semisupination position and a long-arm cast (LAC) in the neutral position. A clinical study was also conducted to compare the functional outcomes of using a SAC in the semisupination position with those of using a LAC in the neutral position in patients who underwent arthroscopic triangular fibrocartilage complex (TFCC) foveal repair. Methods. A total of 40 healthy right-handed volunteers were recruited. Active pronation and supination of the forearm were measured in each subject using a goniometer. In the retrospective clinical study, 40 patients who underwent arthroscopic foveal repair were included. The wrist was immobilized postoperatively using a SAC in the semisupination position (approximately 45°) in 16 patients and a LAC in 24. Clinical outcomes were assessed using grip strength and patient-reported outcomes. The degree of disability caused by cast immobilization was also evaluated when the cast was removed. Results. Supination was significantly more restricted with LACs than with SACs in the semisupination position in male and female patients (p < 0.001 for both). However, pronation was significantly more restricted with SACs in the semisupination position than with LACs in female patients (p = 0.003) and was not significantly different in male patients (p = 0.090). In the clinical study, both groups showed improvement in all parameters with significant differences in grip strength, visual analogue scale scores for pain, modified Mayo Wrist Score, the Disability of the Arm, Shoulder, and Hand (DASH) score, and the Patient-Rated Wrist Evaluation (PRWE) score. No significant postoperative differences were noted between LACs and SACs in the semisupination position. However, the disability caused by immobilization in a cast was significantly higher in patients who had a LAC on the dominant hand (p < 0.001). Conclusion. We found that a SAC in the semisupination position is as effective as a LAC in restricting pronation of the forearm. In addition, postoperative immobilization with a SAC in the semisupination position resulted in comparable pain scores and functional outcomes to immobilization with a LAC after TFCC foveal repair, with less restriction of daily activities. Therefore, we recommend that surgeons consider using a SAC in the semisupination position for postoperative immobilization following TFCC foveal repair for dorsal instability of the distal radioulnar joint. Cite this article: Bone Joint J 2022;104-B(2):249–256


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 366 - 372
1 Feb 2021
Sun Z Li J Luo G Wang F Hu Y Fan C

Aims. This study aimed to determine the minimal detectable change (MDC), minimal clinically important difference (MCID), and substantial clinical benefit (SCB) under distribution- and anchor-based methods for the Mayo Elbow Performance Index (MEPI) and range of movement (ROM) after open elbow arthrolysis (OEA). We also assessed the proportion of patients who achieved MCID and SCB; and identified the factors associated with achieving MCID. Methods. A cohort of 265 patients treated by OEA were included. The MEPI and ROM were evaluated at baseline and at two-year follow-up. Distribution-based MDC was calculated with confidence intervals (CIs) reflecting 80% (MDC 80), 90% (MDC 90), and 95% (MDC 95) certainty, and MCID with changes from baseline to follow-up. Anchor-based MCID (anchored to somewhat satisfied) and SCB (very satisfied) were calculated using a five-level Likert satisfaction scale. Multivariate logistic regression of factors affecting MCID achievement was performed. Results. The MDC increased substantially based on selected CIs (MDC 80, MDC 90, and MDC 95), ranging from 5.0 to 7.6 points for the MEPI, and from 8.2° to 12.5° for ROM. The MCID of the MEPI were 8.3 points under distribution-based and 12.2 points under anchor-based methods; distribution- and anchor-based MCID of ROM were 14.1° and 25.0°. The SCB of the MEPI and ROM were 17.3 points and 43.4°, respectively. The proportion of the patients who attained anchor-based MCID for the MEPI and ROM were 74.0% and 94.7%, respectively; furthermore, 64.2% and 86.8% attained SCB. Non-dominant arm (p = 0.022), higher preoperative MEPI rating (p < 0.001), and postoperative visual analogue scale pain score (p < 0.001) were independent predictors of not achieving MCID for the MEPI, while atraumatic causes (p = 0.040) and higher preoperative ROM (p = 0.005) were independent risk factors for ROM. Conclusion. In patients undergoing OEA, the MCID for the increased MEPI is 12.2 points and 25° increased ROM. The SCB is 17.3 points and 43.3°, respectively. Future studies using the MEPI and ROM to assess OEA outcomes should report not only statistical significance but also clinical importance. Cite this article: Bone Joint J 2021;103-B(2):366–372


The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1190 - 1196
1 Sep 2017
Swarup I Henn CM Nguyen JT Dines DM Craig EV Warren RF Gulotta LV Henn III RF

