Periprosthetic joint infection (PJI) is a devastating
complication which can follow a total joint arthroplasty (TJA).
Although rare, this ongoing threat undermines the success of TJA,
a historically reputable procedure. It has haunted the orthopedic
community for decades and several ongoing studies have provided
insights and new approaches to effectively battle this multilayered
problem.
The recent development of locking-plate technology has led to a potential revolution in the management of fractures of the distal radius. This review examines the evidence for pursuing anatomical restoration of the distal radius and the possible advantages and pitfalls of using volar locking plates to achieve this goal. The available evidence for adopting volar locking plates is presented and a number of important and, as yet unanswered, questions are highlighted.
We studied survival to 38 years after Charnley low-friction arthroplasty of the hip. We used revision as an end-point, while adopting a policy of regular follow-up and early revision for radiological changes alone if indicated. Between November 1962 and June 2005, 22 066 primary low-friction arthroplasties (17 409 patients) had been performed at Wrightington Hospital by more than 330 surgeons. By June 2006, 1001 (4.5%) hips had been revised and 1490 patients (2662 hips, 12%) had died. At 31 years, where a minimum of 40 hips were still attending follow-up, survival with revision for infection as an endpoint was 95%, for dislocation 98%, for a fractured stem 88.6%, for a loose stem 72.5% and for a loose acetabular component 53.7%. Wear and loosening of the ultra-high-molecular-weight polyethylene acetabular component were the main long-term problems. We conclude that regular follow-up after hip replacement is essential and that all operative findings should be recorded at revision.
Secure fixation of displaced proximal fractures of the humerus is a challenging problem. A total of 32 patients with acutely displaced three- or four-part proximal fractures of the humerus were treated by open reduction and internal fixation using the proximal humeral internal locking system (PHILOS) plate. There were 23 women and nine men with a mean age of 59.9 years (18 to 87). Data were collected prospectively and the outcomes were assessed using the Constant score. The mean follow-up was for 11 months (3 to 24). In 31 patients (97%) the fracture united clinically and radiologically at a mean of 10 weeks (8 to 24). The mean Constant score at final review was 66.5 (30 to 92). There was no significant difference in outcome when comparing patients aged more than 60 years (18 patients) with those aged less than 60 years (14 patients) ( This plate provides an alternative method of fixation for fractures of the proximal humerus. It provides a stable fixation in young patients with good-quality bone sufficient to permit early mobilisation. Failure of the screws to maintain fixation in the elderly remains a problem.
We report the management of an adult patient with septic sacroiliitis. This is an uncommon condition. Debridement, decompression and spontaneous fusion are the treatment of choice when symptoms do not resolve with routine initial intravenous antibiotic therapy. A percutaneous technique is described, using the principles of sacroiliac screw insertion commonly used for pelvic reconstruction surgery. After successful evacuation of the infected joint, fusion was observed in our patient.
The June 2012 Trauma Roundup360 looks at: nerve injuries of warfare; the medical complications of earthquakes; the measuring of tissue pressures in compartment syndrome; the risk of plunging through the bone when drilling; bony nonunion and negative pressure therapy; surgery for the posteriorly dislocated hip; whether to use the sliding screw or intramedullary nail for the trochanteric fracture; antegrade interlocking nailing for the distal femoral fracture; and gunshot wounds to the pancreas.
We report a case of sciatic nerve palsy following total hip replacement which has lead to a novel hypothesis to account for this complication.
In the majority of patients with slipped upper
femoral epiphysis only one hip is involved at primary diagnosis. However,
the contralateral hip often becomes involved over time. There are
no reliable factors predicting a contralateral slip. Whether or
not the contralateral hip should undergo prophylactic fixation is
a matter of controversy. We present a number of essential points
that have to be considered both when choosing to fix the contralateral
hip prophylactically as well as when refraining from surgery and
instead following the patients with repeat radiographs.
