Advertisement for orthosearch.org.uk
Results 21 - 40 of 6328
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 29 - 34
1 Jan 2023
Fransen BL Bengoa FJ Neufeld ME Sheridan GA Garbuz DS Howard LC

Aims. Several short- and mid-term studies have shown minimal liner wear of highly cross-linked polyethylene (HXLPE) in total hip arthroplasty (THA), but the safety of using thinner HXLPE liners to maximize femoral head size remains uncertain. The objective of this study was to analyze clinical survival and radiological wear rates of patients with HXLPE liners, a 36 mm femoral head, and a small acetabular component with a minimum of ten years’ follow-up. Methods. We retrospectively identified 55 patients who underwent primary THA performed at a single centre, using HXLPE liners with 36 mm cobalt-chrome heads in acetabular components with an outer diameter of 52 mm or smaller. Patient demographic details, implant details, death, and all-cause revisions were recorded. Cox regression and Kaplan-Meier survival was used to determine all-cause and liner-specific revision. Of these 55 patients, 22 had a minimum radiological follow-up of seven years and were assessed radiologically for linear and volumetric wear. Results. Overall survival rate for all-cause revision was 94.5% (95% confidence interval (CI) 81.7% to 97.2%) at a mean follow-up of 12.8 years (10.9 to 18.7). Three patients were revised, none for liner wear, fracture, or dissociation. A total of 22 patients were included in the radiological analysis (mean follow-up 9.9 years (7.5 to 13.7)). Mean linear liner wear was 0.085 mm (95% CI -0.086 to 0.257) and the volumetric wear rate was 11.097 mm. 3. /year (95% CI -6.5 to 28.7). Conclusion. Using HXLPE liners with 36 mm heads in 52 mm acetabular components or smaller is safe, with excellent survival and low rates of linear and volumetric wear at medium-term follow-up. Patients did not require revision surgery for liner complications such as fracture, dissociation, or wear. Our results suggest that the advantages of using larger heads outweigh the potential risks of using thin HXLPE liners. Cite this article: Bone Joint J 2023;105-B(1):29–34


Bone & Joint Research
Vol. 13, Issue 5 | Pages 226 - 236
9 May 2024
Jürgens-Lahnstein JH Petersen ET Rytter S Madsen F Søballe K Stilling M

Aims. Micromotion of the polyethylene (PE) inlay may contribute to backside PE wear in addition to articulate wear of total knee arthroplasty (TKA). Using radiostereometric analysis (RSA) with tantalum beads in the PE inlay, we evaluated PE micromotion and its relationship to PE wear. Methods. A total of 23 patients with a mean age of 83 years (77 to 91), were available from a RSA study on cemented TKA with Maxim tibial components (Zimmer Biomet). PE inlay migration, PE wear, tibial component migration, and the anatomical knee axis were evaluated on weightbearing stereoradiographs. PE inlay wear was measured as the deepest penetration of the femoral component into the PE inlay. Results. At mean six years’ follow-up, the PE wear rate was 0.08 mm/year (95% confidence interval 0.06 to 0.09 mm/year). PE inlay external rotation was below the precision limit and did not influence PE wear. Varus knee alignment did not influence PE wear (p = 0.874), but increased tibial component total translation (p = 0.041). Conclusion. The PE inlay was well fixed and there was no relationship between PE stability and PE wear. The PE wear rate was low and similar in the medial and lateral compartments. Varus knee alignment did not influence PE wear. Cite this article: Bone Joint Res 2024;13(5):226–236


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1104 - 1109
1 Oct 2022
Hansjee S Giebaly DE Shaarani SR Haddad FS

We aim to explore the potential technologies for monitoring and assessment of patients undergoing arthroplasty by examining selected literature focusing on the technology currently available and reflecting on possible future development and application. The reviewed literature indicates a large variety of different hardware and software, widely available and used in a limited manner, to assess patients’ performance. There are extensive opportunities to enhance and integrate the systems which are already in existence to develop patient-specific pathways for rehabilitation.

Cite this article: Bone Joint J 2022;104-B(10):1104–1109.


