Advertisement for orthosearch.org.uk
Results 21 - 40 of 87
Results per page:
The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 635 - 638
1 Jun 2019
Marson BA Hunter JB Price KR

Aims. The aim of this study was to review the value of accepting referrals for children with ‘clicky hips’ in a selective screening programme for hip dysplasia. Patients and Methods. A single-centre prospective database of all referrals to the hip clinic was examined to identify indication for referrals, diagnosis, and treatment. All patients referred received a standardized ultrasound scan and clinical examination by an orthopaedic consultant. Results. There were 5716 children referred to the orthopaedic hip clinic between 1 June 2014 and 26 September 2018. In all, 1754 children (30.1%) were referred due to ‘clicky hip’ with no additional risk factors or indications for ultrasound scan. A total of 123 children (7.1%) referred with ‘clicky hip’ and no additional risk factors or examination findings had an abnormal initial hip ultrasound, including 16 children (0.9%) with dysplastic hips. Of the 141 children who required treatment in a Pavlik harness during the study period, 23 (16%) had been referred with a ‘clicky hip’ and no additional risk factors or examination findings, including six children with Graf 3 or 4 hips. Conclusion. There is significant value in reviewing children with an isolated ‘clicky hip’. Many children who require treatment are referred to the orthopaedic service as ‘clicky hip’ with no additional risk factors. In a pragmatic pathway with a diverse population of clinicians performing baby checks, ‘clicky hip’ is an important indication for referral and should not be discarded. Cite this article: Bone Joint J 2019;101-B:635–638


The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1249 - 1252
1 Sep 2018
Humphry S Thompson D Price N Williams PR

Aims. The significance of the ‘clicky hip’ in neonatal and infant examination remains controversial with recent conflicting papers reigniting the debate. We aimed to quantify rates of developmental dysplasia of the hip (DDH) in babies referred with ‘clicky hips’ to our dedicated DDH clinic. Patients and Methods. A three-year prospective cohort study was undertaken between 2014 and 2016 assessing the diagnosis and treatment outcomes of all children referred specifically with ‘clicky hips’ as the primary reason for referral to our dedicated DDH clinic. Depending on their age, they were all imaged with either ultrasound scan or radiographs. Results. There were 69 ‘clicky hip’ referrals over the three-year period. This represented 26.9% of the total 257 referrals received in that time. The mean age at presentation was 13.6 weeks (1 to 84). A total of 19 children (28%) referred as ‘clicky hips’ were noted to have hip abnormalities on ultrasound scan, including 15 with Graf Type II hips (7 bilateral), one Graf Type III hip, and three Graf Type IV hips. Of these, ten children were treated with a Pavlik harness, with two requiring subsequent closed reduction in theatre; one child was treated primarily with a closed reduction and adductor tenotomy. In total, 11 (15.9%) of the 69 ‘clicky hip’ referrals required intervention with either harness or surgery. Conclusion. Our study provides further evidence that the ‘clicky hip’ referral can represent an underlying diagnosis of DDH and should, in our opinion, always lead to further clinical and radiological assessment. In the absence of universal ultrasound screening, we would encourage individual units to carefully assess their own outcomes and protocols for ‘clicky hip’ referrals and tailor ongoing service provision to local populations and local referral practices. Cite this article: Bone Joint J 2018;100-B:1249–52


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 265 - 269
1 Feb 2015
Mace J Paton RW

Over a 15-year prospective period, 201 infants with a clinically unstable hip at neonatal screening were subsequently reviewed in a ‘one stop’ clinic where they were assessed clinically and sonographically. Their mean age was 1.62 weeks (95% confidence interval (CI) 1.35 to 1.89). Clinical neonatal hip screening revealed a sensitivity of 62% (mean, 62.6 95%CI 50.9 to 74.3), specificity of 99.8% (mean, 99.8, 95% CI 99.7 to 99.8) and positive predictive value (PPV) of 24% (mean, 26.2, 95% CI 19.3 to 33.0). Static and dynamic sonography for Graf type IV dysplastic hips had a 15-year sensitivity of 77% (mean, 75.8 95% CI 66.9 to 84.6), specificity of 99.8% (mean, 99.8, 95% CI 99.8 to 99.8) and a PPV of 49% (mean, 55.1, 95% CI 41.6 to 68.5). There were 36 infants with an irreducible dislocation of the hip (0.57 per 1000 live births), including six that failed to resolve with neonatal splintage. Most clinically unstable hips referred to a specialist clinic are female and stabilise spontaneously. Most irreducible dislocations are not identified from this neonatal instability group. There may be a small subgroup of females with instability of the hip which may be at risk of progression to irreducibility despite early treatment in a Pavlik harness. A controlled study is required to assess the value of neonatal clinical screening programmes. Cite this article: Bone Joint J 2015;97-B:265-9


