Advertisement for orthosearch.org.uk
Results 21 - 40 of 333
Results per page:
The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 33 - 39
1 Jul 2019
Lachiewicz PF O’Dell JA

Aims

There is insufficient evidence to recommend the use of alternative polyethylene bearings in modular, fixed-bearing total knee arthroplasty (TKA). The purpose of this study was to compare standard polyethylene (SP) and highly crosslinked polyethylene (XLP) tibial liners in posterior-stabilized TKA, with osteolysis as the primary outcome and clinical results and the rate of re-operation as the secondary outcomes.

Patients and Methods

This is a single-surgeon, prospective randomized study involving one design of modular posterior-stabilized TKA. An analysis of 122 TKAs with an SP compression moulded liner and 123 with an XLP liner was performed, with a mean follow-up of six years (2 to 11). Patients were evaluated clinically using the Knee Society score, Lower Extremity Activity Score (LEAS), and the presence of an effusion, and standard radiographs were assessed for radiolucent lines and osteolytic lesions.


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 84 - 90
1 Jul 2019
Jennings JM Loyd BJ Miner TM Yang CC Stevens-Lapsley J Dennis DA

Aims

The aim of this study was to determine whether closed suction drain (CSD) use influences recovery of quadriceps strength and to examine the effects of drain use on secondary outcomes: quadriceps activation, intra-articular effusion, bioelectrical measure of swelling, range of movement (ROM), pain, and wound healing complications.

Patients and Methods

A total of 29 patients undergoing simultaneous bilateral total knee arthroplasty (TKA) were enrolled in a prospective, randomized blinded study. Patients were randomized to receive a CSD in one limb while the contralateral limb had the use of a subcutaneous drain (SCDRN) without the use of suction (‘sham drain’). Isometric quadriceps strength was collected as the primary outcome. Secondary outcomes consisted of quadriceps activation, intra-articular effusion measured via ultrasound, lower limb swelling measured with bioelectrical impendence and limb girth, knee ROM, and pain. Outcomes were assessed preoperatively and postoperatively at day two, two and six weeks, and three months. Differences between limbs were determined using paired Student’s t-tests or Wilcoxon’s signed-rank tests.


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 964 - 972
1 Jul 2017
Duckworth AD Clement ND McEachan JE White TO Court-Brown CM McQueen MM

Aims

The aim of this prospective randomised controlled trial was to compare non-operative and operative management for acute isolated displaced fractures of the olecranon in patients aged ≥ 75 years.

Patients and Methods

Patients were randomised to either non-operative management or operative management with either tension-band wiring or fixation with a plate. They were reviewed at six weeks, three and six months and one year after the injury. The primary outcome measure was the Disabilities of the Arm, Shoulder and Hand (DASH) score at one year.


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 5 | Pages 848 - 850
1 Nov 1989
Bannister G Wallace W Stableforth P Hutson M

In a prospective study, 60 patients with acute acromioclavicular dislocation were randomly allocated to treatment with a broad arm sling or to reduction and fixation with a coracoclavicular screw. Of these 54 were followed for four years. Conservatively-treated patients regained movement significantly more quickly and fully, returned to work and sport earlier and had fewer unsatisfactory results than those having early operation. For severe dislocations, with acromioclavicular displacement of 2 cm or more, early surgery produced better results. Conservative management is best for most acute dislocations, but younger patients with severe displacement may benefit from early reduction and stabilisation.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 4 | Pages 615 - 619
1 Aug 1987
Bostman O Vainionpaa S Hirvensalo E Makela A Vihtonen K Tormala P Rokkanen P

Fifty-six patients with displaced malleolar fractures had open reduction and fixation of the fracture fragments using, by random selection, either biodegradable implants or metal AO plates and screws. The cylindrical biodegradable implants were made of polylactide-glycolide copolymer (polyglactin 910). The complications, radiographic results and functional recovery were studied prospectively. After follow-up of at least one year, no significant differences emerged in the complication rate or in the results of treatment between the two methods of fixation. Because of the advantage of avoiding the need to remove metal fixation after union, we now use biodegradable internal fixation routinely to treat displaced malleolar fractures.