Aims . Few studies have evaluated the relationship between patients’ pre-operative expectations and the outcome of orthopaedic procedures. Our aim was to determine the effect of expectations on the outcome after primary anatomical total shoulder arthroplasty (TSA). We hypothesised that patients with greater expectations would have better outcomes. . Patients and Methods. Patients undergoing primary anatomical TSA completed the Hospital for Special Surgery’s Shoulder Expectations Survey pre-operatively. The American Shoulder and Elbow Surgeons (ASES), Shoulder Activity Scale (SAS), Short-Form-36 (SF-36), and visual analogue scale (VAS) for pain, fatigue, and general health scores were also collected pre-operatively and two years post-operatively. Pearson correlations were used to assess the relationship between the number of expectations and the outcomes. Differences in outcomes between those with higher and lower levels of expectations for each expectation were assessed by independent samples t-test. Multivariable linear regression analysis was used to control for potential confounding factors. Results. A total of 67 patients were evaluated two years post-operatively. Most parameters of outcome improved significantly from baseline and most patients were satisfied. A greater number of expectations was associated with a significantly greater improvement in the ASES score (p = 0.02). In the multivariable analysis, a greater number of expectations was an independent predictor of better ASES, VAS and SF-36 scores, as well as improvements in ASES and VAS pain scores (p < 0.05). Greater expectations for many specific expectation questions were significantly associated with better outcomes (p < 0.05). Conclusion. TSA is a successful procedure with significant improvements in outcome, and greater pre-operative expectations are associated with better outcomes. . Cite this article: Bone Joint J 2017;99-B:1190–6


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 939 - 945
1 May 2021
Kakar S Logli AL Ramazanian T Gaston RG Fowler JR

Aims. The purpose was to evaluate early clinical, patient-reported, and radiological outcomes of the scapholunate ligament 360° tenodesis (SL 360) technique for treatment of scapholunate (SL) instability. Methods. We studied the results of nine patients (eight males and one female with a mean age of 44.7 years (26 to 55)) who underwent the SL 360 procedure for reducible SL instability between January 2016 and June 2019, and who were identified from retrospective review of electronic medical records. Final follow-up of any kind was a mean of 33.7 months (12.0 to 51.3). Clinical, radiological, and patient-reported outcome data included visual analogue scale (VAS) for pain, Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH), Mayo Wrist Score (MWS), and Patient-Rated Wrist Examination (PRWE). Means were analyzed using paired t-test. Results. Before surgery, patients with SL instability were significantly impaired with respect to wrist flexion, extension, and grip strength (mean flexion, 51° (20° to 85°) vs 73° (45° to 90°); mean extension, 46° (15° to 70°) vs 66° (45° to 80°); mean grip strength, 25 kg (20 to 31) vs 50 kg (35 to 68) compared to the unaffected side). The mean SL gap (4.9 mm (2.3 to 7.3) vs 2.1 mm (1.6 to 2.9)) and mean SL angle (71° (59° to 105°) vs 50° (38° to 64°) were also significantly greater in the affected wrist. At final follow-up, there was mean improvement regarding clinical, radiological, and functional outcomes comparing preoperative to final postoperative values for the VAS for pain scale, QuickDASH, MWS, PRWE, and SL gap and SL angle. Conclusion. In our small series, the SL 360 procedure for reducible SL instability has favourable early clinical, patient-reported, and radiological outcomes at a mean of 33.7 months (12.0 to 51.3). The suture tape and tendon construct confers robust stability, permitting earlier mobilization without the inherent disadvantages of Kirschner wire stabilization. Cite this article: Bone Joint J 2021;103-B(5):939–945


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 353 - 359
1 Feb 2021
Cho C Min B Bae K Lee K Kim DH

