Advertisement for orthosearch.org.uk
Results 21 - 40 of 932
Results per page:
The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 57 - 61
1 Jun 2019
Chalmers BP Mangold DG Hanssen AD Pagnano MW Trousdale RT Abdel MP

Aims. Modular dual-mobility constructs reduce the risk of dislocation after revision total hip arthroplasty (THA). However, questions about metal ions from the cobalt-chromium (CoCr) liner persist, and are particularly germane to patients being revised for adverse local tissue reactions (ALTR) to metal. We determined the early- to mid-term serum Co and Cr levels after modular dual-mobility components were used in revision and complex primary THAs, and specifically included patients revised for ALTR. Patients and Methods. Serum Co and Cr levels were measured prospectively in 24 patients with a modular dual-mobility construct and a ceramic femoral head. Patients with CoCr heads or contralateral THAs with CoCr heads were excluded. The mean age was 63 years (35 to 83), with 13 patients (54%) being female. The mean follow-up was four years (2 to 7). Indications for modular dual-mobility were prosthetic joint infection treated with two-stage exchange and subsequent reimplantation (n = 8), ALTR revision (n = 7), complex primary THA (n = 7), recurrent instability (n = 1), and periprosthetic femoral fracture (n = 1). The mean preoperative Co and Cr in patients revised for an ALTR were 29.7 μg/l (2 to 146) and 21.5 μg/l (1 to 113), respectively. Results. Mean Co and Cr levels were 0.30 μg/l and 0.76 μg/l, respectively, at the most recent follow-up. No patient had a Co level ≥ 1 μg/l. Only one patient had a Cr level ≥ 1 μg/l. That patient’s Cr level was 12 μg/l at 57 months after revision THA for ALTR (and decreased ten-fold from a preoperative Cr of 113 μg/l). Conclusion. At a mean of four years, no patient with a modular dual-mobility construct and ceramic femoral head had elevated Co levels, including seven patients revised specifically for ALTR. While further studies are required, we support the selective use of a modular dual-mobility construct in revision and complex primary THAs for patients at high risk for instability. Cite this article: Bone Joint J 2019;101-B(6 Supple B):57–61


Bone & Joint Research
Vol. 12, Issue 10 | Pages 644 - 653
10 Oct 2023
Hinz N Butscheidt S Jandl NM Rohde H Keller J Beil FT Hubert J Rolvien T

Aims. The management of periprosthetic joint infection (PJI) remains a major challenge in orthopaedic surgery. In this study, we aimed to characterize the local bone microstructure and metabolism in a clinical cohort of patients with chronic PJI. Methods. Periprosthetic femoral trabecular bone specimens were obtained from patients suffering from chronic PJI of the hip and knee (n = 20). Microbiological analysis was performed on preoperative joint aspirates and tissue specimens obtained during revision surgery. Microstructural and cellular bone parameters were analyzed in bone specimens by histomorphometry on undecalcified sections complemented by tartrate-resistant acid phosphatase immunohistochemistry. Data were compared with control specimens obtained during primary arthroplasty (n = 20) and aseptic revision (n = 20). Results. PJI specimens exhibited a higher bone volume, thickened trabeculae, and increased osteoid parameters compared to both control groups, suggesting an accelerated bone turnover with sclerotic microstructure. On the cellular level, osteoblast and osteoclast parameters were markedly increased in the PJI cohort. Furthermore, a positive association between serum (CRP) but not synovial (white blood cell (WBC) count) inflammatory markers and osteoclast indices could be detected. Comparison between different pathogens revealed increased osteoclastic bone resorption parameters without a concomitant increase in osteoblasts in bone specimens from patients with Staphylococcus aureus infection, compared to those with detection of Staphylococcus epidermidis and Cutibacterium spp. Conclusion. This study provides insights into the local bone metabolism in chronic PJI, demonstrating osteosclerosis with high bone turnover. The fact that Staphylococcus aureus was associated with distinctly increased osteoclast indices strongly suggests early surgical treatment to prevent periprosthetic bone alterations. Cite this article: Bone Joint Res 2023;12(10):644–653


Bone & Joint Research
Vol. 13, Issue 10 | Pages 546 - 558
4 Oct 2024
Li Y Wuermanbieke S Wang F Mu W Ji B Guo X Zou C Chen Y Zhang X Cao L

