Advertisement for orthosearch.org.uk
Results 21 - 40 of 623
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 31-B, Issue 2 | Pages 222 - 226
1 May 1949
Foley WB

1. An operation is described for ischio-femoral extra-articular arthrodesis of the hip joint by posterior open approach, based on the techniques of Trumble and Brittain. 2. The operation has the advantages of affording adequate exposure of the sciatic nerve trunk and permitting visual control of the alignment and penetration of the chisel and graft. 3. The operation has been performed successfully without serious shock or subsequent complications in eighteen cases, mostly of tuberculosis of the hip


Bone & Joint 360
Vol. 13, Issue 4 | Pages 13 - 16
2 Aug 2024

The August 2024 Hip & Pelvis Roundup. 360. looks at: Understanding perceived leg length discrepancy post-total hip arthroplasty: the role of pelvic obliquity; Influence of femoral stem design on revision rates in total hip arthroplasty; Outcomes of arthroscopic labral treatment of femoroacetabular impingement in adolescents; Characteristics and quality of online searches for direct anterior versus posterior approach for total hip arthroplasty; Rapid return to braking after anterior and posterior approach total hip arthroplasty; How much protection does a collar provide?; Timing matters: reducing infection risk in total hip arthroplasty with corticosteroid injection intervals; Identifying pain recovery patterns in total hip arthroplasty using PROMIS data


The Bone & Joint Journal
Vol. 103-B, Issue 9 | Pages 1479 - 1487
1 Sep 2021
Davis ET Pagkalos J Kopjar B

Aims. The aim of our study was to investigate the effect of asymmetric crosslinked polyethylene liner use on the risk of revision of cementless and hybrid total hip arthroplasties (THAs). Methods. We undertook a registry study combining the National Joint Registry dataset with polyethylene manufacturing characteristics as supplied by the manufacturers. The primary endpoint was revision for any reason. We performed further analyses on other reasons including instability, aseptic loosening, wear, and liner dissociation. The primary analytic approach was Cox proportional hazard regression. Results. A total of 213,146 THAs were included in the analysis. Overall, 2,997 revisions were recorded, 1,569 in THAs with a flat liner and 1,428 in THAs using an asymmetric liner. Flat liner THAs had a higher risk of revision for any reason than asymmetric liner THAs when implanted through a Hardinge/anterolateral approach (hazard ratio (HR) 1.169, 95% confidence interval (CI) 1.022 to 1.337) and through a posterior approach (HR 1.122, 95% CI 1.108 to 1.346). There was no increased risk of revision for aseptic loosening when asymmetric liners were used for any surgical approach. A separate analysis of the three most frequently used crosslinked polyethylene liners was in agreement with this finding. When analyzing THAs with flat liners only, THAs implanted through a Hardinge/anterolateral approach were associated with a reduced risk of revision for instability compared to posterior approach THAs (HR 0.561 (95% CI 0.446 to 0.706)). When analyzing THAs with an asymmetric liner, there was no significant difference in the risk of revision for instability between the two approaches (HR 0.838 (95% CI 0.633 to 1.110)). Conclusion. For THAs implanted through the posterior approach, the use of asymmetric liners reduces the risk of revision for instability and revision for any reason. In THAs implanted through a Hardinge/anterolateral approach, the use of an asymmetric liner was associated with a reduced risk of revision. The effect on revision for instability was less pronounced than in the posterior approach. Cite this article: Bone Joint J 2021;103-B(9):1479–1487


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 115 - 120
1 Mar 2024
Ricotti RG Flevas DA Sokrab R Vigdorchik JM Mayman DJ Jerabek SA Sculco TP Sculco PK

Aims. Periprosthetic femoral fracture (PPF) is a major complication following total hip arthroplasty (THA). Uncemented femoral components are widely preferred in primary THA, but are associated with higher PPF risk than cemented components. Collared components have reduced PPF rates following uncemented primary THA compared to collarless components, while maintaining similar prosthetic designs. The purpose of this study was to analyze PPF rate between collarless and collared component designs in a consecutive cohort of posterior approach THAs performed by two high-volume surgeons. Methods. This retrospective series included 1,888 uncemented primary THAs using the posterior approach performed by two surgeons (PKS, JMV) from January 2016 to December 2022. Both surgeons switched from collarless to collared components in mid-2020, which was the only change in surgical practice. Data related to component design, PPF rate, and requirement for revision surgery were collected. A total of 1,123 patients (59.5%) received a collarless femoral component and 765 (40.5%) received a collared component. PPFs were identified using medical records and radiological imaging. Fracture rates between collared and collarless components were analyzed. Power analysis confirmed 80% power of the sample to detect a significant difference in PPF rates, and a Fisher’s exact test was performed to determine an association between collared and collarless component use on PPF rates. Results. Overall, 17 PPFs occurred (0.9%). There were 16 fractures out of 1,123 collarless femoral components (1.42%) and one fracture out of 765 collared components (0.13%; p = 0.002). The majority of fractures (n = 14; 82.4%) occurred within 90 days of primary THA. There were ten reoperations for PPF with collarless components (0.89%) and one reoperation with a collared component (0.13%; p = 0.034). Conclusion. Collared femoral components were associated with significant decreases in PPF rate and reoperation rate for PPF compared to collarless components in uncemented primary THA. Future studies should investigate whether new-generation collared components reduce PPF rates with longer-term follow-up. Cite this article: Bone Joint J 2024;106-B(3 Supple A):115–120


