Uncemented mobile bearing designs in medial unicompartmental knee arthroplasty (UKA) have seen an increase over the last decade. However, there are a lack of large-scale studies comparing survivorship of these specific designs to commonly used cemented mobile and fixed bearing designs. The aim of this study was to evaluate the survivorship of these designs. A total of 21,610 medial UKAs from 2007 to 2018 were selected from the Dutch Arthroplasty Register. Multivariate Cox regression analyses were used to compare uncemented mobile bearings with cemented mobile and fixed bearings. Adjustments were made for patient and surgical factors, with their interactions being considered. Reasons and type of revision in the first two years after surgery were assessed.Aims
Methods
Although about 200 000 cementless Zweymüller-Alloclassic total hip arthroplasties (THAs) were carried out worldwide in the last decade, the survival analysis of these prostheses was not available in the 2000 report of the Swedish national hip arthroplasty registry. We report a prospective survivorship analysis of 200 consecutive grit-blasted cementless Alloclassic primary THAs carried out since 1988. Using surgical, clinical and radiological endpoints for the stem and the threaded cup the
1. Stainless steel mould arthroplasty of the knee is described and a
We aimed to compare the implant survival, complications, readmissions, and mortality of Vancouver B2 periprosthetic femoral fractures (PFFs) treated with internal fixation with that of B1 PFFs treated with internal fixation and B2 fractures treated with revision arthroplasty. We retrospectively reviewed the data of 112 PFFs, of which 47 (42%) B1 and 27 (24%) B2 PFFs were treated with internal fixation, whereas 38 (34%) B2 fractures underwent revision arthroplasty. Decision to perform internal fixation for B2 PFFs was based on specific radiological (polished femoral components, intact bone-cement interface) and clinical criteria (low-demand patient). Median follow-up was 36.4 months (24 to 60). Implant survival and mortality over time were estimated with the Kaplan-Meier method. Adverse events (measured with a modified Dindo-Clavien classification) and 90-day readmissions were additionally compared between groups.Aims
Methods
Satisfactory selection criteria are essential for the successful outcome of unicompartmental knee arthroplasty (UCA). We report the frequency of revision of the Oxford medial unicompartmental arthroplasty in knees previously treated for anteromedial osteoarthritis by high tibial osteotomy (HTO). The combined results from three sources were used to allow statistical analysis of this uncommon subgroup. In the combined series of 631 knees (507 patients) which had medial unicompartmental replacement, 613 were primary procedures and 18 were for a failed HTO. The mean follow-up times of the two groups were similar (5.8 years and 5.4 years, respectively). At review, 19 (3.1%) of the primary procedures and five (27.8%) of those undertaken for a failed HTO had been revised to total knee replacement. Survival analysis revealed the
Limb alignment in total knee arthroplasty (TKA) influences periarticular soft-tissue tension, biomechanics through knee flexion, and implant survival. Despite this, there is no uniform consensus on the optimal alignment technique for TKA. Neutral mechanical alignment facilitates knee flexion and symmetrical component wear but forces the limb into an unnatural position that alters native knee kinematics through the arc of knee flexion. Kinematic alignment aims to restore native limb alignment, but the safe ranges with this technique remain uncertain and the effects of this alignment technique on component survivorship remain unknown. Anatomical alignment aims to restore predisease limb alignment and knee geometry, but existing studies using this technique are based on cadaveric specimens or clinical trials with limited follow-up times. Functional alignment aims to restore the native plane and obliquity of the joint by manipulating implant positioning while limiting soft tissue releases, but the results of high-quality studies with long-term outcomes are still awaited. The drawbacks of existing studies on alignment include the use of surgical techniques with limited accuracy and reproducibility of achieving the planned alignment, poor correlation of intraoperative data to long-term functional outcomes and implant survivorship, and a paucity of studies on the safe ranges of limb alignment. Further studies on alignment in TKA should use surgical adjuncts (e.g. robotic technology) to help execute the planned alignment with improved accuracy, include intraoperative assessments of knee biomechanics and periarticular soft-tissue tension, and correlate alignment to long-term functional outcomes and survivorship.