Bone & Joint Open
Vol. 3, Issue 4 | Pages 275 - 283
1 Apr 2022
Ross LA O'Rourke SC Toland G MacDonald DJ Clement ND Scott CEH

Aims. The aim of this study was to determine satisfaction rates after hip and knee arthroplasty in patients who did not respond to postoperative patient-reported outcome measures (PROMs), characteristics of non-responders, and contact preferences to maximize response rates. Methods. A prospective cohort study of patients planned to undergo hip arthroplasty (n = 713) and knee arthroplasty (n = 737) at a UK university teaching hospital who had completed preoperative PROMs questionnaires, including the EuroQol five-dimension health-related quality of life score, and Oxford Hip Score (OHS) and Oxford Knee Score (OKS). Follow-up questionnaires were sent by post at one year, including satisfaction scoring. Attempts were made to contact patients who did not initially respond. Univariate, logistic regression, and receiver operator curve analysis was performed. Results. At one year, 667 hip patients (93.5%) and 685 knee patients (92.9%) had undergone surgery and were alive. No response was received from 151/667 hip patients (22.6%), 83 (55.0%) of whom were ultimately contacted); or from 108/685 knee patients (15.8%), 91 (84.3%) of whom were ultimately contacted. There was no difference in satisfaction after arthroplasty between initial non-responders and responders for hips (74/81 satisfied vs 476/516 satisfied; p = 0.847) or knees (81/93 satisfied vs 470/561 satisfied; p = 0.480). Initial non-response and persistent non-response was associated with younger age, higher BMIs, and worse preoperative PROMs for both hip and knee patients (p < 0.050). Being in employment was associated with persistent non-response for hip patients (p = 0.047). Multivariate analysis demonstrated that younger age (p < 0.038), higher BMI (p = 0.018), and poorer preoperative OHS (p = 0.031) were independently associated with persistent non-response to hip PROMs. No independent associations were identified for knees. Using a threshold of > 66.4 years predicted a preference for contact by post (area under the curve 0.723 (95% confidence interval (CI) 0.647 to 0.799; p < 0.001, though this CI crosses the 0.7 limit considered reliable). Conclusion. The majority of initial non-responders were ultimately contactable with effort. Satisfaction rates were not inferior in patients who did not initially respond to PROMs. Cite this article: Bone Jt Open 2022;3(4):275–283


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 66 - 72
1 Jul 2021
Hernandez NM Hinton ZW Wu CJ Lachiewicz PF Ryan SP Wellman SS

Aims. Modular dual mobility (MDM) acetabular components are often used with the aim of reducing the risk of dislocation in revision total hip arthroplasty (THA). There is, however, little information in the literature about its use in this context. The aim of this study, therefore, was to evaluate the outcomes in a cohort of patients in whom MDM components were used at revision THA, with a mean follow-up of more than five years. Methods. Using the database of a single academic centre, 126 revision THAs in 117 patients using a single design of an MDM acetabular component were retrospectively reviewed. A total of 94 revision THAs in 88 patients with a mean follow-up of 5.5 years were included in the study. Survivorship was analyzed with the endpoints of dislocation, reoperation for dislocation, acetabular revision for aseptic loosening, and acetabular revision for any reason. The secondary endpoints were surgical complications and the radiological outcome. Results. The overall rate of dislocation was 11%, with a six-year survival of 91%. Reoperation for dislocation was performed in seven patients (7%), with a six-year survival of 94%. The dislocations were early (at a mean of 33 days) in six patients, and late (at a mean of 4.3 years) in four patients. There were three intraprosthetic dissociations. An outer head diameter of ≥ 48 mm was associated with a lower risk of dislocation (p = 0.013). Lumbrosacral fusion was associated with increased dislocation (p = 0.004). Four revision THAs (4%) were further revised for aseptic acetabular loosening, and severe bone loss (Paprosky III) at the time of the initial revision was significantly associated with further revision for aseptic acetabular loosening (p = 0.008). Fourteen acetabular components (15%) were re-revised for infection, and a pre-revision diagnosis of reimplantation after periprosthetic joint infection (PJI) was associated with subsequent PJI (p < 0.001). Two THAs had visible metallic changes on the backside of the cobalt chromium liner. Conclusion. When using this MDM component in revision THA, at a mean follow-up of 5.5 years, there was a higher rate of dislocation (11%) than previously reported. The size of the outer bearing was related to the risk of dislocation. There was a low rate of aseptic acetabular loosening. Longer follow-up of this MDM component and evaluation of other designs are warranted. Cite this article: Bone Joint J 2021;103-B(7 Supple B):66–72