Aims. Ultrasound (US)-guided injections are widely used in patients with conditions of the shoulder in order to improve their accuracy. However, the clinical efficacy of US-guided injections compared with blind injections remains controversial. The aim of this study was to compare the accuracy and efficacy of US-guided compared with blind corticosteroid injections into the glenohumeral joint in patients with primary frozen shoulder (FS). Methods. Intra-articular corticosteroid injections were administered to 90 patients primary FS, who were randomly assigned to either an US-guided (n = 45) or a blind technique (n = 45), by a shoulder specialist. Immediately after injection, fluoroscopic images were obtained to assess the accuracy of the injection. The outcome was assessed using a visual analogue scale (VAS) for pain, the American Shoulder and Elbow Surgeons (ASES) score, the subjective shoulder value (SSV) and range of movement (ROM) for all patients at the time of presentation and at three, six, and 12 weeks after injection. Results. The accuracy of injection in the US and blind groups was 100% (45/45) and 71.1% (32/45), respectively; this difference was significant (p < 0.001). Both groups had significant improvements in VAS pain score, ASES score, SSV, forward flexion, abduction, external rotation, and internal rotation throughout follow-up until 12 weeks after injection (all p < 0.001). There were no significant differences between the VAS pain scores, the ASES score, the SSV and all ROMs between the two groups at the time points assessed (all p > 0.05). No injection-related adverse effects were noted in either group. Conclusion. We found no significant differences in pain and functional outcomes between the two groups, although an US-guided injection was associated with greater accuracy. Considering that it is both costly and time-consuming, an US-guided intra-articular injection of corticosteroid seems not always to be necessary in the treatment of FS as it gives similar outcomes as a blind injection. Cite this article: Bone Joint J 2021;103-B(2):353–359


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 829 - 833
1 Jun 2016
Hou Y Nie L Pan X Si M Han Y Li J Zhang H

Aims. In order to evaluate the effectiveness of the Mobi-C implant in cervical disc degeneration, a randomised study was conducted, comparing the Mobi-C prosthesis arthroplasty with anterior cervical disc fusion (ACDF) in patients with single level cervical spondylosis. Patients and Methods. From January 2008 to July 2009, 99 patients were enrolled and randomly divided into two groups, those having a Mobi-C implant (n = 51; 30 men, 21 women) and those undergoing ACDF (n = 48; 28 men, 20 women).The patients were followed up for five years, with the primary outcomes being the Japanese Orthopaedic Association score, visual analogue scale for pain and the incidence of further surgery. The secondary outcomes were the Neck Disability Index and range of movement (ROM) of the treated segment. Results. The incidence of further surgery was found to be statistically significant between the two groups (p = 0.49), with seven ACDF patients requiring further surgery and only one Mobi-C patient requiring re-operation. There were significant differences (p < 0.001) between the two groups in the ROM of the treated segment. However, both Mobi-C surgery and ACDF surgery were effective in improving the patient’s clinical symptoms. Take home message: Mobi-C implant surgery is a safe alternative to ACDF surgery in cervical disc degeneration. Cite this article: Bone Joint J 2016;98-B:829–3


The Bone & Joint Journal
Vol. 103-B, Issue 6 | Pages 1155 - 1159
1 Jun 2021
Jamshidi K Zandrahimi F Bagherifard A Mohammadi F Mirzaei A

Aim. There is insufficient evidence to support bony reconstruction of the pubis after a type III internal hemipelvectomy (resection of all or part of the pubis). In this study, we compared surgical complications, postoperative pain, and functional outcome in a series of patients who had undergone a type III internal hemipelvectomy with or without bony reconstruction. Methods. In a retrospective cohort study, 32 patients who had undergone a type III hemipelvectomy with or without allograft reconstruction (n = 15 and n = 17, respectively) were reviewed. The mean follow-up was 6.7 years (SD 3.8) for patients in the reconstruction group and 6.1 years (SD 4.0) for patients in the non-reconstruction group. Functional outcome was evaluated using the Musculoskeletal Tumor Society (MSTS) scoring system and the level of postoperative pain with a visual analogue scale (VAS). Results. The mean MSTS score of the patients was significantly better in patients after reconstruction (26 (SD 1.7) vs 22.7 (SD 2.0); p < 0.001). The mean visual analogue scale score for pain was significantly less in the reconstruction group (2.1 (SD 2) vs 4.2 (SD 2.2); p = 0.016). One infection occurred in each group. Bladder herniation occurred in three patients (17.6%) in the non-reconstruction group but none in the reconstruction group. Five patients (29.4%) in the non-reconstruction group and one (7%) in the reconstruction group had a limp. Graft displacement occurred in two patients in the reconstruction group. Conclusion. We recommend reconstruction of the bony defect after a type III hemipelvectomy: it gives a better functional result, less postoperative pain, and fewer late surgical complications. Cite this article: Bone Joint J 2021;103-B(6):1155–1159


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 967 - 972
1 Jul 2015
Hussey MM Hussey SE Mighell MA

Failed internal fixation of a fracture of the proximal humerus produces many challenges with limited surgical options. The aim of this study was to evaluate the clinical outcomes after the use of a reverse shoulder arthroplasty under these circumstances. Between 2007 and 2012, 19 patients (15 women and four men, mean age 66 years; 52 to 82) with failed internal fixation after a proximal humeral fracture, underwent implant removal and reverse shoulder arthroplasty (RSA). The mean follow-up was 36 months (25 to 60). The mean American Shoulder and Elbow Score improved from 27.8 to 50.1 (p = 0.019). The mean Simple Shoulder Test score improved from 0.7 to 3.2 (p = 0.020), and the mean visual analogue scale for pain improved from 6.8 to 4.3 (p = 0.012). Mean forward flexion improved from 58.7° to 101.1° (p < 0.001), mean abduction from 58.7° to 89.1° (p = 0.012), mean external rotation from 10.7° to 23.1° (p = 0.043) and mean internal rotation from buttocks to L4 (p = 0.034). A major complication was recorded in five patients (26%) (one intra-operative fracture, loosening of the humeral component in two and two peri-prosthetic fractures). A total of 15 patients (79%) rated their outcome as excellent or good, one (5%) as satisfactory, and three (16%) as unsatisfactory. . An improvement in outcomes and pain can be expected when performing a RSA as a salvage procedure after failed internal fixation of a fracture of the proximal humerus. Patients should be cautioned about the possibility for major complications following this technically demanding procedure. Cite this article: Bone Joint J 2015;97-B:967–72


Bone & Joint 360
Vol. 13, Issue 2 | Pages 23 - 26
1 Apr 2024

The April 2024 Foot & Ankle Roundup360 looks at: Safety of arthroscopy combined with radial extracorporeal shockwave therapy for osteochondritis of the talus; Bipolar allograft transplantation of the ankle; Identifying risk factors for osteonecrosis after talar fracture; Balancing act: immediate versus delayed weightbearing in ankle fracture recovery; Levelling the field: proximal supination osteotomy’s efficacy in severe and super-severe hallux valgus; Restoring balance: how adjusting the tibiotalar joint line influences movement after ankle surgery.


Bone & Joint 360
Vol. 13, Issue 4 | Pages 26 - 29
2 Aug 2024

The August 2024 Shoulder & Elbow Roundup360 looks at: Comparing augmented and nonaugmented locking-plate fixation for proximal humeral fractures in the elderly; Elevated five-year mortality following shoulder arthroplasty for fracture; Total intravenous anaesthesia with propofol reduces discharge times compared with inhaled general anaesthesia in shoulder arthroscopy: a randomized controlled trial; The influence of obesity on outcomes following arthroscopic rotator cuff repair; Humeral component version has no effect on outcomes following reverse total shoulder arthroplasty: a prospective, double-blinded, randomized controlled trial; What is a meaningful improvement after total shoulder arthroplasty by implant type, preoperative diagnosis, and sex?; The safety of corticosteroid injection prior to shoulder arthroplasty: a systematic review; Mortality and subsequent fractures of patients with olecranon fractures compared to other upper limb osteoporotic fractures.


Bone & Joint 360
Vol. 12, Issue 1 | Pages 23 - 25
1 Feb 2023

The February 2023 Foot & Ankle Roundup360 looks at: Joint inflammatory response in ankle and pilon fractures; Tibiotalocalcaneal fusion with a custom cage; Topical application of tranexamic acid can reduce blood loss in calcaneal fractures; Risk factors for failure of total ankle arthroplasty; Pain catastrophizing: the same as pain forecasting?.


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1189 - 1195
1 Nov 2023
Kim JS Kim SH Kim SC Park JH Kim HG Lee SM Yoo JC

Aims

The aim of this study was to compare the clinical and radiological outcomes of reverse shoulder arthroplasty (RSA) using small and standard baseplates in Asian patients, and to investigate the impact of a mismatch in the sizes of the glenoid and the baseplate on the outcomes.

Methods

This was retrospective analysis of 50 and 33 RSAs using a standard (33.8 mm, ST group) and a small (29.5 mm, SM group) baseplate of the Equinoxe reverse shoulder system, which were undertaken between January 2017 and March 2021. Radiological evaluations included the size of the glenoid, the β-angle, the inclination of the glenoid component, inferior overhang, scapular notching, the location of the central cage in the baseplate within the vault and the mismatch in size between the glenoid and baseplate. Clinical evaluations included the range of motion (ROM) and functional scores. In subgroup analysis, comparisons were performed between those in whom the vault of the glenoid was perforated (VP group) and those in whom it was not perforated (VNP group).


