Advertisement for orthosearch.org.uk
Results 21 - 40 of 749
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 3 | Pages 445 - 448
1 May 1992
Graham G Dent C

We reviewed the long-term results of the Dillwyn Evans procedure for club foot in 60 feet of 45 patients with an average age of 29 years, using four different scoring systems. The results at 12 to 38 years were compared with those of an earlier study of the same group of patients. Function was satisfactory in 68% of feet; 90% of the patients were able to perform all desired activities. Mild residual deformity was compatible with satisfactory function, and poor function was related to ankle and subtalar stiffness. Our results suggest that this procedure has a low rate of deterioration and degenerative change with time


The Bone & Joint Journal
Vol. 96-B, Issue 8 | Pages 1047 - 1051
1 Aug 2014
Lee PTH Lakstein DL Lozano B Safir O Backstein J Gross AE

Revision total hip replacement (THR) for young patients is challenging because of technical complexity and the potential need for subsequent further revisions. We have assessed the survivorship, functional outcome and complications of this procedure in patients aged <  50 years through a large longitudinal series with consistent treatment algorithms. Of 132 consecutive patients (181 hips) who underwent revision THR, 102 patients (151 hips) with a mean age of 43 years (22 to 50) were reviewed at a mean follow-up of 11 years (2 to 26) post-operatively. We attempted to restore bone stock with allograft where indicated. Using further revision for any reason as an end point, the survival of the acetabular component was 71% (. sd. 4) and 54% (. sd. 7) at ten- and 20 years. The survival of the femoral component was 80% (. sd. 4) and 62% (. sd. 6) at ten- and 20 years. Complications included 11 dislocations (6.1%), ten periprosthetic fractures (5.5%), two deep infections (1.1%), four sciatic nerve palsies (2.2%; three resolved without intervention, one improved after exploration and freeing from adhesions) and one vascular injury (0.6%). The mean modified Harris Hip Score was 41 (10 to 82) pre-operatively, 77 (39 to 93) one year post-operatively and 77 (38 to 93) at the latest review. This overall perspective on the mid- to long-term results is valuable when advising young patients on the prospects of revision surgery at the time of primary replacement. Cite this article: Bone Joint J 2014;96-B:1047–51


The Bone & Joint Journal
Vol. 97-B, Issue 10_Supple_A | Pages 9 - 15
1 Oct 2015
Parratte S Ollivier M Lunebourg A Abdel MP Argenson J

Partial knee arthroplasty (PKA), either medial or lateral unicompartmental knee artroplasty (UKA) or patellofemoral arthroplasty (PFA) are a good option in suitable patients and have the advantages of reduced operative trauma, preservation of both cruciate ligaments and bone stock, and restoration of normal kinematics within the knee joint. However, questions remain concerning long-term survival. The goal of this review article was to present the long-term results of medial and lateral UKA, PFA and combined compartmental arthroplasty for multicompartmental disease. Medium- and long-term studies suggest reasonable outcomes at ten years with survival greater than 95% in UKA performed for medial osteoarthritis or osteonecrosis, and similarly for lateral UKA, particularly when fixed-bearing implants are used. Disappointing long-term outcomes have been observed with the first generation of patellofemoral implants, as well as early Bi-Uni (ie, combined medial and lateral UKA) or Bicompartmental (combined UKA and PFA) implants due to design and fixation issues. Promising short- and med-term results with the newer generations of PFAs and bicompartmental arthroplasties will require long-term confirmation.

Cite this article: Bone Joint J 2015;97-B(10 Suppl A):9–15.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 937 - 940
1 Jul 2012
Manopoulos P Havet E Pearce O Lardanchet JF Mertl P

This was a retrospective analysis of the medium- to long-term results of 46 TC3 Sigma revision total knee replacements using long uncemented stems in press-fit mode. Clinical and radiological analysis took place pre-operatively, at two years post-operatively, and at a mean follow-up of 8.5 years (4 to 12). The mean pre-operative International Knee Society (IKS) clinical score was 42 points (0 to 74), improving to 83.7 (52 to 100) by the final follow-up. The mean IKS score for function improved from 34.3 points (0 to 80) to 64.2 (15 to 100) at the final follow-up. At the final follow-up 30 knees (65.2%) had an excellent result, seven (15.2%) a good result, one (2.2%) a medium and eight (17.4%) a poor result. There were two failures, one with anteroposterior instability and one with aseptic loosening. The TC3 revision knee system, when used with press-fit for long intramedullary stems and cemented femoral and tibial components, in both septic and aseptic revisions, results in a satisfactory clinical and radiological outcome, and has a good medium- to long-term survival rate


