Advertisement for orthosearch.org.uk
Results 21 - 40 of 1999
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 833 - 843
1 Jul 2022
Kayani B Baawa-Ameyaw J Fontalis A Tahmassebi J Wardle N Middleton R Stephen A Hutchinson J Haddad FS

Aims. This study reports the ten-year wear rates, incidence of osteolysis, clinical outcomes, and complications of a multicentre randomized controlled trial comparing oxidized zirconium (OxZr) versus cobalt-chrome (CoCr) femoral heads with ultra-high molecular weight polyethylene (UHMWPE) and highly cross-linked polyethylene (XLPE) liners in total hip arthroplasty (THA). Methods. Patients undergoing primary THA were recruited from four institutions and prospectively allocated to the following treatment groups: Group A, CoCr femoral head with XLPE liner; Group B, OxZr femoral head with XLPE liner; and Group C, OxZr femoral head with UHMWPE liner. All study patients and assessors recording outcomes were blinded to the treatment groups. The outcomes of 262 study patients were analyzed at ten years’ follow-up. Results. Patients in Group C were associated with increased mean liner wear rates compared to patients in Group A (0.133 mm/yr (SD 0.21) vs 0.031 mm/yr (SD 0.07), respectively; p < 0.001) and Group B (0.133 mm/yr (SD 0.21) vs 0.022 mm/yr (SD 0.05), respectively; p < 0.001) at ten years’ follow-up. Patients in Group C were also associated with increased risk of osteolysis and aseptic loosening requiring revision surgery, compared with patients in Group A (7/133 vs 0/133, respectively; p = 0.007) and Group B (7/133 vs 0/135, respectively; p = 0.007). There was a non-statistically significant trend towards increased mean liner wear rates in Group A compared with Group B (0.031 mm/yr (SD 0.07) vs 0.022 mm/yr (SD 0.05), respectively; p = 0.128). All three groups were statistically comparable preoperatively and at ten years’ follow-up when measuring normalized Western Ontario and McMaster Universities Osteoarthritis Index (p = 0.410), 36-Item Short Form Health Survey (p = 0.465 mental, p = 0.713 physical), and pain scale scores (p = 0.451). Conclusion. The use of UHMWPE was associated with progressively increased annual liner wear rates after THA compared to XLPE. At ten years’ follow-up, the group receiving UHMWPE demonstrated an increased incidence of osteolysis and aseptic loosening requiring revision surgery compared to XLPE. Femoral heads composed of OxZr were associated with trend towards reduced wear rates compared to CoCr, but this did not reach statistical significance and did not translate to any differences in osteolysis, functional outcomes, or revision surgery between the two femoral head components. Cite this article: Bone Joint J 2022;104-B(7):833–843


Bone & Joint Research
Vol. 13, Issue 11 | Pages 673 - 681
22 Nov 2024
Yue C Xue Z Cheng Y Sun C Liu Y Xu B Guo J

Aims. Pain is the most frequent complaint associated with osteonecrosis of the femoral head (ONFH), but the factors contributing to such pain are poorly understood. This study explored diverse demographic, clinical, radiological, psychological, and neurophysiological factors for their potential contribution to pain in patients with ONFH. Methods. This cross-sectional study was carried out according to the “STrengthening the Reporting of OBservational studies in Epidemiology” statement. Data on 19 variables were collected at a single timepoint from 250 patients with ONFH who were treated at our medical centre between July and December 2023 using validated instruments or, in the case of hip pain, a numerical rating scale. Factors associated with pain severity were identified using hierarchical multifactor linear regression. Results. Regression identified the following characteristics as independently associated with higher pain score, after adjustment for potential confounders: Association Research Circulation Osseous classification stage IIIa or IIIb, bone marrow oedema, grade 3 joint effusion, as well as higher scores on pain catastrophizing, anxiety, and central sensitization. The final model explained 69.7% of observed variance in pain scores, of which clinical and radiological factors explained 37%, while psychological and neurophysiological factors explained 24% and demographic factors explained 8.7%. Conclusion. Multidimensional characteristics jointly contribute to the severity of pain associated with ONFH. These findings highlight the need to comprehensively identify potential contributors to pain, and to personalize management and treatment accordingly. Cite this article: Bone Joint Res 2024;13(11):673–681


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 496 - 503
1 May 2023
Mills ES Talehakimi A Urness M Wang JC Piple AS Chung BC Tezuka T Heckmann ND