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 132 - 134
1 Jan 2013
Barr LV Rehm A

Twins are often considered to be at an increased risk of developmental dysplasia of the hip (DDH); we therefore investigated whether multiple births have a higher incidence of DDH, and if selective ultrasound scanning should be considered for these infants. We reviewed our records of all live births between 1 January 2004 and 31 December 2008 and included 25 246 single and 990 multiple births. Multiple births did not have a significantly higher incidence of DDH compared with single births (0.0030 vs 0.0023, p = 0.8939). Of the 990 multiple births, 267 had neonatal ultrasound scans and one case of DDH was diagnosed and treated successfully with a Pavlik harness. There were two late-presenting cases at eight and 14 months of age, neither of whom had risk factors for DDH and consequently had not had a neonatal scan. Whereas selective ultrasound scanning of multiple births would have led to earlier detection and treatment of the late-presenting cases, they did not have a significantly higher incidence of DDH compared with single births. We conclude that being a twin or triplet in itself is not a risk factor for DDH and that selective ultrasound scanning is not indicated for this population. Cite this article: Bone Joint J 2013;95-B:132–4


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 458 - 459
1 May 1994
Fiddian N Gardiner J

We report a prospective study of the feasibility of employing specially trained physiotherapists to screen neonates for congenital dislocation of the hip. During ten years 42,241 babies were screened, using clinical tests; 255 were diagnosed and treated by a Pavlik harness. In the same period 13 children presented late with congenital dislocation of the hip which had not been detected by the screening programme


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 2 | Pages 257 - 263
1 Mar 1987
Bradley J Wetherill M Benson M

Two-hundred and fifteen children with 288 unstable hips have been treated by splintage during the first nine months of life. A simple treatment protocol was followed and the aim was to test the safety and reliability of this protocol as well as of the Von Rosen splint and the Pavlik harness. A vascular necrosis occurred in 3.8% of the splinted hips. Despite splintage, a proportion of children needed operation at a later date


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 5 | Pages 695 - 700
1 Sep 1992
Poul J Bajerova J Sommernitz M Straka M Pokorny M Wong F

In this prospective study, 35,550 neonates were examined shortly after birth by a team of orthopaedic surgeons. They diagnosed 775 unstable or dislocated hips in 656 babies; there were two teratological dislocations. Treatment was first with a Frejka pillow and, if this failed to give a normal hip, a Pavlik harness at three months. Early clinical examination did not identify 21 infants who were found to have subluxation or dislocation of the hip at the three-month review. The number of missed cases declined during the study, however, reflecting the increasing experience of the examiners. One case of avascular necrosis occurred in the group treated from birth and one in the late-diagnosed group. Open reduction was necessary only in the two teratological dislocations. Experienced examiners are needed for accurate clinical diagnosis; and treatment should be started before the baby is discharged from the maternity ward


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 3 | Pages 406 - 412
1 May 1985
Clarke N Harcke H McHugh P Lee M Borns P MacEwen G

A technique of examining the infant hip joint with real-time ultrasound is described. Since the cartilaginous femoral head is clearly imaged by ultrasound, anatomical structures and their relationships can be accurately determined. Dislocated hips are easily detected and subluxations also can be visualized. We report our experience with 131 examinations in 104 patients, comprising 259 single hip studies. Of 83 patients who were previously untreated, there were 178 hip studies with three false-negative and four false-positive ultrasound results. No dislocations were missed. Twenty-seven patients who were already being treated were examined to assess hip location, comprising a total of 81 hip studies. In some cases the patients were examined while in an abduction device, cast, or Pavlik harness. In one case a dislocation was not detected. The method of examination using real-time ultrasound is considered to be reliable, accurate, and a useful adjunct to radiography. The advantages are that it is non-invasive, portable, and involves no exposure to radiation


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 5 | Pages 852 - 857
1 Sep 1999
Clegg J Bache CE Raut VV

