The aim of this study was to analyse the functional outcome after a displaced intracapsular fracture of the femoral neck in active patients aged over 70 years without osteoarthritis or rheumatoid arthritis of the hip, randomised to receive either a hemiarthroplasty or a total hip replacement (THR). We studied 252 patients of whom 47 (19%) were men, with a mean age of 81.1 years (70.2 to 95.6). They were randomly allocated to be treated with either a cemented hemiarthroplasty (137 patients) or cemented THR (115 patients). At one- and five-year follow-up no differences were observed in the modified Harris hip score, revision rate of the prosthesis, local and general complications, or mortality. The intra-operative blood loss was lower in the hemiarthroplasty group (7% >
500 ml) than in the THR group (26% >
500 ml) and the duration of surgery was longer in the THR group (28% >
1.5 hours Because of a higher intra-operative blood loss (p <
0.001), an increased duration of the operation (p <
0.001) and a higher number of early and late dislocations (p = 0.002), we do not recommend THR as the treatment of choice in patients aged ≥ 70 years with a fracture of the femoral neck in the absence of advanced radiological osteoarthritis or rheumatoid arthritis of the hip.
The Oxford Unicompartmental Knee replacement (UKR) was introduced as a design to reduce polyethylene wear. There has been one previous retrieval study involving this implant, which reported very low rates of wear in some specimens but abnormal patterns of wear in others. There has been no further investigation of these abnormal patterns. The bearings were retrieved from 47 patients who had received a medial Oxford UKR for anteromedial osteoarthritis of the knee. None had been studied previously. The mean time to revision was 8.4 years ( These results show that very low rates of polyethylene wear are possible if the device functions normally. However, if the bearing displays suboptimal function (extra-articular, intra-articular impingement or incongruous articulation) the rates of wear increase significantly.
Metal-on-metal bearings for total hip replacement (THR) are becoming increasingly popular. Improved wear characteristics mean that these articulations are being inserted into younger patients in the form of THR and resurfacing procedures. This has led to concerns regarding potential carcinogenicity because of the increased exposure to metal ions that the procedure brings. We have studied the serum cobalt and chromium concentrations in patients who had primary, well-fixed Ring metal-on-metal THRs for more than 30 years. The levels of cobalt and chromium were elevated by five and three times, respectively compared with those in our reference groups. Metal-on-metal articulations appear to be the source of metal ions throughout the life of the prosthesis. In three patients who had undergone revision of a previous metal-on-metal THR to a metal-on-polyethylene replacement the levels of metal ions were within the normal range. The elevations of cobalt and chromium ions seen in our study were comparable with those in patients with modern metal-on-metal THRs.
Polyethylene particulate wear debris continues to be implicated in the aetiology of aseptic loosening following knee arthroplasty. The Oxford unicompartmental knee arthroplasty employs a spherical femoral component and a fully congruous meniscal bearing to increase contact area and theoretically reduce the potential for polyethylene wear. This study measures the In this The results from this