Aims. It has been well documented in the arthroplasty literature that lumbar degenerative disc disease (DDD) contributes to abnormal spinopelvic motion. However, the relationship between the severity or pattern of hip osteoarthritis (OA) as measured on an anteroposterior (AP) pelvic view and spinopelvic biomechanics has not been well investigated. Therefore, the aim of the study is to examine the association between the severity and pattern of hip OA and spinopelvic motion. Methods. A retrospective chart review was conducted to identify patients undergoing primary total hip arthroplasty (THA). Plain AP pelvic radiographs were reviewed to document the morphological characteristic of osteoarthritic hips. Lateral spine-pelvis-hip sitting and standing plain radiographs were used to measure sacral slope (SS) and pelvic femoral angle (PFA) in each position. Lumbar disc spaces were measured to determine the presence of DDD. The difference between sitting and standing SS and PFA were calculated to quantify spinopelvic motion (ΔSS) and hip motion (ΔPFA), respectively. Univariate analysis and Pearson correlation were used to identify morphological hip characteristics associated with changes in spinopelvic motion. Results. In total, 139 patients were included. Increased spinopelvic motion was observed in patients with loss of femoral head contour, cam deformity, and acetabular bone loss (all p < 0.05). Loss of hip motion was observed in patients with loss of femoral head contour, cam deformity, and acetabular bone loss (all p < 0.001). A decreased joint space was associated with a decreased ΔPFA (p = 0.040). The presence of disc space narrowing, disc space narrowing > two levels, and disc narrowing involving the L5–S1 segment were associated with decreased spinopelvic motion (all p < 0.05). Conclusion. Preoperative hip OA as assessed on an AP pelvic radiograph predicts spinopelvic motion. These data suggest that specific hip osteoarthritic morphological characteristics listed above alter spinopelvic motion to a greater extent than others. Cite this article: Bone Joint J 2023;105-B(5):496–503


The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1656 - 1661
1 Nov 2021
Iwasa M Ando W Uemura K Hamada H Takao M Sugano N

Aims. Pelvic incidence (PI) is considered an important anatomical parameter for determining the sagittal balance of the spine. The contribution of an abnormal PI to hip osteoarthritis (OA) remains controversial. In this study, we aimed to investigate the relationship between PI and hip OA, and the difference in PI between hip OA without anatomical abnormalities (primary OA) and hip OA with developmental dysplasia of the hip (DDH-OA). Methods. In this study, 100 patients each of primary OA, DDH-OA, and control subjects with no history of hip disease were included. CT images were used to measure PI, sagittal femoral head coverage, α angle, and acetabular anteversion. PI was also subdivided into three categories: high PI (larger than 64.0°), medium PI (42.0° to 64.0°), and low PI (less than 42.0°). The anterior centre edge angles, posterior centre edge angles, and total sagittal femoral head coverage were measured. The correlations between PI and sagittal femoral head coverage, α angle, and acetabular anteversion were examined. Results. No significant difference in PI was observed between the three groups. There was no significant difference between the groups in terms of the category distribution of PI. The DDH-OA group had lower mean sagittal femoral head coverage than the other groups. There were no significant correlations between PI and other anatomical factors, including sagittal femoral head coverage, α angle, and acetabular anteversion. Conclusion. No associations were found between mean PI values or PI categories and hip OA. Furthermore, there was no difference in PI between patients with primary OA and DDH-OA. From our evaluation, we found no evidence of PI being an independent factor associated with the development of hip OA. Cite this article: Bone Joint J 2021;103-B(11):1656–1661


Bone & Joint Open
Vol. 1, Issue 7 | Pages 364 - 369
10 Jul 2020
Aarvold A Lohre R Chhina H Mulpuri K Cooper A

