Advertisement for orthosearch.org.uk
Results 361 - 380 of 385
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1638 - 1644
1 Dec 2007
Nath RK Lyons AB Melcher SE Paizi M

The medial rotation contracture caused by weak external rotation secondary to obstetric brachial plexus injury leads to deformation of the bones of the shoulder. Scapular hypoplasia, elevation and rotation deformity are accompanied by progressive dislocation of the humeral head. Between February and August 2005, 44 children underwent a new surgical procedure called the ‘triangle tilt’ operation to correct this bony shoulder deformity. Surgical levelling of the distal acromioclavicular triangle combined with tightening of the posterior glenohumeral capsule (capsulorrhaphy) improved shoulder function and corrected the glenohumeral axis in these patients. The posture of the arm at rest was improved and active external rotation increased by a mean of 53° (0° to 115°) in the 40 children who were followed up for more than one year.

There was a mean improvement of 4.9 points (1.7 to 8.3) of the Mallet shoulder function score after surgical correction of the bony deformity.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 984 - 985
1 Jul 2005
Lowry CA Donoghue VB O’Herlihy C Murphy JF

We wished to establish whether delivery by Caesarean section influenced the incidence of developmental dysplasia of the hip in term breech infants compared with those delivered vaginally. We used maternal charts, singleton term breech presentation, mode of delivery and incidence of developmental dysplasia of the hip for births between January 1997 and October 2002.

During the study period 46 089 infants were born. We analysed a total of 941 breech infants of whom 756 were delivered by Caesarean section (515 pre-labour, 241 intrapartum) and 185 vaginally. The incidence of developmental dysplasia of the hip according to the mode of delivery was 19 of 515 (3.69%) following pre-labour Caesarean section, 16 of 241 (6.64%) for intrapartum Caesarean section and 15 of 185 (8.11%) after vaginal delivery. There was a lower incidence of developmental dysplasia of the hip among those infants delivered by elective Caesarean section compared with those delivered vaginally (p < 0.02). These results demonstrate a significantly lower incidence of developmental dysplasia of the hip in term singleton breech births delivered by elective, pre-labour Caesarean section and suggest that labour and delivery influence hip stability in predisposed infants.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1178 - 1182
1 Sep 2006
Stanley JK Penn DS Wasseem M

Surgical access to the head of the radius is usually performed through a lateral approach. We present an alternative technique through a modified posterior approach which was developed following dissections of 22 human cadavers. An osteotomy of the supinator tuberosity was performed and reflected as a single unit with the attached annular ligament. Excellent exposure of the head of the radius was achieved, replacement of the head was undertaken and the osteotomy site repaired. The elbows were stable and had a full range of movement. The approach was then carried out on 13 patients for elective replacement of the head and was found to be safe and reproducible. In the patient group all osteotomies united, the elbows were stable and had an improved range of supination and pronation. There was no change in flexion and extension of the elbow. Complications included a haematoma and a reflex sympathetic dystrophy.

The modified posterior approach provides excellent access to the head and neck of the radius, gives good stability of the elbow and allows early mobilisation of the joint.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 3 | Pages 265 - 271
1 Mar 2008
Mandalia V Eyres K Schranz P Toms AD

Evaluation of patients with painful total knee replacement requires a thorough clinical examination and relevant investigations in order to reach a diagnosis. Awareness of the common and uncommon problems leading to painful total knee replacement is useful in the diagnostic approach. This review article aims to act as a guide to the evaluation of patients with painful total knee replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 6 | Pages 760 - 764
1 Jun 2006
Dotzis A Cochu G Mabit C Charissoux JL Arnaud JP

Excision is not a suitable treatment for all comminuted fractures of the radial head. In elbows where instability can be predicted, a replacement arthroplasty of the radial head is more effective. The aim of this paper was to present the medium-term results of the Judet floating radial head prosthesis.

