Advertisement for orthosearch.org.uk
Results 21 - 40 of 44
Results per page:
The Bone & Joint Journal
Vol. 100-B, Issue 1 | Pages 109 - 118
1 Jan 2018
Talbot C Davis N Majid I Young M Bouamra O Lecky FE Jones S

Aims

The aim of this study was to describe the epidemiology of closed isolated fractures of the femoral shaft in children, and to compare the treatment and length of stay (LOS) between major trauma centres (MTCs) and trauma units (TUs) in England.

Patients and Methods

National data were obtained from the Trauma and Audit Research Network for all isolated, closed fractures of the femoral shaft in children from birth to 15 years of age, between 2012 and 2015. Age, gender, the season in which the fracture occurred, non-accidental injury, the mechanism of injury, hospital trauma status, LOS and type of treatment were recorded.


Bone & Joint 360
Vol. 5, Issue 1 | Pages 2 - 8
1 Feb 2016
Bryson D Shivji F Price K Lawniczak D Chell J Hunter J


Bone & Joint Research
Vol. 5, Issue 4 | Pages 116 - 121
1 Apr 2016
Leow JM Clement ND Tawonsawatruk T Simpson CJ Simpson AHRW

Objectives

The radiographic union score for tibial (RUST) fractures was developed by Whelan et al to assess the healing of tibial fractures following intramedullary nailing. In the current study, the repeatability and reliability of the RUST score was evaluated in an independent centre (a) using the original description, (b) after further interpretation of the description of the score, and (c) with the immediate post-operative radiograph available for comparison.

Methods

A total of 15 radiographs of tibial shaft fractures treated by intramedullary nailing (IM) were scored by three observers using the RUST system. Following discussion on how the criteria of the RUST system should be implemented, 45 sets (i.e. AP and lateral) of radiographs of IM nailed tibial fractures were scored by five observers. Finally, these 45 sets of radiographs were rescored with the baseline post-operative radiograph available for comparison.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 11 | Pages 1592 - 1595
1 Nov 2010
Ahmed I Robinson CM Patton JT Cook RE

We present two cases of metastatic lung cancer which occurred at the site of a previously united tibial fracture. Both patients were treated with a locked intramedullary nail. The patients presented with metastases at the site of their initial fracture approximately 16 and 13 months after injury respectively.

We discuss this unusual presentation and review the relevant literature. We are unaware of any previous reports of a metastatic tumour occurring at the site of an orthopaedic implant used to stabilise a non-pathological fracture. These cases demonstrate the similar clinical presentation of infection and malignancy: a diagnosis which should always be considered in such patients.


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1299 - 1311
1 Oct 2016
Hong CC Pearce CJ Ballal MS Calder JDF

Injuries to the foot in athletes are often subtle and can lead to a substantial loss of function if not diagnosed and treated appropriately. For these injuries in general, even after a diagnosis is made, treatment options are controversial and become even more so in high level athletes where limiting the time away from training and competition is a significant consideration.

In this review, we cover some of the common and important sporting injuries affecting the foot including updates on their management and outcomes.

Cite this article: Bone Joint J 2016;98-B:1299–1311.


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1472 - 1477
1 Nov 2014
Vioreanu MH Parry MC Haddad FS Duncan CP

The Unified Classification System (UCS) emphasises the key principles in the assessment and management of peri-prosthetic fractures complicating partial or total joint replacement.

We tested the inter- and intra-observer agreement for the UCS as applied to the pelvis and femur using 20 examples of peri-prosthetic fracture in 17 patients. Each subtype of the UCS was represented by at least one case. Specialist orthopaedic surgeons (experts) and orthopaedic residents (pre-experts) assessed reliability on two separate occasions.