Aims. Though the pathogenesis of Legg-Calve-Perthes disease (LCPD) is unknown, repetitive microtrauma resulting in deformity has been postulated. The purpose of this study is to trial a novel upright MRI scanner, to determine whether any deformation occurs in femoral heads affected by LCPD with weightbearing. Methods. Children affected by LCPD were recruited for analysis. Children received both standing weightbearing and supine scans in the MROpen upright MRI scanner, for coronal T1 GFE sequences, both hips in field of view. Parameters of femoral head height, width, and lateral extrusion of affected and unaffected hips were assessed by two independent raters, repeated at a one month interval. Inter- and intraclass correlation coefficients were determined. Standing and supine measurements were compared for each femoral head. Results. Following rigorous protocol development in healthy age-matched volunteers, successful scanning was performed in 11 LCPD-affected hips in nine children, with seven unaffected hips therefore available for comparison. Five hips were in early stage (1 and 2) and six were in late stage (3 and 4). The mean age was 5.3 years. All hips in early-stage LCPD demonstrated dynamic deformity on weightbearing. Femoral head height decreased (mean 1.2 mm, 12.4% decrease), width increased (mean 2.5 mm, 7.2% increase), and lateral extrusion increased (median 2.5 mm, 23% increase) on standing weightbearing MRI compared to supine scans. Negligible deformation was observed in contra-lateral unaffected hips, with less deformation observed in late-stage hips. Inter- and intraclass reliability for all measured parameters was good to excellent. Conclusion. This pilot study has described an effective novel research investigation for children with LCPD. Femoral heads in early-stage LCPD demonstrated dynamic deformity on weightbearing not previously seen, while unaffected hips did not. Expansion of this protocol will allow further translational study into the effects of loading hips with LCPD. Cite this article: Bone Joint Open 2020;1-7:364–369


Bone & Joint Open
Vol. 4, Issue 10 | Pages 735 - 741
2 Oct 2023
Galloway AM Pini S Holton C Perry DC Redmond A Siddle HJ Richards S

Aims. Perthes’ disease is an idiopathic avascular necrosis of the developing femoral head, often causing deformity that impairs physical function. Current treatments aim to optimize the joint reaction force across the hip by enhancing congruency between the acetabulum and femoral head. Despite a century of research, there is no consensus regarding the optimal treatment. The aim of this study was to describe the experiences of children, their families, and clinicians when considering the treatment of Perthes’ disease. Methods. A qualitative study gathered information from children and their families affected by Perthes’ disease, along with treating clinicians. Interviews followed a coding framework, with the interview schedule informed by behavioural theory and patient and public involvement. Transcripts were analyzed using the framework method. Results. A total of 24 interviews took place, with 12 child/family dyads and 12 clinicians from UK NHS centres. Interviews identified widespread variation of routine care. Children/their families recounted positive experiences when included in the decision-making process for treatment. There is a strong desire from clinicians and children/families for consistent guidance from everyone involved in care, which should be based on clinical consensus. Conclusion. This is the first study to describe how children/families and clinicians experienced receiving or providing treatment in Perthes’ disease. The results indicate the need for robust evidence to support treatment decisions. Children and families valued feeling involved in the clinical decision-making process. Clinicians acknowledged the central importance of providing patient-centred care, particularly in the absence of robust evidence to guide the optimal treatment decisions. This study will inform a future Delphi project to develop clinical consensus guidelines for the treatment of Perthes’ disease. Cite this article: Bone Jt Open 2023;4(10):735–741


The Bone & Joint Journal
Vol. 104-B, Issue 9 | Pages 1081 - 1088
1 Sep 2022
Behman AL Bradley CS Maddock CL Sharma S Kelley SP

Aims. There is no consensus regarding optimum timing and frequency of ultrasound (US) for monitoring response to Pavlik harness (PH) treatment in developmental dysplasia of the hip (DDH). The purpose of our study was to determine if a limited-frequency hip US assessment had an adverse effect on treatment outcomes compared to traditional comprehensive US monitoring. Methods. This study was a single-centre noninferiority randomized controlled trial. Infants aged under six months whose hips were reduced and centred in the harness at initiation of treatment (stable dysplastic or subluxable), or initially decentred (subluxated or dislocated) but reduced and centred within four weeks of PH treatment, were randomized to our current standard US monitoring protocol (every clinic visit) or to a limited-frequency US protocol (US only at end of treatment). Groups were compared based on α angle and femoral head coverage at the end of PH treatment, acetabular indices, and International Hip Dysplasia Institute (IHDI) grade on one-year follow-up radiographs. Results. Overall, 100 patients were included; 42 patients completed the standard protocol (SP) and 40 completed the limited protocol (LP). There was no significant difference in mean right α angle at the end of treatment (SP 70.0° (SD 3.2°) ; LP 68.7° (SD 2.9°); p = 0.033), nor on the left (SP 69.0° (SD 3.5°); LP 68.1° (SD 3.3°); p = 0.128). There was no significant difference in mean right acetabular index at follow-up (SP 23.1° (SD 4.3°); LP 22.0° (SD 4.1°); p = 0.129), nor on the left (SP 23.3° (SD 4.2°); LP 22.8° (SD 3.9°); p = 0.284). All hips had femoral head coverage of > 50% at end of treatment, and all were IHDI grade 1 at follow-up. In addition, the LP group underwent a 60% reduction in US use once stable. Conclusion. Our study supports reducing the frequency of US assessment during PH treatment of DDH once a hip is reduced and centred. Cite this article: Bone Joint J 2022;104-B(9):1081–1088