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 1 | Pages 41 - 45
1 Jan 1990
Engelbrecht D Weber F Sweet M Jakim I

A total of 138 revision hip arthroplasties in 134 patients, all operated upon by one surgeon, were followed for an average of 7.4 years. The overall results were reasonable, with good to excellent Mayo hip scores in 62% and little or no pain in 86%. These results were independent of body weight, age, primary diagnosis and type of arthroplasty used. The incidence of radiological loosening was alarming, though comparable to that found in other series. Our findings indicate that it may be wise to replace both components even when, after careful assessment before and during operation, one of them seems to be securely fixed.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 1 | Pages 113 - 116
1 Jan 1988
Lynch A Bourne R Rorabeck C

The results of 62 ankle arthrodeses, mostly performed for osteoarthritis, have been reviewed; of these, 39 were examined clinically and radiographically after an average follow-up period of seven years. Compression arthrodesis was associated with the highest incidence of complications, and an anterior sliding graft gave the most satisfactory results. Very few patients required modification of their footwear; most could walk independently with a slight limp and were able to return to their pre-operative work. However, after operation, the ability to run and to participate in vigorous sporting activities was limited. Complications included wound infection, non-union, and some change in midtarsal mobility, but excellent pain relief was reported by all patients.


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1222 - 1226
1 Sep 2013
Faber FWM van Kampen PM Bloembergen MW

As it remains unproven that hypermobility of the first tarsometatarsal joint (TMTJ-1) is a significant factor in hallux valgus deformity, the necessity for including arthrodesis of TMTJ-1 as part of a surgical correction of a hallux valgus is questionable. In order to evaluate the role of this arthrodesis on the long-term outcome of hallux valgus surgery, a prospective, blinded, randomised study with long-term follow-up was performed, comparing the Lapidus procedure (which includes such an arthrodesis) with a simple Hohmann distal closing wedge metatarsal osteotomy. The study cohort comprised 101 feet in 87 patients: 50 feet were treated with a Hohmann procedure and 51 with a Lapidus procedure. Hypermobility of TMTJ-1 was assessed pre-operatively by clinical examination. After a mean of 9.25 years (7.25 to 11.42), 91 feet in 77 patients were available for follow-up. There was no difference in clinical or radiological outcome between the two procedures. Also, there was no difference in outcome between the two procedures in the subgroup clinically assessed as hypermobile. This study does not support the theory that a hallux valgus deformity in a patient with a clinically assessed hypermobile TMTJ-1 joint requires fusion of the first tarso-metatarsal joint.

Cite this article: Bone Joint J 2013;95-B:1222–6.


The Bone & Joint Journal
Vol. 101-B, Issue 1_Supple_A | Pages 46 - 52
1 Jan 2019
León SA Mei XY Safir OA Gross AE Kuzyk PR

Aims

The aim of this study was to report the outcome of femoral condylar fresh osteochondral allografts (FOCA) with concomitant realignment osteotomy with a focus on graft survivorship, complications, reoperation, and function.

Patients and Methods

We identified 60 patients (16 women, 44 men) who underwent unipolar femoral condylar FOCA with concomitant realignment between 1972 and 2012. The mean age of the patients was 28.9 years (10 to 62) and the mean follow-up was 11.4 years (2 to 35). Failure was defined as conversion to total knee arthroplasty, revision allograft, or graft removal. Clinical outcome was evaluated using the modified Hospital for Special Surgery (mHSS) score.


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 4 | Pages 548 - 550
1 Aug 1985
Riley D Woodyard J

Seventy-one Geomedic total knee replacements were reviewed retrospectively at a maximum of eight and a half years. The prosthesis was found to be successful in its primary aim of relieving pain. However, there was an overall failure rate of 18.3%. Analysis of the results by an actuarial method allowed comparison with other prostheses. The factors involved in failure are discussed.


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 3 | Pages 349 - 354
1 May 1984
Lettin A Kavanagh T Scales J

Between 1969 and 1971 20 prototypes of the Stanmore total knee prosthesis were used to replace severely arthritic knees in 18 patients. Seven patients died before the final follow-up and one had to have her leg amputated because of deep infection; in none of these patients had the prosthesis become loose. Ten patients (11 knees) were reviewed at least 10 years after operation. There was no significant clinical deterioration in 7 of these 11 surviving knees when the results at one year were compared with those at 10 years.