Bone & Joint Open
Vol. 2, Issue 12 | Pages 1075 - 1081
17 Dec 2021
Suthar A Yukata K Azuma Y Suetomi Y Yamazaki K Seki K Sakai T Fujii H

Aims. This study aimed to investigate the relationship between changes in patellar height and clinical outcomes at a mean follow-up of 7.7 years (5 to 10) after fixed-bearing posterior-stabilized total knee arthroplasty (PS-TKA). Methods. We retrospectively evaluated knee radiographs of 165 knees, which underwent fixed-bearing PS-TKA with patella resurfacing. The incidence of patella baja and changes in patellar height over a minimum of five years of follow-up were determined using Insall-Salvati ratio (ISR) measurement. We examined whether patella baja (ISR < 0.8) at final follow-up affected clinical outcomes, knee joint range of motion (ROM), and Knee Society Score (KSS). We also assessed inter- and intrarater reliability of ISR measurements and focused on the relationship between patellar height reduction beyond measurement error and clinical outcomes. Results. The ISR gradually decreased over five years after TKA, and finally 33 patients (20.0%) had patella baja. Patella baja at the final follow-up was not related to passive knee ROM or KSS. Interestingly, when we divided into two groups - patella baja and patella normal-alta (ISR ≥ 0.8) - the patella baja group already had a lower patellar height before surgery, compared with the patella normal-alta group. The ISR measurement error in this study was 0.17. Both passive knee flexion and KSS were significantly decreased in the group with a decrease in ISR of ≥ 0.17 at final follow-up. Conclusion. Patellar height gradually decreased over five years of follow-up after TKA. The reduction in patellar height beyond measurement error following TKA was associated with lower clinical outcomes. Cite this article: Bone Jt Open 2021;2(12):1075–1081


Bone & Joint Open
Vol. 4, Issue 11 | Pages 846 - 852
8 Nov 2023
Kim RG Maher AW Karunaratne S Stalley PD Boyle RA

Aims. Tenosynovial giant cell tumour (TGCT) is a rare benign tumour of the musculoskeletal system. Surgical management is fraught with challenges due to high recurrence rates. The aim of this study was to describe surgical treatment and evaluate surgical outcomes of TGCT at an Australian tertiary referral centre for musculoskeletal tumours and to identify factors affecting recurrence rates. Methods. A prospective database of all patients with TGCT surgically managed by two orthopaedic oncology surgeons was reviewed. All cases irrespective of previous treatment were included and patients without follow-up were excluded. Pertinent tumour characteristics and surgical outcomes were collected for analysis. Results. There were 111 total cases included in the study; 71 (64%) were female, the mean age was 36 years (SD 13.6), and the knee (n = 64; 57.7%) was the most commonly affected joint. In all, 60 patients (54.1%) had diffuse-type (D-TGCT) disease, and 94 patients (84.7%) presented therapy-naïve as "primary cases" (PC). The overall recurrence rate was 46.8% for TGCT. There was a statistically significant difference in recurrence rates between D-TGCT and localized disease (75.0% vs 13.7%, relative risk (RR) 3.40, 95% confidence interval (CI) 2.17 to 5.34; p < 0.001), and for those who were referred in the ”revision cases” (RC) group compared to the PC group (82.4% vs 48.9%, RR 1.68, 95% CI 1.24 to 2.28; p = 0.011). Age, sex, tumour volume, and mean duration of symptoms were not associated with recurrence (p > 0.05). Conclusion. Recurrence rates remain high even at a tertiary referral hospital. Highest rates are seen in D-TGCT and “revision cases”. Due to the risks of recurrence, the complexity of surgery, and the need for adjuvant therapy, this paper further supports the management of TGCT in a tertiary referral multi-disciplinary orthopaedic oncology service. Cite this article: Bone Jt Open 2023;4(11):846–852


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 136 - 143
1 Feb 2024
van der Lelij TJN Marang-van de Mheen PJ Kaptein BL Koster LA Ljung P Nelissen RGHH Toksvig-Larsen S