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 775 - 780
1 Jul 2022
Kołodziejczyk K Czubak-Wrzosek M Kwiatkowska M Czubak J

Aims. Developmental dysplasia of the hip (DDH) describes a pathological relationship between the femoral head and acetabulum. Periacetabular osteotomy (PAO) may be used to treat this condition. The aim of this study was to evaluate the results of PAO in adolescents and adults with persistent DDH. Methods. Patients were divided into four groups: A, adolescents who had not undergone surgery for DDH in childhood (25 hips); B, adolescents who had undergone surgery for DDH in childhood (20 hips); C, adults with DDH who had not undergone previous surgery (80 hips); and D, a control group of patients with healthy hips (70 hips). The radiological evaluation of digital anteroposterior views of hips included the Wiberg angle (centre-edge angle (CEA)), femoral head cover (FHC), medialization, distalization, and the ilioischial angle. Clinical assessment involved the Harris Hip Score (HHS) and gluteal muscle performance assessment. Results. Significant improvements in radiological parameters were achieved in all measurements in all groups (p < 0.05). The greatest improvement was in CEA (mean of 19° (17.2° to 22.3°) in Group B), medialization (mean of 3 mm (0.9 to 5.2) in Group C), distalization (mean of 6 mm (3.5 to 8.2) in Group B), FHC (mean of 17% (12.7% to 21.2%) in Group B), and ilioischial angle (mean of 5° (2.3° to 8.1°) in Group B). There were significant improvements in the mean HHS and gluteal muscle performance scores postoperatively in all three groups. Conclusion. The greatest correction of radiological parameters and clinical outcomes was found in patients who had undergone hip surgery in childhood. Although the surgical treatment of DDH in childhood makes subsequent hip surgery more difficult due to scarring, adhesions, and altered anatomy, it requires less correction of the deformity and has a beneficial effect on the outcome of PAO in adolescence and early adulthood. Cite this article: Bone Joint J 2022;104-B(7):775–780


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1345 - 1350
1 Aug 2021
Czubak-Wrzosek M Nitek Z Sztwiertnia P Czubak J Grzelecki D Kowalczewski J Tyrakowski M

Aims. The aim of the study was to compare two methods of calculating pelvic incidence (PI) and pelvic tilt (PT), either by using the femoral heads or acetabular domes to determine the bicoxofemoral axis, in patients with unilateral or bilateral primary hip osteoarthritis (OA). Methods. PI and PT were measured on standing lateral radiographs of the spine in two groups: 50 patients with unilateral (Group I) and 50 patients with bilateral hip OA (Group II), using the femoral heads or acetabular domes to define the bicoxofemoral axis. Agreement between the methods was determined by intraclass correlation coefficient (ICC) and the standard error of measurement (SEm). The intraobserver reproducibility and interobserver reliability of the two methods were analyzed on 31 radiographs in both groups to calculate ICC and SEm. Results. In both groups, excellent agreement between the two methods was obtained, with ICC of 0.99 and SEm 0.3° for Group I, and ICC 0.99 and SEm 0.4° for Group II. The intraobserver reproducibility was excellent for both methods in both groups, with an ICC of at least 0.97 and SEm not exceeding 0.8°. The study also revealed excellent interobserver reliability for both methods in both groups, with ICC 0.99 and SEm 0.5° or less. Conclusion. Either the femoral heads or acetabular domes can be used to define the bicoxofemoral axis on the lateral standing radiographs of the spine for measuring PI and PT in patients with idiopathic unilateral or bilateral hip OA. Cite this article: Bone Joint J 2021;103-B(8):1345–1350