For the pelvis, the UCS showed inter-observer agreement of 0.837 (95% confidence intervals (CI) 0.798 to 0.876) for the experts and 0.728 (95% CI 0.689 to 0.767) for the pre-experts. The intra-observer agreement for the experts was 0.861 (95% CI 0.760 to 0.963) and 0.803 (95% 0.688 to 0.918) for the pre-experts. For the femur, the UCS showed an inter-observer kappa value of 0.805 (95% CI 0.765 to 0.845) for the experts and a value of 0.732 (95% CI 0.690 to 0.773) for the pre-experts. The intra-observer agreement was 0.920 (95% CI 0.867 to 0.973) for the experts, and 0.772 (95% CI 0.652 to 0.892) for the pre-experts. This corresponds to a substantial and ‘almost perfect’ inter- and intra-observer agreement for the UCS for peri-prosthetic fractures of the pelvis and femur.

We hope that unifying the terminology of these injuries will assist in their assessment, treatment and outcome.

Cite this article: Bone Joint J 2014;96-B:1472–7.


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 48 - 55
1 Nov 2014
Yasen AT Haddad FS

We are currently facing an epidemic of periprosthetic fractures around the hip. They may occur either during surgery or post-operatively. Although the acetabulum may be involved, the femur is most commonly affected. We are being presented with new, difficult fracture patterns around cemented and cementless implants, and we face the challenge of an elderly population who may have grossly deficient bone and may struggle to rehabilitate after such injuries. The correct surgical management of these fractures is challenging. This article will review the current choices of implants and techniques available to deal with periprosthetic fractures of the femur.

Cite this article: Bone Joint J 2014;96-B(11 Suppl A):48–55.


Bone & Joint 360
Vol. 5, Issue 1 | Pages 16 - 18
1 Feb 2016


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1424 - 1430
1 Nov 2009
Corten K Vanrykel F Bellemans J Frederix PR Simon J Broos PLO

The use of plate-and-cable constructs to treat periprosthetic fractures around a well-fixed femoral component in total hip replacements has been reported to have high rates of failure. Our aim was to evaluate the results of a surgical treatment algorithm to use these lateral constructs reliably in Vancouver type-B1 and type-C fractures. The joint was dislocated and the stability of the femoral component was meticulously evaluated in 45 type-B1 fractures. This led to the identification of nine (20%) unstable components. The fracture was considered to be suitable for single plate-and-cable fixation by a direct reduction technique if the integrity of the medial cortex could be restored.

Union was achieved in 29 of 30 fractures (97%) at a mean of 6.4 months (3 to 30) in 29 type-B1 and five type-C fractures. Three patients developed an infection and one construct failed.

Using this algorithm plate-and-cable constructs can be used safely, but indirect reduction with minimal soft-tissue damage could lead to shorter times to union and lower rates of complications.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1469 - 1473
1 Nov 2006
Ekholm R Adami J Tidermark J Hansson K Törnkvist H Ponzer S

We studied the epidemiology of 401 fractures of the shaft of the humerus in 397 patients aged 16 years or older. The incidence was 14.5 per 100 000 per year with a gradually increasing age-specific incidence from the fifth decade, reaching almost 60 per 100 000 per year in the ninth decade. Most were closed fractures in elderly patients which had been sustained as the result of a simple fall. The age distribution in women was characterised by a peak in the eighth decade while that in men was more even. Simple fractures were by far the most common and most were located in the middle or proximal shaft. The incidence of palsy of the radial nerve was 8% and fractures in the middle and distal shaft were most likely to be responsible. Only 2% of the fractures were open and 8% were pathological. These figures are representative of a population with a low incidence of high-energy and penetrating trauma, which probably reflects the situation in most European countries.


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 461 - 467
1 Apr 2016
Abdel MP Watts CD Houdek MT Lewallen DG Berry DJ

Aim and Methods

The goals of this study were to define the risk factors, nature, chronology, and treatment strategies adopted for periprosthetic femoral fractures in 32 644 primary total hip arthroplasties (THAs).