Aims. The objective of this study was to compare the two-year migration and clinical outcomes of a new cementless hydroxyapatite (HA)-coated titanium acetabular shell with its previous version, which shared the same geometrical design but a different manufacturing process for applying the titanium surface. Methods. Overall, 87 patients undergoing total hip arthroplasty (THA) were randomized to either a Trident II HA or Trident HA shell, each cementless with clusterholes and HA-coating. All components were used in combination with a cemented Exeter V40 femoral stem. Implant migration was measured using radiostereometric analysis (RSA), with radiographs taken within two days of surgery (baseline), and at three, 12, and 24 months postoperatively. Proximal acetabular component migration was the primary outcome measure. Clinical scores and patient-reported outcome measures (PROMs) were collected at each follow-up. Results. Mean proximal migrations at three, 12, and 24 months were 0.08 mm (95% confidence interval (CI) 0.03 to 0.14), 0.11 mm (95% CI 0.06 to 0.16), and 0.14 mm (95% CI 0.09 to 0.20), respectively, in the Trident II HA group, versus 0.11 mm (95% CI 0.06 to 0.16), 0.12 mm (95% CI 0.07 to 0.17), and 0.14 mm (95% CI 0.09 to 0.19) in the Trident HA group (p = 0.875). No significant differences in translations or rotations between the two designs were found in any other direction. Clinical scores and PROMs were comparable between groups, except for an initially greater postoperative improvement in Hip disability and Osteoarthritis Outcome Symptoms score in the Trident HA group (p = 0.033). Conclusion. The Trident II clusterhole HA shell has comparable migration with its predecessor, the Trident hemispherical HA cluster shell, suggesting a similar risk of long-term aseptic loosening. Cite this article: Bone Joint J 2024;106-B(2):136–143


Bone & Joint Open
Vol. 5, Issue 10 | Pages 937 - 943
22 Oct 2024
Gregor RH Hooper GJ Frampton C

Aims

The aim of this study was to determine whether obesity had a detrimental effect on the long-term performance and survival of medial unicompartmental knee arthroplasties (UKAs).

Methods

This study reviewed prospectively collected functional outcome scores and revision rates of all medial UKA patients with recorded BMI performed in Christchurch, New Zealand, from January 2011 to September 2021. Patient-reported outcome measures (PROMs) were the primary outcome of this study, with all-cause revision rate analyzed as a secondary outcome. PROMs were taken preoperatively, at six months, one year, five years, and ten years postoperatively. There were 873 patients who had functional scores recorded at five years and 164 patients had scores recorded at ten years. Further sub-group analysis was performed based on the patient’s BMI. Revision data were available through the New Zealand Joint Registry for 2,323 UKAs performed during this time period.


Bone & Joint Open
Vol. 4, Issue 7 | Pages 490 - 495
4 Jul 2023
Robinson PG Creighton AP Cheng J Dines JS Su EP Gulotta LV Padgett D Demetracopoulos C Hawkes R Prather H Press JM Clement ND

Aims

The primary aim of this prospective, multicentre study is to describe the rates of returning to golf following hip, knee, ankle, and shoulder arthroplasty in an active golfing population. Secondary aims will include determining the timing of return to golf, changes in ability, handicap, and mobility, and assessing joint-specific and health-related outcomes following surgery.

Methods

This is a multicentre, prospective, longitudinal study between the Hospital for Special Surgery, (New York City, New York, USA) and Edinburgh Orthopaedics, Royal Infirmary of Edinburgh, (Edinburgh, UK). Both centres are high-volume arthroplasty centres, specializing in upper and lower limb arthroplasty. Patients undergoing hip, knee, ankle, or shoulder arthroplasty at either centre, and who report being golfers prior to arthroplasty, will be included. Patient-reported outcome measures will be obtained at six weeks, three months, six months, and 12 months. A two-year period of recruitment will be undertaken of arthroplasty patients at both sites.


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 132 - 136
1 Jan 2020
Hommel H Becker R Fennema P Kopf S