Bone & Joint 360
Vol. 12, Issue 2 | Pages 42 - 44
1 Apr 2023

The April 2023 Research Roundup. 360. looks at: Ear protection for orthopaedic surgeons?; Has arthroscopic meniscectomy use changed in response to the evidence?; Time to positivity of cultures obtained for periprosthetic joint infection; Bisphosphonates for post-COVID-19 osteonecrosis of the femoral head; Missing missed fractures: is AI the answer?; Congenital insensitivity to pain and correction of the knee; YouTube and paediatric elbow injuries


Bone & Joint 360
Vol. 12, Issue 1 | Pages 17 - 20
1 Feb 2023

The February 2023 Hip & Pelvis Roundup. 360. looks at: Total hip arthroplasty or internal fixation for hip fracture?; Significant deterioration in quality of life and increased frailty in patients waiting more than six months for total hip or knee arthroplasty: a cross-sectional multicentre study; Long-term cognitive trajectory after total joint arthroplasty; Costal cartilage grafting for a large osteochondral lesion of the femoral head; Foley catheters not a problem in the short term; Revision hips still a mortality burden?; How to position implants with a robotic arm; Uncemented stems in hip fracture?


Bone & Joint 360
Vol. 12, Issue 4 | Pages 38 - 41
1 Aug 2023

The August 2023 Children’s orthopaedics Roundup. 360. looks at: DDH: What can patients expect after open reduction?; Femoral head deformity associated with hip displacement in non-ambulatory cerebral palsy; Bony hip reconstruction for displaced hips in patients with cerebral palsy: is postoperative immobilization indicated?; Opioid re-prescriptions after ACL reconstruction in adolescents are associated with subsequent opioid use disorder; Normative femoral and tibial lengths in a modern population of USA children; Retrospective analysis of associated anomalies in 636 patients with operatively treated congenital scoliosis; Radiological hip shape and patient-reported outcome measures in healed Perthes’ disease; Significantly displaced adolescent posterior sternoclavicular joint injuries


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 838 - 844
1 Jul 2020
Chen L Hong G Hong Z Lin T Chen Z Zhang Q He W

Aims. The aim of this study was to report the medium-term outcomes of impaction bone allograft and fibular grafting for osteonecrosis of the femoral head (ONFH) and to define the optimal indications. Methods. A total of 67 patients (77 hips) with ONFH were enrolled in a single centre retrospective review. Success of the procedure was assessed using the Harris Hip Score (HHS) and rate of revision to total hip arthroplasty (THA). Risk factors were studied, including age, aetiology, duration of hip pain, as well as two classification systems (Association Research Circulation Osseous (ARCO) and Japanese Investigation Committee (JIC) systems). Results. After a mean follow-up period of 8.61 years (SD 1.45), 81.3% (52/64) of enrolled cases had a good or excellent HHS at latest follow-up (declining to 76.0% (38/50) for those with more than eight years of follow-up). Overall survival was 92.1% at eight years’ follow-up (95% CI 83.2% to 96.4%). A total of 12 hips (19.0%) failed (reoperation or HHS < 70 points) at final follow-up. Rate of success was adversely affected by increasing age, duration of pain, and more severe disease as measured using the ARCO and JIC classifications, but not by aetiology of the ONFH. Conclusion. We report favourable medium-term results of this procedure. Best outcomes can be expected in patients matching the following indications: younger than 40 years; less 12-month hip pain before surgery; femoral head collapse being less than 2 mm; and integrated lateral wall of femoral head. Cite this article: Bone Joint J 2020;102-B(7):838–844


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 198 - 203
1 Jan 2021
Min JJ Kwon S Sung KH Lee KM Chung CY Park MS