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 548 - 554
1 Apr 2014
Sun H Luo CF Zhong B Shi HP Zhang CQ Zeng BF

Our aim was to compare polylevolactic acid screws with titanium screws when used for fixation of the distal tibiofibular syndesmosis at mid-term follow-up. A total of 168 patients, with a mean age of 38.5 years (18 to 72) who were randomly allocated to receive either polylevolactic acid (n = 86) or metallic (n = 82) screws were included. The Baird scoring system was used to assess the overall satisfaction and functional recovery post-operatively. The demographic details and characteristics of the injury were similar in the two groups. The mean follow-up was 55.8 months (48 to 66). The Baird scores were similar in the two groups at the final follow-up. Patients in the polylevolactic acid group had a greater mean dorsiflexion (p = 0.011) and plantar-flexion of the injured ankles (p < 0.001). In the same group, 18 patients had a mild and eight patients had a moderate foreign body reaction. In the metallic groups eight had mild and none had a moderate foreign body reaction (p <  0.001). In total, three patients in the polylevolactic acid group and none in the metallic group had heterotopic ossification (p = 0.246).

We conclude that both screws provide adequate fixation and functional recovery, but polylevolactic acid screws are associated with a higher incidence of foreign body reactions.

Cite this article: Bone Joint J 2014;96-B:548–54.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 4 | Pages 654 - 659
1 Jul 1994
Beard D Dodd C Trundle H Simpson A

We performed a prospective, double-blind, randomised, clinical trial to investigate the efficacy of two regimes of rehabilitation for knees with anterior cruciate ligament deficiency (ACLD). Fifty ACLD patients were randomly allocated to one of two treatment groups: a programme of muscle strengthening (T) or a programme designed to enhance proprioception and improve hamstring contraction reflexes (P). An indirect measure of proprioception, the reflex hamstring contraction latency (RHCL), and a functional scoring system were used to record the status of the knee before and after the 12-week course of physiotherapy. Sagittal knee laxity was also measured. There was improvement in mean RHCL and in the mean functional score in both groups after treatment. The improvement in group P was significantly greater than that in group T. There was no significant change in joint laxity after treatment in either group. In both groups there was a positive correlation between improvement in RHCL and functional gain.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 3 | Pages 464 - 465
1 Apr 2003
DE ROECK N


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 2 | Pages 183 - 188
1 Mar 2002
Rogmark C Carlsson Å Johnell O Sernbo I

It remains a matter of debate whether displaced fractures of the neck of the femur should be treated by internal fixation or arthroplasty. We have compared the two methods with regard to complications, mortality and functional outcome.

We studied 409 patients, aged 70 years and over, with subcapital fractures graded as Garden 3 or 4, in a two-year prospective multicentre study from 12 Swedish hospitals. They were randomised to internal fixation or arthroplasty. Patients who were mentally confused, bedridden or in a nursing-home were excluded from the survey.

After two years the rate of failure was 43% in the internal fixation (IF) and 6% in the arthroplasty group (p < 0.001). In the IF group 36% had impaired walking and 6% had severe pain compared with 25% and 1.5%, respectively, in the arthroplasty group (both p < 0.05). There was no difference in mortality.

With a high rate of failure and poor functional outcome after IF, we recommend primary arthroplasty for displaced fractures of the neck of the femur in patients over 70 years of age.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 433 - 434
1 Mar 2005
VANDERESTRAETEN L BINNS MS


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 984 - 988
1 Jul 2010
Guo JJ Tang N Yang HL Tang TS

We compared the outcome of closed intramedullary nailing with minimally invasive plate osteosynthesis using a percutaneous locked compression plate in patients with a distal metaphyseal fracture in a prospective study.