Aims. The optimum type of antibiotics and their administration route for treating Gram-negative (GN) periprosthetic joint infection (PJI) remain controversial. This study aimed to determine the GN bacterial species and antibacterial resistance rates related to clinical GN-PJI, and to determine the efficacy and safety of intra-articular (IA) antibiotic injection after one-stage revision in a GN pathogen-induced PJI rat model of total knee arthroplasty. Methods. A total of 36 consecutive PJI patients who had been infected with GN bacteria between February 2015 and December 2021 were retrospectively recruited in order to analyze the GN bacterial species involvement and antibacterial resistance rates. Antibiotic susceptibility assays of the GN bacterial species were performed to screen for the most sensitive antibiotic, which was then used to treat the most common GN pathogen-induced PJI rat model. The rats were randomized either to a PJI control group or to three meropenem groups (intraperitoneal (IP), IA, and IP + IA groups). After two weeks of treatment, infection control level, the side effects, and the volume of antibiotic use were evaluated. Results. Escherichia coli was the most common pathogen in GN-PJI, and meropenem was the most sensitive antibiotic. Serum inflammatory markers, weightbearing activity, and Rissing score were significantly improved by meropenem, especially in the IA and IP + IA groups ( p < 0.05). Meropenem in the IA group eradicated E. coli from soft-tissue, bone, and prosthetic surfaces, with the same effect as in the IP + IA group. Radiological results revealed that IA and IP + IA meropenem were effective at relieving bone damage. Haematoxylin and eosin staining also showed that IA and IP + IA meropenem improved synovial inflammation and bone destruction. No pathological changes in the main organs or abnormal serum markers were observed in any of the meropenem-treated rats. The IA group required the lowest amount of meropenem, followed by the IP and IP + IA groups. Conclusion. IA-only meropenem with a two-week treatment course was effective and safe for PJI control following one-stage revision in a rat model, with less meropenem use. Cite this article: Bone Joint Res 2024;13(10):546–558


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 6 | Pages 736 - 741
1 Jun 2007
Daniel J Ziaee H Pynsent PB McMinn DJW

Metal ions generated from joint replacements are a cause for concern. There is no consensus on the best surrogate measure of metal ion exposure. This study investigates whether serum and whole blood concentrations can be used interchangeably to report results of cobalt and chromium ion concentrations. Concentrations of serum and whole blood were analysed in 262 concurrent specimens using high resolution inductively-coupled plasma mass-spectrometry. The agreement was assessed with normalised scatterplots, mean difference and the Bland and Altman limits of agreement. The wide variability seen in the normalised scatterplots, in the Bland and Altman plots and the statistically significant mean differences between serum and whole blood concentrations suggest that they cannot be used interchangeably. A bias was demonstrated for both ions in the Bland-Altman plots. Regression analysis provided a possible conversion factor of 0.71 for cobalt and 0.48 for chromium. However, even when the correction factors were applied, the limits of agreement were greater than ±67% for cobalt and greater than ±85% for chromium, suggesting that serum and whole blood cannot be used interconvertibly. This suggests that serum metal concentrations are not useful as a surrogate measure of systemic metal ion exposure


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1587 - 1593
1 Dec 2009
Oh JH Kim SH Kim JH Shin YH Yoon JP Oh CH

This study examined the role of vitamin D as a factor accounting for fatty degeneration and muscle function in the rotator cuff. There were 366 patients with disorders of the shoulder. A total of 228 patients had a full-thickness tear (group 1) and 138 patients had no tear (group 2). All underwent magnetic resonance arthrography and an isokinetic muscle performance test. The serum concentrations of vitamin D (25(OH)D. 3. ) were measured. In general, a lower serum level of vitamin D was related to higher fatty degeneration in the muscles of the cuff. Spearman’s correlation coefficients were 0.173 (p = 0.001), −0.181 (p = 0.001), and −0.117 (p = 0.026) for supraspinatus, infraspinatus and subscapularis, respectively. In group 1, multivariate linear regression analysis revealed that the serum level of vitamin D was an independent variable for fatty degeneration of the supraspinatus and infraspinatus. The serum vitamin D level has a significant negative correlation with the fatty degeneration of the cuff muscle and a positive correlation with isokinetic muscle torque


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 10 | Pages 1426 - 1433
1 Oct 2005
Kobayashi T Watanabe H Yanagawa T Tsutsumi S Kayakabe M Shinozaki T Higuchi H Takagishi K