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1662 - 1669
1 Dec 2020
Pollmann CT Gjertsen J Dale H Straume-Næsheim TM Dybvik E Hallan G

Aims. To compare the functional outcome, health-related quality of life (HRQoL), and satisfaction of patients who underwent primary total hip arthroplasty (THA) and a single debridement, antibiotics and implant retention (DAIR) procedure for deep infection, using either the transgluteal or the posterior surgical approach for both procedures. Methods. The study was registered at clinicaltrials.gov (ID: NCT03161990) on 15 May 2017. Patients treated with a single DAIR procedure for deep infection through the same operative approach as their primary THA (either the transgluteal or the posterior approach) were identified in the Norwegian Arthroplasty Register and given a questionnaire. Median follow-up after DAIR by questionnaire was 5.5 years in the transgluteal group (n = 87) and 2.5 years in the posterior approach group (n = 102). Results. Patients in the posterior approach group were less likely to limp after the DAIR procedure (17% vs 36% limped all the time; p = 0.005), had a higher mean Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) function score (80 vs 71; p = 0.013), and were more likely to achieve a patient acceptable symptom state for the WOMAC function score (76% vs 55%; p = 0.002). In a multivariable analysis, the point estimate for the increase in WOMAC function score using the posterior approach was 10.2 (95% CI 3.1 to 17.2; p = 0.005), which is above the minimal clinically important improvement. The patients in the posterior approach group also reported better mean HRQoL scores and were more likely to be satisfied with their hip arthroplasty (77% vs 55%; p = 0.001). Conclusion. In patients treated with a single, successful DAIR procedure for deep infection of a primary THA, the use of the posterior approach in both primary surgery and DAIR was associated with less limping, better functional outcome, better HRQoL, and higher patient satisfaction compared with cases where both were performed using the transgluteal approach. The observed differences in functional outcome and patient satisfaction were clinically relevant. Cite this article: Bone Joint J 2020;102-B(12):1662–1669


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 734 - 738
1 Apr 2021
Varshneya K Jokhai R Medress ZA Stienen MN Ho A Fatemi P Ratliff JK Veeravagu A

Aims. The aim of this study was to identify the risk factors for adverse events following the surgical correction of cervical spinal deformities in adults. Methods. We identified adult patients who underwent corrective cervical spinal surgery between 1 January 2007 and 31 December 2015 from the MarketScan database. The baseline comorbidities and characteristics of the operation were recorded. Adverse events were defined as the development of a complication, an unanticipated deleterious postoperative event, or further surgery. Patients aged < 18 years and those with a previous history of tumour or trauma were excluded from the study. Results. A total of 13,549 adults in the database underwent primary corrective surgery for a cervical spinal deformity during the study period. A total of 3,785 (27.9%) had a complication within 90 days of the procedure, and 3,893 (28.7%) required further surgery within two years. In multivariate analysis, male sex (odds ratio (OR) 0.90 (95% confidence interval (CI) 0.8 to 0.9); p = 0.019) and a posterior approach (compared with a combined surgical approach, OR 0.66 (95% CI 0.5 to 0.8); p < 0.001) significantly decreased the risk of complications. Osteoporosis (OR 1.41 (95% CI 1.3 to 1.6); p < 0.001), dyspnoea (OR 1.48 (95% CI 1.3 to 1.6); p < 0.001), cerebrovascular accident (OR 1.81 (95% CI 1.6 to 2.0); p < 0.001), a posterior approach (compared with an anterior approach, OR 1.23 (95% CI 1.1 to 1.4); p < 0.001), and the use of bone morphogenic protein (BMP) (OR 1.22 (95% CI 1.1 to 1.4); p = 0.003) significantly increased the risks of 90-day complications. In multivariate regression analysis, preoperative dyspnoea (OR 1.50 (95% CI 1.3 to 1.7); p < 0.001), a posterior approach (compared with an anterior approach, OR 2.80 (95% CI 2.4 to 3.2; p < 0.001), and postoperative dysphagia (OR 2.50 (95% CI 1.8 to 3.4); p < 0.001) were associated with a significantly increased risk of further surgery two years postoperatively. A posterior approach (compared with a combined approach, OR 0.32 (95% CI 0.3 to 0.4); p < 0.001), the use of BMP (OR 0.48 (95% CI 0.4 to 0.5); p < 0.001) were associated with a significantly decreased risk of further surgery at this time. Conclusion. The surgical approach and intraoperative use of BMP strongly influence the risk of further surgery, whereas the comorbidity burden and the characteristics of the operation influence the rates of early complications in adult patients undergoing corrective cervical spinal surgery. These data may aid surgeons in patient selection and surgical planning. Cite this article: Bone Joint J 2021;103-B(4):734–738