The use of autograft bone is the best option
when undertaking a procedure that requires bone graft because it
is osteogenic, osteoconductive and osseo-inductive. Pain, morbidity
and complications associated with harvesting iliac or non-iliac
sites occur in between 6% and 30% of cases. An alternative source
of graft with possibly a lower morbidity is the intramedullary canal.
In this study, 28 patients undergoing 30 arthrodesis procedures
on the hindfoot had a mean of 48 cm3 (43 to 50) of bone
harvested locally from the hindfoot or the tibial shaft by antegrade or
retrograde reaming. No patient sustained a fracture of the calcaneum,
talus or tibia. There was no morbidity except for one complication
when the reamer breached the medial tibial cortex. This healed uneventfully. This method of using the reamer–irrigator–aspirator system is
an extension of the standard technique of intramedullary reaming
of the lower limb: it produces good-quality bone graft with viable
growth factors consistent with that of the iliac crest, and donor
site morbidity is low. This is an efficient method of obtaining
autologous bone for use in arthrodesis of the ankle or hindfoot.
We report a variant of tibial hemimelia in a six-year-old boy that did not comply with recognised classification systems. The femur and knee were normal, but the fibula was displaced proximally and there was severe diastasis of the proximal and distal tibiofibular joints to the extent that a grossly deformed foot articulated with the fibula and there was separate soft-tissue cover for the distal tibia and fibula. Although it would have been preferable to create a one-bone leg, amputate the foot and use the fibula as the stump for a below-knee prosthesis, local circumstances resulted in the choice of a disarticulation through the knee. This was undertaken without complications, and six months post-operatively the child was walking comfortably with a prosthesis.
A 34-year-old woman with a benign form of osteopetrosis developed osteoarthritis of the hip. In order to avoid the difficulties associated with inserting the femoral component of a conventional total hip arthroplasty, a hybrid metal-on-metal resurfacing was performed. There were several technical challenges associated with the procedure, including the sizing of the component, press-fit fixation of the acetabular component and femoral head preparation, as well as trying to avoid a fracture. No surgical complication occurred. After more than a year following surgery, the patient showed excellent clinical function and remained satisfied with the outcome. We conclude that the hybrid metal-on-metal resurfacing arthroplasty represents a valuable option for the treatment of patients with osteopetrosis and secondary hip osteoarthritis.
We reviewed 59 bone graft substitutes marketed
by 17 companies currently available for implantation in the United Kingdom,
with the aim of assessing the peer-reviewed literature to facilitate
informed decision-making regarding their use in clinical practice.
After critical analysis of the literature, only 22 products (37%)
had any clinical data. Norian SRS (Synthes), Vitoss (Orthovita),
Cortoss (Orthovita) and Alpha-BSM (Etex) had Level I evidence. We question
the need for so many different products, especially with limited
published clinical evidence for their efficacy, and conclude that
there is a considerable need for further prospective randomised
trials to facilitate informed decision-making with regard to the
use of current and future bone graft substitutes in clinical practice. Cite this article:
The anatomical studies, basic to our understanding of lumbar spine innervation through the sinu-vertebral nerves, are reviewed. Research in the 1980s suggested that pain sensation was conducted in part via the sympathetic system. These sensory pathways have now been clarified using sophisticated experimental and histochemical techniques confirming a dual pattern. One route enters the adjacent dorsal root segmentally, whereas the other supply is non-segmental ascending through the paravertebral sympathetic chain with re-entry through the thoracolumbar white rami communicantes. Sensory nerve endings in the degenerative lumbar disc penetrate deep into the disrupted nucleus pulposus, insensitive in the normal lumbar spine. Complex as well as free nerve endings would appear to contribute to pain transmission. The nature and mechanism of discogenic pain is still speculative but there is growing evidence to support a ‘visceral pain’ hypothesis, unique in the muscloskeletal system. This mechanism is open to ‘peripheral sensitisation’ and possibly ‘central sensitisation’ as a potential cause of chronic back pain.