Results

There were 564 intra-operative fractures (1.7%); 529 during uncemented stem placement (3.0%) and 35 during cemented stem placement (0.23%). Intra-operative fractures were more common in females and patients over 65 years (p < 0.001). The majority occurred during placement of the femoral component (60%), and involved the calcar (69%). There were 557 post-operative fractures (20-year probability: 3.5%; 95% confidence interval (CI) 3.2 to 3.9); 335 fractures after placement of an uncemented stem (20-year probability: 7.7%; 95% CI 6.2 to 9.1) and 222 after placement of a cemented stem (20-year probability: 2.1%; 95% CI 1.8 to 2.5). The probability of a post-operative fracture within 30 days after an uncemented stem was ten times higher than a cemented stem. The most common post-operative fracture type was a Vancouver AG (32%; n = 135), with 67% occurring after a fall. In all, 36% (n = 152) were treated with revision arthroplasty.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 999 - 1000
1 Jul 2011
Khanduja V


Bone & Joint Research
Vol. 1, Issue 6 | Pages 104 - 110
1 Jun 2012
Swinteck BJ Phan DL Jani J Owen JR Wayne JS Mounasamy V

Objectives

The use of two implants to manage concomitant ipsilateral femoral shaft and proximal femoral fractures has been indicated, but no studies address the relationship of dynamic hip screw (DHS) side plate screws and the intramedullary nail where failure might occur after union. This study compares different implant configurations in order to investigate bridging the gap between the distal DHS and tip of the intramedullary nail.

Methods

A total of 29 left synthetic femora were tested in three groups: 1) gapped short nail (GSN); 2) unicortical short nail (USN), differing from GSN by the use of two unicortical bridging screws; and 3) bicortical long nail (BLN), with two angled bicortical and one unicortical bridging screws. With these findings, five matched-pairs of cadaveric femora were tested in two groups: 1) unicortical long nail (ULN), with a longer nail than USN and three bridging unicortical screws; and 2) BLN. Specimens were axially loaded to 22.7 kg (50 lb), and internally rotated 90°/sec until failure.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 6 | Pages 821 - 824
1 Jun 2007
Ogawa BK Kay RM Choi PD Stevanovic MV

The management of closed fractures of the humerus with an associated nerve palsy remains controversial. With very little written about this injury in children, we present the case of a three-year-old child with a closed humeral shaft fracture in whom surgical exploration and reconstruction of the radial nerve with a sural nerve graft was performed three months after injury. The child regained full function. To the best of our knowledge, this is the first such case to be reported in the English literature.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 189 - 195
1 Feb 2010
Jayakumar P Barry M Ramachandran M

Non-accidental injury (NAI) in children includes orthopaedic trauma throughout the skeleton. Fractures with soft-tissue injuries constitute the majority of manifestations of physical abuse in children. Fracture and injury patterns vary with age and development, and NAI is intrinsically related to the mobility of the child. No fracture in isolation is pathognomonic of NAI, but specific abuse-related injuries include multiple fractures, particularly at various stages of healing, metaphyseal corner and bucket-handle fractures and fractures of ribs. Isolated or multiple rib fractures, irrespective of location, have the highest specificity for NAI. Other fractures with a high specificity for abuse include those of the scapula, lateral end of the clavicle, vertebrae and complex skull fractures.

Injuries caused by NAI constitute a relatively small proportion of childhood fractures. They may be associated with significant physical and psychological morbidity, with wide- ranging effects from deviations in normal developmental progression to death.

Orthopaedic surgeons must systematically assess, recognise and act on the indicators for NAI in conjunction with the paediatric multidisciplinary team.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 486 - 489
1 Apr 2007
Bassi RS Simmons D Ali F Nuttall D Birch A Trail IA Stanley JK

The Acclaim total elbow replacement is a modular system which allows implantation in both unlinked and linked modes. The results of the use of this implant in primary total elbow replacement in 36 patients, operated on between July 2000 and August 2002, are presented at a mean follow-up of 36 months (24 to 49). Only one patient did not have good relief of pain, but all had improved movement and function.

No implant showed clinical or radiological loosening, although one had a lucent area in three of seven humeral zones. The short-term results of the Acclaim total elbow replacement are encouraging. However, 11 patients (30.5%) suffered an intra-operative fracture of the humeral condyle. This did not affect the outcome, or the requirement for further surgery, except in one case where the fracture failed to unite. This problem has hopefully been addressed by redesigning the humeral resection guide. Other complications included three cases of ulnar neuropathy (8.3%) and one of deep infection (2.8%).