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 46 - 52
1 Jul 2021
McGoldrick NP Fischman D Nicol GM Kreviazuk C Grammatopoulos G Beaulé PE

Aims. The aim of this study was to radiologically evaluate the quality of cement mantle and alignment achieved with a polished tapered cemented femoral stem inserted through the anterior approach and compared with the posterior approach. Methods. A comparative retrospective study of 115 consecutive hybrid total hip arthroplasties or cemented hemiarthroplasties in 110 patients, performed through anterior (n = 58) or posterior approach (n = 57) using a collarless polished taper-slip femoral stem, was conducted. Cement mantle quality and thickness were assessed in both planes. Radiological outcomes were compared between groups. Results. No significant differences were identified between groups in Barrack grade on the anteroposterior (AP) (p = 0.640) or lateral views (p = 0.306), or for alignment on the AP (p = 0.603) or lateral views (p = 0.254). An adequate cement mantle (Barrack A or B) was achieved in 77.6% (anterior group, n = 45) and in 86% (posterior group, n = 49), respectively. Multivariate analysis revealed factors associated with unsatisfactory cement mantle (Barrack C or D) included higher BMI, left side, and Dorr Type C morphology. A mean cement mantle thickness of ≥ 2 mm was achieved in all Gruen zones for both approaches. The mean cement mantle was thicker in zone 7 (p < 0.001) and thinner in zone 9 for the anterior approach (p = 0.032). Incidence of cement mantle defects between groups was similar (6.9% (n = 4) vs 8.8% (n = 5), respectively; p = 0.489). Conclusion. An adequate cement mantle and good alignment can be achieved using a collarless polished tapered femoral component inserted through the anterior approach. Cite this article: Bone Joint J 2021;103-B(7 Supple B):46–52


Bone & Joint Open
Vol. 2, Issue 6 | Pages 365 - 370
1 Jun 2021
Kolodychuk N Su E Alexiades MM Ren R Ojard C Waddell BS

Aims. Traditionally, acetabular component insertion during total hip arthroplasty (THA) is visually assisted in the posterior approach and fluoroscopically assisted in the anterior approach. The present study examined the accuracy of a new surgeon during anterior (NSA) and posterior (NSP) THA using robotic arm-assisted technology compared to two experienced surgeons using traditional methods. Methods. Prospectively collected data was reviewed for 120 patients at two institutions. Data were collected on the first 30 anterior approach and the first 30 posterior approach surgeries performed by a newly graduated arthroplasty surgeon (all using robotic arm-assisted technology) and was compared to standard THA by an experienced anterior (SSA) and posterior surgeon (SSP). Acetabular component inclination, version, and leg length were calculated postoperatively and differences calculated based on postoperative film measurement. Results. Demographic data were similar between groups with the exception of BMI being lower in the NSA group (27.98 vs 25.2; p = 0.005). Operating time and total time in operating room (TTOR) was lower in the SSA (p < 0.001) and TTOR was higher in the NSP group (p = 0.014). Planned versus postoperative leg length discrepancy were similar among both anterior and posterior surgeries (p > 0.104). Planned versus postoperative abduction and anteversion were similar among the NSA and SSA (p > 0.425), whereas planned versus postoperative abduction and anteversion were lower in the NSP (p < 0.001). Outliers > 10 mm from planned leg length were present in one case of the SSP and NSP, with none in the anterior groups. There were no outliers > 10° in anterior or posterior for abduction in all surgeons. The SSP had six outliers > 10° in anteversion while the NSP had none (p = 0.004); the SSA had no outliers for anteversion while the NSA had one (p = 0.500). Conclusion. Robotic arm-assisted technology allowed a newly trained surgeon to produce similarly accurate results and outcomes as experienced surgeons in anterior and posterior hip arthroplasty. Cite this article: Bone Jt Open 2021;2(6):365–370