The objective of this retrospective study was to correlate the Bado and Jupiter classifications with long-term results after operative treatment of Monteggia fractures in adults and to determine prognostic factors for functional outcome. Of 63 adult patients who sustained a Monteggia fracture in a
We present the clinical and radiological results at a minimum follow-up of 20 years using a second-generation uncemented total hip arthroplasty (THA). These results are compared to our previously published results using a first-generation hip arthroplasty followed for 20 years. A total of 62 uncemented THAs in 60 patients were performed between 1993 and 1994. The titanium femoral component used in all cases was a Taperloc with a reduced distal stem. The acetabular component was a fully porous coated threaded hemispheric titanium shell (T-Tap ST). The outcome of every femoral and acetabular component with regard to retention or revision was determined for all 62 THAs. Complete clinical follow-up at a minimum of 20 years was obtained on every living patient. Radiological follow-up was obtained on all but one.Aims
Methods
We have carried out a long-term survival analysis of a prospective, randomised trail comparing cemented with cementless fixation of press-fit condylar primary total knee replacements. A consecutive series of 501 replacements received either cemented (219 patients, 277 implants) or cementless (177 patients, 224 implants) fixation. The patients were contacted at a mean follow-up of 7.4 years (2.7 to 13.0) to establish the rate of survival of the implant. The
Retrieval studies have shown that the use of fully congruent meniscal bearings reduces wear in knee replacements. We report the outcome of 143 knees with anteromedial osteoarthritis and normal anterior cruciate ligaments treated by unicompartmental arthroplasty using fully congruous mobile polyethylene bearings. At review, 34 knees were in patients who had died and 109 were in those who were still living. The mean elapsed time since operation was 7.6 years (maximum 13.8). We established the status of all but one knee. There had been five revision operations giving a cumulative prosthetic survival rate at ten years (33 knees at risk) of 98% (95% CI 93% to 100%). Considering the knee lost to follow-up as a failure, the ‘worst-case’ survival rate was 97%. No failures were due to polyethylene wear or aseptic loosening of the tibial component. One bearing which dislocated at four years was reduced by closed manipulation. The
We reviewed the records of the long-term outcome of 208 Charnley and 982 Stanmore total hip replacements (THR) performed by or under the supervision of one surgeon from 1973 to 1987. The Stanmore implant had a better survival rate before revision at 14 years (86% to 79%, p = 0.004), but the difference only became apparent at ten years. The later Stanmore implants did better than the early ones (97% to 92% at ten years, p = 0.005), the improvement coinciding with the introduction of a new cementing technique using a gun. Most of the Charnley implants were done before most of the Stanmore implants so that the difference between the results may in part be explained by improved methods, but this is not the complete explanation since a difference persisted for implants carried out during the same period of time. We conclude that improved techniques have reduced failure rates substantially. This improvement was much greater than that observed between these two designs of implant. Proof of the difference would require a very large randomised controlled trial over a
Early failures have seen titanium fall from favour as a material for cemented femoral stems. Between 1989 and 1994, we performed a prospective review of a consecutive series of 122 cemented total hip replacements using the Ultima straight textured titanium stem, and report the five- to
This systematic review asked which patterns of complications are associated with the three reverse total shoulder arthroplasty (RTSA) prosthetic designs, as classified by Routman et al, in patients undergoing RTSA for the management of cuff tear arthropathy, massive cuff tear, osteoarthritis, and rheumatoid arthritis. The three implant design philosophies investigated were medial glenoid/medial humerus (MGMH), medial glenoid/lateral humerus (MGLH), and lateral glenoid/medial humerus (LGMH). A systematic review of the literature was performed via a search of MEDLINE and Embase. Two reviewers extracted data on complication occurrence and patient-reported outcome measures (PROMs). Meta-analysis was conducted on the reported proportion of complications, weighted by sample size, and PROMs were pooled using the reported standardized mean difference (SMD). Quality of methodology was assessed using Wylde’s non-summative four-point system. The study was registered with PROSPERO (CRD42020193041).Aims
Methods
1. Fifty cases of fibrosarcoma from the records of the Bristol Bone Tumour Registry are reviewed. They present further clinical and radiological evidence supporting the concept of fibrosarcoma as a distinctive type of bone tumour. 2. The radiographic appearances have often been those ofan osteolytic lesion totally enclosed by reactive subperiosteal new bone. 3. Included in the group are eleven cases with Paget's osteitis deformans, three cases in which the sarcoma was associated with calcified cartilage and one case that is regarded as a post-irradiation sarcoma. 4. Several clinically differing modes of presentation are described. 5. Fibrosarcoma in bone has often been said to be "central" or "medullary" but because the present series includes tumours with eccentric origin and unilateral cortical destruction this description is inappropriate. 6. The histological differentiation from other fibroblastic lesions is briefly discussed. 7. The five-year and
We report the
Chondrosarcoma is the second most common primary sarcoma of bone: conventional chondrosarcoma accounts for 85% of all cases. Conventional chondrosarcoma may be central or peripheral. Most studies group central and peripheral chondrosarcomas together, although there is growing evidence that their clinical behaviour and prognosis differ. The aims of this study were to analyze any differences in characteristics between central and peripheral chondrosarcomas and to investigate the incidence and role of different syndromes. Data from two international tertiary referral sarcoma centres between January 1995 and December 2018 were retrospectively reviewed. The study population consisted of 714 patients with surgically treated conventional chondrosarcoma of the pelvis and limbs.Aims
Methods
This is a retrospective case review of 237 patients with displaced fractures of the acetabulum presenting over a