Human bone-marrow mesenchymal stem cells have an important role in the repair of musculoskeletal tissues by migrating from the bone marrow into the injured site and undergoing differentiation. We investigated the use of autologous human serum as a substitute for fetal bovine serum in the ex vivo expansion medium to avoid the transmission of dangerous transfectants during clinical reconstruction procedures. Autologous human serum was as effective in stimulating growth of bone-marrow stem cells as fetal bovine serum. Furthermore, medium supplemented with autologous human serum was more effective in promoting motility than medium with fetal bovine serum in all cases. Addition of B-fibroblast growth factor to medium with human serum stimulated growth, but not motility. Our results suggest that autologous human serum may provide sufficient ex vivo expansion of human bone-marrow mesenchymal stem cells possessing multidifferentiation potential and may be better than fetal bovine serum in preserving high motility


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1003 - 1005
1 Aug 2006
Grübl A Weissinger M Brodner W Gleiss A Giurea A Gruber M Pöll G Meisinger V Gottsauner-Wolf F Kotz R

In a randomised study, 28 patients with a mean age of 62.2 years (32 to 81) with osteoarthritis or avascular necrosis of the hip received either a ceramic-on-ceramic or a metal-on-metal total hip replacement. Apart from the liners the acetabular and femoral components were made of Ti-Al-Nb alloy. The serum aluminium and cobalt levels were measured before, and at one year after surgery. The 15 patients in the ceramic-on-ceramic group had a median pre-operative aluminium level of 1.3 μg/l (0.25 to 8.4) and a cobalt level below the detection limit. At one year the aluminium level was 1.1 μg/l (0.25 to 2.3) and the cobalt level was 0.4 μg/l (0.15 to 0.7). The 13 patients in the metal-on-metal group had a median pre-operative aluminium level of 1.9 μg/l (0.25 to 4.4) and a cobalt level below the detection limit. At one year the median aluminium level was 0.9 μg/l (0.25 to 3.9) whereas the cobalt level was 1.4 μg/l (0.5 to 10.5). This increase in the cobalt level at one year was significant (p < 0.001). Our findings indicate that ceramic-on-ceramic bearings do not cause elevated levels of serum aluminium in the first post-operative year


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 4 | Pages 555 - 559
1 Apr 2010
Deguchi M Shinjo R Yoshioka Y Seki H

The post-operative changes in the serum levels of CRP and serum amyloid A (SAA) were investigated prospectively in 106 patients after posterior lumbar interbody fusion. In 96 patients who did not have complications related to infection within the first year after operation, the median levels of CRP before operation and on days 3, 7 and 13 after were 0.02 (0.01 to 0.03), 9.12 (2.36 to 19.82), 1.64 (0.19 to 6.10) and 0.53 (0.05 to 2.94) mg/dl, respectively and for SAA, 2.6 (2.0 to 3.8), 1312.1 (58.0 to 3579.8), 77.3 (1.8 to 478.4), 14.1 (0.5 to 71.9) μg/ml, respectively. The levels on day 3 were the highest for both CRP and SAA and significantly decreased (p < 0.01) by day 7 and day 13. In regard to CRP, no patient had less than the reference level (0.1 mg/dl) on day 7. In only three had the level decreased to the reference level, while in 93 it was above this on day 13. However, for SAA, the levels became normal on day 7 in 10 cases and on day 13 in 34 cases. The ratios relative to the levels on day 3 were significantly lower for SAA compared with CRP on day 7 and day 13. Of the ten patients with infection in the early stages, the level of CRP decreased slightly but an increase in SAA was observed in six. We concluded that SAA is better than CRP as a post-operative inflammatory marker


The Journal of Bone & Joint Surgery British Volume
Vol. 47-B, Issue 1 | Pages 137 - 139
1 Feb 1965
Parfitt AM

1. The changes in serum calcium and phosphorus which occurred in forty-one patients with post-menopausal osteoporosis during treatment with stilboestrol were examined. 2. There was a fall of approximately 15 per cent in mean serum phosphorus and of approximately 3 per cent in mean serum calcium. 3. The fall in serum calcium is considered to furnish some evidence against the theory that the primary action of stilboestrol is a reduction in calcium excretion


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 1 | Pages 85 - 87
1 Jan 1989
Alkalay D Shany S Dekel S

Vitamin D metabolite levels were measured in serum and bone samples obtained from 27 patients undergoing elective bony procedures and from 28 patients operated on after a fracture. Serum 25 hydroxyvitamin D3 (25-OH-D3) and 24,25-dihydroxyvitamin D3 (24,25(OH)2D3) did not differ significantly between the elective and fracture patients, but serum 1,25-dihydroxyvitamin D3 (1,25(OH)2D3) was significantly reduced in the fracture patients. Very little 25-OH-D3 was found in bone, although it was the major vitamin D metabolite in serum (90%). In elective patients bone levels of 24,25(OH)2D3 and 1,25(OH)2D3 were similar to those in serum; however, in bone from around pertrochanteric fractures, but not from subcapital or patellar fractures, the concentrations of these compounds were considerably increased. These findings may shed light on the mechanism of callus formation and on the role of vitamin D metabolites in bone healing