This operation was performed on 14 patients between 1992 and 2003, of whom 12 were reviewed at a mean follow-up of five years and three months (1 to 12 years). The outcome was assessed using the Mayo elbow performance score and a modified Disability of Arm Shoulder Hand (DASH) questionnaire. There were six excellent results, four good, one fair and one poor, as graded by the Mayo score. The mean DASH score was 23.9/100 (0 to 65.8/100). The only significant complication occurred in one patient who developed a severe complex regional pain syndrome. There were no patients with secondary instability of the elbow, implant loosening, cubitus valgus, osteoporosis of the capitellum, or pain in the forearm and wrist. Our experience, combined with that of other authors using this device, has encouraged us to continue using the Judet prosthesis in comminuted fractures of the elbow where instability is a potential problem.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 1 | Pages 50 - 56
1 Jan 2008
Muijs SPJ Dijkstra PDS Bos CFA

We performed a retrospective study to assess the long-term outcome of non-augmented anatomical direct repair of the lateral ankle ligaments, as originally described by Duquennoy et al, for the treatment of chronic lateral instability of the ankle. This procedure aims to restore stability by the re-insertion and tightening of the original talofibular and calcaneofibular ligaments without division of the ligament. We examined the outcome in terms of the post-operative quality of life, the function of the joint and the development of osteoarthritis.

Between 1985 and 2002, 23 patients (11 males, 12 females) with a mean age of 32 years (15 to 58) who had undergone this procedure completed the Short-Form 36 assessment of quality of life and the Olerud and Molander Ankle score for the subjective evaluation of symptoms. Clinical re-evaluation, including examination of the ankle and the completion of the American Orthopaedic Foot and Ankle Society questionnaire was performed on 21 patients after a mean follow-up of 13 years (3 to 22.2). At the final follow-up radiographs of both ankles were taken to assess the development of osteoarthritis.

The mean total Short-Form 36 and Olerud and Molander Ankle scores in 23 patients at final follow-up were 79.6 points (37 to 100) and 81.6 points (40 to 100), respectively. The mean total post-operative American Orthopaedic Foot and Ankle Society score in 21 patients was 89.7 points (72 to 100). We found a significant post-operative reduction in talar tilt and anterior drawer sign (chi-squared test, p < 0.001). The functional outcome of the procedure was excellent in ten patients (48%), good in seven (33%) and fair in four (19%). The results in terms of ankle function and stability did not deteriorate with time and there was little restriction in movement.

This procedure is simple and effective with a very low rate of complications.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1660 - 1665
1 Dec 2007
Krause F Windolf M Schwieger K Weber M

A cavovarus foot deformity was simulated in cadaver specimens by inserting metallic wedges of 15° and 30° dorsally into the first tarsometatarsal joint. Sensors in the ankle joint recorded static tibiotalar pressure distribution at physiological load.

The peak pressure increased significantly from neutral alignment to the 30° cavus deformity, and the centre of force migrated medially. The anterior migration of the centre of force was significant for both the 15° (repeated measures analysis of variance (ANOVA), p = 0.021) and the 30° (repeated measures ANOVA, p = 0.007) cavus deformity. Differences in ligament laxity did not influence the peak pressure.

These findings support the hypothesis that the cavovarus foot deformity causes an increase in anteromedial ankle joint pressure leading to anteromedial arthrosis in the long term, even in the absence of lateral hindfoot instability.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 330 - 334
1 Mar 2007
Cesar M Roussanne Y Bonnel F Canovas F

Between 1993 and 2002, 58 GSB III total elbow replacements were implanted in 45 patients with rheumatoid arthritis by the same surgeon. At the most recent follow-up, five patients had died (five elbows) and six (nine elbows) had been lost to follow-up, leaving 44 total elbow replacements in 34 patients available for clinical and radiological review at a mean follow-up of 74 months (25 to 143). There were 26 women and eight men with a mean age at operation of 55.7 years (24 to 77).

At the latest follow-up, 31 excellent (70%), six good (14%), three fair (7%) and four poor (9%) results were noted according to the Mayo elbow performance score. Five humeral (11%) and one ulnar (2%) component were loose according to radiological criteria (type III or type IV). Of the 44 prostheses, two (5%) had been revised, one for type-IV humeral loosening after follow-up for ten years and one for fracture of the ulnar component. Seven elbows had post-operative dysfunction of the ulnar nerve, which was transient in five and permanent in two.