A total of 85 patients were randomised to operative stabilisation either by a closed intramedullary nail (44) or by minimally invasive osteosynthesis with a compression plate (41). Pre-operative variables included the patients’ age and the side and pattern of the fracture. Peri-operative variables were the operating time and the radiation time. Postoperative variables were wound problems, the time to union of the fracture, the functional American Orthopaedic Foot and Ankle surgery score and removal of hardware.

We found no significant difference in the pre-operative variables or in the time to union in the two groups. However, the mean radiation time and operating time were significantly longer in the locked compression plate group (3.0 vs 2.12 minutes, p < 0.001, and 97.9 vs 81.2 minutes, p < 0.001, respectively). After one year, all the fractures had united. Patients who had intramedullary nailing had a higher mean pain score, but better function, alignment and total American Orthopaedic Foot and Ankle surgery scores, although the differences were not statistically significant (p = 0.234, p = 0.157, p = 0.897, p = 0.177 respectively). Three (6.8%) patients in the intramedullary nailing group and six (14.6%) in the locked compression plate group showed delayed wound healing, and 37 (84.1%) in the former group and 38 (92.7%) in the latter group expressed a wish to have the implant removed.

We conclude that both closed intramedullary nailing and a percutaneous locked compression plate can be used safely to treat Orthopaedic Trauma Association type-43A distal metaphyseal fractures of the tibia. However, closed intramedullary nailing has the advantage of a shorter operating and radiation time and easier removal of the implant. We therefore prefer closed intramedullary nailing for patients with these fractures.


Bone & Joint Open
Vol. 5, Issue 1 | Pages 69 - 77
25 Jan 2024
Achten J Appelbe D Spoors L Peckham N Kandiyali R Mason J Ferguson D Wright J Wilson N Preston J Moscrop A Costa M Perry DC

Aims. The management of fractures of the medial epicondyle is one of the greatest controversies in paediatric fracture care, with uncertainty concerning the need for surgery. The British Society of Children’s Orthopaedic Surgery prioritized this as their most important research question in paediatric trauma. This is the protocol for a randomized controlled, multicentre, prospective superiority trial of operative fixation versus nonoperative treatment for displaced medial epicondyle fractures: the Surgery or Cast of the EpicoNdyle in Children’s Elbows (SCIENCE) trial. Methods. Children aged seven to 15 years old inclusive, who have sustained a displaced fracture of the medial epicondyle, are eligible to take part. Baseline function using the Patient-Reported Outcomes Measurement Information System (PROMIS) upper limb score, pain measured using the Wong Baker FACES pain scale, and quality of life (QoL) assessed with the EuroQol five-dimension questionnaire for younger patients (EQ-5D-Y) will be collected. Each patient will be randomly allocated (1:1, stratified using a minimization algorithm by centre and initial elbow dislocation status (i.e. dislocated or not-dislocated at presentation to the emergency department)) to either a regimen of the operative fixation or non-surgical treatment. Outcomes. At six weeks, and three, six, and 12 months, data on function, pain, sports/music participation, QoL, immobilization, and analgesia will be collected. These will also be repeated annually until the child reaches the age of 16 years. Four weeks after injury, the main outcomes plus data on complications, resource use, and school absence will be collected. The primary outcome is the PROMIS upper limb score at 12 months post-randomization. All data will be obtained through electronic questionnaires completed by the participants and/or parents/guardians. The NHS number of participants will be stored to enable future data linkage to sources of routinely collected data (i.e. Hospital Episode Statistics). Cite this article: Bone Jt Open 2024;5(1):69–77


Bone & Joint Open
Vol. 3, Issue 8 | Pages 656 - 665
23 Aug 2022
Tran T McEwen P Peng Y Trivett A Steele R Donnelly W Clark G