Aims. Hip displacement, common in patients with cerebral palsy (CP), causes pain and hinders adequate care. Hip reconstructive surgery (HRS) is performed to treat hip displacement; however, only a few studies have quantitatively assessed femoral head sphericity after HRS. The aim of this study was to quantitatively assess improvement in hip sphericity after HRS in patients with CP. Methods. We retrospectively analyzed hip radiographs of patients who had undergone HRS because of CP-associated hip displacement. The pre- and postoperative migration percentage (MP), femoral neck-shaft angle (NSA), and sphericity, as determined by the Mose hip ratio (MHR), age at surgery, Gross Motor Function Classification System level, surgical history including Dega pelvic osteotomy, and triradiate cartilage status were studied. Regression analyses using linear mixed model were performed to identify factors affecting hip sphericity improvement. Results. A total of 108 patients were enrolled. The mean preoperative MP was 58.3% (SD 31.7%), which improved to 9.1% (SD 15.6%) at the last follow-up. NSA and MHR improved from 156.5° (SD 11.5°) and 82.3% (SD 8.6%) to 126.0° (SD 18.5°) and 89.1% (SD 9.0%), respectively. Factors affecting the postoperative MHR were preoperative MP (p = 0.005), immediate postoperative MP (p = 0.032), and history of Dega osteotomy (p = 0.046). Conclusion. We found that hip sphericity improves with HRS. Preoperative MP, reduction quality, and acetabular coverage influence femoral head remodelling. We recommend that surgeons should consider intervention early before hip displacement progresses and that during HRS, definite reduction and coverage of the femoral head should be obtained. Cite this article: Bone Joint J 2021;103-B(1):198–203


Bone & Joint Open
Vol. 5, Issue 1 | Pages 3 - 8
2 Jan 2024
Husum H Hellfritzsch MB Maimburg RD Møller-Madsen B Henriksen M Lapitskaya N Kold S Rahbek O

Aims. The present study seeks to investigate the correlation of pubofemoral distances (PFD) to α angles, and hip displaceability status, defined as femoral head coverage (FHC) or FHC during manual provocation of the newborn hip < 50%. Methods. We retrospectively included all newborns referred for ultrasound screening at our institution based on primary risk factor, clinical, and PFD screening. α angles, PFD, FHC, and FHC at follow-up ultrasound for referred newborns were measured and compared using scatter plots, linear regression, paired t-test, and box-plots. Results. We included 2,735 newborns, of whom 754 received a follow-up hip ultrasound within six weeks of age. After exclusion, 1,500 hips were included for analysis. Sex distribution was 372 male and 380 female, and the mean age at examination was 36.6 days (4 to 87). We found a negative linear correlation of PFD to α angles (p < 0.001), FHC (p < 0.001), and FHC during provocation (p < 0.001) with a 1 mm increase in PFD corresponding to a -2.1° (95% confidence interval (CI) -2.3 to -1.9) change in α angle and a -3.4% (95% CI -3.7 to -3.0) change in FHC and a -6.0% (-6.6 to -5.5) change in FHC during provocation. The PFD was significantly higher with increasing Graf types and in displaceable hips (p < 0.001). Conclusion. PFD is strongly correlated to both α angles and hip displaceability, as measured by FHC and FHC during provocation, in ultrasound of newborn hips. The PFD increases as the hips become more dysplastic and/or displaceable. Cite this article: Bone Jt Open 2023;5(1):3–8


Bone & Joint Research
Vol. 8, Issue 10 | Pages 451 - 458
1 Oct 2019
Kuroda Y Tanaka T Miyagawa T Kawai T Goto K Tanaka S Matsuda S Akiyama H

Objectives. Using a simple classification method, we aimed to estimate the collapse rate due to osteonecrosis of the femoral head (ONFH) in order to develop treatment guidelines for joint-preserving surgeries. Methods. We retrospectively analyzed 505 hips from 310 patients (141 men, 169 women; mean age 45.5 years . (sd. 14.9; 15 to 86)) diagnosed with ONFH and classified them using the Japanese Investigation Committee (JIC) classification. The JIC system includes four visualized types based on the location and size of osteonecrotic lesions on weightbearing surfaces (types A, B, C1, and C2) and the stage of ONFH. The collapse rate due to ONFH was calculated using Kaplan–Meier survival analysis, with radiological collapse/arthroplasty as endpoints. Results. Bilateral cases accounted for 390 hips, while unilateral cases accounted for 115. According to the JIC types, 21 hips were type A, 34 were type B, 173 were type C1, and 277 were type C2. At initial diagnosis, 238/505 hips (47.0%) had already collapsed. Further, the cumulative survival rate was analyzed in 212 precollapsed hips, and the two-year and five-year collapse rates were found to be 0% and 0%, 7.9% and 7.9%, 23.2% and 36.6%, and 57.8% and 84.8% for types A, B, C1, and C2, respectively. Conclusion. Type A ONFH needs no further treatment, but precollapse type C2 ONFH warrants immediate treatment with joint-preserving surgery. Considering the high collapse rate, our study results justify the importance of early diagnosis and intervention in asymptomatic patients with type C2 ONFH. Cite this article: Y. Kuroda, T. Tanaka, T. Miyagawa, T. Kawai, K. Goto, S. Tanaka, S. Matsuda, H. Akiyama. Classification of osteonecrosis of the femoral head: Who should have surgery?. Bone Joint Res 2019;8:451–458. DOI: 10.1302/2046-3758.810.BJR-2019-0022.R1


