The primary aim of the study was to compare the knee-specific functional outcome of robotic unicompartmental knee arthroplasty (rUKA) with manual total knee arthroplasty (mTKA) for the management of isolated medial compartment osteoarthritis. Secondary aims were to compare length of hospital stay, general health improvement, and satisfaction between rUKA and mTKA. A powered (1:3 ratio) cohort study was performed. A total of 30 patients undergoing rUKA were propensity score matched to 90 patients undergoing mTKA for isolated medial compartment arthritis. Patients were matched for age, sex, body mass index (BMI), and preoperative function. The Oxford Knee Score (OKS) and EuroQol five-dimension questionnaire (EQ-5D) were collected preoperatively and six months postoperatively. The Forgotten Joint Score (FJS) and patient satisfaction were collected six months postoperatively. Length of hospital stay was also recorded.Aims
Methods
Computer-based applications are increasingly being used by orthopaedic surgeons in their clinical practice. With the integration of technology in surgery, augmented reality (AR) may become an important tool for surgeons in the future. By superimposing a digital image on a user’s view of the physical world, this technology shows great promise in orthopaedics. The aim of this review is to investigate the current and potential uses of AR in orthopaedics. A systematic review of the PubMed, MEDLINE, and Embase databases up to January 2019 using the keywords ‘orthopaedic’ OR ‘orthopedic AND augmented reality’ was performed by two independent reviewers.Aims
Materials and Methods
The medial malleolus, once believed to be the primary stabilizer of the ankle, has been the topic of conflicting clinical and biomechanical data for many decades. Despite the relevant surgical anatomy being understood for almost 40 years, the optimal treatment of medial malleolar fractures remains unclear, whether the injury occurs in isolation or as part of an unstable bi- or trimalleolar fracture configuration. Traditional teaching recommends open reduction and fixation of medial malleolar fractures that are part of an unstable injury. However, there is recent evidence to suggest that nonoperative management of well-reduced fractures may result in equivalent outcomes, but without the morbidity associated with surgery. This review gives an update on the relevant anatomy and classification systems for medial malleolar fractures and an overview of the current literature regarding their management, including surgical approaches and the choice of implants. Cite this article: Abstract
In patients where the proximal femur shows gross deformity due
to degenerative changes or fracture, the contralateral femur is
often used to perform preoperative templating for hip arthroplasty.
However, femurs may not be symmetrical: the aim of this study was
to determine the degree of variation between hips in healthy individuals and
to determine whether it is affected by demographic parameters. CT-scan based modelling was used to examine the pelvis and bilateral
femurs of 345 patients (211 males, 134 women; mean age 62 years
(standard deviation (Aims
Materials and Methods
Asphericity of the femoral head-neck junction is common in cam-type
femoroacetabular impingement (FAI) and usually quantified using
the alpha angle on radiographs or MRI. The aim of this study was
to determine the natural alpha angle in a large cohort of patients
by continuous circumferential analysis with CT. CT scans of 1312 femurs of 656 patients were analyzed in this
cross-sectional study. There were 362 men and 294 women. Their mean
age was 61.2 years (18 to 93). All scans had been performed for
reasons other than hip disease. Digital circumferential analysis
allowed continuous determination of the alpha angle around the entire
head-neck junction. All statistical tests were conducted two-sided;
a p-value < 0.05 was considered statistically significant.Aims
Methods
Femoral stem version has a major influence on
impingement and early post-operative stability after total hip arthroplasty
(THA). The main objective of this study was to evaluate the validity
of a novel radiological method for measuring stem version. Anteroposterior
(AP) radiographs and three-dimensional CT scans were obtained for
115 patients (female/male 63/72, mean age 62.5 years (50 to 75))
who had undergone minimally invasive, cementless THA. Stem version was
calculated from the AP hip radiograph by rotation-based change in
the projected prosthetic neck–shaft (NSA*) angle using the mathematical
formula ST = arcos [tan (NSA*) / tan (135)]. We used two independent
observers who repeated the analysis after a six-week interval. Radiological
measurements were compared with 3D-CT measurements by an independent,
blinded external institute. We found a mean difference of 1.2° ( We found that femoral tilt was associated with the mean radiological
measurement error (r = 0.22, p = 0.02). The projected neck–shaft angle is a reliable method for measuring
stem version on AP radiographs of the hip after a THA. However,
a highly standardised radiological technique is required for its
precise measurement. Cite this article:
Ultraviolet (UV) light-mediated photofunctionalisation is known to improve osseointegration of pure titanium (Ti). However, histological examination of titanium alloy (Ti6Al4V), which is frequently applied in orthopaedic and dental surgery, has not yet been performed. This study examined the osseointegration of photofunctionalised Ti6Al4V implants. Ti and Ti6Al4V implants were treated with UV light, and the chemical composition and contact angle on the surfaces were evaluated to confirm photofunctionalisation. The implants were inserted into femurs in rats, and the rats were killed two or four weeks after the surgery. For histomorphometric analysis, both the bone–implant contact (BIC) ratio and the bone volume (BV) ratio were calculated from histological analysis and microcomputed tomography data.Objectives
Methods
The aim of this study was to analyse the effect of altered viewing
perspectives on the measurement of the glenopolar angle (GPA) and
the differences between these measurements made on 3D CT reconstructions
and anteroposterior (AP) scapular view radiographs. The influence of the viewing perspective on the GPA was assessed,
as were the differences in the measurements of the GPA between 3D
CT reconstructions and AP scapular view radiographs in 68 cadaveric
scapulae.Aims
Materials and Methods
Pre-operative planning for total hip replacement
(THR) is challenging in hips with severe acetabular deformities, including
those with a hypoplastic acetabulum or severe defects and in the
presence of arthrodesis or ankylosis. We evaluated whether a Rapid
Prototype (RP) model, which is a life-sized reproduction based on
three-dimensional CT scans, can determine the feasibility of THR
and provide information about the size and position of the acetabular component
in severe acetabular deformities. THR was planned using an RP model
in 21 complex hips in five men (five hips) and 16 women (16 hips)
with a mean age of 47.7 years (24 to 70) at operation. An acetabular
component was implanted successfully and THR completed in all hips.