Aims. The mid-term results of kinematic alignment (KA) for total knee arthroplasty (TKA) using image derived instrumentation (IDI) have not been reported in detail, and questions remain regarding ligamentous stability and revisions. This paper aims to address the following: 1) what is the distribution of alignment of KA TKAs using IDI; 2) is a TKA alignment category associated with increased risk of failure or poor patient outcomes; 3) does extending limb alignment lead to changes in soft-tissue laxity; and 4) what is the five-year survivorship and outcomes of KA TKA using IDI?. Methods. A prospective, multicentre, trial enrolled 100 patients undergoing KA TKA using IDI, with follow-up to five years. Alignment measures were conducted pre- and postoperatively to assess constitutional alignment and final implant position. Patient-reported outcome measures (PROMs) of pain and function were also included. The Australian Orthopaedic Association National Joint Arthroplasty Registry was used to assess survivorship. Results. The postoperative HKA distribution varied from 9° varus to 11° valgus. All PROMs showed statistical improvements at one year (p < 0.001), with further improvements at five years for Knee Osteoarthritis Outcome Score symptoms (p = 0.041) and Forgotten Joint Score (p = 0.011). Correlation analysis showed no difference (p = 0.610) between the hip-knee-ankle and joint line congruence angle at one and five years. Sub-group analysis showed no difference in PROMs for patients placed within 3° of neutral compared to those placed > 3°. There were no revisions for tibial loosening; however, there were reports of a higher incidence of poor patella tracking and patellofemoral stiffness. Conclusion. PROMs were not impacted by postoperative alignment category. Ligamentous stability was maintained at five years with joint line obliquity. There were no revisions for tibial loosening despite a significant portion of tibiae placed in varus; however, KA executed with IDI resulted in a higher than anticipated rate of patella complications. Cite this article: Bone Jt Open 2022;3(8):656–665


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1723 - 1734
1 Dec 2020
Fung B Hoit G Schemitsch E Godbout C Nauth A

Aims. The purpose of this study was to: review the efficacy of the induced membrane technique (IMT), also known as the Masquelet technique; and investigate the relationship between patient factors and technique variations on the outcomes of the IMT. Methods. A systematic search was performed in CINAHL, The Cochrane Library, Embase, Ovid MEDLINE, and PubMed. We included articles from 1 January 1980 to 30 September 2019. Studies with a minimum sample size of five cases, where the IMT was performed primarily in adult patients (≥ 18 years old), in a long bone were included. Multivariate regression models were performed on patient-level data to determine variables associated with nonunion, postoperative infection, and the need for additional procedures. Results. A total of 48 studies were included, with 1,386 cases treated with the IMT. Patients had a mean age of 40.7 years (4 to 88), and the mean defect size was 5.9 cm (0.5 to 26). In total, 82.3% of cases achieved union after the index second stage procedure. The mean time to union was 6.6 months (1.4 to 58.7) after the second stage. Our multivariate analysis of 450 individual patients showed that the odds of developing a nonunion were significantly increased in those with preoperative infection. Patients with tibial defects, and those with larger defects, were at significantly higher odds of developing a postoperative infection. Our analysis also demonstrated a trend towards the inclusion of antibiotics in the cement spacer having a protective effect against the need for additional procedures. Conclusion. The IMT is an effective management strategy for complex segmental bone defects. Standardized reporting of individual patient data or larger prospective trials is required to determine the optimal implementation of this technique. This is the most comprehensive review of the IMT, and the first to compile individual patient data and use regression models to determine predictors of outcomes. Cite this article: Bone Joint J 2020;102-B(12):1723–1734