We have analysed the patterns of management of developmental dysplasia of the hip (DDH) in Coventry over a period of 20 years during which three different screening policies were used. From 1976 to the end of 1985 we relied on clinical examination alone. The mean surgical cost for the treatment of DDH during this period was £5110 per 1000 live births. This was reduced to £3811 after the introduction of ultrasound for infants with known risk factors. Since June 1989 we have routinely scanned all infants at birth with a mean surgical cost of £468 per 1000 live births. This reduction in cost is a result of the earlier detection of DDH with fewer children requiring surgery. In those who do, fewer and less invasive procedures are needed. The overall rate of treatment has not increased and regular review of patients managed in a Pavlik harness has allowed us to avoid the complication of avascular necrosis. When we add the cost of running the screening programme to the expense of treating the condition, the overall cost for the management of DDH is comparable for the different screening policies


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 2 | Pages 176 - 179
1 Apr 1982
Bertol P Macnicol M Mitchell G

Over the 10-year period 1969 to 1978, 271 consecutive cases of congenital dislocation of the hip were diagnosed at birth. Standard anteroposterior radiographs of the pelvis were obtained routinely and were analysed retrospectively. The medial gap, a measure of the separation between the proximal femur and the pelvic wall, was found to be significantly increased in cases with unilateral or bilateral dislocation when compared to normal. A medial greater than five millimetres is indicative of femoral head displacement and is of value where the clinical diagnosis is uncertain. The rate of missed dislocation at birth was 0.6 cases per thousand. Treatment with the Malmo splint was the normal routine. The Pavlik harness was applied if splintage was poorly tolerated by the infant, or in the rare instance of limited hip abduction. Failure to maintain reduction by splintage occurred in 3.3 per cent. The incidence of pressure deformities of the femoral head was 2.95 per cent and there was a residual deformity in later childhood of 1.1 per cent. It is presumed that this lesion can be attributed to the effect of splintage and it was notably avoided in the later period of the review when greater mobility of the abducted hips was encouraged


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 4 | Pages 525 - 533
1 Jul 1994
Boeree N Clarke N

We report the preliminary results of a continuing prospective evaluation of a screening programme for congenital dislocation of the hip (CDH) which uses ultrasound imaging to provide delayed selective screening to complement neonatal clinical screening. Of 26,952 births in the Southampton district, 1894 infants were referred for secondary screening because of a clinical abnormality or the presence of a predetermined risk category for CDH. Pavlik harness treatment was required for only 118 infants, giving a treatment rate of 4.4 per 1000 births. Of those referred with clinical instability, 35% did not require treatment. Dislocation or subluxation was detected in 17 of 643 infants referred only because they fell within one of three risk categories: breech presentation, foot deformity and family history. All 17 had normal clinical examinations and cases were discovered in each category. Six children presented with CDH after 12 weeks of age, giving a late presentation rate of 0.22 per 1000 births. All had normal clinical examinations within 24 hours of birth and none was in a risk category. Surgery has been required in ten children, giving a surgical treatment rate of 0.37 per 1000 births. We conclude that, in Southampton, delayed selective secondary screening with ultrasound is more effective than clinical screening alone. It targets treatment to those infants who need it, and reveals a number of dislocated and subluxed hips that would otherwise be missed


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 198 - 208
1 Feb 2023
Cheok T Smith T Wills K Jennings MP Rawat J Foster B

Aims

We investigated the prevalence of late developmental dysplasia of the hip (DDH), abduction bracing treatment, and surgical procedures performed following the implementation of universal ultrasound screening versus selective ultrasound screening programmes.

Methods

A systematic search of PubMed, Embase, The Cochrane Library, OrthoSearch, and Web of Science from the date of inception of each database until 27 March 2022 was performed. The primary outcome of interest was the prevalence of late detection of DDH, diagnosed after three months. Secondary outcomes of interest were the prevalence of abduction bracing treatment and surgical procedures performed in childhood for dysplasia. Only studies describing the primary outcome of interest were included.


Bone & Joint 360
Vol. 11, Issue 5 | Pages 39 - 42
1 Oct 2022


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1327 - 1332
1 Dec 2023
Morris WZ Kak A Mayfield LM Kang MS Jo C Kim HKW

Aims

Abduction bracing is commonly used to treat developmental dysplasia of the hip (DDH) following closed reduction and spica casting, with little evidence to support or refute this practice. The purpose of this study was to determine the efficacy of abduction bracing after closed reduction in improving acetabular index (AI) and reducing secondary surgery for residual hip dysplasia.