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 3 | Pages 371 - 375
1 May 1984
van der Rijt A Evans G

Nine patients have been reviewed at an average period of 22 years after a Watson-Jones tenodesis performed for chronic instability of the ankle. Only three patients had complete relief of symptoms. Two favourable early results deteriorated 7 and 10 years after operation. Radiographic examination revealed full correction of both anterior and lateral instability of the talus in only two cases. Talar tilt was controlled more successfully than increased anterior drawer movement. Long-standing instability was associated with the formation of marginal exostoses, the severity of which appeared proportional to the degree of instability.


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 1 | Pages 55 - 62
1 Jan 1984
Grimer R Karpinski M Edwards A

One hundred and three sequential Stanmore knee replacements were reviewed retrospectively on two occasions with a maximal follow-up period of nine years three months. This knee prosthesis, which is hinged, was successful in alleviating pain, stabilising an unstable knee and modestly increasing the arc of flexion. Walking capacity was increased and flexion contractures were reduced. There were seven cases of infection and four of fracture around the prosthesis. All these proved difficult to treat and two knees with both fracture and infection needed amputation. Eight knees were revised for aseptic loosening and a further 14 were found to have radiological signs of loosening. The results have been analysed by the methods advocated by Tew and Waugh and give a cumulative success rate of 80 per cent at seven years, provided success is judged solely by whether the prosthesis is still in situ. The role of the Stanmore knee as a primary arthroplasty is discussed.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1419 - 1423
1 Nov 2009
Emms NW Buckley SC Stockley I Hamer AJ Kerry RM

Between 1990 and 2000, 123 hips in 110 patients were reconstructed for aseptic loosening using impaction bone grafting with frozen, irradiated, morsellised femoral heads and cemented acetabular components. This series was reported previously at a mean follow-up of five years. We have extended this follow-up and now describe the outcome of 86 hips in 74 patients at a mean of ten years. There have been 19 revisions, comprising nine for infection, seven for aseptic loosening and three for dislocation. In surviving acetabular reconstructions, union of the graft had occurred in 64 of 67 hips (95.5%).

Survival analysis for all indications at ten years was 83.3% (95% confidence interval (CI) 68 to 89) and 71.3% (95% CI 58 to 84) at 15 years.

Acetabular reconstruction using irradiated allograft and a cemented acetabular component is an effective method of reconstruction, providing results in the medium- to long-term comparable with those of reported series where non-irradiated freshly-frozen bone was used.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 5 | Pages 775 - 777
1 Jul 2001
Rushton N


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 1005 - 1012
1 Nov 1999
Gschwend N Scheier NH Baehler AR

Between 1978 and 1986, 59 patients received a GSB III elbow prosthesis, six of them in both elbows. Rheumatoid arthritis (RA) was the underlying cause in 51 of the patients and post-traumatic osteoarthritis (PTOA) in eight. Of these, 24 patients (28 prostheses) have since died; two, both operated on bilaterally, had had their implants for more than ten years and had already been assessed for inclusion in the long-term follow-up. Two patients, each with one elbow prosthesis, have been lost to follow-up and three males who are still living (two with PTOA, one with juvenile RA) had their prosthesis removed before ten years had elapsed.

The remaining 32 patients (28 RA, 4 PTOA) with 36 GSB III elbows were examined clinically and radiologically after a mean period of 13.5 years. Pain was considerably reduced in 91.6%. Mobility was increased by 37° in those with RA and by 67° in those with PTOA.

There were three cases of aseptic loosening and three of deep infection. The main complication was disassembly of the prosthetic component in nine elbows (13.8%). This last group included two patients with postoperative fractures unrelated to the operative technique and one with neuropathic arthritis. Ulnar neuritis occurred in two patients.

Since 87.7% of all the GSB III prostheses implanted in this period remained in situ, our results are comparable with those for hip and knee arthroplasty.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 1 | Pages 60 - 66
1 Jan 1999
Schramm M Pitto RP Rohm E Hohmann D

We have examined the effect of the Wagner spherical acetabular osteotomy on preserving the joint in 38 hips with a mean follow-up of 17 years. At the time of the initial operation, 55% of patients had clinical symptoms and 30 joints showed minimal or absent radiological signs of osteoarthritis. At follow-up, 54% of patients had a good functional result.