Bone & Joint Open
Vol. 3, Issue 11 | Pages 877 - 884
14 Nov 2022
Archer H Reine S Alshaikhsalama A Wells J Kohli A Vazquez L Hummer A DiFranco MD Ljuhar R Xi Y Chhabra A

Aims. Hip dysplasia (HD) leads to premature osteoarthritis. Timely detection and correction of HD has been shown to improve pain, functional status, and hip longevity. Several time-consuming radiological measurements are currently used to confirm HD. An artificial intelligence (AI) software named HIPPO automatically locates anatomical landmarks on anteroposterior pelvis radiographs and performs the needed measurements. The primary aim of this study was to assess the reliability of this tool as compared to multi-reader evaluation in clinically proven cases of adult HD. The secondary aims were to assess the time savings achieved and evaluate inter-reader assessment. Methods. A consecutive preoperative sample of 130 HD patients (256 hips) was used. This cohort included 82.3% females (n = 107) and 17.7% males (n = 23) with median patient age of 28.6 years (interquartile range (IQR) 22.5 to 37.2). Three trained readers’ measurements were compared to AI outputs of lateral centre-edge angle (LCEA), caput-collum-diaphyseal (CCD) angle, pelvic obliquity, Tönnis angle, Sharp’s angle, and femoral head coverage. Intraclass correlation coefficients (ICC) and Bland-Altman analyses were obtained. Results. Among 256 hips with AI outputs, all six hip AI measurements were successfully obtained. The AI-reader correlations were generally good (ICC 0.60 to 0.74) to excellent (ICC > 0.75). There was lower agreement for CCD angle measurement. Most widely used measurements for HD diagnosis (LCEA and Tönnis angle) demonstrated good to excellent inter-method reliability (ICC 0.71 to 0.86 and 0.82 to 0.90, respectively). The median reading time for the three readers and AI was 212 (IQR 197 to 230), 131 (IQR 126 to 147), 734 (IQR 690 to 786), and 41 (IQR 38 to 44) seconds, respectively. Conclusion. This study showed that AI-based software demonstrated reliable radiological assessment of patients with HD with significant interpretation-related time savings. Cite this article: Bone Jt Open 2022;3(11):877–884


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 352 - 358
1 Apr 2024
Wilson JM Trousdale RT Bedard NA Lewallen DG Berry DJ Abdel MP

Aims. Dislocation remains a leading cause of failure following revision total hip arthroplasty (THA). While dual-mobility (DM) bearings have been shown to mitigate this risk, options are limited when retaining or implanting an uncemented shell without modular DM options. In these circumstances, a monoblock DM cup, designed for cementing, can be cemented into an uncemented acetabular shell. The goal of this study was to describe the implant survival, complications, and radiological outcomes of this construct. Methods. We identified 64 patients (65 hips) who had a single-design cemented DM cup cemented into an uncemented acetabular shell during revision THA between 2018 and 2020 at our institution. Cups were cemented into either uncemented cups designed for liner cementing (n = 48; 74%) or retained (n = 17; 26%) acetabular components. Median outer head diameter was 42 mm. Mean age was 69 years (SD 11), mean BMI was 32 kg/m. 2. (SD 8), and 52% (n = 34) were female. Survival was assessed using Kaplan-Meier methods. Mean follow-up was two years (SD 0.97). Results. There were nine cemented DM cup revisions: three for periprosthetic joint infection, three for acetabular aseptic loosening from bone, two for dislocation, and one for a broken cup-cage construct. The two-year survivals free of aseptic DM revision and dislocation were both 92%. There were five postoperative dislocations, all in patients with prior dislocation or abductor deficiency. On radiological review, the DM cup remained well-fixed at the cemented interface in all but one case. Conclusion. While dislocation was not eliminated in this series of complex revision THAs, this technique allowed for maximization of femoral head diameter and optimization of effective acetabular component position during cementing. Of note, there was only one failure at the cemented interface. Cite this article: Bone Joint J 2024;106-B(4):352–358