Bone & Joint Research
Vol. 13, Issue 4 | Pages 193 - 200
23 Apr 2024
Reynolds A Doyle R Boughton O Cobb J Muirhead-Allwood S Jeffers J

Aims. Manual impaction, with a mallet and introducer, remains the standard method of installing cementless acetabular cups during total hip arthroplasty (THA). This study aims to quantify the accuracy and precision of manual impaction strikes during the seating of an acetabular component. This understanding aims to help improve impaction surgical techniques and inform the development of future technologies. Methods. Posterior approach THAs were carried out on three cadavers by an expert orthopaedic surgeon. An instrumented mallet and introducer were used to insert cementless acetabular cups. The motion of the mallet, relative to the introducer, was analyzed for a total of 110 strikes split into low-, medium-, and high-effort strikes. Three parameters were extracted from these data: strike vector, strike offset, and mallet face alignment. Results. The force vector of the mallet strike, relative to the introducer axis, was misaligned by an average of 18.1°, resulting in an average wasted strike energy of 6.1%. Furthermore, the mean strike offset was 19.8 mm from the centre of the introducer axis and the mallet face, relative to the introducer strike face, was misaligned by a mean angle of 15.2° from the introducer strike face. Conclusion. The direction of the impact vector in manual impaction lacks both accuracy and precision. There is an opportunity to improve this through more advanced impaction instruments or surgical training. Cite this article: Bone Joint Res 2024;13(4):193–200


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 104 - 109
1 Mar 2024
Sugano N Maeda Y Fuji H Tamura K Nakamura N Takashima K Uemura K Hamada H

Aims. Femoral component anteversion is an important factor in the success of total hip arthroplasty (THA). This retrospective study aimed to investigate the accuracy of femoral component anteversion with the Mako THA system and software using the Exeter cemented femoral component, compared to the Accolade II cementless femoral component. Methods. We reviewed the data of 30 hips from 24 patients who underwent THA using the posterior approach with Exeter femoral components, and 30 hips from 24 patients with Accolade II components. Both groups did not differ significantly in age, sex, BMI, bone quality, or disease. Two weeks postoperatively, CT images were obtained to measure acetabular and femoral component anteversion. Results. The mean difference in femoral component anteversion between intraoperative and postoperative CT measurements (system accuracy of component anteversion) was 0.8° (SD 1.8°) in the Exeter group and 2.1° (SD 2.3°) in the Accolade II group, respectively (p = 0.020). The mean difference in anteversion between the plan and the postoperative CT measurements (clinical accuracy of femoral component anteversion) was 1.2° (SD 3.6°) in the Exeter group, and 4.2° (SD 3.9°) in the Accolade II group (p = 0.003). No significant differences were found in acetabular component inclination and anteversion; however, the clinical accuracy of combined anteversion was significantly better in the Exeter group (0.6° (SD 3.9°)) than the Accolade II group (3.6° (SD 4.1°)). Conclusion. The Mako THA system and software helps surgeons control the femoral component anteversion to achieve the target angle of insertion. The Exeter femoral component, inserted using Mako THA system, showed greater precision for femoral component and combined component anteversion than the Accolade II component. Cite this article: Bone Joint J 2024;106-B(3 Supple A):104–109


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 646 - 651
1 Jun 2019
Aggarwal VK Elbuluk A Dundon J Herrero C Hernandez C Vigdorchik JM Schwarzkopf R Iorio R Long WJ