The osteotomy improved the mean centre-edge angle from −3° to +15°, the mean anterior centre-edge angle to 23° and the acetabular head index to 75%. The obliquity of the acetabular roof decreased from 28° to 16°. One patient improved, but 14 deteriorated with joint degeneration. Of these, one progressed because of postoperative deep-tissue infection and five due to undercorrection. One patient needed total joint replacement after 14 years. At 17 years after operation, Wagner osteotomy had prevented progression of secondary arthritis in 63% of cases.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 3 | Pages 351 - 356
1 May 1995
Malkani A Settecerri J Sim F Chao E Wallrichs S

We reviewed retrospectively 50 consecutive total hip arthroplasties with proximal femoral replacement prostheses in 49 patients. All the patients had massive bone loss. There were 31 women and 18 men who had undergone a mean of 3.1 hip operations. At the last review, 15 patients had died and two had been lost to follow-up, so that 32 patients (33 hips) were available for assessment. The mean age of the patients at the time of the operation was 60.6 years. The mean length of clinical follow-up was 11.1 +/- 4 years, and mean radiographic follow-up was 7.6 +/- 3.2 years. The average preoperative Harris hip score was 46 +/- 13 points, which improved to 80 +/- 10 points after one year and to 76 +/- 16 points at the latest follow-up. The most frequent complication was dislocation, which occurred in 11 hips. Four femoral components and seven acetabular prostheses were revised because of aseptic loosening. With revision at the end point, survivorship after total hip arthroplasty with a proximal femoral replacement prosthesis was predicted to be 64% at 12 years. Although our preliminary results of hip salvage with a proximal femoral replacement prosthesis were encouraging, a longer follow-up has shown a higher rate of failure.


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 6 | Pages 803 - 806
1 Nov 1992
Kristensen O Nafei A Kjaersgaard-Andersen P Hvid I Jensen J

We have reviewed at an average period of ten years the results of 71 consecutive primary arthroplasties with the Insall-Burstein total condylar knee prosthesis in patients with rheumatoid arthritis. Their mean age at surgery was 52 years (24 to 72). At follow-up the overall results (Hospital for Special Surgery knee rating score) were excellent or good in 77%, fair in 11% and poor in 11%. There was residual pain in only 5% of patients with prostheses in situ; 58% could walk more than 500 m, and the median range of motion was 108 degrees. Eight knees had been revised. Five underwent arthrodesis because of deep infection and three needed revision arthroplasty for mechanical loosening. The crude survival rate of the arthroplasties was 89%. The presence of radiolucency around the tibial component correlated significantly with the severity of residual pain.


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 4 | Pages 664 - 666
1 Aug 1989
Tulp N Winia W

We reviewed 61 elbow synovectomies in 50 patients with rheumatoid arthritis, with follow-up varying from 4 to 10 years (mean 6.5 years). The results were graded as satisfactory in 70%, with no significant difference in the results between joints which were radiologically good before operation and those which had been destroyed. Longer term results were analysed of 27 elbow synovectomies in 22 patients followed up for over six years. The results were satisfactory in 67% of the patients in both 1981 and in 1987, with no deterioration over this period.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 68 - 72
1 Jan 2011
Motosuneya T Maruyama T Yamada H Tsuzuki N Sakai H

We reviewed 75 patients (57 men and 18 women), who had undergone tension-band laminoplasty for cervical spondylotic myelopathy (42 patients) or compression myelopathy due to ossification of the posterior longitudinal ligament (33 patients) and had been followed for more than ten years. Clinical and functional results were estimated using the Japanese Orthopaedic Association score. The rate of recovery and the level of postoperative axial neck pain were also recorded. The pre- and post-operative alignment of the cervical spine (Ishihara curve index indicating lordosis of the cervical spine) and the range of movement (ROM) of the cervical spine were also measured.

The mean rate of recovery of the Japanese Orthopaedic Association score at final follow-up was 52.1% (sd 24.6) and significant axial pain was reported by 19 patients (25.3%). Axial pain was reported more frequently in patients with ossification of the posterior longitudinal ligament than in those with cervical spondylotic myelopathy (p = 0.027). A kyphotic deformity was not seen post-operatively in any patient. The mean ROM decreased post-operatively from 32.8° (sd 12.3) to 16.2° (sd 12.3) (p < 0.001). The mean ROM ratio was 46.9% (sd 28.1) for all the patients. The mean ROM ratio was lower in patients with ossification of the posterior longitudinal ligament than in those with cervical spondylotic myelopathy (p < 0.001). Compared to those with cervical spondylotic myelopathy, patients with ossification of the posterior longitudinal ligament had less ROM and more post-operative axial neck pain.