Aims. The study was undertaken to compare the efficacy of Woodcast splints and plaster-of-Paris casts in maintaining correction following sequential manipulation of idiopathic clubfeet. Methods. In this randomized prospective trial, 23 idiopathic clubfeet were immobilized with plaster-of-Paris casts and 23 clubfeet were immobilized with a splint made of Woodcast that encircled only two-thirds the circumference of the limb. The number of casts or splints needed to obtain full correction, the frequency of cast or splint-related complications, and the time taken for application and removal of the casts and splints were compared. Results. The mean number of casts required to obtain full correction of the deformity (Pirani Score 0) was 4.35 (95% confidence interval (CI) 3.74 to 4.95) when plaster-of-Paris was used and 4.87 (95% CI 4.33 to 5.41) when the Woodcast splint was used (p = 0.190). The time required for application and removal of the Woodcast splint were significantly less than that required for application and removal of plaster-of-Paris casts (p < 0.001). Woodcast splint-related complications were not more frequent than plaster-of-Paris cast related complications. Conclusion. Though Woodcast splints covering two-thirds of the circumference of the lower limbs of infants were effective in maintaining the correction of clubfoot deformity during serial manipulation and casting treatment, the superiority of Woodcasts over plaster-of-Paris could not be established. Cite this article: Bone Joint J 2020;102-B(10):1399–1404


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 321 - 328
1 Feb 2021
Vandeputte F Vanbiervliet J Sarac C Driesen R Corten K

Aims. Optimal exposure through the direct anterior approach (DAA) for total hip arthroplasty (THA) conducted on a regular operating theatre table is achieved with a standardized capsular releasing sequence in which the anterior capsule can be preserved or resected. We hypothesized that clinical outcomes and implant positioning would not be different in case a capsular sparing (CS) technique would be compared to capsular resection (CR). Methods. In this prospective trial, 219 hips in 190 patients were randomized to either the CS (n = 104) or CR (n = 115) cohort. In the CS cohort, a medial based anterior flap was created and sutured back in place at the end of the procedure. The anterior capsule was resected in the CR cohort. Primary outcome was defined as the difference in patient-reported outcome measures (PROMs) after one year. PROMs (Harris Hip Score (HHS), Hip disability and Osteoarthritis Outcome Score (HOOS), and Short Form 36 Item Health Survey (SF-36)) were collected preoperatively and one year postoperatively. Radiological parameters were analyzed to assess implant positioning and implant ingrowth. Adverse events were monitored. Results. At one year, there was no difference in HSS (p = 0.728), HOOS (Activity Daily Life, p = 0.347; Pain, p = 0.982; Quality of Life, p = 0.653; Sport, p = 0.994; Symptom, p = 0.459), or SF-36 (p = 0.338). Acetabular component inclination (p = 0.276) and anteversion (p = 0.392) as well as femoral component alignment (p = 0.351) were similar in both groups. There were no dislocations, readmissions, or reoperations in either group. The incidence of psoas tendinitis was six cases in the CS cohort (6%) and six cases in the CR cohort (5%) (p = 0.631). Conclusion. No clinical differences were found between resection or preservation of the anterior capsule when performing a primary THA through the DAA on a regular theatre table. In case of limited visibility during the learning curve, it might be advisable to resect a part of the anterior capsule. Cite this article: Bone Joint J 2021;103-B(2):321–328


Bone & Joint Open
Vol. 3, Issue 2 | Pages 114 - 122
1 Feb 2022
Green GL Arnander M Pearse E Tennent D

Aims. Recurrent dislocation is both a cause and consequence of glenoid bone loss, and the extent of the bony defect is an indicator guiding operative intervention. Literature suggests that loss greater than 25% requires glenoid reconstruction. Measuring bone loss is controversial; studies use different methods to determine this, with no clear evidence of reproducibility. A systematic review was performed to identify existing CT-based methods of quantifying glenoid bone loss and establish their reliability and reproducibility. Methods. A Preferred Reporting Items for Systematic reviews and Meta-Analyses-compliant systematic review of conventional and grey literature was performed. Results. A total of 25 studies were initially eligible. Following screening, nine papers were included for review. Main themes identified compared 2D and 3D imaging, as well as linear- compared with area-based techniques. Heterogenous data were acquired, and therefore no meta-analysis was performed. Conclusion. No ideal CT-based method is demonstrated in the current literature, however evidence suggests that surface area methods are more reproducible and lead to fewer over-estimations of bone loss, provided the views used are standardized. A prospective imaging trial is required to provide a more definitive answer to this research question. Cite this article: Bone Jt Open 2022;3(2):114–122