Despite an increased incidence of loosening with time, the GSB III prosthesis has given favourable mid-term results in patients with rheumatoid arthritis.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 490 - 494
1 Apr 2007
Arimitsu S Murase T Hashimoto J Oka K Sugamoto K Yoshikawa H Moritomo H

We have measured the three-dimensional patterns of carpal deformity in 20 wrists in 20 rheumatoid patients in which the carpal bones were shifted ulnarwards on plain radiography. Three-dimensional bone models of the carpus and radius were created by computerised tomography with the wrist in the neutral position. The location of the centroids and rotational angle of each carpal bone relative to the radius were calculated and compared with those of ten normal wrists.

In the radiocarpal joint, the proximal row was flexed and the centroids of all carpal bones translocated in an ulnar, proximal and volar direction with loss of congruity. In the midcarpal joint, the distal row was extended and congruity generally well preserved. These findings may facilitate more positive use of radiocarpal fusion alone for the deformed rheumatoid wrist.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 516 - 520
1 Apr 2007
Bufquin T Hersan A Hubert L Massin P

We used an inverted shoulder arthroplasty in 43 consecutive patients with a mean age of 78 years (65 to 97) who had sustained a three- or four-part fracture of the upper humerus. All except two were reviewed with a mean follow-up of 22 months (6 to 58).

The clinical outcome was satisfactory with a mean active anterior elevation of 97° (35° to 160°) and a mean active external rotation in abduction of 30° (0° to 80°). The mean Constant and the mean modified Constant scores were respectively 44 (16 to 69) and 66% (25% to 97%). Complications included three patients with reflex sympathetic dystrophy, five with neurological complications, most of which resolved, and one with an anterior dislocation. Radiography showed peri-prosthetic calcification in 36 patients (90%), displacement of the tuberosities in 19 (53%) and a scapular notch in ten (25%). Compared with conventional hemiarthroplasty, satisfactory mobility was obtained despite frequent migration of the tuberosities. However, long-term results are required before reverse shoulder arthroplasty can be recommended as a routine procedure in complex fractures of the upper humerus in the elderly.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 6 | Pages 709 - 716
1 Jun 2007
Mulford JS Wakeley CJ Eldridge JDJ

Chronic patellofemoral instability can be a disabling condition. Management of patients with this condition has improved owing to our increased knowledge of the functional anatomy of the patellofemoral joint. Accurate assessment of the underlying pathology in the unstable joint enables the formulation of appropriate treatment. The surgical technique employed in patients for whom non-operative management has failed should address the diagnosed abnormality. We have reviewed the literature on the stabilising features of the patellofemoral joint, the recommended investigations and the appropriate forms of treatment.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 597 - 604
1 May 2008
Selmi TAS Verdonk P Chambat P Dubrana F Potel J Barnouin L Neyret P

Autologous chondrocyte implantation is an established method of treatment for symptomatic articular defects of cartilage. CARTIPATCH is a monolayer-expanded cartilage cell product which is combined with a novel hydrogel to improve cell phenotypic stability and ease of surgical handling. Our aim in this prospective, multicentre study on 17 patients was to investigate the clinical, radiological, arthroscopic and histological outcome at a minimum follow-up of two years after the implantation of autologous chondrocytes embedded in a three-dimensional alginate-agarose hydrogel for the treatment of chondral and osteochondral defects.

Clinically, all the patients improved significantly. Patients with lesions larger than 3 cm2 improved significantly more than those with smaller lesions. There was no correlation between the clinical outcome and the body mass index, age, duration of symptoms and location of the defects. The mean arthroscopic International Cartilage Repair Society score was 10 (5 to 12) of a maximum of 12. Predominantly hyaline cartilage was seen in eight of the 13 patients (62%) who had follow-up biopsies.

