Chronic low back pain due to degenerative disc disease is sometimes treated with fusion. We compared the outcome of three different fusion techniques in the Swedish Spine Register: noninstrumented posterolateral fusion (PLF), instrumented posterolateral fusion (IPLF), and interbody fusion (IBF). A total of 2874 patients who were operated on at one or two lumbar levels were followed for a mean of 9.2 years (3.6 to 19.1) for any additional lumbar spine surgery. Patient-reported outcome data were available preoperatively (n = 2874) and at one year (n = 2274), two years (n = 1958), and a mean of 6.9 years (n = 1518) postoperatively and consisted of global assessment and visual analogue scales of leg and back pain, Oswestry Disability Index, EuroQol five-dimensional index, 36-Item Short-Form Health Survey, and satisfaction with treatment. Statistical analyses were performed with competing-risks proportional hazards regression or analysis of covariance, adjusted for baseline variables.Aims
Patients and Methods
The aim of this paper is to describe the impact of COVID-19 on spine surgery services in a district general hospital in England in order to understand the spinal service provisions that may be required during a pandemic. A prospective cohort study was undertaken between 17 March 2020 and 30 April 2020 and compared with retrospective data from same time period in 2019. We compared the number of patients requiring acute hospital admission or orthopaedic referrals and indications of referrals from our admission sheets and obtained operative data from our theatre software.Aims
Methods
Aims. To determine the effectiveness of prone traction radiographs in predicting postoperative slip distance, slip angle, changes in disc height, and lordosis after surgery for degenerative spondylolisthesis of the lumbar spine. Methods. A total of 63 consecutive patients with a degenerative spondylolisthesis and preoperative prone traction radiographs obtained since 2010 were studied. Slip distance, slip angle, disc height, segmental lordosis, and global lordosis (L1 to S1) were measured on preoperative lateral standing radiographs, flexion-extension lateral radiographs, prone traction lateral radiographs, and postoperative lateral standing radiographs. Patients were divided into two groups: posterolateral fusion or posterolateral fusion with interbody fusion. Results. The mean changes in segmental lordosis and global lordosis were 7.1° (SD 6.7°) and 2.9° (SD 9.9°) respectively for the interbody fusion group, and 0.8° (SD 5.1°) and -0.4° (SD 10.1°) respectively for the posterolateral fusion-only group. Segmental lordosis (ρ = 0.794, p < 0.001) corrected by interbody fusion correlated best with prone traction radiographs. Global lumbar lordosis (ρ = 0.788, p < 0.001) correlated best with the interbody fusion group and preoperative lateral standing radiographs. The least difference in slip distance (-0.3 mm (SD 1.7 mm), p < 0.001), slip angle (0.9° (SD 5.2°), p < 0.001), and disc height (0.02 mm (SD 2.4 mm), p < 0.001) was seen between prone traction and postoperative radiographs. Regression analyses suggested that prone traction parameters best predicted correction of slip distance (Corrected Akaike’s Information Criterion (AICc) = 37.336) and disc height (AICc = 58.096), while correction of slip angle (AICc = 26.453) was best predicted by extension radiographs. Receiver operating characteristic (ROC) cut-off showed, with 68.3% sensitivity and 64.5% specificity, that to achieve a 3.0° increase in segmental lordotic angle, patients with a prone traction disc height of 8.5 mm needed an interbody fusion. Conclusion. Prone traction radiographs best predict the slip distance and disc height correction achieved by
Fracture of a pedicle is a rare complication of spinal instrumentation using pedicular screws, but it can lead to instability and pain and may necessitate extension of the fusion. Osteosynthesis of the fractured pedicle by cerclage-wire fixation and augmentation of the screw fixation by vertebroplasty or temporary elongation of the fixation, allows stabilisation without sacrifice of the adjacent healthy segment. We describe three patients who developed a fracture of the pedicle in the most caudal instrumented vertebra early after lumbar spinal fusion. During revision surgery the pedicles were reduced and secured by a soft cerclage wire bilaterally. Fusion was obtained at the site of the primary instrumentation and healing of the pedicles was achieved. Cerclage wiring of the fractured pedicle seems to be safe and avoids permanent extension of the fusion without the sacrifice of an otherwise healthy segment.