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 603 - 609
1 May 2019
Aagaard KE Lunsjö K Frobell R

Aims. Failure of healing is a well-known problem after repair of the rotator cuff. This study aimed to investigate if early repair of trauma-related full-thickness rotator cuff tears (FTRCTs) could prevent this failure. Patients and Methods. In this prospective trial, 62 consecutive patients (14 women (23%), 48 men (77%); median age 61 years (interquartile range (IQR) 54 to 65)) with trauma-related FTRCT underwent arthroscopic single-row repair within six weeks of trauma. Tendon integrity was assessed one year after surgery using the Sugaya score on MR images. Patients were followed up with Western Ontario Rotator Cuff (WORC) index, EuroQol visual analogue scale (EQ VAS), and the Constant–Murley score (CS) two years after repair. Results. A total of 57 patients (92%) had MR images available at one year; 59 patients (95%) had CS (one year), WORC (two years), and EQ VAS scores (two years). Intact repair was found on MRI in 36 patients (63%); 13 patients (23%) displayed healing failure of at least one repaired tendon and eight patients (14%) displayed total healing failure. Median WORC index and relative CS improved from 30.8 points (IQR 20.1 to 38.6) at baseline to 85.0 points (IQR 60.6 to 95.7) at two years and 26.5 points (IQR 21.2 to 37.4) to 83.2 points (IQR 71.9 to 97.5) at one year, respectively. The relative CS at one year was significantly better among those with intact repairs compared with those with healing failure (91.6 vs 78.1 points; p = 0.031). Conclusion. Although early repair of trauma-related FTRCT improved patient relevant outcomes over two years for the entire cohort, only two out of three repaired rotator cuffs displayed intact structural integrity on MRI after one year. Consequently, early repair did not seem to prevent healing failure after trauma-related FTRCT. Cite this article: Bone Joint J 2019;101-B:603–609


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 833 - 836
1 Aug 2023
Mancino F Gant V Meek DRM Haddad FS


Bone & Joint Research
Vol. 9, Issue 8 | Pages 477 - 483
1 Aug 2020
Holweg P Herber V Ornig M Hohenberger G Donohue N Puchwein P Leithner A Seibert F

Aims. This study is a prospective, non-randomized trial for the treatment of fractures of the medial malleolus using lean, bioabsorbable, rare-earth element (REE)-free, magnesium (Mg)-based biodegradable screws in the adult skeleton. Methods. A total of 20 patients with isolated, bimalleolar, or trimalleolar ankle fractures were recruited between July 2018 and October 2019. Fracture reduction was achieved through bioabsorbable Mg-based screws composed of pure Mg alloyed with zinc (Zn) and calcium (Ca) ( Mg-Zn0.45-Ca0.45, in wt.%; ZX00). Visual analogue scale (VAS) and the presence of complications (adverse events) during follow-up (12 weeks) were used to evaluate the clinical outcomes. The functional outcomes were analyzed through the range of motion (ROM) of the ankle joint and the American Orthopaedic Foot and Ankle Society (AOFAS) score. Fracture reduction and gas formation were assessed using several plane radiographs. Results. The follow-up was performed after at least 12 weeks. The mean difference in ROM of the talocrural joint between the treated and the non-treated sites decreased from 39° (SD 12°) after two weeks to 8° (SD 11°) after 12 weeks (p ≤ 0.05). After 12 weeks, the mean AOFAS score was 92.5 points (SD 4.1). Blood analysis revealed that Mg and Ca were within a physiologically normal range. All ankle fractures were reduced and stabilized sufficiently by two Mg screws. A complete consolidation of all fractures was achieved. No loosening or breakage of screws was observed. Conclusion. This first prospective clinical investigation of fracture reduction and fixation using lean, bioabsorbable, REE-free ZX00 screws showed excellent clinical and functional outcomes. Cite this article: Bone Joint Res 2020;9(8):477–483