The poor reporting and use of statistical methods in orthopaedic papers has been widely discussed by both clinicians and statisticians. A detailed review of research published in general orthopaedic journals was undertaken to assess the quality of experimental design, statistical analysis and reporting. A representative sample of 100 papers was assessed for compliance to CONSORT and STROBE guidelines and the quality of the statistical reporting was assessed using a validated questionnaire. Overall compliance with CONSORT and STROBE guidelines in our study was 59% and 58% respectively, with very few papers fulfilling all criteria. In 37% of papers patient numbers were inadequately reported; 20% of papers introduced new statistical methods in the ‘results’ section not previously reported in the ‘methods’ section, and 23% of papers reported no measurement of error with the main
We retrospectively compared the
Fixed flexion deformities are common in osteoarthritic
knees that are indicated for total knee arthroplasty. The lack of
full extension at the knee results in a greater force of quadriceps
contracture and energy expenditure. It also results in slower walking
velocity and abnormal gait mechanics, overloading the contralateral
limb. Residual flexion contractures after TKA have been associated
with poorer functional scores and
Clinicians are often asked by patients, “When
can I drive again?” after lower limb injury or surgery. This question
is difficult to answer in the absence of any guidelines. This review
aims to collate the currently available evidence and discuss the
factors that influence the decision to allow a patient to return
to driving. Medline, Web of Science, Scopus,
and EMBASE were searched using the following terms: ‘brake reaction
time’, ‘brake response time’, ‘braking force’, ‘brake pedal force’,
‘resume driving’, ‘rate of application of force’, ‘driving after
injury’, ‘joint replacement and driving’, and ‘fracture and driving’.
Of the relevant literature identified, most studies used the brake
reaction time and total brake time as the
The Bologna–Oxford (BOX) total ankle replacement
(TAR) was developed with the aim of achieving satisfactory pain-free
movement of the ankle. To date, only one single multicentre study
has reported its clinical results. The aim of this study was to
conduct an independent review of its mid-term results. We retrospectively reviewed a total of 60 prospectively followed
patients in whom 62 BOX TARs had been implanted between 2004 and
2008. We used the American Orthopedic Foot and Ankle Society (AOFAS)
score to assess the clinical results. Standardised radiographs taken
at the time of final follow-up were analysed by two observers. The
overall survival was 91.9% at a mean follow-up of 42.5 months (24
to 71). The mean AOFAS score had improved from 35.1 points (. sd. 16.6;
4 to 73) pre-operatively to 78.0 (. sd. 10.7; 57 to 100) at
final follow-up (p <
0.01). Tibial radiolucencies <
2 mm in
width were seen around 16 TARs. Talar radiolucencies <
2 mm were
seen around four TARs. A total of 47 patients (78.3%) were very
satisfied or satisfied with the
There has been a substantial increase in the
number of hip and knee prostheses implanted in recent years, with
a consequent increase in the number of revisions required. Total
femur replacement (TFR) following destruction of the entire femur,
usually after several previous revision operations, is a rare procedure
but is the only way of avoiding amputation. Intramedullary femur
replacement (IFR) with preservation of the femoral diaphysis is
a modification of TFR. Between 1999 and 2010, 27 patients with non-oncological
conditions underwent surgery in our department with either IFR (n
= 15) or TFR (n = 12) and were included in this study retrospectively.
The aim of the study was to assess the indications, complications
and
Tantalum (Ta) trabecular metal components are increasingly used
to reconstruct major bone defects in revision arthroplasty surgery.
It is known that some metals such as silver have antibacterial properties.
Recent reports have raised the question regarding whether Ta components
are protective against infection in revision surgery. This laboratory
study aimed to establish whether Ta has intrinsic antibacterial
properties against planktonic bacteria, or the ability to inhibit
biofilm formation. Equal-sized pieces of Ta and titanium (Ti) acetabular components
were sterilised and incubated with a low dose inoculum of either Aims
Materials and Methods
We present the results of correcting a double or triple curve
adolescent idiopathic scoliosis using a convex segmental pedicle
screw technique. We reviewed 191 patients with a mean age at surgery of 15 years
(11 to 23.3). Pedicle screws were placed at the convexity of each
curve. Concave screws were inserted at one or two cephalad levels
and two caudal levels. The mean operating time was 183 minutes (132
to 276) and the mean blood loss 0.22% of the total blood volume
(0.08% to 0.4%). Multimodal monitoring remained stable throughout
the operation. The mean hospital stay was 6.8 days (5 to 15).Aims
Patients and Methods
Although bone and soft-tissue sarcomas are rare, early diagnosis and prompt referral to a specialised unit offers the best chance of a successful
Introduction. Negative pressure wound therapy (NPWT) and vessel loop assisted
closure are two common methods used to assist with the closure of
fasciotomy wounds. This retrospective review compares these two
methods using a primary
To evaluate the incidence of primary venous thromboembolism (VTE),
epidural haematoma, surgical site infection (SSI), and 90-day mortality
after elective spinal surgery, and the effect of two protocols for
prophylaxis. A total of 2181 adults underwent 2366 elective spinal procedures
between January 2007 and January 2012. All patients wore anti-embolic
stockings, mobilised early and were kept adequately hydrated. In
addition, 29% (689) of these were given low molecular weight heparin
(LMWH) while in hospital. SSI surveillance was undertaken using the
Centers for Disease Control and Prevention criteria.Aims
Patients and Methods
We report the use of porous metal acetabular
revision shells in the treatment of contained bone loss. The
Preservation of both anterior and posterior cruciate ligaments in total knee arthroplasty (TKA) can lead to near-normal post-operative joint mechanics and improved knee function. We hypothesised that a patient-specific bicruciate-retaining prosthesis preserves near-normal kinematics better than standard off-the-shelf posterior cruciate-retaining and bicruciate-retaining prostheses in TKA. We developed the validated models to evaluate the post-operative kinematics in patient-specific bicruciate-retaining, standard off-the-shelf bicruciate-retaining and posterior cruciate-retaining TKA under gait and deep knee bend loading conditions using numerical simulation.Objectives
Methods
This pilot study analysed the