Aims. We report the natural course of Baker’s cysts following total knee arthroplasty (TKA) at short- and mid-term follow-up. Methods. In this prospective case series, 105 TKA patients were included. All patients who received surgery had a diagnosis of primary osteoarthritis and had preoperatively presented with a Baker’s cyst. Sonography and MRI were performed to evaluate the existence and the gross size of the cyst before TKA, and sonography was repeated at a mean follow-up time of 1.0 years (0.8 to 1.3; short-term) and 4.9 years (4.0 to 5.6; mid-term) after TKA. Symptoms potentially attributable to the Baker’s cyst were recorded at each assessment. Results. At the one-year follow-up analysis, 102 patients were available. Of those, 91 patients were available for the 4.9-year assessment (with an 86.7% follow-up rate (91/105)). At the short- and mid-term follow-up, a Baker’s cyst was still present in 87 (85.3%) and 30 (33.0%) patients, respectively. Of those patients who retained a Baker’s cyst at the short-term follow-up, 31 patients (35.6%) had popliteal symptoms. Of those patients who continued to have a Baker’s cyst at the mid-term follow-up, 17 patients (56.7%) were still symptomatic. The mean preoperative cyst size was 14.5 cm. 2. (13.1 to 15.8). At the short- and mid-term follow-up, the mean cyst size was 9.7 cm. 2. (8.3 to 11.0) and 10.4 cm. 2. (9.8 to 11.4), respectively. A significant association was found between the size of the cyst at peroperatively and the probability of resolution, with lesions smaller than the median having an 83.7% (36/43) probability of resolution, and larger lesions having a 52.1% (25/48) probability of resolution (p < 0.001). At the mid-term follow-up, no association between cyst size and popliteal symptoms was found. Conclusion. At a mean follow-up of 4.9 years (4.0 to 5.6) after TKA, the majority (67.0%, 61/91) of the Baker’s cysts that were present preoperatively had disappeared. The probability of cyst resolution was dependent on the size of the Baker’s cyst at baseline, with an 83.7% (36/43) probability of resolution for smaller cysts and 52.1% (25/48) probability for larger cysts. Cite this article: Bone Joint J. 2020;102-B(1):132–136


The Bone & Joint Journal
Vol. 102-B, Issue 7 Supple B | Pages 85 - 89
1 Jul 2020
Barrack TN Abu-Amer W Schwabe MT Adelani MA Clohisy JC Nunley RM Lawrie CM

Aims. Routine surveillance of primary hip and knee arthroplasties has traditionally been performed with office follow-up visits at one year postoperatively. The value of these visits is unclear. The present study aims to determine the utility and burden of routine clinical follow-up at one year after primary arthroplasty to patients and providers. Methods. All patients (473) who underwent primary total hip (280), hip resurfacing (eight), total knee (179), and unicompartmental knee arthroplasty (six) over a nine-month period at a single institution were identified from an institutional registry. Patients were prompted to attend their routine one-year postoperative visit by a single telephone reminder. Patients and surgeons were given questionnaires at the one-year postoperative visit, defined as a clinical encounter occurring at nine to 15 months from the date of surgery, regarding value of the visit. Results. Compliance with routine follow-up at one year was 35%. The response rate was over 80% for all questions in the patient and clinician surveys. Overall, 75% of the visits were for routine surveillance. Patients reported high satisfaction with their visits despite the general time for attendance, including travel, being over four hours. Surgeons found the visits more worthwhile when issues were identified or problems were addressed. Conclusion. Patient compliance with follow-up at one year postoperatively after primary hip and knee is low. Routine visits of asymptomatic patients deliver little practical value and represent a large time and cost burden for patients and surgeons. Remote strategies should be considered for routine postoperative surveillance primary hip and knee arthroplasties beyond the acute postoperative period. Cite this article: Bone Joint J 2020;102-B(7 Supple B):85–89


The Bone & Joint Journal
Vol. 104-B, Issue 12 | Pages 1352 - 1361
1 Dec 2022
Trovarelli G Pala E Angelini A Ruggieri P

Aims

We performed a systematic literature review to define features of patients, treatment, and biological behaviour of multicentric giant cell tumour (GCT) of bone.

Methods

The search terms used in combination were “multicentric”, “giant cell tumour”, and “bone”. Exclusion criteria were: reports lacking data, with only an abstract; papers not reporting data on multicentric GCT; and papers on multicentric GCT associated with other diseases. Additionally, we report three patients treated under our care.


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 13 - 17
1 Jun 2021
Park KJ Chapleau J Sullivan TC Clyburn TA Incavo SJ