Aims. A variety of surgical approaches are used for total hip arthroplasty (THA), all with reported advantages and disadvantages. A number of common complications can occur following THA regardless of the approach used. The purpose of this study was to compare five commonly used surgical approaches with respect to the incidence of surgery-related complications. Patients and Methods. The electronic medical records of all patients who underwent primary elective THA at a single large-volume arthroplasty centre, between 2011 and 2016, with at least two years of follow-up, were reviewed. After exclusion, 3574 consecutive patients were included in the study. There were 1571 men (44.0%) and 2003 women (56.0%). Their mean age and body mass index (BMI) was 63.0 years (. sd. 11.8) and 29.1 kg/m. 2. (. sd. 6.1), respectively. Data gathered included the age of the patient, BMI, the American Society of Anesthesiologists (ASA) score, estimated blood loss (EBL), length of stay (LOS), operating time, the presence of intra- or postoperative complications, type of complication, and the surgical approach. The approaches used during the study were posterior, anterior, direct lateral, anterolateral, and the northern approach. The complications that were recorded included prolonged wound drainage without infection, superficial infection, deep infection, dislocation, aseptic loosening, and periprosthetic fracture. Finally, the need for re-operation was recorded. Means were compared using analysis of variance (ANOVA) and Student’s t-tests where appropriate and proportions were compared using the chi-squared test. Results. A total of 248 patients had 263 complications related to the surgery, with an incidence of 6.94%. The anterior approach had the highest incidence of complications (8.5% (113/1329)) and the posterior approach had the lowest, at 5.85% (97/1657; p = 0.006). Most complications were due to deep infection (22.8%), periprosthetic fracture (22.4%), and prolonged wound drainage (21.3%). The rate of dislocation was 0.84% (14/1657) with the posterior approach and 1.28% (17/1329) with the anterior approach (p = 0.32). Conclusion. Overall, THA has a relatively low complication rate. However, the surgical approach plays a role in the incidence of complications. We found that the posterior approach had a significantly lower overall complication rate compared with the anterior approach, with an equal dislocation rate. Periprosthetic fracture and surgical site infection contributed most to the early complication rates. Cite this article: Bone Joint J 2019;101-B:646–651


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 506 - 512
1 Apr 2020
de Bodman C Ansorge A Tabard A Amirghasemi N Dayer R

Aims. The direct posterior approach with subperiosteal dissection of the paraspinal muscles from the vertebrae is considered to be the standard approach for the surgical treatment of adolescent idiopathic scoliosis (AIS). We investigated whether or not a minimally-invasive surgery (MIS) technique could offer improved results. Methods. Consecutive AIS patients treated with an MIS technique at two tertiary centres from June 2013 to March 2016 were retrospectively included. Preoperative patient deformity characteristics, perioperative parameters, power of deformity correction, and complications were studied. A total of 93 patients were included. The outcome of the first 25 patients and the latter 68 were compared as part of our safety analysis to examine the effect of the learning curve. Results. In the first 25 cases, with a mean follow-up of 5.6 years (standard deviation (SD) 0.4), the mean preoperative major Cobb angle was 57.6° (SD 9.8°) and significantly corrected to mean 15.4° (SD 5.6°, 73% curve correction). The mean preoperative T5-T12 was 26.2 (SD 12.8) and significantly increased to mean 32.9 (SD 8.3). Both frontal and sagittal plane correction was conserved two years after surgery. The rate of perioperative complications was 12% and three further complications occurred (three deep delayed infection). In the latter cases, 68 patients were included with a mean follow-up time of three years (SD 0.6). The mean preoperative major Cobb angle was 58.4° (SD 9.2°) and significantly corrected to mean 20.4° (SD 7.3°).The mean preoperative T5-T12 kyphosis was 26.6° (SD 12.8°) and was significantly increased to mean 31.4° (SD 8.3°). Both frontal and sagittal correction was conserved two years after surgery. The perioperative (30 day) complication rate was 1.4%. Two (2.9%) additional complications occurred in two patients. Conclusion. MIS for AIS is associated with a significant correction of spine deformity in the frontal and sagittal planes, together with low estimated blood loss and short length of stay. The perioperative complication rate seems to be lower compared with the standard open technique based on the literature data. The longer-term safety of MIS for AIS needs to be documented with a larger cohort and compared with the standard posterior approach. Cite this article: Bone Joint J 2020;102-B(4):506–512


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 155 - 161
1 Feb 2020
McMahon SE Diamond OJ Cusick LA