Alumina–alumina bearings are among the most resistant
to wear in total hip replacement. Examination of their surfaces
is one way of comparing damage caused by wear of hip joints simulated We found that long-term alumina wear in association with a loose
acetabular component could be categorised into three groups. Of
20 specimens, four had ‘low wear’, eight ‘crescent wear’ and eight
‘severe wear’, which was characterised by a change in the physical
shape of the bearing and a loss of volume. This suggests that the
wear in alumina–alumina bearings in association with a loose acetabular
component may be variable in pattern, and may explain, in part,
why the wear of a ceramic head
We analysed the outcome of patients with primary
non-metastatic diaphyseal sarcomas who had Extracorporeal irradiation is an oncologically safe and inexpensive
technique for limb salvage in diaphyseal sarcomas and has good functional
results.
Percutaneous epiphysiodesis using transphyseal
screws (PETS) has been developed for the treatment of lower limb discrepancies
with the aim of replacing traditional open procedures. The goal
of this study was to evaluate its efficacy and safety at skeletal
maturity. A total of 45 consecutive patients with a mean skeletal
age of 12.7 years (8.5 to 15) were included and followed until maturity.
The mean efficacy of the femoral epiphysiodesis was 35% (14% to 87%)
at six months and 66% (21% to 100%) at maturity. The mean efficacy
of the tibial epiphysiodesis was 46% (18% to 73%) at six months
and 66% (25% to 100%) at maturity. In both groups of patients the
under-correction was significantly reduced between six months post-operatively
and skeletal maturity. The overall rate of revision was 18% (eight
patients), and seven of these revisions (87.5%) involved the tibia.
This series showed that use of the PETS technique in the femur was
safe, but that its use in the tibia was associated with a significant
rate of complications, including a valgus deformity in nine patients
(20%), leading us to abandon it in the tibia. The arrest of growth
was delayed and the final loss of growth at maturity was only 66%
of that predicted pre-operatively. This should be taken into account
in the pre-operative planning.
In a randomised trial involving 598 patients
with 600 trochanteric fractures of the hip, the fractures were treated with
either a sliding hip screw (n = 300) or a Targon PF intramedullary
nail (n = 300). The mean age of the patients was 82 years (26 to
104). All surviving patients were reviewed at one year with functional
outcome assessed by a research nurse blinded to the treatment used.
The intramedullary nail was found to have a slightly increased mean
operative time (46 minutes ( In summary, both implants produced comparable results but there
was a tendency to better return of mobility for those treated with
the intramedullary nail.
Ciprofloxacin hydrochloride-loaded microspheres were prepared by a spray-drying method using pectin and chitosan. The effects of different polymers and drug ratios were investigated. The most appropriate carriers were selected by The drug was released rapidly from the pectin carrier but this was more sustained in the chitosan formulation. Chitosan microspheres loaded with ciprofloxacin hydrochloride were more effective for the treatment of osteomyelitis than equivalent intramuscular antibiotics.
We present the medium-term results of hybrid total hip arthroplasties using pre-coated stems with a second-generation cementing technique. The 128 hips in 111 patients (18 men and 93 women) were followed up at a mean of 11 years after surgery. The mean age at the time of surgery was 61 years. Both components of one hip were removed at ten months after surgery for infection. None of the other 127 femoral components showed possible, probable, or definite loosening at the most recent follow-up. Five acetabular components were revised for aseptic loosening, recurrent dislocation, or displacement of the polyethylene liner from the metal shell. The mean Harris hip score at follow-up was 84 points. A pre-coated femoral component with a second-generation cementing technique provides good clinical function and survival in the medium term.
Vertebral compression fractures are the most prevalent complication of osteoporosis and percutaneous vertebroplasty (PVP) has emerged as a promising addition to the methods of treating the debilitating pain they may cause. Since PVP was first reported in the literature in 1987, more than 600 clinical papers have been published on the subject. Most report excellent improvements in pain relief and quality of life. However, these papers have been based mostly on uncontrolled cohort studies with a wide variety of inclusion and exclusion criteria. In 2009, two high-profile randomised controlled trials were published in the