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 29 - 34
1 Jan 2023
Fransen BL Bengoa FJ Neufeld ME Sheridan GA Garbuz DS Howard LC

Aims. Several short- and mid-term studies have shown minimal liner wear of highly cross-linked polyethylene (HXLPE) in total hip arthroplasty (THA), but the safety of using thinner HXLPE liners to maximize femoral head size remains uncertain. The objective of this study was to analyze clinical survival and radiological wear rates of patients with HXLPE liners, a 36 mm femoral head, and a small acetabular component with a minimum of ten years’ follow-up. Methods. We retrospectively identified 55 patients who underwent primary THA performed at a single centre, using HXLPE liners with 36 mm cobalt-chrome heads in acetabular components with an outer diameter of 52 mm or smaller. Patient demographic details, implant details, death, and all-cause revisions were recorded. Cox regression and Kaplan-Meier survival was used to determine all-cause and liner-specific revision. Of these 55 patients, 22 had a minimum radiological follow-up of seven years and were assessed radiologically for linear and volumetric wear. Results. Overall survival rate for all-cause revision was 94.5% (95% confidence interval (CI) 81.7% to 97.2%) at a mean follow-up of 12.8 years (10.9 to 18.7). Three patients were revised, none for liner wear, fracture, or dissociation. A total of 22 patients were included in the radiological analysis (mean follow-up 9.9 years (7.5 to 13.7)). Mean linear liner wear was 0.085 mm (95% CI -0.086 to 0.257) and the volumetric wear rate was 11.097 mm. 3. /year (95% CI -6.5 to 28.7). Conclusion. Using HXLPE liners with 36 mm heads in 52 mm acetabular components or smaller is safe, with excellent survival and low rates of linear and volumetric wear at medium-term follow-up. Patients did not require revision surgery for liner complications such as fracture, dissociation, or wear. Our results suggest that the advantages of using larger heads outweigh the potential risks of using thin HXLPE liners. Cite this article: Bone Joint J 2023;105-B(1):29–34


Bone & Joint Open
Vol. 3, Issue 11 | Pages 913 - 923
28 Nov 2022
Hareendranathan AR Wichuk S Punithakumar K Dulai S Jaremko J

Aims. Studies of infant hip development to date have been limited by considering only the changes in appearance of a single ultrasound slice (Graf’s standard plane). We used 3D ultrasound (3DUS) to establish maturation curves of normal infant hip development, quantifying variation by age, sex, side, and anteroposterior location in the hip. Methods. We analyzed 3DUS scans of 519 infants (mean age 64 days (6 to 111 days)) presenting at a tertiary children’s hospital for suspicion of developmental dysplasia of the hip (DDH). Hips that did not require ultrasound follow-up or treatment were classified as ‘typically developing’. We calculated traditional DDH indices like α angle (α. SP. ), femoral head coverage (FHC. SP. ), and several novel indices from 3DUS like the acetabular contact angle (ACA) and osculating circle radius (OCR) using custom software. Results. α angle, FHC, and ACA indices increased and OCR decreased significantly by age in the first four months, mean α. SP. rose from 62.2° (SD 5.7°) to 67.3° (SD 5.2°) (p < 0.001) in one- to eight- and nine- to 16-week-old infants, respectively. Mean α. SP. and mean FHC. SP. were significantly, but only slightly, lower in females than in males. There was no statistically significant difference in DDH indices observed between left and right hip. All 3DUS indices varied significantly between anterior and posterior section of the hip. Mean 3D indices of α angle and FHC were significantly lower anteriorly than posteriorly: α. Ant. = 58.2° (SD 6.1°), α. Post. = 63.8° (SD 6.3°) (p < 0.001), FHC. Ant. = 43.0 (SD 7.4), and FHC. Post. = 55.4° (SD 11.2°) (p < 0.001). Acetabular rounding measured byOCR indices was significantly greater in the anterior section of the hip (p < 0.001). Conclusion. We used 3DUS to show that hip shape and normal growth pattern vary significantly between anterior and posterior regions, by magnitudes similar to age-related changes. This highlights the need for careful selection of the Graf plane during 2D ultrasound examination. Whole-joint evaluation by obtaining either 3DUS or manual ‘sweep’ video images provides more comprehensive DDH assessment. Cite this article: Bone Jt Open 2022;3(11):913–923