Advertisement for orthosearch.org.uk
Results 21 - 40 of 349
Results per page:
The Bone & Joint Journal
Vol. 98-B, Issue 12 | Pages 1689 - 1696
1 Dec 2016
Cheung JPY Cheung PWH Samartzis D Cheung KMC Luk KDK

Aims. We report the use of the distal radius and ulna (DRU) classification for the prediction of peak growth (PG) and growth cessation (GC) in 777 patients with idiopathic scoliosis. We compare this classification with other commonly used parameters of maturity. Patients and Methods. The following data were extracted from the patients’ records and radiographs: chronological age, body height (BH), arm span (AS), date of menarche, Risser sign, DRU grade and status of the phalangeal and metacarpal physes. The mean rates of growth were recorded according to each parameter of maturity. PG was defined as the summit of the curve and GC as the plateau in deceleration of growth. The rates of growth at PG and GC were used for analysis using receiver operating characteristic (ROC) curves to determine the strength and cutoff values of the parameters of growth. Results. The most specific grades for PG using the DRU classification were radial grade 6 and ulnar grade 5, and for GC were radial grade 9 and ulnar grade 7. The DRU classification spanned both PG and GC, enabling better prediction of these clinically relevant stages than other methods. The rate of PG (≥ 0.7 cm/month) and GC (≤ 0.15 cm/month) was the same for girls and boys, in BH and AS measurements. Conclusion. This is the first study to note that the DRU classification can predict both PG and GC, providing evidence that it may aid the management of patients with idiopathic scoliosis. Cite this article: Bone Joint J 2016;98-B:1689–96


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 6 | Pages 875 - 879
1 Jun 2010
Puri A Gulia A Agarwal MG Reddy K

Between June 2005 and March 2008, 14 patients with a Campanacci grade-3 giant-cell tumour of the distal radius were treated by en bloc resection and reconstruction by ulnar translocation with arthrodesis of the wrist. The mean length of radius resected was 7.9 cm (5.5 to 15). All the patients were followed to bony union and 12 were available at a mean follow-up of 26 months (10 to 49). The mean time to union was four months (3 to 7) at the ulnocarpal junction and five months (3 to 8) at the ulnoradial junction. All except one patient had an excellent range of pronation and supination. The remaining patient developed a radio-ulnar synostosis. The mean Musculoskeletal Tumor Society score was 26 (87%, range 20 to 28). Three patients had a soft-tissue recurrence, but with no bony involvement. They underwent a further excision and are currently well and free from disease. Ulnar translocation provides a local vascularised bone graft to reconstruct the defect left after excision of the distal radius for giant cell tumour. It avoids the need for a microvascular procedure while retaining rotation of the forearm and good function of the hand


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 3 | Pages 404 - 409
1 May 1996
McQueen MM Hajducka C Court-Brown CM

We performed a prospective, randomised trial on 120 patients with redisplaced fractures of the distal radius comparing four methods of treatment. The four treatment groups, each containing 30 patients, were remanipulation and plaster, open reduction and bone grafting, and closed external fixation with and without mobilisation of the wrist at three weeks. The radiological results showed improvement in angulation of the distal radius for the open reduction and bone grafting group. Functional results at six weeks, three and six months and at one year, however, showed no difference between any of the four groups. The main influence on final outcome was carpal malalignment which had a statistically significant negative effect on function


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 818 - 823
1 Jun 2015
Plant CE Hickson C Hedley H Parsons NR Costa ML

We conducted an observational radiographic study to determine the inter- and intra-observer reliability of the AO classification of fractures of the distal radius. Plain posteroanterior and lateral radiographs of 456 patients with an acute fracture of the distal radius were classified by a consultant orthopaedic hand specialist and two specialist trainees, and the k coefficient for the inter- and intra-observer reliability of the type, group and subgroup classification was calculated. . Only the type of fracture (A, B or C) was found to provide substantial intra-observer reliability (k . type. 0.65). The inclusion of ‘group’ and ‘subgroup’ into the classification reduced the inter-observer reliability to fair (k. group. 0.29, k. subgroup . = 0.28) and the intra-observer reliability to moderate (k. group. 0.53, k. subgroup. 0.49). Disagreement was found to arise between specific subgroups, which may be amenable to clarification. Cite this article: Bone Joint J 2015; 97-B:818–23