Aims. Complex displaced osteoporotic acetabular fractures in the elderly are associated with high levels of morbidity and mortality. Surgical options include either open reduction and internal fixation alone, or combined with total hip arthroplasty (THA). There remains a cohort of severely comorbid patients who are deemed unfit for extensive surgical reconstruction and are treated conservatively. We describe the results of a coned hemipelvis reconstruction and THA inserted via a posterior approach to the hip as the primary treatment for this severely high-risk cohort. Methods. We have prospectively monitored a series of 22 cases (21 patients) with a mean follow-up of 32 months (13 to 59). Results. The mean patient age was 79 years (67 to 87), and the mean ASA score was 3.3 (3 to 5). Three patients had high-energy injuries and 18 had low-energy injuries. All cases were associated fractures (Letournel classification: anterior column posterior hemitransverse, n = 13; associated both column, n = 6; transverse posterior wall, n = 3) with medialization of the femoral head. Mean operative time was 93 minutes (61 to 135). There have been no revisions to date. Of the 21 patients, 20 were full weight-bearing on day 1 postoperatively. Mean length of hospital stay was 12 days (5 to 27). Preoperative mobility status was maintained in 13 patients. At one year, mean Merle d’Aubigné score was 13.1 (10 to 18), mean Oxford Hip Score was 38.5 (24 to 44), mean EuroQol five-dimension five-level (EQ-5D-5L) health score was 68 (30 to 92), and mean EQ-5D-5L index score was 0.68 (0.335 to 0.837); data from 14 patients. Mortality was 9.5% (2/21) at one year. There have been no thromboembolic events, deep infections, or revisions. Conclusion. The coned hemipelvis reconstruction bypasses the fracture, creating an immediately stable construct that allows immediate full weight-bearing. The posterior approach minimizes the operative time and physiological insult in this vulnerable patient population. Early results suggest this to be a safe addition to current surgical options, targeted at the most medically frail elderly patient with a complex displaced acetabular fracture. Cite this article: Bone Joint J 2020;102-B(2):155–161


Bone & Joint 360
Vol. 12, Issue 3 | Pages 27 - 30
1 Jun 2023

The June 2023 Shoulder & Elbow Roundup. 360. looks at: Proximal humerus fractures: what does the literature say now?; Infection risk of steroid injections and subsequent reverse shoulder arthroplasty; Surgical versus non-surgical management of humeral shaft fractures; Core outcome set needed for elbow arthroplasty; Minimally invasive approaches to locating radial nerve in the posterior humeral approach; Predictors of bone loss in anterior glenohumeral instability; Does the addition of motor control or strengthening exercises improve rotator cuff-related shoulder pain?; Terminology and diagnostic criteria used in patients with subacromial pain syndrome


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 9 - 16
1 Jul 2021
Hadden WJ Ibrahim M Taha M Ure K Liu Y Paish ADM Holdsworth DW Abdelbary H

Aims. The aims of this study were to develop an in vivo model of periprosthetic joint infection (PJI) in cemented hip hemiarthroplasty, and to monitor infection and biofilm formation in real-time. Methods. Sprague-Dawley rats underwent cemented hip hemiarthroplasty via the posterior approach with pre- and postoperative gait assessments. Infection with Staphylococcus aureus Xen36 was monitored with in vivo photoluminescent imaging in real-time. Pre- and postoperative gait analyses were performed and compared. Postmortem micro (m) CT was used to assess implant integration; field emission scanning electron microscopy (FE-SEM) was used to assess biofilm formation on prosthetic surfaces. Results. All animals tolerated surgery well, with preservation of gait mechanics and weightbearing in control individuals. Postoperative in vivo imaging demonstrated predictable evolution of infection with logarithmic signal decay coinciding with abscess formation. Postmortem mCT qualitative volumetric analysis showed high contact area and both cement-bone and cement-implant interdigitation. FE-SEM revealed biofilm formation on the prosthetic head. Conclusion. This study demonstrates the utility of a new, high-fidelity model of in vivo PJI using cemented hip hemiarthroplasty in rats. Inoculation with bioluminescent bacteria allows for non-invasive, real-time monitoring of infection. Cite this article: Bone Joint J 2021;103-B(7 Supple B):9–16


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 207 - 212
1 Feb 2019
Clavé A Gérard R Lacroix J Baynat C Danguy des Déserts M Gatineau F Mottier D

Aims. Cementless primary total hip arthroplasty (THA) is associated with risks of bleeding and thromboembolism. Anticoagulants are effective as venous thromboprophylaxis, but with an increased risk of bleeding. Tranexamic acid (TXA) is an efficient antifibrinolytic agent, but the mode and timing of its administration remain controversial. This study aimed to determine whether two intravenous (IV) TXA regimens (a three-hour two-dose (short-TXA) and 11-hour four-dose (long-TXA)) were more effective than placebo in reducing perioperative real blood loss (RBL, between baseline and day 3 postoperatively) in patients undergoing THA who receive rivaroxaban as thromboprophylaxis. The secondary aim was to assess the non-inferiority of the reduction of blood loss of the short protocol versus the long protocol. Patients and Methods. A multicentre, prospective, randomized, double-blind, placebo-controlled trial was undertaken involving 229 patients undergoing primary cementless THA using a posterior approach, whose extended rivaroxaban thromboprophylaxis started on the day of surgery. There were 98 male and 131 female patients, with a mean age of 65.5 years (32 to 91). The primary outcome, perioperative RBL, was evaluated at 72 hours postoperatively. The efficacy of short- and long-TXA protocols in the reduction of perioperative RBL was compared with a placebo group. Results. TXA significantly reduced perioperative blood loss compared with placebo (p < 0.001); the mean differences were 525.3 ml (short-TXA vs placebo) and 550.1 ml (long-TXA vs placebo). No venous or arterial thromboembolic complications were reported. The upper boundary of the 95% confidence interval, when comparing short and long protocols, was below the pre-specified margin of non-inferiority (p = 0.027). Conclusion. In patients undergoing primary cementless THA, using a posterior approach, who are treated with rivaroxaban for thromboembolic prophylaxis, short- and long-TXA IV protocols are significantly more effective than placebo in reducing perioperative RBL, without any thromboembolic complications. Non-inferiority of a short- versus a long-TXA protocol in reducing perioperative RBL was supported in a secondary analysis