Our findings suggest that autologous chondrocyte implantation in combination with a novel hydrogel results in a significant clinical improvement at follow-up at two years, more so for larger and deeper lesions. The surgical procedure is uncomplicated, and predominantly hyaline cartilage-like repair tissue was observed in eight patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1561 - 1566
1 Dec 2007
Nowicki P Chaudhary H

Avascular necrosis of the femoral head creates considerable morbidity in successful renal transplant recipients who are generally young and expect active lifestyles. Total hip replacement is considered the treatment of choice in these patients, but surgeons may be wary because of a supposed increase in the risk of infection and other complications.

A review of the literature reveals that cemented hip arthroplasty provides good to excellent functional outcomes for renal transplant patients. Most authors have found that the risk of infection is not increased despite chronic immunosuppression, but the rates of general complications are and should be anticipated and treated. There is a high rate of early failure in these patients because of their young age and diffuse osteopenia as a result of secondary hyperparathyroidism related to the underlying renal disease and chronic steroid use. Recent studies have found that despite decreased bone stock in these patients, porous-coated prostheses are not contraindicated.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 44 - 48
1 Jan 2006
Keene G Simpson D Kalairajah Y

Twenty patients underwent simultaneous bilateral medial unicompartmental knee arthroplasty. Pre-operative hip-knee-ankle alignment and valgus stress radiographs were used to plan the desired post-operative alignment of the limb in accordance with established principles for unicompartmental arthroplasty. In each patient the planned alignment was the same for both knees. Overall, the mean planned post-operative alignment was to 2.3° of varus (0° to 5°).

The side and starting order of surgery were randomised, using conventional instrumentation for one knee and computer-assisted surgery for the opposite side.

The mean variation between the pre-operative plan and the achieved correction in the navigated and the non-navigated limb was 0.9° (sd 1.1; 0° to 4°) and 2.8° (sd 1.4; 1° to 7°), respectively. Using the Wilcoxon signed rank test, we found the difference in variation statistically significant (p < 0.001).

Assessment of lower limb alignment in the non-navigated group revealed that 12 (60%) were within ± 2° of the pre-operative plan, compared to 17 (87%) of the navigated cases.

Computer-assisted surgery significantly improves the post-operative alignment of medial unicompartmental knee arthroplasty compared to conventional techniques in patients undergoing bilateral simultaneous arthroplasty. Improved alignment after arthroplasty is associated with better function and increased longevity.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1470 - 1477
1 Nov 2007
Balg F Boileau P

There is no simple method available to identify patients who will develop recurrent instability after an arthroscopic Bankart procedure and who would be better served by an open operation.

We carried out a prospective case-control study of 131 consecutive unselected patients with recurrent anterior shoulder instability who underwent this procedure using suture anchors. At follow-up after a mean of 31.2 months (24 to 52) 19 (14.5%) had recurrent instability. The following risk factors were identified: patient age under 20 years at the time of surgery; involvement in competitive or contact sports or those involving forced overhead activity; shoulder hyperlaxity; a Hill-Sachs lesion present on an anteroposterior radiograph of the shoulder in external rotation and/or loss of the sclerotic inferior glenoid contour.

These factors were integrated in a 10-point pre-operative instability severity index score and tested retrospectively on the same population. Patients with a score over 6 points had an unacceptable recurrence risk of 70% (p < 0.001). On this basis we believe that an arthroscopic Bankart repair is contraindicated in these patients, to whom we now suggest a Bristow-Latarjet procedure instead.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 180 - 185
1 Feb 2007
Koëter S Diks MJF Anderson PG Wymenga AB

An abnormal lateral position of the tibial tuberosity causes distal malalignment of the extensor mechanism of the knee and can lead to lateral tracking of the patella causing anterior knee pain or objective patellar instability, characterised by recurrent dislocation. Computer tomography is used for a precise pre-operative assessment of the tibial tubercle-trochlear groove distance. A distance of more than 15 mm is considered to be pathological and an indication for surgery in symptomatic patients.

In a prospective study we performed a subtle transfer of the tibial tuberosity according to the information gained from the pre-operative CT scan. This method was applied to two groups of patients, those with painful lateral tracking of the patella, and those with objective patellar instability. We evaluated the clinical results in 30 patients in each group. The outcome was documented at 3, 12 and 24 months using the Lysholm scale, the Kujala score, and a visual analogue pain score.