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 665 - 669
1 Jul 1998
McQueen MM

A randomised, prospective study was carried out on 60 patients with unstable fractures of the distal radius to compare bridging with non-bridging external fixation using pins placed in the distal fragment of the radius. The radiological results showed significant improvement in the non-bridging group at all stages of review. In particular, normal volar tilt and carpal alignment were regained and maintained. The functional results at six weeks, three months, six months and one year showed statistically better grip strength and flexion in the non-bridging group at all stages of review. Other ranges of movement showed an early advantage in the non-bridging group. Non-bridging external fixation is the treatment of choice for unstable fractures of the distal radius which have sufficient space for the placement of pins in the distal fragment


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 778 - 785
1 Jun 2008
Varitimidis SE Basdekis GK Dailiana ZH Hantes ME Bargiotas K Malizos K

In a randomised prospective study, 20 patients with intra-articular fractures of the distal radius underwent arthroscopically- and fluoroscopically-assisted reduction and external fixation plus percutaneous pinning. Another group of 20 patients with the same fracture characteristics underwent fluoroscopically-assisted reduction alone and external fixation plus percutaneous pinning. The patients were evaluated clinically and radiologically at follow-up of 24 months. The Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire and modified Mayo wrist score were used at 3, 9, 12 and 24 months postoperatively. In the arthroscopically- and fluoroscopically-assisted group, triangular fibrocartilage complex tears were found in 12 patients (60%), complete or incomplete scapholunate ligament tears in nine (45%), and lunotriquetral ligament tears in four (20%). They were treated either arthroscopically or by open operation. Patients who underwent arthroscopically- and fluoroscopically-assisted treatment had significantly better supination, extension and flexion at all time points than those who had fluoroscopically-assisted surgery. The mean DASH scores were similar for both groups at 24 months, whereas the difference in the mean modified Mayo wrist scores remained statistically significant. Although the groups are small, it is clear that the addition of arthroscopy to the fluoroscopically-assisted treatment of intra-articular distal radius fractures improves the outcome. Better treatment of associated intra-articular injuries might also have been a reason for the improved outcome


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 102 - 107
1 Jan 2009
Zenke Y Sakai A Oshige T Moritani S Nakamura T

A total of 118 consecutive patients with a fracture of the distal radius were treated with a volar locking plate; 50 patients had no ulnar styloid fracture, 41 had a basal ulnar styloid fracture, and 27 had a fracture of the tip of the ulnar styloid. There were no significant differences in radiological and clinical results among the three groups. The outcome was good and was independent of the presence of a fracture of the ulnar styloid. A total of five patients (4.2%) had persistent ulnar-sided wrist pain at final follow-up. Nonunion of the ulnar styloid fracture did not necessarily lead to ulnar wrist pain. Patients with persistent ulnar pain had a higher mean initial ulnar variance and increased post-operative loss of ulnar variance. The presence of an associated ulnar styloid fracture of the ulnar styloid does not adversely affect the outcome in patients with a fracture of the distal radius treated by volar plating


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 749 - 754
1 Jun 2020
Jung H Park MJ Won Y Lee GY Kim S Lee JS

Aims. The aim of this study was to analyze the association between the shape of the distal radius sigmoid notch and triangular fibrocartilage complex (TFCC) foveal tear. Methods. Between 2013 and 2018, patients were retrospectively recruited in two different groups. The patient group comprised individuals who underwent arthroscopic transosseous TFCC foveal repair for foveal tear of the wrist. The control group comprised individuals presenting with various diseases around wrist not affecting the TFCC. The study recruited 176 patients (58 patients, 118 controls). The sigmoid notch shape was classified into four types (flat-face, C-, S-, and ski-slope types) and three radiological parameters related to the sigmoid notch (namely, the radius curvature, depth, and version angle) were measured. The association of radiological parameters and sigmoid notch types with the TFCC foveal tear was investigated in univariate and multivariate analyses. Receiver operating characteristic curves were used to estimate a cut-off for any statistically significant variables. Results. Univariate analysis showed that the flat-face type was more prevalent in the patients than in the control group (43% vs 21%; p = 0.002), while the C-type was lower in the patients than in the control group (3% vs 17%; p = 0.011). The depth and version angle of sigmoid notch showed a negative association with the TFCC foveal tear in the multivariate analysis (depth: odds ratio (OR) 0.380; p = 0.037; version angle: OR 0.896; p = 0.033). Estimated cut-off values were 1.34 mm for the depth (area under the curve (AUC) = 0.725) and 10.45° for the version angle (AUC = 0.726). Conclusion. The proportion of flat-face sigmoid notch type was greater in the patient group than in the control group. The depth and version angle of sigmoid notch were negatively associated with TFCC foveal injury. Cite this article: Bone Joint J 2020;102-B(6):749–754


