We report a case of benign
The August 2023 Oncology Roundup360 looks at:
Aims. The aim of this study was to determine the rate of indocyanine green (ICG) staining of bone and soft-tissue tumours, as well as the stability and accuracy of ICG fluorescence imaging in detecting tumour residuals during surgery for bone and soft-tissue tumours. Methods. ICG fluorescence imaging was performed during surgery in 34 patients with bone and soft-tissue tumours. ICG was administered intravenously at a dose of 2 mg/kg over a period of 60 minutes on the day prior to surgery. The tumour stain rate and signal-to-background ratio of each tumour were post hoc analyzed. After tumour resection, the tumour bed was scanned to locate sites with fluorescence residuals, which were subsequently inspected and biopsied. Results. The overall tumour stain rate was 88% (30/34 patients), and specific stain rates included 90% for osteosarcomas and 92% for
The June 2024 Oncology Roundup. 360. looks at: Chondrosarcoma of the femur: is local recurrence influenced by the presence of an extraosseous component?; Diagnostic challenges in low-grade central osteosarcoma; Single osteotomy technique for frozen autograft (pedicled freezing) in patients with malignant bone tumours; Unplanned resection for small superficial soft-tissue sarcomas: disastrous or simply bad?; Inactivation and replantation of the knee joint: an infeasible surgical method; Active surveillance of diffuse-type tenosynovial
The August 2023 Knee Roundup. 360. looks at: Curettage and cementation of
Aims. The aims of this study were to evaluate the efficacy of preoperative denosumab in achieving prospectively decided intention of therapy in operable
The April 2015 Oncology Roundup. 360 . looks at: New hope for skull base tumours; Survival but at what cost?; Synovial sarcoma beginning to be cracked?; Wound complications facing soft-tissue sarcoma surgeons; Amputation may offer no survival benefit over reconstruction;
The April 2012 Oncology Roundup. 360 . looks at chondrosarcoma of the cervical spine, if excision margins matter, radiation-induced sarcomas,
The August 2012 Oncology Roundup. 360. looks at: prolonged symptom duration; peri-operative mortality and above-knee amputation;
The August 2015 Oncology Roundup. 360 . looks at: Glasgow prognostic score in soft-tissue sarcoma; Denosumab in
The June 2013 Oncology Roundup. 360 . looks at: whether allograft composite is superior to megaprosthesis in massive reconstruction; pain from glomus tumours; thromboembolism and orthopaedic malignancy; bone marrow aspirate and cavity lesions; metastasectomy in osteosarcoma; spinal
The April 2014 Oncology Roundup. 360 . looks at: Eyeball as good as microscope for tumour margins; when is best to stabilise femoral metastases?; fluorine does not cause bone tumours; whether
The October 2013 Oncology Roundup. 360 . looks at: En bloc resection, irradiation and re-implantation; Metastasis and osteosarcoma; Mobile spine and osteosarcoma; Denosumab miraculous for GCT; Fevers, megaprostheses and sarcomas; PET and prognosis; Canine sarcomas not so different?; Bone cement and
The June 2015 Oncology Roundup. 360 . looks at: Infection in megaprosthesis; Impressive results for mid femoral reconstruction; Revered teaching or old myth? Femoral neck protection in metastatic disease; Megaprosthesis about the knee; Malignant transformation in multiple hereditary exostoses; Fracture of intercalary bone allograft; Comorbidity and outcomes in sarcoma; A worrying turn? Use of denosumab for
Two Durasul highly crosslinked polyethylene liners were exchanged during revision surgery four and five years after implantation, respectively. The retrieved liners were evaluated macroscopically and surface analysis was performed using optical and electron microscopy. A sample of each liner was used to determine the oxidation of the material by Fourier transform infrared spectroscopy. Samples of the capsule were examined histologically. The annual wear rate was found to be 0.010 and 0.015 mm/year, respectively. Surface analysis showed very little loss of material caused by wear. Histological evaluation revealed a continuous neosynovial lining with single multinucleated foreign-body
We report our experience of treating 17 patients with benign lesions of the proximal femur with non-vascularised, autologous fibular strut grafts, without osteosynthesis. The mean age of the patients at presentation was 16.5 years (5 to 33) and they were followed up for a mean of 2.9 years (0.4 to 19.5). Histological diagnoses included simple bone cyst, fibrous dysplasia, aneurysmal bone cysts and
The LockDown device (previously called Surgilig)
is a braided polyester mesh which is mostly used to reconstruct the
dislocated acromioclavicular joint. More than 11 000 have been implanted
worldwide. Little is known about the tissue reaction to the device
nor to its wear products when implanted in an extra-articular site
in humans. This is of importance as an adverse immunological reaction
could result in osteolysis or damage to the local tissues, thereby affecting
the longevity of the implant. We analysed the histology of five LockDown implants retrieved
from five patients over the last seven years by one of the senior
authors. Routine analysis was carried out in all five cases and
immunohistochemistry in one. The LockDown device acts as a scaffold for connective tissue
which forms an investing fibrous pseudoligament. The immunological
response at the histological level seems favourable with a limited
histiocytic and
We present a retrospective study of patients suffering from a variety of benign tumours in whom external fixators were used to treat deformity and limb-length discrepancy, and for the reconstruction of bone defects. A total of 43 limbs in 31 patients (12 male and 19 female) with a mean age of 14 years (2 to 54) were treated. The diagnosis was Ollier’s disease in 12 limbs, fibrous dysplasia in 11, osteochondroma in eight,
1. The effect of implanting heterogenous anorganic bone, homogenous organic bone, autogenous compact bone from the iliac crest, and autogenous bony callus into circumscribed defects in the femur of albino rats of the Wistar strain is described. 2. Neither heterogenous anorganic bone nor homogenous organic bone appeared to induce new bone formation in a healing defect. 3. Some of the osteogenic cells of autogenous callus implants survived transplantation to a bone defect and gave rise to new bone formation. This did not occur when compact bone from autogenous iliac crest was implanted. 4. Implants of autogenous callus, autogenous compact bone, homogenous organic bone and heterogenous anorganic bone all impeded the normal development of host bone trabeculae in a healing bone defect, seemingly because they acted as physical barriers to the proliferating host callus. None of the implant materials appeared to suppress the healing reaction ofthe host. 5. Implanted homogenous organic bone was removed and replaced by host bone more quickly than was implanted heterogenous anorganic bone, and it appears to be the better material for grafting into bone defects. 6. Autogenous callus or autogenous cancellous bone is a superior implant material to autogenous compact bone and is the bone graft material of choice. 7. The absorption of all the implant materials used in this investigation was associated with the presence of multinucleated