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 5 | Pages 912 - 917
1 Sep 1998
Granchi D Verri E Ciapetti G Stea S Savarino L Sudanese A Mieti M Rotini R Dallari D Zinghi G Montanaro L

Our aim was to determine if the serum levels of bone-resorbing cytokines (IL-1β, TNF-α, IL-6, GM-CSF) are altered in patients with aseptic loosening of a total hip prosthesis, and if such levels are influenced by the type of implant. We determined cytokine levels in sera from 35 patients before revision for failed total hip arthroplasty and compared them with those in 25 healthy donors. We also assessed the soluble receptor of interleukin-2 (sIL-2r) in serum as an indication of a specific immune reaction against the implant. Our findings showed that the sIL-2r and TNF-α serum level did not change. The IL-6 level was not significantly altered, but was higher in patients with TiAlV prostheses than in those with a CrCoMo implant and in patients with cemented prostheses. The IL-1β level was found to be higher in those with a TiAlV cemented prosthesis than in the control group (p = 0.0001) and other groups of patients (p = 0.003 v uncemented TiAlV, p = 0.01 v cemented CrCoMo, p = 0.001 v uncemented CrCoMo). The GM-CSF level significantly increased in patients compared with healthy subjects (p = 0.008), and it was higher in those with cemented than with uncemented implants (p = 0.01). Only patients with cementless CrCoMo prostheses had levels of GM-CSF similar to those of the control group. The highest GM-CSF concentrations were observed in patients treated with non-steroidal anti-inflammatory drugs (NSAIDs) in the last months before revision (p = 0.04). In addition, when massive osteolysis was observed, the level of GM-CSF tended to decrease to that of the control group


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 2 | Pages 316 - 321
1 Mar 1997
Brodner W Bitzan P Meisinger V Kaider A Gottsauner-Wolf F Kotz R

We determined serum cobalt levels in 55 patients by atomic absorption spectrophotometry before and after implantation of uncemented total hip arthroplasties. In a randomised, prospective trial 27 wrought Co-28Cr-6Mo-0.2C metal-on-metal articulations were compared with 28 ceramic-on-polyethylene hips which did not contain cobalt. Other sources of iatrogenic cobalt loading were excluded. The metal-on-metal group produced detectable serum cobalt levels (median 1.1 μg/l after one year) which were significantly different (p < 0.0001) from those of the ceramic-on-polyethylene control group (median below detection limit of 0.3 μg/l after one year). Our findings indicate that metal-on-metal bearings generate some systemic release of cobalt


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 1 | Pages 61 - 65
1 Feb 1978
Hosking D

Osteomalacia may be a contributory factor in some patients in the development of fractures of the femoral neck and complicate the subsequent management. The level of serum alkaline phosphatase is often valuable in the diagnosis of metabolic bone disease but rises after any uncomplicated fracture, and since such a rise may limit the diagnostic usefulness of this measurement in detecting osteomalacia its extent was assessed in 106 patients. In the majority serum levels were normal on admission, rising after seven to nine days to reach a maximum within a month after fracture. Elevated levels on admission were found in patients with osteomalacia, liver damage or where there had been a delay of several weeks between injury and admission. In a small number of patients normal levels on admission subsequently reached very high values, usually in association with comminution or instability of the fracture. Elevated levels persisted for six to twelve weeks after fracture, the major influence upon the level at this time being the maximum value achieved rather than the presence of osteomalacia. If patients are to be screened for osteomalacia, the alkaline phosphatase must be measured within the first week after a fracture to avoid the distorting influences of the fracture itself


The Journal of Bone & Joint Surgery British Volume
Vol. 61-B, Issue 4 | Pages 432 - 434
1 Nov 1979
Mollan R

Estimations of serum alkaline phosphatase were carried out prospectively on a series of patients having a total hip replacement. The levels of serum alkaline phosphatase before operation indicated a group of patients who subsequently developed heterotopic ossification. Levels of this enzyme after operation did not indicate those patients who were developing heterotopic ossification


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 4 | Pages 645 - 649
1 Jul 1993
Hardy Conlan D Hay S Gregg P