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 78 - 83
1 Jul 2021
Roedel GG Kildow BJ Sveom DS Garvin KL

Aims. Highly cross-linked polyethylene (HXLPE) has greatly improved the durability of total hip arthroplasty (THA) in young patients because of its improved wear characteristics. Few studies have followed this population into the second decade, and therefore the purpose of this investigation was to evaluate the clinical outcome for THA patients 50 years of age and younger at a minimum of 15 years postoperatively. The second purpose was to evaluate the radiological findings secondary to wear or mechanical failure of the implant. Methods. Between October 1999 and December 2005, 105 THAs were performed in 95 patients (53 female, 42 male) aged 50 years and younger (mean 42 years (20 to 50)). There were 87 patients (96 hips) that were followed for a minimum of 15 years (mean 17.3 years (15 to 21)) for analysis. Posterior approach was used with cementless fixation with a median head size of 28 mm. HXLPE was the acetabular bearing for all hips. Radiographs were evaluated for polyethylene wear, radiolucent lines, and osteolysis. Results. Clinical outcomes showed significant improvement of mean Harris Hip Scores from 52.8 (SD 13.5) preoperatively to 94.8 (SD 7.6) postoperatively. One hip was revised for recurrent instability, and there were no infections. No hips were revised for mechanical loosening or osteolysis. Mean polyethylene linear wear was 0.04 mm/year and volumetric wear was 6.22 mm. 3. /year, with no significant differences between head size or material. Osteolysis was not present in any of the hips. Conclusion. The use of HXLPE in THA for patients aged 50 years and younger has performed exceptionally well without evidence of significant wear causing mechanical loosening or necessitating revision. The radiolucent lines of the acetabular component must be followed to determine the prognostic significance. This investigation represents the longest clinical follow-up of a large, consecutive cohort of patients aged 50 years or younger with THA using HXLPE. This long-term analysis found negligible polyethylene wear, no incidence of aseptic loosening, and excellent clinical outcomes at and beyond 15 years of follow-up. Cite this article: Bone Joint J 2021;103-B(7 Supple B):78–83


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 976 - 983
3 May 2021
Demura S Kato S Shinmura K Yokogawa N Shimizu T Handa M Annen R Kobayashi M Yamada Y Murakami H Kawahara N Tomita K Tsuchiya H

Aims. To evaluate the perioperative complications associated with total en bloc spondylectomy (TES) in patients with spinal tumours, based on the extent and level of tumour resection. Methods. In total, 307 patients who underwent TES in a single centre were reviewed retrospectively. There were 164 male and 143 female patients with a mean age at the time of surgery of 52.9 years (SD 13.3). A total of 225 patients were operated on for spinal metastases, 34 for a malignant primary tumour, 41 for an aggressive benign tumour, and seven with a primary of unknown origin. The main lesion was located in the thoracic spine in 213, and in the lumbar spine in 94 patients. There were 97 patients who underwent TES for more than two consecutive vertebrae. Results. Major and minor perioperative complications were observed in 122 (39.7%) and 84 (27.4%) patients respectively. The breakdown of complications was as follows: bleeding more than 2,000 ml in 60 (19.5%) patients, hardware failure in 82 (26.7%), neurological in 46 (15.0%), surgical site infection in 23 (7.5%), wound dehiscence in 16 (5.2%), cerebrospinal fluid leakage in 45 (14.7%), respiratory in 52 (16.9%), cardiovascular in 11 (3.6%), digestive in 19 (6.2%)/ The mortality within two months of surgery was four (1.3%). The total number of complications per operation were 1.01 (SD 1.0) in the single vertebral resection group and 1.56 (SD 1.2) in the group with more than two vertebral resections. Cardiovascular and respiratory complications, along with hardware failure were statistically higher in the group who had more than two vertebrae resected. Also, in this group the amount of bleeding in patients with a lumbar lesion or respiratory complication in patients with a thoracic lesion, were statistically higher. Multivariate analysis showed that using a combined anterior and posterior approach, when more than two vertebral resections were significant independent factors. Conclusion. The characteristics of perioperative complications after TES were different depending on the extent and level of the tumour resection. In addition to preoperative clinical and pathological factors, it is therefore important to consider these factors in patients who undergo en bloc resection for spinal tumours. Cite this article: Bone Joint J 2021;103-B(5):976–983