Aims. Infection complicating primary total knee arthroplasty (TKA) is a common reason for revision surgery, hospital readmission, patient morbidity, and mortality. Increasing incidence of methicillin-resistant Staphylococcus aureus (MRSA) is a particular concern. The use of vancomycin as prophylactic agent alone or in combination with cephalosporin has not demonstrated lower periprosthetic joint infection (PJI) rates, partly due to timing and dosing of intravenous (IV) vancomycin administration, which have proven important factors in effectiveness. This is a retrospective review of a consecutive series of primary TKAs examining incidence of PJI, adverse reactions, and complications using IV versus intraosseous (IO) vancomycin at 30-day, 90-day, and one-year follow-up. Methods. A retrospective review of 1,060 patients who underwent TKA between May 2016 to July 2020 was performed. There were 572 patients in the IV group and 488 in the IO group, with minimal 30 days of follow-up. Patients were followed up at regularly scheduled intervals (two, six, and 12 weeks). No differences between groups for age, sex, BMI, or baseline comorbidities existed. The IV group received an IV dose of 15 mg/kg vancomycin given over an hour preceding skin incision. The IO group received a 500 mg dose of vancomycin mixed in 150 ml of normal saline, injected into proximal tibia after tourniquet inflation, before skin incision. All patients received an additional dose of first generation cephalosporin. Evaluation included preoperative and postoperative serum creatinine values, tourniquet time, and adverse reactions attributable to vancomycin. Results. Incidence of PJI with minimum 90-day follow-up was 1.4% (eight knees) in the IV group and 0.22% (one knee) in IO group (p = 0.047). This preliminary report demonstrated an reduction in the incidence of infection in TKA using IO vancomycin combined with a first-generation cephalosporin. While the study suffers from limitations of a retrospective, multi-surgeon investigation, early findings are encouraging. Conclusion. IO delivery of vancomycin after tourniquet inflation is a safe and effective alternative to IV administration, eliminating the logistical challenges of timely dosing. Cite this article: Bone Joint J 2021;103-B(6 Supple A):13–17


Aims. The aim of this study was to compare the mid-term patient-reported outcome, bone remodelling, and migration of a short stem (Collum Femoris Preserving; CFP) with a conventional uncemented stem (Corail). Methods. Of 81 patients who were initially enrolled, 71 were available at five years’ follow-up. The outcomes at two years have previously been reported. The primary outcome measure was the clinical result assessed using the Oxford Hip Score (OHS). Secondary outcomes were the migration of the stem, measured using radiostereometric analysis (RSA), change of bone mineral density (BMD) around the stem, the development of radiolucent lines, and additional patient-reported outcome measures (PROMs). Results. There were no statistically significant differences between the groups regarding PROMs (median OHS (CFP 45 (interquartile range (IQR) 35 to 48); Corail 45 (IQR 40 to 48); p = 0.568). RSA showed stable stems in both groups, with little or no further subsidence between two and five years. Resorption of the femoral neck was evident in nine patients in the CFP group and in none of the 15 Corail stems with a collar that could be studied. Dual X-ray absorbiometry showed a significantly higher loss of BMD in the proximal Gruen zones in the CFP group (mean changes in BMD: Gruen zone 1, CFP -9.5 (95% confidence interval (CI) -14.8 to -4.2), Corail 1.0 (95% CI 3.4 to 5.4); Gruen zone 7, CFP -23.0 (95% CI -29.4 to -16.6), Corail -7.2 (95% CI -15.9 to 1.4). Two CFP stems were revised before two years’ follow-up due to loosening, and one Corail stem was revised after two years due to chronic infection. Conclusion. The CFP stem has a similar clinical outcome and subsidence pattern when compared with the Corail stem. More pronounced proximal stress-shielding was seen with the CFP stem, suggesting diaphyseal fixation, and questioning its femoral neck-sparing properties in the long term. Cite this article: Bone Joint J 2022;104-B(5):581–588


The Bone & Joint Journal
Vol. 99-B, Issue 12 | Pages 1561 - 1570
1 Dec 2017
Laumonerie P Reina N Kerezoudis P Declaux S Tibbo ME Bonnevialle N Mansat P

Aims. The primary aim of this study was to define the standard minimum follow-up required to produce a reliable estimate of the rate of re-operation after radial head arthroplasty (RHA). The secondary objective was to define the leading reasons for re-operation. Materials and Methods. Four electronic databases, between January 2000 and March 2017 were searched. Articles reporting reasons for re-operation (Group I) and results (Group II) after RHA were included. In Group I, a meta-analysis was performed to obtain the standard minimum follow-up, the mean time to re-operation and the reason for failure. In Group II, the minimum follow-up for each study was compared with the standard minimum follow-up. Results. A total of 40 studies were analysed: three were Group I and included 80 implants and 37 were Group II and included 1192 implants. In Group I, the mean time to re-operation was 1.37 years (0 to 11.25), the standard minimum follow-up was 3.25 years; painful loosening was the main indication for re-operation. In Group II, 33 Group II articles (89.2%) reported a minimum follow-up of < 3.25 years. Conclusion. The literature does not provide a reliable estimate of the rate of re-operation after RHA. The reproducibility of results would be improved by using a minimum follow-up of three years combined with a consensus of the definition of the reasons for failure after RHA. Cite this article: Bone Joint J 2017;99-B:1561–70