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 4 | Pages 430 - 435
1 Apr 2008
Biant LC Bruce WJM Assini JB Walker PM Walsh WR

This prospective study presents the ten-year (5 to 16) clinical and radiological results of 55 primary total hip replacements (THR) using a cementless modular femoral component (S-ROM). All patients had a significant anatomical abnormality which rendered the primary THR difficult.

The mean Harris hip score was 36 (12 to 72) pre-operatively, 83 (44 to 100) at five years, and 85 (45 to 99) at ten years. The Western Ontario and McMaster Universities osteoarthritis index (WOMAC) and short-form (SF)-12 scores were recorded from the year 2000. The mean SF-12 score at five years after surgery was 45.24 (22.74 to 56.58) for the physical component and 54.14 (29.20 to 66.61) for the mental component. By ten years the SF-12 scores were 42.86 (21.59 to 58.95) and 51.03 (33.78 to 61.40), respectively. The mean WOMAC score at five years post-operatively was 25 (0 to 59), and at ten years was 27 (2 to 70).

No femoral components were radiologically loose, although five had osteolysis in Gruen zone 1, three had osteolysis in zone 7, and two showed osteolysis in both zones 1 and 7. No osteolysis was observed around or distal to the prosthetic sleeve. No femoral components were revised, although three hips underwent an acetabular revision and two required a liner exchange. At a mean of ten years’ follow-up the S-ROM femoral component implanted for an anatomically difficult primary THR has excellent clinical and radiological results.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 4 | Pages 405 - 410
1 Apr 2008
Dattani R Patnaik S Kantak A Srikanth B Selvan TP

The management of injury to the distal tibiofibular syndesmosis remains controversial in the treatment of ankle fractures. Operative fixation usually involves the insertion of a metallic diastasis screw. There are a variety of options for the position and characterisation of the screw, the type of cortical fixation, and whether the screw should be removed prior to weight-bearing. This paper reviews the relevant anatomy, the clinical and radiological diagnosis and the mechanism of trauma and alternative methods of treatment for injuries to the syndesmosis.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 449 - 454
1 Apr 2007
Kim Y Kim J Yoon S

We studied prospectively the long-term results of the Charnley Elite-Plus femoral stem in 184 consecutive young patients (194 hips). There were 130 men and 54 women with a mean age of 49.1 years (21 to 60). The predominant diagnosis was osteonecrosis of the femoral head (63.6%, 117 patients). Clinical and radiological evaluation was undertaken at each follow-up. The mean follow-up was 11.2 years (10 to 12).

The mean pre-operative Harris hip score was 43.4 (12 to 49) which improved to 91 (59 to 100) at the final follow-up. The survival of the femoral stem at 12 years was 99% with revision as the end-point. The mean annual linear wear of the polyethylene liner was 0.17 mm (0.13 to 0.22). The prevalence of acetabular osteolysis was 10.8% (21 hips) and osteolysis of the calcar femorale 12.9% (25 hips).

A third-generation cementing technique, accurate alignment of the stem and the use of a 22 mm zirconia head were important factors in the prevention of aseptic loosening of the Elite Plus femoral stem in these high-risk young patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 5 | Pages 586 - 591
1 May 2006
Wang J Fong C Su Y Yu H

Failure of total hip arthroplasty with acetabular deficiency occurred in 55 patients (60 hips) and was treated with acetabular revision using morsellised allograft and a cemented metal-backed component. A total of 50 patients (55 hips) were available for clinical and radiological evaluation at a mean follow-up of 5.8 years (3 to 9.5). No hip required further revision of the acetabular component because of aseptic loosening.

All the hips except one had complete incorporation of the allograft demonstrated on the radiographs. A complete radiolucent line of > 1 mm was noted in two hips post-operatively. A good to excellent result occurred in 50 hips (91%). With radiological evidence of aseptic loosening of the acetabular component as the end-point, the survivorship at a mean of 5.8 years after surgery was 96.4%.

The use of impacted allograft chips in combination with a cemented metal-backed acetabular component and screw fixation can achieve good medium-term results in patients with acetabular bone deficiency.