The acetabular component used was within 2 mm of the predicted size
in 17 hips (80.9%). All of the acetabular components and femoral
stems had radiological evidence of bone ingrowth and stability at
the final follow-up, without any detectable wear or peri-prosthetic
osteolysis. The RP model allowed a simulated procedure pre-operatively
and was helpful in determining the feasibility of THR pre-operatively,
and to decide on implant type, size and position in complex THRs. Cite this article:
This study evaluates the outcome of arthroscopic femoral osteochondroplasty for cam lesions of the hip in the absence of additional pathology other than acetabular chondral lesions. We retrospectively reviewed 166 patients (170 hips) who were categorised according to three different grades of chondral damage. The outcome was assessed in each grade using the modified Harris Hip Score (MHHS) and the Non-Arthritic Hip Score (NAHS). Overall, at the last follow-up (mean 22 months, 12 to 72), the mean MHHS had improved by 15.3 points (95% confidence interval (CI), 8.9 to 21.7) and the mean NAHS by 15 points (95% CI, 9.4 to 20.5). Significantly better results were observed in hips with less severe chondral damage. Microfracture in limited chondral lesions showed superior results. Arthroscopic femoral osteochondroplasty for cam impingement with microfracture in selected cases is beneficial. The outcome correlates with the severity of acetabular chondral damage.
The April 2015 Wrist &
Hand Roundup360 looks at: Non-operative hand fracture management; From the sublime to the ridiculous?; A novel approach to carpal tunnel decompression; Osteoporosis and functional scores in the distal radius; Ulnar variance and force distribution; Tourniquets in carpal tunnel under the spotlight; Scaphoid fractures reclassified; Osteoporosis and distal radial fracture fixation; PROMISing results in the upper limb
This review examines the future of total hip arthroplasty, aiming to avoid past mistakes
The August 2014 Trauma Roundup360 looks at: On-table CT for calcaneal fractures; timing of femoral fracture surgery and outcomes; salvage arthroplasty for failed internal fixation of the femoral neck; screw insertion in osteoporotic bone; fibular intramedullary nailing on the ascendant; posterior wall acetabular fractures not all that innocent; bugs, plating and resistance and improving outcomes in olecranon tension band wiring.
Few studies have examined the order in which
a spinal osteotomy and total hip replacement (THR) are to be performed
for patients with ankylosing spondylitis. We have retrospectively
reviewed 28 consecutive patients with ankylosing spondylitis who
underwent both a spinal osteotomy and a THR from September 2004
to November 2012. In the cohort 22 patients had a spinal osteotomy
before a THR (group 1), and six patients had a THR before a spinal
osteotomy (group 2). The mean duration of follow-up was 3.5 years
(2 to 9). The spinal sagittal Cobb angle of the vertebral osteotomy
segment was corrected from a pre-operative kyphosis angle of 32.4
(SD 15.5°) to a post-operative lordosis 29.6 (SD 11.2°) (p <
0.001). Significant improvements in pain, function and range of
movement were observed following THR. In group 2, two of six patients
had an early anterior dislocation. The spinal osteotomy was performed
two weeks after the THR. At follow-up, no hip has required revision
in either group. Although this non-comparative study only involved
a small number of patients, given our experience, we believe a spinal osteotomy
should be performed prior to a THR, unless the deformity is so severe
that the procedure cannot be performed. Cite this article:
The orientation of the acetabular component can
influence both the short- and long-term outcomes of total hip replacement
(THR). We performed a prospective, randomised, controlled trial
of two groups, comprising of 40 patients each, in order to compare
freehand introduction of the component with introduction using the transverse
acetabular ligament (TAL) as a reference for anteversion. Anteversion
and inclination were measured on pelvic radiographs. With respect to anteversion, in the freehand group 22.5% of the
components were outside the safe zone With respect to inclination, in the freehand group 37.5% of the
components were outside the safe zone The transverse acetabular ligament may be used to obtain the
appropriate anteversion when introducing the acetabular component
during THR, but not acetabular component inclination. Cite this article:
We used immediate post-operative The bending angles in the sagittal and axial planes were significantly
greater but the coronal-bending angle was significantly less in
the transtibial group than in the anteromedial portal and outside-in
groups (p <
0.001 each). The mean length of the femoral tunnel
in all three planes was significantly greater in the transtibial
group than the anteromedial portal and outside-in groups (p <
0.001 each), but all mean tunnel lengths in the three groups exceeded
30 mm. The only significant difference was the coronal graft- bending
angle in the anteromedial portal and outside-in groups (23.5° Compared with the transtibial technique, the anteromedial portal
and outside-in techniques may reduce the graft-bending stress at
the opening of the femoral tunnel. Despite the femoral tunnel length
being shorter in the anteromedial portal and outside-in techniques
than in the transtibial technique, a femoral tunnel length of more than
30 mm in the anteromedial portal and outside-in techniques may be
sufficient for the graft to heal. Cite this article:
We describe a patient in whom an initially intact sciatic nerve became rapidly encased in heterotopic bone formed in the abductor compartment after reconstruction of the posterior wall of the acetabulum following fracture. Prompt excision and neural release followed by irradiation and administration of indometacin resulted in a full neurological recovery and no recurrence 27 months later.