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 5 | Pages 838 - 842
1 Nov 1989
Leung K Shen W Leung P Kinninmonth A Chang J Chan G

The conventional treatment of comminuted fractures in the distal radius has been unsatisfactory. We therefore made a prospective study using the principle of ligamentotoxis and primary cancellous bone grafting as the uniform method of treatment. Ligamentotaxis was maintained by using an external fixator for three weeks only, after which a carefully monitored programme of rehabilitation was given. We have reviewed 72 consecutive distal radial fractures after a follow-up of 7 to 40 months (average 11 months). Reduction had been maintained during healing and over 80% of patients regained full range of movement in hands, wrists and forearms with strong and pain-free wrist function. Complications were infrequent and gave no real problems. We conclude that distraction, external fixation and bone grafting appears to be an excellent method of treating comminuted fractures of the distal radius


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 629 - 637
1 May 2008
Forward DP Davis TRC Sithole JS

Fractures of the distal radius occurring in young adults are treated increasingly by open surgical techniques, partly because of concern that failure to restore the alignment of the fracture accurately may cause symptomatic post-traumatic osteoarthritis in future years. We reviewed 106 adults who had sustained a fracture of the distal radius between 1960 and 1968 and who were below the age of 40 years at the time of injury. We carried out a clinical and radiological assessment at a mean follow-up of 38 years (33 to 42). No patient had required a salvage procedure. While there was radiological evidence of post-traumatic osteoarthritis after an intra-articular fracture in 68% of patients (27 of 40), the disabilities of the arm, shoulder and hand (DASH) scores were not different from population norms, and function, as assessed by the Patient Evaluation Measure, was impaired by less than 10%. Ordinal logistic regression analysis showed a significant relationship between narrowing of the joint space and extra-articular malunion (dorsal angulation and radial shortening) as well as intra-articular injury. Multivariate analysis revealed that grip strength had fallen to 89% of that of the uninjured side in the presence of dorsal malunion, but no measure of extra-articular malunion was significantly related to either the Patient Evaluation Measure or DASH scores. While anatomical reduction is the principal aim of treatment, imperfect reduction of these fractures may not result in symptomatic arthritis in the long term, and this should be considered when counselling patients on the risks and benefits of the many treatment options available


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 4 | Pages 571 - 575
1 Jul 1995
McBirnie J Court-Brown C McQueen M

We describe a new technique for open reduction, bone grafting and fixation with a single Kirschner wire of unstable fractures of the distal radius. Of the 83 patients treated by this technique, most had regained volar tilt when seen at an average of 13 months after injury. Malunion was seen in 18 patients due either to poor placement of the graft and Kirschner wire or because of both volar and dorsal comminution. Assessment of hand and wrist function showed an average recovery of 63% of mass grip strength with an excellent return of specialised grip strength and range of movement. The advantages of this technique over closed methods include the ability to regain the volar tilt of the distal radius and to achieve reduction at any time before union of the fracture


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 6 | Pages 856 - 863
1 Aug 2000
Sanchez-Sotelo J Munuera L Madero R