Bone & Joint Open
Vol. 1, Issue 4 | Pages 80 - 87
24 Apr 2020
Passaplan C Gautier L Gautier E

Aims. Our retrospective analysis reports the outcome of patients operated for slipped capital femoral epiphysis using the modified Dunn procedure. Results, complications, and the need for revision surgery are compared with the recent literature. Methods. We retrospectively evaluated 17 patients (18 hips) who underwent the modified Dunn procedure for the treatment of slipped capital femoral epiphysis. Outcome measurement included standardized scores. Clinical assessment included ambulation, leg length discrepancy, and hip mobility. Radiographically, the quality of epiphyseal reduction was evaluated using the Southwick and Alpha-angles. Avascular necrosis, heterotopic ossifications, and osteoarthritis were documented at follow-up. Results. At a mean follow-up of more than nine years, the mean modified Harris Hip score was 88.7 points, the Hip Disability and Osteoarthritis Outcome Score (HOOS) 87.4 , the Merle d’Aubigné Score 16.5 points, and the UCLA Activity Score 8.4. One patient developed a partial avascular necrosis of the femoral head, and one patient already had an avascular necrosis at the time of delayed diagnosis. Two hips developed osteoarthritic signs at 14 and 16 years after the index operation. Six patients needed a total of nine revision surgeries. One operation was needed for postoperative hip subluxation, one for secondary displacement and implant failure, two for late femoroacetabular impingement, one for femoroacetabular impingement of the opposite hip, and four for implant removal. Conclusion. Our series shows good results and is comparable to previous published studies. The modified Dunn procedure allows the anatomic repositioning of the slipped epiphysis. Long-term results with subjective and objective hip function are superior, avascular necrosis and development of osteoarthritis inferior to other reported treatment modalities. Nevertheless, the procedure is technically demanding and revision surgery for secondary femoroacetabular impingement and implant removal are frequent. Cite this article: 2020;1-4:80–87


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 951 - 957
1 May 2021
Ng N Nicholson JA Chen P Yapp LZ Gaston MS Robinson CM

Aims. The aim of this study was to define the complications and long-term outcome following adolescent mid-shaft clavicular fracture. Methods. We retrospectively reviewed a consecutive series of 677 adolescent fractures in 671 patients presenting to our region (age 13 to 17 years) over a ten-year period (2009 to 2019). Long-term patient-reported outcomes (abbreviated version of the Disabilities of the Arm, Shoulder and Hand (QuickDASH) score and EuroQol five-dimension three-level (EQ-5D-3L) quality of life score) were undertaken at a mean of 6.4 years (1.2 to 11.3) following injury in severely displaced mid-shaft fractures (Edinburgh 2B) and angulated mid-shaft fractures (Edinburgh 2A2) at a minimum of one year post-injury. The median patient age was 14.8 years (interquartile range (IQR) 14.0 to 15.7) and 89% were male (n = 594/671). Results. The majority of fractures were mid-shaft (n = 606) with angulation (Edinburgh 2A2, n = 241/606, 39.8%) or displacement (Edinburgh 2B1/2, n = 263/606, 43.4%). Only 7% of the displaced mid-shaft fractures underwent acute fixation (n = 18/263). The incidence of refracture over ten years following nonoperative management of mid-shaft fractures was 3.2% (n = 19/588) and all united without surgery. Fracture type, severity of angulation, or displacement were not associated with refracture. One nonunion occurred following nonoperative management in a displaced mid-shaft fracture (0.4%, n = 1/245). Of the angulated fractures, 61 had angulation > 30°, of which 68.9% (n = 42/61) completed outcome scores with a median QuickDASH of 0.0 (IQR 0.0 to 0.6), EQ-5D-3L 1.0 (1.0 to 1.0), and 98% satisfaction with shoulder function. For the displaced fractures, 127 had displacement beyond one cortical width of bone for which completed outcome scores were provided in 72.4% (n = 92/127). Of these 15 had undergone acute fixation. Following nonoperative treatment, the median QuickDASH was 0.0 (IQR 0.0 to 2.3), EQ-5D-3L 1.0 (1.0 to 1.0), and satisfaction with shoulder function was 95%. There were no significant differences in the patients’ demography or functional outcomes between operative and nonoperative treatments. Conclusion. Nonoperative management of adolescent mid-shaft clavicle fractures results in excellent functional outcomes at long-term follow-up. Nonunion is exceptionally rare following nonoperative management and the relative indications for surgical intervention in adults do not appear to be applicable to adolescents. Cite this article: Bone Joint J 2021;103-B(5):951–957