We performed a systematic review of the literature to determine the safety and efficacy of bone morphogenetic protein (BMP) compared with bone graft when used specifically for revision spinal fusion surgery secondary to pseudarthrosis. The MEDLINE, EMBASE and Cochrane Library databases were searched using defined search terms. The primary outcome measure was spinal fusion, assessed as success or failure in accordance with radiograph, MRI or CT scan review at 24-month follow-up. The secondary outcome measure was time to fusion.Objectives
Methods
The aim of this study was to investigate the clinical and radiographic
outcomes of microendoscopic laminotomy in patients with lumbar stenosis
and concurrent degenerative spondylolisthesis (DS), and to determine
the effect of this procedure on spinal stability. A total of 304 consecutive patients with single-level lumbar
DS with concomitant stenosis underwent microendoscopic laminotomy
without fusion between January 2004 and December 2010. Patients
were divided into two groups, those with and without advanced DS
based on the degree of spondylolisthesis and dynamic instability. A
total of 242 patients met the inclusion criteria. There were 101
men and 141 women. Their mean age was 68.1 years (46 to 85). Outcome
was assessed using the Japanese Orthopaedic Association and Roland
Morris Disability Questionnaire scores, a visual analogue score
for pain and the Short Form Health-36 score. The radiographic outcome
was assessed by measuring the slip and the disc height. The clinical
and radiographic parameters were evaluated at a mean follow-up of
4.6 years (3 to 7.5).Aims
Patients and Methods
We examined the reliability of radiological findings in predicting segmental instability in 112 patients (56 men, 56 women) with a mean age of 66.5 years (27 to 84) who had degenerative disease of the lumbar spine. They underwent intra-operative biomechanical evaluation using a new measurement system. Biomechanical instability was defined as a segment with a neutral zone >
2 mm/N. Risk factor analysis to predict instability was performed on radiographs (range of segmental movement, disc height), MRI (Thompson grade, Modic type), and on the axial CT appearance of the facet (type, opening, vacuum and the presence of osteophytes, subchondral erosion, cysts and sclerosis) using multivariate logistic regression analysis with a forward stepwise procedure. The facet type was classified as sagittally orientated, coronally orientated, anisotropic or wrapped. Stepwise multivariate regression analysis revealed that facet opening was the strongest predictor for instability (odds ratio 5.022, p = 0.009) followed by spondylolisthesis, MRI grade and subchondral sclerosis. Forward stepwise multivariate logistic regression indicated that spondylolisthesis, MRI grade, facet opening and subchondral sclerosis of the facet were risk factors. Symptoms evaluated by the Short-Form 36 and visual analogue scale showed that patients with an unstable segment were in significantly more pain than those without. Furthermore, the surgical procedures determined using the intra-operative measurement system were effective, suggesting that segmental instability influences the symptoms of lumbar degenerative disease.
Between March 2000 and February 2006, we carried out a prospective study of 100 patients with a low-grade isthmic spondylolisthesis (Meyerding grade II or below), who were randomised to receive a single-level and instrumented posterior lumbar interbody fusion with either one or two cages. The minimum follow-up was for two years. At this stage 91 patients were available for review. A total of 47 patients received one cage (group 1) and 44 two cages (group 2). The clinical and radiological outcomes of the two groups were compared. There were no significant differences between the two groups in terms of post-operative pain, Oswestry Disability Score, clinical results, complication rate, percentage of post-operative slip, anterior fusion rate or posterior fusion rate. On the other hand, the mean operating time was 144 minutes (100 to 240) for patients in group 1 and 167 minutes (110 to 270) for those in group 2 (p = 0.0002). The mean blood loss up to the end of the first post-operative day was 756 ml (510 to 1440) in group 1 and 817 ml (620 to 1730) in group 2 (p <
0.0001). Our results suggest that an instrumented posterior lumbar interbody fusion performed with either one or two cages in addition to a bone graft around the cage has a low rate of complications and a high fusion rate. The clinical outcomes were good in most cases, regardless of whether one or two cages had been used.