We performed a prospective, randomised study on 110 patients more than 50 years old with fractures of the distal radius to compare the outcome of conservative treatment with that using remodellable bone cement (Norian skeletal repair system, SRS) and immobilisation in a cast for two weeks. Patients treated with SRS had less pain and earlier restoration of movement and grip strength. The results at one year were satisfactory in 81.54% of the SRS patients and 55.55% of the control group. The rates of malunion were 18.2% and 41.8%, respectively. There was a significant relationship between the functional and radiological results. Soft-tissue extrusion was present initially in 69.1% of the SRS patients; most deposits disappeared progressively, but persisted in 32.73% at one year. We conclude that the injection of a remodellable bone cement into the trabecular defect of fractures of the distal radius provides a better clinical and radiological result than conventional treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 670 - 672
1 Jul 1998
Flinkkilä T Nikkola-Sihto A Kaarela O Päakkö E Raatikainen T

Interobserver reliability of the AO system of classification of fractures of the distal radius was assessed using plain radiographs and CT. Five observers classified 30 Colles’-type fractures using only plain radiographs; two months later they were reclassified using CT in addition. Interobserver reliability was poor in both series when detailed classification was used. By reducing the categories to five, interobserver reliability was slightly improved, but was still poor. When only two AO types were used, the reliability was moderate using plain radiographs and good to excellent with the addition of CT. The use of CT as well as plain radiographs brings interobserver reliability to a good level in assessment of the presence or absence of articular involvement, but is otherwise of minor value in improving the interobserver reliability of the AO system of classification of fractures of the distal radius


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 3 | Pages 413 - 417
1 Apr 2002
McLauchlan GJ Cowan B Annan IH Robb JE

In a prospective, randomised controlled trial, 68 children who had a completely displaced metaphyseal fracture of the distal radius were treated either by manipulation (MUA) and application of an above-elbow cast alone or by the additional insertion of a percutaneous Kirschner (K-) wire. Full radiological follow-up to union was obtained in 65 children and 56 returned for clinical evaluation three months after injury. Maintenance of reduction was significantly better in the K-wire group and fewer follow-up radiographs were required. There was no significant difference in the clinical outcome measured three months after injury. Seven of 33 patients in the MUA group had to undergo a second procedure because of an unacceptable position compared with none of the 35 in the K-wire group (chi-squared test, p < 0.01). One patient in the K-wire group required exploration for recovery of a migrated wire. We conclude that the use of a percutaneous K-wire to augment the reduction of the fracture in children who have a completely displaced metaphyseal fracture of the distal radius is a safe and reliable way of maintaining alignment of the fracture


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 972 - 976
1 Sep 2000
Wakefield AE McQueen MM

The capacity for physiotherapy to improve the outcome after fracture of the distal radius is unproven. We carried out a randomised controlled trial on 96 patients, comparing conventional physiotherapy with a regime of home exercises. The function of the upper limb was assessed at the time of removal of the plaster cast and at three and six months after injury. Factors which may predict poor outcome in these patients were sought. Grip strength and hand function did not significantly differ between the two groups. Flexion and extension of the wrist were the only movements to improve with physiotherapy at six months (p = 0.001). Predictors of poor functional outcome were malunion and impaired function before the fracture. These patients presented with pain, decreased rotation of the forearm and low functional scores at six weeks. Our study has shown that home exercises are adequate rehabilitation after uncomplicated fracture of the distal radius, and routine referral for a course of physiotherapy should be discouraged. The role of physiotherapy in patients at high risk of a poor outcome requires further investigation


Bone & Joint Open
Vol. 1, Issue 6 | Pages 214 - 221
8 Jun 2020
Achten J Knight R Dutton SJ Costa ML Mason J Dritsaki M Appelbe D Messahel S Roland D Widnall J Perry DC

Aims. Torus fractures are the most common childhood fracture, accounting for 500,000 UK emergency attendances per year. UK treatment varies widely due to lack of scientific evidence. This is the protocol for a randomized controlled equivalence trial of ‘the offer of a soft bandage and immediate discharge’ versus ‘rigid immobilization and follow-up as per the protocol of the treating centre’ in the treatment of torus fractures . Methods. Children aged four to 15-years-old inclusive who have sustained a torus/buckle fracture of the distal radius with/without an injury to the ulna are eligible to take part. Baseline pain as measured by the Wong Baker FACES pain scale, function using the Patient-Reported Outcomes Measurement Information System (PROMIS) upper limb, and quality of life (QoL) assessed with the EuroQol EQ-5D-Y will be collected. Each patient will be randomly allocated (1:1, stratified by centre and age group (four to seven years and ≥ eight years) to either a regimen of the offer of a soft bandage and immediate discharge or rigid immobilization and follow-up as per the protocol of the treating centre. Results. At day one, three, and seven, data on pain, function, QoL, immobilization, and analgesia will be collected. Three and six weeks after injury, the main outcomes plus data on complications, resource use, and school absence will be collected. The primary outcome is the Wong-Baker FACES pain scale at three days post-randomization. All data will be obtained through electronic questionnaires completed by the participants and/or parents/guardian. Cite this article: Bone Joint Open 2020;1-6:214–221


