Advertisement for orthosearch.org.uk
Results 21 - 40 of 120
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 1 | Pages 61 - 65
1 Jan 1993
Tiel-van Buul M van Beek E Broekhuizen A Bakker A Bos K van Royen E

Radiographs of the scaphoid after injury are difficult to interpret, and bone scintigraphy is widely used to increase the accuracy of diagnosis, though many fractures suspected on scintigraphy cannot be confirmed radiologically. We have reviewed the clinical consequences, after one year, of managing suspected scaphoid fractures according to the bone-scan results. We studied 160 patients, 35 of whom had initially positive radiographs and were treated in a cast for 12 weeks. The other 125 had bone scintigraphy and were managed according to the result. After a minimum of one year 119 patients were reviewed. Scintigraphically suspected scaphoid fracture could not be confirmed radiologically in 25%. There were no cases of nonunion. The long period of immobilisation in patients with positive radiographs or positive bone scans did not influence the frequency or severity of late symptoms compared with those with a normal bone scan


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 2 | Pages 218 - 224
1 Mar 1998
Compson JP

Various classifications of scaphoid fractures have been based on plain radiography, but there are difficulties in defining the actual fracture line without an appreciation of the three-dimensional anatomy. Radiological fracture lines were therefore mapped on transparent methylmethacrylate models of the bone. An analysis of 91 acute fractures showed that 11 were apparently incomplete. The other 80 showed three basic anatomical patterns: transverse through the waist, oblique in the plane of the dorsal sulcus, or of the proximal pole. There was some variation and comminution in these patterns, but no distal fractures of the body were seen. The interpretation of different radiological projections is discussed. The findings have implications for the management and the assessment of outcome


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 1 | Pages 98 - 101
1 Jan 1990
Dias J Thompson J Barton N Gregg P

Twenty observers reported independently on the presence or absence of a fracture of the scaphoid on 60 sets of radiographs; these included initial and 2- to 3-week views in patients in whom the outcome was known, normal scaphoids and random copies of these. Analysis of variance of the accuracy of observations revealed that the 2- to 3-week radiographs did not improve diagnostic ability and that this was independent of the experience or seniority of the observer. For normal radiographs, 20% of the observations reported a fracture. Reproducibility of opinion improved with experience but this did not help with accuracy. Radiographs without accurate clinical observation should not determine the management of the suspected scaphoid fracture


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 5 | Pages 829 - 831
1 Nov 1988
Kawai H Yamamoto K

Delayed union or non-union of the scaphoid was treated by a bone graft on a pronator quadratus pedicle in eight cases. This produced earlier union than the Russe procedure. The procedure is simple and is recommended for old un-united scaphoid fractures


Bone & Joint 360
Vol. 4, Issue 3 | Pages 35 - 36
1 Jun 2015
Clarke A


Bone & Joint Open
Vol. 3, Issue 11 | Pages 913 - 920
18 Nov 2022
Dean BJF Berridge A Berkowitz Y Little C Sheehan W Riley N Costa M Sellon E

Aims

The evidence demonstrating the superiority of early MRI has led to increased use of MRI in clinical pathways for acute wrist trauma. The aim of this study was to describe the radiological characteristics and the inter-observer reliability of a new MRI based classification system for scaphoid injuries in a consecutive series of patients.

Methods

We identified 80 consecutive patients with acute scaphoid injuries at one centre who had presented within four weeks of injury. The radiographs and MRI scans were assessed by four observers, two radiologists, and two hand surgeons, using both pre-existing classifications and a new MRI based classification tool, the Oxford Scaphoid MRI Assessment Rating Tool (OxSMART). The OxSMART was used to categorize scaphoid injuries into three grades: contusion (grade 1); unicortical fracture (grade 2); and complete bicortical fracture (grade 3).


Bone & Joint 360
Vol. 11, Issue 4 | Pages 21 - 25
1 Aug 2022


Bone & Joint 360
Vol. 11, Issue 1 | Pages 47 - 49
1 Feb 2022


Bone & Joint 360
Vol. 10, Issue 5 | Pages 24 - 28
1 Oct 2021


The Bone & Joint Journal
Vol. 101-B, Issue 8 | Pages 984 - 994
1 Aug 2019
Rua T Malhotra B Vijayanathan S Hunter L Peacock J Shearer J Goh V McCrone P Gidwani S

Aims

The aim of the Scaphoid Magnetic Resonance Imaging in Trauma (SMaRT) trial was to evaluate the clinical and cost implications of using immediate MRI in the acute management of patients with a suspected fracture of the scaphoid with negative radiographs.

Patients and Methods

Patients who presented to the emergency department (ED) with a suspected fracture of the scaphoid and negative radiographs were randomized to a control group, who did not undergo further imaging in the ED, or an intervention group, who had an MRI of the wrist as an additional test during the initial ED attendance. Most participants were male (52% control, 61% intervention), with a mean age of 36.2 years (18 to 73) in the control group and 38.2 years (20 to 71) in the intervention group. The primary outcome was total cost impact at three months post-recruitment. Secondary outcomes included total costs at six months, the assessment of clinical findings, diagnostic accuracy, and the participants’ self-reported level of satisfaction. Differences in cost were estimated using generalized linear models with gamma errors.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 5 | Pages 837 - 838
1 Sep 1993
Nathan S


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 5 | Pages 626 - 630
1 Jul 2004
Barton NJ


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 85 - 90
1 Jan 1999
Kulkarni RW Wollstein R Tayar R Citron N

We studied 45 patients with 46 fractures of the scaphoid who presented sequentially over a period of 21 months. MRI enabled us to relate the pattern of the fracture to the blood supply of the scaphoid. Serial MRI studies of the four main patterns showed that each followed a constant sequence during healing and failure to progress normally predicted nonunion.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 5 | Pages 933 - 933
1 Sep 1998
EHRENDORFER S


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 899 - 905
1 Jul 2008
Dias JJ Dhukaram V Abhinav A Bhowal B Wildin CJ

We report the outcome at a mean of 93 months (73 to 110) of 71 patients with an acute fracture of the scaphoid who were randomised to Herbert screw fixation (35) or below-elbow plaster cast immobilisation (36). These 71 patients represent the majority of a randomised series of 88 patients whose short-term outcome has previously been reported. Those patients available for later review were similar in age, gender and hand dominance.

There was no statistical difference in symptoms and disability as assessed by the mean Patient Evaluation Measure (p = 0.4), or mean Patient-Rated Wrist Evaluation (p = 0.9), the mean range of movement of the wrist (p = 0.4), mean grip strength (p = 0.8), or mean pinch strength (p = 0.4).

Radiographs were available from the final review for 59 patients. Osteoarthritic changes were seen in the scaphotrapezial and radioscaphoid joints in eight (13.5%) and six patients (10.2%), respectively. Three patients had asymptomatic lucency surrounding the screw. One non-operatively treated patient developed nonunion with avascular necrosis. In five patients who were treated non-operatively (16%) there was an abnormal scapholunate angle ( > 60°), but in four of these patients this finding was asymptomatic.

No medium-term difference in function or radiological outcome was identified between the two treatment groups.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 1 | Pages 181 - 181
1 Jan 1998
COONEY WP


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 6 | Pages 974 - 975
1 Nov 1993
Stothard J Kumar A


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 5 | Pages 828 - 832
1 Sep 1991
Clay N Dias J Costigan P Gregg P Barton N

Immobilisation of the thumb is widely believed to be important in the management of fractures of the carpal scaphoid. To assess the need for this, we randomly allocated 392 fresh fractures for treatment by either a forearm gauntlet (Colles') cast, leaving the thumb free, or by a conventional 'scaphoid' plaster incorporating the thumb as far as its interphalangeal joint. In the 292 fractures which were followed for six months, the incidence of nonunion was independent of the type of cast used.


Bone & Joint 360
Vol. 12, Issue 2 | Pages 24 - 28
1 Apr 2023

The April 2023 Wrist & Hand Roundup. 360. looks at: MRI-based classification for acute scaphoid injuries: the OxSMART; Deep learning for detection of scaphoid fractures?; Ulnar shortening osteotomy in adolescents; Cost-utility analysis of thumb carpometacarpal resection arthroplasty; Arthritis of the wrist following scaphoid fracture nonunion; Extensor hood injuries in elite boxers; Risk factors for reoperation after flexor tendon repair; Nonoperative versus operative treatment for displaced finger metacarpal shaft fractures


Bone & Joint Open
Vol. 2, Issue 6 | Pages 447 - 453
1 Jun 2021
Dean BJF Little C Riley ND Sellon E Sheehan W Burford J Hormbrey P Costa ML

Aims. To determine the role of early MRI in the management of suspected scaphoid fractures. Methods. A total of 337 consecutive patients presenting to an emergency department (ED) following wrist trauma over a 12-month period were prospectively included in this service evaluation project. MRI was not required in 62 patients with clear diagnoses, and 17 patients were not managed as per pathway, leaving a total of 258 patients with normal scaphoid series radiographs who were then referred directly from ED for an acute wrist MRI scan. Patient demographics, clinical details, outcomes, and complications were recorded at a minimum of a year following injury. Results. The median time from injury to ED presentation was one day and the median number of positive clinical signs was two out of three (snuffbox tenderness, tubercle tenderness, pain on telescoping). Of 258 patients referred for acute MRI, 208 scans were performed as 50 patients either did not tolerate (five patients) or did not attend their scan (45 patients). MRI scans demonstrated scaphoid fracture (13%), fracture of another bone (22%), scaphoid contusion (6%), other contusion/ligamentous injury (20%), or solely degenerative pathology (10%). Only 29% of scans showed no abnormality. Almost 50% of those undergoing MRI (100 patients) were discharged by ED with advice, with only one re-presentation. Of the 27 undisplaced occult scaphoid fractures, despite prompt cast immobilization, two experienced delayed union which was successfully treated with surgery. Conclusion. The use of MRI direct from ED enables prompt diagnosis and the early discharge of a large proportion of patients with normal radiographs following wrist trauma. Cite this article: Bone Jt Open 2021;2(6):447–453