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 483 - 488
1 Apr 2017
Pinsornsak P Nangnual S Boontanapibul K

Aims. Multimodal infiltration of local anaesthetic provides effective control of pain in patients undergoing total knee arthroplasty (TKA). There is little information about the added benefits of posterior capsular infiltration (PCI) using different combinations of local anaesthetic agents. Our aim was to investigate the effectiveness of the control of pain using multimodal infiltration with and without infiltration of the posterior capsule of the knee. Patients and Methods. In a double-blind, randomised controlled trial of patients scheduled for unilateral primary TKA, 86 were assigned to be treated with multimodal infiltration with (Group I) or without (Group II) PCI. Routine associated analgesia included the use of bupivacaine, morphine, ketorolac and epinephrine. All patients had spinal anaesthesia and patient-controlled analgesia (PCA) post-operatively. A visual analogue scale (VAS) for pain and the use of morphine were recorded 24 hours post-operatively. Side effects of the infiltration, blood loss, and length of stay in hospital were recorded. Results. There were no statistically significant differences between the groups in relation to: VAS pain scores in the first 24 hours post-operatively (p = 0.693), the use of morphine in the PCA (p = 0.647), blood loss (p = 0.625), and length of stay (p = 0.17). There were no neurovascular complications in either group. Conclusion. The multimodal infiltration of local anaesthetic with infiltration of the posterior capsule did not provide significant added analgesic benefits or reduce the use of morphine after TKA. Multimodal infiltration is a satisfactory technique for the management of pain in these patients without the attendant risks of PCI. Cite this article: Bone Joint J 2017; 99-B:483–8


Bone & Joint 360
Vol. 12, Issue 4 | Pages 23 - 26
1 Aug 2023

The August 2023 Wrist & Hand Roundup360 looks at: Complications and patient-reported outcomes after trapeziectomy with a Weilby sling: a cohort study; Swelling, stiffness, and dysfunction following proximal interphalangeal joint sprains; Utility of preoperative MRI for assessing proximal fragment vascularity in scaphoid nonunion; Complications and outcomes of operative treatment for acute perilunate injuries: a systematic review; The position of the median nerve in relation to the palmaris longus tendon at the wrist: a study of 784 MR images; Basal fractures of the ulnar styloid? A randomized controlled trial; Proximal row carpectomy versus four-corner arthrodesis in SLAC and SNAC wrist; Managing cold intolerance after hand injury: a systematic review.


Bone & Joint 360
Vol. 13, Issue 4 | Pages 23 - 26
2 Aug 2024

The August 2024 Wrist & Hand Roundup360 looks at: Methotrexate shows potential in reducing pain for hand osteoarthritis with synovitis; Circumferential casting versus plaster splinting in adult distal radius fractures: the CAST study findings; Surgery shows superior long-term success for Dupuytren contracture compared to needle fasciotomy and collagenase injection; Evolving trends in surgical management of wrist arthritis: a decade-long national analysis; Mid-term outcomes of three commonly used surgical reconstructions for scapholunate instability; SLAC and SNAC: what is the evidence for treatment?; Steroids for trapeziometacarpal osteoarthritis?; When is it safe to return to driving after distal radius fracture fixation? A prospective study.


Bone & Joint 360
Vol. 12, Issue 1 | Pages 26 - 29
1 Feb 2023

The February 2023 Wrist & Hand Roundup360 looks at: ‘Self-care’ protocol for minimally displaced distal radius fractures; Treatment strategies for acute Seymour fractures in children and adolescents: including crushed open fractures; Routinely collected outcomes of proximal row carpectomy; Moving minor hand surgeries in the office-based procedure room: a population-based trend analysis; A comparison between robotic-assisted scaphoid screw fixation and a freehand technique for acute scaphoid fracture: a randomized, controlled trial; Factors associated with conversion to surgical release after a steroid injection in patients with a trigger finger; Two modern total wrist arthroplasties: a randomized comparison; Triangular fibrocartilage complex suture repair reliable even in ulnar styloid nonunion.