The changes in serum adjusted ionised calcium and parathyroid hormone (PTH) were prospectively studied in 32 patients with isolated tibial fractures, treated conservatively. We measured serum albumin, adjusted total calcium, phosphate, pH, adjusted ionised calcium and PTH at intervals until the fractures had healed. The mean ionised calcium adjusted for pH fell within 24 hours of injury, and then rose to a peak at between four and six weeks. These changes cannot be explained by changes in serum pH or PTH. The restoration of normal ionised calcium levels after fracture coincided with the period when the callus was being calcified. Analysis of the changes in ionised calcium, phosphate and PTH suggests that PTH levels alter in response to changes in ionised calcium levels. PTH is highest immediately after fracture and lowest, often not recordable, at six weeks. The cause of the changes in the ionised calcium level has yet to be elucidated


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 3 | Pages 509 - 510
1 May 1991
Joseph B

Serum immunoglobulin concentrations in 41 children with Perthes' disease and 82 age and sex matched controls were measured by radial immunodiffusion. Significant increases in IgG and IgM were seen in children with Perthes' disease


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 8 | Pages 1151 - 1154
1 Nov 2003
Sugimori K Kawaguchi Y Morita M Kitajima I Kimura T

We measured the serum concentration of C-reactive protein (CRP) by a high-sensitive method in patients with lumbar disc herniation. There were 48 patients in the study group and 53 normal controls. The level and type of herniation were evaluated. The clinical data including the neurological findings, the angle of straight leg raising and post-operative recovery as measured by the Japanese Orthopaedic Association (JOA) score, were recorded. The high-sensitive CRP (hs-CRP) was measured by an ultrasensitive latex-enhanced immunoassay. The mean hs-CRP concentration was 0.056 ± 0.076 mg/dl in the patient group and 0.017 ± 0.021 mg/dl in the control group. The difference was statistically significant (p = 0.006). There was no other correlation between the hs-CRP concentration and the level and type of herniation, or the pre-operative clinical data. A positive correlation was found between the concentration of hs-CRP before operation and the JOA score after. Those with a higher concentration of hs-CRP before operation showed a poorer recovery after. The significantly high concentration of serum hs-CRP might indicate a systemic inflammatory response to impingement of the nerve root caused by disc herniation and might be a predictor of recovery after operation


The Bone & Joint Journal
Vol. 105-B, Issue 4 | Pages 373 - 381
15 Mar 2023
Jandl NM Kleiss S Mussawy H Beil FT Hubert J Rolvien T

Aims

The aim of this study was to evaluate the diagnostic accuracy of the absolute synovial polymorphonuclear neutrophil cell (PMN) count for the diagnosis or exclusion of periprosthetic joint infection (PJI) after total hip (THA) or knee arthroplasty (TKA).

Methods

In this retrospective cohort study, 147 consecutive patients with acute or chronic complaints following THA and TKA were included. Diagnosis of PJI was established based on the 2018 International Consensus Meeting criteria. A total of 39 patients diagnosed with PJI (32 chronic and seven acute) and 108 patients with aseptic complications were surgically revised.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 3 | Pages 431 - 433
1 May 1996
Niskanen RO Korkala O Pammo H

Any operation induces an elevation in the level of serum C-reactive protein (CRP). After hip and knee arthroplasty the maximal values are seen on the second and third postoperative days, after which the CRP decreases rapidly. There is no difference between patients with cemented or uncemented prostheses. Major postoperative complications may cause a further increase in CRP levels at one and two weeks


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1345 - 1351
1 Oct 2018
Kuo F Lu Y Wu C You H Lee G Lee MS

Aims

The aim of this study was to compare the results of 16S/28S rRNA sequencing with the erythrocyte sedimentation rate (ESR), C-reactive protein (CRP) level, and synovial fluid analysis in the diagnosis of prosthetic joint infection (PJI).

Patients and Methods

Between September 2015 and August 2016, 214 consecutive patients were enrolled. In the study population, there were 25 patients with a PJI and 189 controls. Of the PJI patients, 14 (56%) were women, and the mean age at the time of diagnosis was 65 years (38 to 83). The ESR and CRP levels were measured, and synovial fluid specimens were collected prospectively. Synovial fluid was subjected to reverse transcription polymerase chain reaction (RT-PCR)/sequence analysis targeting the 16S/28S rRNA, and to conventional culture. Laboratory personnel who were blind to the clinical information performed all tests. The diagnosis of PJI was based on the criteria of the Musculoskeletal Infection Society.