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 918 - 924
1 Jul 2020
Rosslenbroich SB Heimann K Katthagen JC Koesters C Riesenbeck O Petersen W Raschke MJ Schliemann B

Aims. There is a lack of long-term data for minimally invasive acromioclavicular (AC) joint repair. Furthermore, it is not clear if good early clinical results can be maintained over time. The purpose of this study was to report long-term results of minimally invasive AC joint reconstruction (MINAR) and compare it to corresponding short-term data. Methods. We assessed patients with a follow-up of at least five years after minimally invasive flip-button repair for high-grade AC joint dislocation. The clinical outcome was evaluated using the Constant score and a questionnaire. Ultrasound determined the coracoclavicular (CC) distance. Results of the current follow-up were compared to the short-term results of the same cohort. Results. A total of 50 patients (three females, 47 males) were successfully followed up for a minimum of five years. The mean follow-up was 7.7 years (63 months to 132 months). The overall Constant score was 94.4 points (54 to 100) versus 97.7 points (83 to 100) for the contralateral side showing a significant difference for the operated shoulder (p = 0.013) The mean difference in the CC distance between the operated and the contralateral shoulder was 3.7 mm (0.2 to 7.8; p = 0.010). In total, 16% (n = 8) of patients showed recurrent instability. All these cases were performed within the first 16 months after introduction of this technique. A total of 84% (n = 42) of the patients were able to return to their previous occupations and sport activities. Comparison of short-term and long-term results revealed no significant difference for the Constant Score (p = 0.348) and the CC distance (p = 0.974). Conclusion. The clinical outcome of MINAR is good to excellent after long-term follow-up and no significant differences were found compared to short-term results. We therefore suggest this is a reliable technique for surgical treatment of high-grade AC joint dislocation. Cite this article: Bone Joint J 2020;102-B(7):918–924


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 434 - 441
1 Apr 2020
Hamilton DF Burnett R Patton JT MacPherson GJ Simpson AHRW Howie CR Gaston P

Aims. There are comparatively few randomized studies evaluating knee arthroplasty prostheses, and fewer still that report longer-term functional outcomes. The aim of this study was to evaluate mid-term outcomes of an existing implant trial cohort to document changing patient function over time following total knee arthroplasty using longitudinal analytical techniques and to determine whether implant design chosen at time of surgery influenced these outcomes. Methods. A mid-term follow-up of the remaining 125 patients from a randomized cohort of total knee arthroplasty patients (initially comprising 212 recruited patients), comparing modern (Triathlon) and traditional (Kinemax) prostheses was undertaken. Functional outcomes were assessed with the Oxford Knee Score (OKS), knee range of movement, pain numerical rating scales, lower limb power output, timed functional assessment battery, and satisfaction survey. Data were linked to earlier assessment timepoints, and analyzed by repeated measures analysis of variance (ANOVA) mixed models, incorporating longitudinal change over all assessment timepoints. Results. The mean follow-up of the 125 patients was 8.12 years (7.3 to 9.4). There was a reduction in all assessment parameters relative to earlier assessments. Longitudinal models highlight changes over time in all parameters and demonstrate large effect sizes. Significant between-group differences were seen in measures of knee flexion (medium-effect size), lower limb power output (large-effect size), and report of worst daily pain experienced (large-effect size) favouring the Triathlon group. No longitudinal between-group differences were observed in mean OKS, average daily pain report, or timed performance test. Satisfaction with outcome in surviving patients at eight years was 90.5% (57/63) in the Triathlon group and 82.8% (48/58) in the Kinemax group, with no statistical difference between groups (p = 0.321). Conclusion. At a mean 8.12 years, this mid-term follow-up of a randomized controlled trial cohort highlights a general reduction in measures of patient function with patient age and follow-up duration, and a comparative preservation of function based on implant received at time of surgery. Cite this article: Bone Joint J 2020;102-B(4):434–441