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 939 - 944
1 Jul 2016
Boonen B Schotanus MGM Kerens B van der Weegen W Hoekstra HJ Kort NP

Aims. We wished to compare the clinical outcome, as assessed by questionnaires and the rate of complications, in total knee arthroplasty (TKA) undertaken with patient-matched positioning guides (PMPGs) or conventional instruments. Patients and Methods. A total of 180 patients (74 men, 106 women; mean age 67 years) were included in a multicentre, adequately powered, double-blind, randomised controlled trial. The mean follow-up was 44 months (24 to 57). Results. There were no significant or clinically relevant differences between the two groups for all outcome measures (Knee Society Score, p = 0.807; Oxford Knee Score, p = 0.304; Western Ontario and McMaster osteoarthritis index, p = 0.753; visual analogue scale for pain, p = 0.227; EuroQol-5D-3L index score, p = 0.610; EuroQol-5D-3L VAS health, p = 0.968.) There was no difference in the rate of complications (p = 0.291). . Conclusion. PMPGs are already in relatively common use and their short-term clinical results are equal to conventional instrumented TKA. Cite this article: Bone Joint J 2016;98-B:939–44


Bone & Joint 360
Vol. 13, Issue 4 | Pages 19 - 23
2 Aug 2024

The August 2024 Foot & Ankle Roundup360 looks at: ESWT versus surgery for fifth metatarsal stress fractures; Minimally invasive surgery versus open fusion for hallux rigidus; Diabetes and infection risk in total ankle arthroplasty; Is proximal medial gastrocnemius recession useful for managing chronic plantar fasciitis?; Fuse the great toe in the young!; Conservative surgery for diabetic foot osteomyelitis; Mental health and outcome following foot and ankle surgery.


The Bone & Joint Journal
Vol. 102-B, Issue 11 | Pages 1555 - 1559
1 Nov 2020
Sebastia-Forcada E Lizaur-Utrilla A Mahiques-Segura G Ruiz-Lozano M Lopez-Prats FA Alonso-Montero C

Aims. The purpose of this study was to determine whether there were long-term differences in outcomes of reverse shoulder arthroplasty (RSA) undertaken for acute proximal humeral fracture versus rotator cuff deficiency with a minimum follow-up of five years. Methods. This was a prospective cohort study comparing 67 patients with acute complex proximal humeral fracture and 64 patients with irreparable rotator cuff deficiency who underwent primary RSA. In the fracture group, there were 52 (77.6%) females and 15 (22.4%) males, with a mean age of 73.5 years (51 to 85), while in the arthropathy group, there were 43 (67.1%) females and 21 (32.9%) males, with a mean age of 70.6 years (50 to 84). Patients were assessed by the Constant score, University of California Los Angeles shoulder score (UCLA), short version of the Disability of the Arm Shoulder and Hand score (QuickDASH), and visual analogue scales (VAS) for pain and satisfaction. Radiological evaluation was also performed. Results. Mean follow-up was 8.4 years (5 to 11). There were no significant differences in mean absolute (p = 0.125) or adjusted (p = 0.569) Constant, UCLA (p = 0.088), QuickDASH (p = 0.135), VAS-pain (p = 0.062), or range of movement at the final follow-up. However, patient satisfaction was significantly lower in the fracture group (p = 0.002). The complication rate was 1.5% (one patient) versus 9.3% (six patients), and the revision rate was 1.5% (one patient) versus 7.8% (five patients) in the fracture and arthropathy groups, respectively. The ten-year arthroplasty survival was not significantly different (p = 0.221). Conclusion. RSA may be used not only for patients with irreparable rotator cuff deficiencies, but also for those with acute complex proximal humeral fractures. We found that RSA provided similar functional outcomes and a low revision rate for both indications at long-term. However, satisfaction is lower in patients with an acute fracture. Cite this article: Bone Joint J 2020;102-B(11):1555–1559


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 504 - 509
1 Apr 2013
Hutchison AM Pallister I Evans RM Bodger O Topliss CJ Williams P Beard DJ

We conducted a randomised controlled trial to determine whether active intense pulsed light (IPL) is an effective treatment for patients with chronic mid-body Achilles tendinopathy. A total of 47 patients were randomly assigned to three weekly therapeutic or placebo IPL treatments. The primary outcome measure was the Victorian Institute of Sport Assessment – Achilles (VISA-A) score. Secondary outcomes were a visual analogue scale for pain (VAS) and the Lower Extremity Functional Scale (LEFS). Outcomes were recorded at baseline, six weeks and 12 weeks following treatment. Ultrasound assessment of the thickness of the tendon and neovascularisation were also recorded before and after treatment. . There was no significant difference between the groups for any of the outcome scores or ultrasound measurements by 12 weeks, showing no measurable benefit from treatment with IPL in patients with Achilles tendinopathy. Cite this article: Bone Joint J 2013;95-B:504–9