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 754 - 760
1 Jun 2016
Malek IA Royce G Bhatti SU Whittaker JP Phillips SP Wilson IRB Wootton JR Starks I

Aims. We assessed the difference in hospital based and early clinical outcomes between the direct anterior approach and the posterior approach in patients who undergo total hip arthroplasty (THA). Patients and Methods. The outcome was assessed in 448 (203 males, 245 females) consecutive patients undergoing unilateral primary THA after the implementation of an ‘Enhanced Recovery’ pathway. In all, 265 patients (mean age: 71 years (49 to 89); 117 males and 148 females) had surgery using the direct anterior approach (DAA) and 183 patients (mean age: 70 years (26 to 100); 86 males and 97 females) using a posterior approach. The groups were compared for age, gender, American Society of Anesthesiologists grade, body mass index, the side of the operation, pre-operative Oxford Hip Score (OHS) and attendance at ‘Joint school’. Mean follow-up was 18.1 months (one to 50). Results. There was no significant difference in mean length of stay (p = 0.07), pain scores on the day of surgery, the first, second and third post-operative days (p = 0.36, 0.23, 0.25 and 0.59, respectively), the day of mobilisation (p = 0.12), the mean OHS at six and 24 months (p = 0.08, and 0.29, respectively), the incidence of infection (p = 1.0), dislocation (p = 1.0), re-operation (p = 0.21) or 28 days’ re-admission (p = 0.06). Significantly more patients in the DAA group achieved a planned discharge target of three days post-operatively (68% vs 56%, p = 0.007). The rate of periprosthetic femoral fractures was significantly higher in the DAA group (p = 0.04). Conclusion. We conclude that there is no difference in clinical outcomes between the DAA and the posterior approach in patients undergoing THA when an ‘Enhanced Recovery’ pathway is used. However, a significantly higher rate of periprosthetic femoral fractures remains a concern with the DAA, even in experienced hands. Take home message: Our results show that the DAA for THA is not superior to posterior approach when ‘Enhanced Recovery’ pathway is used. Cite this article: Bone Joint J 2016;98-B:754–60


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 732 - 740
1 Jun 2017
Meermans G Konan S Das R Volpin A Haddad FS

Aims. The most effective surgical approach for total hip arthroplasty (THA) remains controversial. The direct anterior approach may be associated with a reduced risk of dislocation, faster recovery, reduced pain and fewer surgical complications. This systematic review aims to evaluate the current evidence for the use of this approach in THA. Materials and Methods. Following the Cochrane collaboration, an extensive literature search of PubMed, Medline, Embase and OvidSP was conducted. Randomised controlled trials, comparative studies, and cohort studies were included. Outcomes included the length of the incision, blood loss, operating time, length of stay, complications, and gait analysis. Results. A total of 42 studies met the inclusion criteria. Most were of medium to low quality. There was no difference between the direct anterior, anterolateral or posterior approaches with regards to length of stay and gait analysis. Papers comparing the length of the incision found similar lengths compared with the lateral approach, and conflicting results when comparing the direct anterior and posterior approaches. . Most studies found the mean operating time to be significantly longer when the direct anterior approach was used, with a steep learning curve reported by many. Many authors used validated scores including the Harris hip score, and the Western Ontario and McMaster Universities Arthritis Index. These mean scores were better following the use of the direct anterior approach for the first six weeks post-operatively. Subsequently there was no difference between these scores and those for the posterior approach. Conclusion . There is little evidence for improved kinematics or better long-term outcomes following the use of the direct anterior approach for THA. There is a steep learning curve with similar rates of complications, length of stay and outcomes. . Well-designed, multi-centre, prospective randomised controlled trials are required to provide evidence as to whether the direct anterior approach is better than the lateral or posterior approaches when undertaking THA. Cite this article: Bone JointJ 2017;99-B:732–40