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 2 | Pages 302 - 306
1 Mar 1991
Jakim I Pieterse H Sweet M

In a prospective study of 132 patients with an average age of 35 years, unstable intra-articular fractures of the distal radius were treated by external fixator. Only 15 cases required limited open reduction. Follow-up was for a mean of 42 months. There were few complications and 83% of patients had good or excellent results. There was a statistically significant correlation between the severity of the fracture and the clinical outcome, irrespective of radiological restoration. Articular and soft-tissue damage following violent compressive forces may lead to a degree of functional impairment


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 1 | Pages 79 - 86
1 Jan 2000
Mehta JA Bain GI Heptinstall RJ

We treated 31 intra-articular fractures of the distal radius by arthroscopically-assisted reduction and percutaneous fixation with Kirschner (K-) wires. Tears of the triangular fibrocartilage (58%), scapholunate (85%) and lunotriquetral (61%) instability and osteochondral lesions (19%) were also treated. A total of 26 patients was independently reviewed at an average of 19 months. The mean pain score was 1.3/10, the range of movement 79% and the grip strength 90% of the contralateral wrist. Using the New York Orthopaedic Hospital score, 88% were graded excellent to good. On follow-up radiographs, 65% had no step and 31% had a step of ≤1 mm. Pain was significantly related to the size of the step. There was a significant difference in the incidence of persistent scapholunate diastasis and the Leibovic and Geissler grade (p < 0.01): I (0%), II (0%), III (42%) and IV (100%). We recommend anatomical reduction and acceptance of a step of < 1 mm since the size of the step is related to the incidence of pain


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 8 | Pages 1173 - 1175
1 Nov 2001
Davidson JS Brown DJ Barnes SN Bruce CE

Torus (buckle) fractures of the distal radius are common in childhood. Based on the results of a postal questionnaire and a prospective, randomised trial, we describe a simple treatment for this injury, which saves both time and money. Over a six-month period, we randomised 201 consecutive patients with this injury to treatment with either a traditional forearm plaster-of-Paris cast or a ‘Futura-type’ wrist splint. All patients were treated for a period of three weeks, followed by clinical and radiological review. There was no difference in outcome between the two groups, and all patients had a good result. Only one patient did not tolerate the splint which was replaced by a cast. The questionnaire showed a marked variation in the way in which these injuries are treated with regard to the method and period of immobilisation, the number of follow-up visits and radiographs taken. We suggest that a ‘Futura-type’ wrist splint can be used to treat these fractures. The patient should be reviewed on the following day to confirm the diagnosis and to give appropriate advice. There is no evidence that further follow-up is required. This simple treatment has major benefits in terms of cost and reduction of the number of attendances


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 3 | Pages 385 - 389
1 May 1985
Vaughan P Lui S Harrington I Maistrelli G

The Roger Anderson external fixator was used in the treatment of unstable fractures of the distal radius in 52 patients, and the results evaluated after a follow-up averaging 58 months. The indications for its use were failure to maintain adequate closed reduction using plaster, and instability of the fracture as determined by the initial radiographs. Our radiological criteria for instability included dorsal angulation of more than 20 degrees, fractures involving the joint, radial shortening of more than 10 mm, and severe dorsal comminution. Using the Lucas modification of the Sarmiento demerit point-rating system, we found that 46 patients (89%) had good or excellent results and six (11%) were classified as fair. There were no poor results. Seven patients (14%) developed complications. None of these affected the long-term results except in one elderly woman where the pins loosened and had to be removed