Post-operatively, all but one patient in the instability group who had a patellar dislocation requiring further surgery reported good improvement with no further subluxation or dislocation. All patients in both groups had a marked improvement in pain and functional score. Two patients sustained a tibial fracture six and seven weeks after surgery. One patient suffered a per-operative fracture of the tibial tubercle which later required further fixation.

If carefully performed, this type of transfer of the tibial tubercle appears to be a satisfactory technique for the treatment of patients with an increased tibial tubercle-trochlear groove distance and who present with symptoms related to lateral maltracking of the patella.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 4 | Pages 544 - 547
1 Apr 2005
Katz DA Kim Y Millis MB

We treated eight dysplastic acetabula in six skeletally mature patients with Down’s syndrome by a modified Bernese periacetabular osteotomy. The mean age at the time of surgery was 16.5 years (12.8 to 28.5). Mean length of follow-up was five years (2 to 10.4).

Pre-operatively the mean (Tönnis) acetabular angle was 28°, the centre-edge angle was −9°, and the extrusion index was 60%; post-operatively they were 3°, 37°, and 17%, respectively. Two patients with post-operative (Tönnis) acetabular angles > 10° developed subluxation post-operatively and required secondary varus derotation femoral osteotomies. Another patient developed a late labral tear which was treated arthroscopically. All eight hips remain clinically stable, and are either asymptomatic or symptomatically improved.

These results suggest that the modified Bernese periacetabular osteotomy can be used successfully in the treatment of acetabular dysplasia in patients with Down’s syndrome.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 697 - 707
1 Jun 2008
Fraser-Moodie JA Shortt NL Robinson CM

Injuries to the acromioclavicular joint are common but underdiagnosed. Sprains and minor subluxations are best managed conservatively, but there is debate concerning the treatment of complete dislocations and the more complex combined injuries in which other elements of the shoulder girdle are damaged. Confusion has been caused by existing systems for classification of these injuries, the plethora of available operative techniques and the lack of well-designed clinical trials comparing alternative methods of management. Recent advances in arthroscopic surgery have produced an even greater variety of surgical options for which, as yet, there are no objective data on outcome of high quality. We review the current concepts of the treatment of these injuries.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1492 - 1496
1 Nov 2006
Gordon GS Simkiss DE

We reviewed the evidence for hip surveillance in children with cerebral palsy from the published literature.

Publications were identified using the Cochrane controlled trials register, the MEDLINE, EMBASE and CINAHL databases and by hand searching key journals and their references. Studies were included if they reported the frequency, associated risk factors or surveillance measures undertaken to identify subluxation or dislocation of the hip in children with cerebral palsy. Assessment of the quality of the methodology was undertaken independently by two researchers.

Four studies described the natural history, incidence and risk factors for dislocation of the hip. Two reported their surveillance results. Approximately 60% of children who were not walking by five years of age were likely to develop subluxation of the hip, with the greatest risk in those with severe neurological involvement. The introduction of surveillance programmes allowed earlier identification of subluxation and reduced the need for surgery on dislocated hips.

Surveillance can identify children most at risk of subluxation using radiological methods which are widely available.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1158 - 1164
1 Sep 2007
Lusty PJ Watson A Tuke MA Walter WL Walter WK Zicat B

We studied 33 third generation, alumina ceramic-on-ceramic bearings retrieved from cementless total hip replacements after more than six months in situ. Wear volume was measured with a Roundtest machine, and acetabular orientation from the anteroposterior pelvic radiograph. The overall median early wear rate was 0.1 mm3/yr for the femoral heads, and 0.04 mm3/yr for the acetabular liners. We then excluded hips where the components had migrated. In this stable subgroup of 22 bearings, those with an acetabular anteversion of < 15° (seven femoral heads) had a median femoral head wear rate of 1.2 mm3/yr, compared with 0 mm3/yr for those with an anteversion of ≥15° (15 femoral heads, p < 0.001). Even under edge loading, wear volumes with ceramic-on-ceramic bearings are small in comparison to other bearing materials. Low acetabular anteversion is associated with greater wear.