Methods

We performed a retrospective review of patients treated with closed reduction for DDH at a single tertiary referral centre. Demographic data were obtained including severity of dislocation based on the International Hip Dysplasia Institute (IHDI) classification, age at reduction, and casting duration. Patients were prescribed no abduction bracing, part-time, or full-time wear post-reduction and casting. AI measurements were obtained immediately upon cast removal and from two- and four-year follow-up radiographs.


Bone & Joint 360
Vol. 13, Issue 5 | Pages 44 - 47
1 Oct 2024

The October 2024 Children’s orthopaedics Roundup360 looks at: Cost-effectiveness analysis of soft bandage and immediate discharge versus rigid immobilization in children with distal radius torus fractures: the FORCE trial; Percutaneous Achilles tendon tenotomy in clubfoot with a blade or a needle: a single-centre randomized controlled noninferiority trial; Treatment of hip displacement in children with cerebral palsy: a five-year comparison of proximal femoral osteotomy and combined femoral-pelvic osteotomy in 163 children; The Core outcome Clubfoot (CoCo) study: relapse, with poorer clinical and quality of life outcomes, affects 37% of idiopathic clubfoot patients; Retention versus removal of epiphyseal screws in paediatric distal tibial fractures: no significant impact on outcomes; Predicting the resolution of residual acetabular dysplasia after brace treatment in infant DDH; Low prevalence of acetabular dysplasia following treatment for neonatal hip instability: a long-term study; How best to distract the patient?.


Bone & Joint 360
Vol. 12, Issue 3 | Pages 37 - 40
1 Jun 2023

The April 2023 Children’s orthopaedics Roundup360 looks at: CT scan of the ipsilateral femoral neck in paediatric shaft fractures; Meniscal injuries in skeletally immature children with tibial eminence fractures: a systematic literature review; Post-maturity progression in adolescent idiopathic scoliosis curves of 40° to 50°; Prospective, randomized Ponseti treatment for clubfoot: orthopaedic surgeons versus physical therapists; FIFA 11+ Kids: challenges in implementing a prevention programme; The management of developmental dysplasia of the hip in children aged under three months: a consensus study from the British Society for Children's Orthopaedic Surgery; Early investigation and bracing in developmental dysplasia of the hip impacts maternal wellbeing and breastfeeding; Hip arthrodesis in children: a review of 26 cases with a mean of 20 years’ follow-up


The Bone & Joint Journal
Vol. 104-B, Issue 9 | Pages 1009 - 1010
1 Sep 2022
Haddad FS


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 247 - 253
1 Mar 2023
Pakarinen O Ponkilainen V Uimonen M Haapanen M Helenius I Kuitunen I

Aims

To analyze whether the addition of risk-based criteria to clinical examination-based selective ultrasound screening would increase the rates of early detected cases of developmental dysplasia of the hip (DDH) and decrease the rate of late detected cases.

Methods

A systematic review with meta-analysis was performed. The initial search was performed in the PubMed, Scopus, and Web of Science databases in November 2021. The following search terms were used: (hip) AND (ultrasound) AND (luxation or dysplasia) AND (newborn or neonate or congenital).


Bone & Joint 360
Vol. 12, Issue 1 | Pages 42 - 45
1 Feb 2023

The February 2023 Children’s orthopaedics Roundup360 looks at: Trends in management of paediatric distal radius buckle fractures; Pelvic osteotomy in patients with previous sacral-alar-iliac fixation; Sacral-alar-iliac fixation in patients with previous pelvic osteotomy; Idiopathic toe walking: an update on natural history, diagnosis, and treatment; A prediction model for treatment decisions in distal radial physeal injuries: a multicentre retrospective study; Angular deformities after percutaneous epiphysiodesis for leg length discrepancy; MRI assessment of anterior coverage is predictive of future radiological coverage; Predictive scoring for recurrent patellar instability after a first-time patellar dislocation.


Bone & Joint 360
Vol. 12, Issue 6 | Pages 42 - 45
1 Dec 2023

The December 2023 Children’s orthopaedics Roundup360 looks at: A comprehensive nonoperative treatment protocol for developmental dysplasia of the hip in infants; How common are refractures in childhood?; Femoral nailing for paediatric femoral shaft fracture in children aged eight to ten years; Who benefits from allowing the physis to grow in slipped capital femoral epiphysis?; Paediatric patients with an extremity bone tumour: a secondary analysis of the PARITY trial data; Split tibial tendon transfers in cerebral palsy equinovarus foot deformities; Liposomal bupivacaine nerve block: an answer to opioid use?; Correction with distal femoral transphyseal screws in hemiepiphysiodesis for coronal-plane knee deformity.