The purpose of this study was to determine whether
it would be feasible to use oblique lumbar interbody fixation for
patients with degenerative lumbar disease who required a fusion
but did not have a spondylolisthesis. A series of CT digital images from 60 patients with abdominal
disease were reconstructed in three dimensions (3D) using Mimics
v10.01: a digital cylinder was superimposed on the reconstructed
image to simulate the position of an interbody screw. The optimal
entry point of the screw and measurements of its trajectory were
recorded. Next, 26 cadaveric specimens were subjected to oblique
lumbar interbody fixation on the basis of the measurements derived
from the imaging studies. These were then compared with measurements
derived directly from the cadaveric vertebrae. Our study suggested that it is easy to insert the screws for
L1/2, L2/3 and L3/4 fixation: there was no significant difference
in measurements between those of the 3-D digital images and the
cadaveric specimens. For L4/5 fixation, part of L5 inferior articular
process had to be removed to achieve the optimal trajectory of the
screw. For L5/S1 fixation, the screw heads were blocked by iliac
bone: consequently, the interior oblique angle of the cadaveric specimens
was less than that seen in the 3D digital images. We suggest that CT scans should be carried out pre-operatively
if this procedure is to be adopted in clinical practice. This will
assist in determining the feasibility of the procedure and will
provide accurate information to assist introduction of the screws. Cite this article:
Increasing numbers of posterior lumbar fusions
are being performed. The purpose of this study was to identify trends
in demographics, mortality and major complications in patients undergoing
primary posterior lumbar fusion. We accessed data collected for
the Nationwide Inpatient Sample for each year between 1998 and 2008
and analysed trends in the number of lumbar fusions, mean patient
age, comorbidity burden, length of hospital stay, discharge status,
major peri-operative complications and mortality. An estimated 1 288 496
primary posterior lumbar fusion operations were performed between
1998 and 2008 in the United States. The total number of procedures,
mean patient age and comorbidity burden increased over time. Hospital
length of stay decreased, although the in-hospital mortality (adjusted
and unadjusted for changes in length of hospital stay) remained
stable. However, a significant increase was observed in peri-operative
septic, pulmonary and cardiac complications. Although in-hospital mortality
rates did not change over time in the setting of increases in mean
patient age and comorbidity burden, some major peri-operative complications
increased. These trends highlight the need for appropriate peri-operative services
to optimise outcomes in an increasingly morbid and older population
of patients undergoing lumbar fusion.
The purpose of this prospective study was to evaluate the outcomes
of coccygectomy for patients with chronic coccydynia. Between 2007 and 2011, 98 patients underwent coccygectomy for
chronic coccydynia. The patients were aged >
18 years, had coccygeal
pain, local tenderness and a radiological abnormality, and had failed
conservative management. Outcome measures were the Short Form 36
(SF-36), the Oswestry Disability Index (ODI) and a visual analogue
scale (VAS) for pain. Secondary analysis compared the pre-operative
features and the outcomes of patients with successful and failed
treatment, two years post-operatively. The threshold for success
was based on a minimum clinically important difference (MCID) on
the ODI of 20 points. All other patients, including those lost to
follow-up, were classified as failures.Aims
Patients and Methods
We undertook a retrospective study investigating
the accuracy and safety of percutaneous pedicle screws placed under
fluoroscopic guidance in the lumbosacral junction and lumbar spine.
The CT scans of patients were chosen from two centres: European
patients from University Medical Center Hamburg-Eppendorf, Germany,
and Asian patients from the University of Malaya, Malaysia. Screw
perforations were classified into grades 0, 1, 2 and 3. A total
of 880 percutaneous pedicle screws from 203 patients were analysed:
614 screws from 144 European patients and 266 screws from 59 Asian
patients. The mean age of the patients was 58.8 years (16 to 91)
and there were 103 men and 100 women. The total rate of perforation
was 9.9% (87 screws) with 7.4% grade 1, 2.0% grade 2 and 0.5% grade
3 perforations. The rate of perforation in Europeans was 10.4% and
in Asians was 8.6%, with no significant difference between the two
(p = 0.42). The rate of perforation was the highest in S1 (19.4%)
followed by L5 (14.9%). The accuracy and safety of percutaneous
pedicle screw placement are comparable to those cited in the literature
for the open method of pedicle screw placement. Greater caution
must be taken during the insertion of L5 and S1 percutaneous pedicle
screws owing to their more angulated pedicles, the anatomical variations
in their vertebral bodies and the morphology of the spinal canal
at this location. Cite this article: