Despite a lack of long-term follow-up, there
is an increasing trend towards using femoral heads of large diameter
in total hip replacement (THR), partly because of the perceived
advantage of lower rates of dislocation. However, increasing the
size of the femoral head is not the only way to reduce the rate
of dislocation; optimal alignment of the components and repair of
the posterior capsule could achieve a similar effect. In this prospective study of 512 cemented unilateral THRs (Male:Female
230:282) performed between 2004 and 2011, we aimed to determine
the rate of dislocation in patients who received a 22 mm head on
a 9/10 Morse taper through a posterior approach with capsular repair
and using the transverse acetabular ligament (TAL) as a guide for the
alignment of the acetabular component. The mean age of the patients
at operation was 67 years (35 to 89). The mean follow-up was 2.8
years (0.5 to 6.6). Pre- and post-operative assessment included
Oxford hip, Short Form-12 and modified University of California
Los Angeles and Merle D’Aubigne scores. The angles of inclination
and anteversion of the acetabular components were measured using
radiological software. There were four dislocations (0.78%), all
of which were anterior. In conclusion, THR with a 22 mm diameter head performed through
a posterior approach with capsular repair and using the TAL as a
guide for the alignment of the acetabular component was associated
with a low rate of dislocation. Cite this article:
The aim of this study was to compare the post-operative radiographic
and clinical outcomes between kinematically and mechanically aligned
total knee arthroplasties (TKAs). A total of 60 TKAs (30 kinematically and 30 mechanically aligned)
were performed in 60 patients with varus osteoarthritis of the knee
using a navigation system. The angles of orientation of the joint
line in relation to the floor, the conventional and true mechanical
axis (tMA) (the line from the centre of the hip to the lowest point
of the calcaneus) were compared, one year post-operatively, on single-leg
and double-leg standing long leg radiographs between the groups.
The range of movement and 2011 Knee Society Scores were also compared
between the groups at that time.Aims
Patients and Methods
The objective of this study was to assess the association between whole body sagittal balance and risk of falls in elderly patients who have sought treatment for back pain. Balanced spinal sagittal alignment is known to be important for the prevention of falls. However, spinal sagittal imbalance can be markedly compensated by the lower extremities, and whole body sagittal balance including the lower extremities should be assessed to evaluate actual imbalances related to falls. Patients over 70 years old who visited an outpatient clinic for back pain treatment and underwent a standing whole-body radiograph were enrolled. Falls were prospectively assessed for 12 months using a monthly fall diary, and patients were divided into fallers and non-fallers according to the history of falls. Radiological parameters from whole-body radiographs and clinical data were compared between the two groups.Objectives
Methods
The April 2015 Research Roundup360 looks at: MCID in grip strength and distal radial fracture; Experiencing rehab in a trial setting; Electrical stimulation and nerve recovery; Molecular diagnosis of TB?; Acetabular orientation: component and arthritis; Analgesia after knee arthroplasty; Bisphosphonate-associated femoral fractures
This study aimed to determine the diagnostic performance of radiographic
criteria to detect aseptic acetabular loosening after revision total
hip arthroplasty (THA). Secondary aims were to determine the predictive
values of different thresholds of migration and to determine the
predictive values of radiolucency criteria. Acetabular component migration to re-revision was measured retrospectively
using Ein-Bild-Rontgen-Analyse (EBRA-Cup) and manual measurements
(Sutherland method) in two groups: Group A, 52 components (48 patients) found
not loose at re-revision and Group B, 42 components (36 patients)
found loose at re-revision between 1980 and 2015. The presence and
extent of radiolucent lines was also assessed.Aims
Patients and Methods
The purpose of this study was to determine patient-reported
outcomes of patients with mild to moderate developmental dysplasia
of the hip (DDH) and femoroacetabular impingement (FAI) undergoing
arthroscopy of the hip in the treatment of chondrolabral pathology.
A total of 28 patients with a centre-edge angle between 15° and
19° were identified from an institutional database. Their mean age
was 34 years (18 to 53), with 12 female and 16 male patients. All
underwent labral treatment and concomitant correction of FAI. There
were nine reoperations, with two patients requiring revision arthroscopy,
two requiring periacetabular osteotomy and five needing total hip arthroplasty. Patients who required further major surgery were more likely
to be older, male, and to have more severe DDH with a larger alpha
angle and decreased joint space. At a mean follow-up of 42 months (24 to 89), the mean modified
Harris hip score improved from 59 (20 to 98) to 82 (45 to 100; p
<
0.001). The mean Western Ontario and McMaster Universities
Osteoarthritis Index score improved from 30 (1 to 61) to 16 (0 to
43; p <
0.001). Median patient satisfaction was 9.0/10 (1 to
10). Patients reported excellent improvement in function following
arthroscopy of the hip. This study shows that with proper patient selection, arthroscopy
of the hip can be successful in the young patient with mild to moderate
DDH and FAI. Cite this article:
To determine the effect of a change in design of a cementless
ceramic acetabular component in fixation and clinical outcome after
total hip arthroplasty We compared 342 hips (302 patients) operated between 1999 and
2005 with a relatively smooth hydroxyapatite coated acetabular component
(group 1), and 337 hips (310 patients) operated between 2006 and
2011 using a similar acetabular component with a macrotexture on
the entire outer surface of the component (group 2). The mean age of
the patients was 53.5 (14 to 70) in group 1 and 53.0 (15 to 70)
in group 2. The mean follow-up was 12.7 years (10 to 17) for group
1 and 7.2 years (4 to 10) for group 2.Aims
Patients and Methods
This article is a systematic review of the published
literature about the biomechanics, functional outcome and complications
of intramedullary nailing of fractures of the distal radius. We searched the Medline and EMBASE databases and included all
studies which reported the outcome of intramedullary (IM) nailing
of fractures of the distal radius. Data about functional outcome,
range of movement (ROM), strength and complications, were extracted.
The studies included were appraised independently by both authors
using a validated quality assessment scale for non-controlled studies
and the CONSORT statement for randomised controlled trials (RCTs). The search strategy revealed 785 studies, of which 16 were included
for full paper review. These included three biomechanical studies,
eight case series and five randomised controlled trials (RCTs). The biomechanical studies concluded that IM nails were at least
as strong as locking plates. The clinical studies reported that
IM nailing gave a comparable ROM, functional outcome and grip strength
to other fixation techniques. However, the mean complication rate of intramedullary nailing
was 17.6% (0% to 50%). This is higher than the rates reported in
contemporary studies for volar plating. It raises concerns about
the role of intramedullary nailing, particularly when comparative
studies have failed to show that it has any major advantage over
other techniques. Further adequately powered RCTs comparing the
technique to both volar plating and percutaneous wire fixation are needed. Cite this article:
Hip resurfacing has been proposed as an alternative
to traditional total hip arthroplasty in young, active patients.
Much has been learned following the introduction of metal-on-metal resurfacing
devices in the 1990s. The triad of a well-designed device, implanted
accurately, in the correct patient has never been more critical
than with these implants. Following Food and Drug Administration approval in 2006, we studied
the safety and effectiveness of one hip resurfacing device (Birmingham
Hip Resurfacing) at our hospital in a large, single-surgeon series.
We report our early to mid–term results in 1333 cases followed for
a mean of 4.3 years (2 to 5.7) using a prospective, observational
registry. The mean patient age was 53.1 years (12 to 84); 70% were
male and 91% had osteoarthritis. Complications were few, including
no dislocations, no femoral component loosening, two femoral neck
fractures (0.15%), one socket loosening (0.08%), three deep infections
(0.23%), and three cases of metallosis (0.23%). There were no destructive
pseudotumours. Overall survivorship at up to 5.7 years was 99.2%. Aseptic survivorship
in males under the age of 50 was 100%. We believe this is the largest
United States series of a single surgeon using a single resurfacing
system. Cite this article:
Squeaking arising from a ceramic-on-ceramic (CoC)
total hip replacement (THR) may cause patient concern and in some
cases causes patients to seek revision surgery. We performed a meta-analysis
to determine the incidence of squeaking and the incidence of revision
surgery for squeaking. A total of 43 studies including 16 828 CoC
THR that reported squeaking, or revision for squeaking, were entered
into the analysis. The incidence of squeaking was 4.2% and the incidence
of revision for squeaking was 0.2%. The incidence of squeaking in
patients receiving the Accolade femoral stem was 8.3%, and the incidence
of revision for squeaking in these patients was 1.3%. Cite this article:
We conducted a study to determine whether radiological parameters
correlate with patient reported functional outcome, health-related
quality of life and physical measures of function in patients with
a fracture of the distal radius. The post-operative palmar tilt and ulnar variance at six weeks
and 12 months were correlated with the Patient Rated Wrist Evaluation,
Disabilities of the Arm, Shoulder and Hand, and EuroQol scores,
grip strength, pinch strength and range of movement at three, six
and 12 months for 50 patients (mean age 57 years; 26 to 85) having surgical
fixation, with either percutaneous pinning or reconstruction with
a volar plate, for a fracture of the distal radius.Aims
Patients and Methods
The three-dimensional (3D) correction of glenoid
erosion is critical to the long-term success of total shoulder replacement
(TSR). In order to characterise the 3D morphology of eroded glenoid
surfaces, we looked for a set of morphological parameters useful
for TSR planning. We defined a scapular coordinates system based
on non-eroded bony landmarks. The maximum glenoid version was measured
and specified in 3D by its orientation angle. Medialisation was
considered relative to the spino-glenoid notch. We analysed regular
CT scans of 19 normal (N) and 86 osteoarthritic (OA) scapulae. When
the maximum version of OA shoulders was higher than 10°, the orientation
was not only posterior, but extended in postero-superior (35%),
postero-inferior (6%) and anterior sectors (4%). The medialisation
of the glenoid was higher in OA than normal shoulders. The orientation
angle of maximum version appeared as a critical parameter to specify
the glenoid shape in 3D. It will be very useful in planning the
best position for the glenoid in TSR. Cite this article:
Osteosynthesis of anterior pubic ramus fractures using one large-diameter screw can be challenging in terms of both surgical procedure and fixation stability. Small-fragment screws have the advantage of following the pelvic cortex and being more flexible. The aim of the present study was to biomechanically compare retrograde intramedullary fixation of the superior pubic ramus using either one large- or two small-diameter screws. A total of 12 human cadaveric hemipelvises were analysed in a matched pair study design. Bone mineral density of the specimens was 68 mgHA/cm3 (standard deviation (Objectives
Materials and Methods
Cemented femoral stems with force closed fixation
designs have shown good clinical results despite high early subsidence.
A new triple-tapered stem in this category (C-stem AMT) was introduced
in 2005. This study compares this new stem with an established stem
of similar design (Exeter) in terms of migration (as measured using radiostereometric
analysis), peri-prosthetic bone remodelling (measured using dual
energy x-ray densitometry, DXA), Oxford Hip Score, and plain radiographs. A total of 70 patients (70 hips) with a mean age of 66 years
(53 to 78) were followed for two years. Owing to missing data of
miscellaneous reasons, the final analysis represents data from 51
(RSA) and 65 (DXA) patients. Both stems showed a typical pattern
of migration: Subsidence and retroversion that primarily occurred
during the first three months. C-stem AMT subsided less during the
first three months (p = 0.01), before stabilising at a subsidence rate
similar to the Exeter stem from years one to two. The rate of migration
into retroversion was slightly higher for C-stem AMT during the
second year (p = 0.03). Whilst there were slight differences in
movement patterns between the stems, the C-stem AMT exhibits good
early clinical outcomes and displays a pattern of migration and
bone remodelling that predicts good clinical performance. Cite this article:
We describe our technique and rationale using
hybrid fixation for primary total hip arthroplasty (THA) at the Hospital
for Special Surgery. Modern uncemented acetabular components have
few screw holes, or no holes, polished inner surfaces, improved
locking mechanisms, and maximised thickness and shell-liner conformity. Uncemented
sockets can be combined with highly cross-linked polyethylene liners,
which have demonstrated very low wear and osteolysis rates after
ten to 15 years of implantation. The results of cement fixation
with a smooth or polished surface finished stem have been excellent,
virtually eliminating complications seen with cementless fixation
like peri-operative femoral fractures and thigh pain. Although mid-term
results of modern cementless stems are encouraging, the long-term
data do not show reduced revision rates for cementless stems compared
with cemented smooth stems. In this paper we review the conduct
of a hybrid THA, with emphasis on pre-operative planning, surgical
technique, hypotensive epidural anaesthesia, and intra-operative
physiology. Cite this article:
We investigated the incidence of soft-tissue
lesions after small head metal-on-metal total hip replacement (MoM THR).
Between December 1993 and May 1999, 149 patients (195 hips) underwent
primary cementless MoM THR. During the follow-up period, three patients (five THRs) died
and eight patients (14 THRs) were lost to follow-up. We requested
that all patients undergo CT evaluation. After exclusion of five
patients (six THRs) who had undergone a revision procedure, and
22 (28 THRs) who were unwilling to take part in this study, 111
patients (142 THRs) were evaluated. There were 63 men (88 THRs)
and 48 women (54 THRs) with a mean age of 45.7 years (37 to 56)
at the time of surgery. The mean follow-up was 15.4 years (13 to
19). A soft-tissue lesion was defined as an abnormal peri-prosthetic
collection of fluid, solid lesion or asymmetrical soft-tissue mass. At final follow-up, soft-tissue lesions were found in relation
to 28 THRs (19.7%), including 25 solid and three cystic lesions.
They were found in 20 men and eight women; 26 lesions were asymptomatic
and two were symptomatic. The mean maximal diameter of the soft-tissue
lesion was 42.3 mm (17 to 135). The relatively high rate of soft-tissue lesions
observed with small head MoM THR remains a concern. Cite this article:
The aim of this study was to investigate the
relationship between the geometry of the proximal femur and the incidence
of intra-operative fracture during uncemented total hip arthroplasty
(THA). We studied the pre-operative CT scans of 100 patients undergoing
THA with an uncemented femoral component. We measured the anteroposterior
and mediolateral dimensions at the level of division of the femoral
neck to calculate the aspect ratio of the femur. Wide variations
in the shape of the femur were observed, from round, to very narrow
elliptic. The femurs of women were narrower than those of men (p
<
0.0001) and small femurs were also narrower than large ones.
Patients with an intra-operative fracture of the calcar had smaller
and narrower femurs than those without a fracture (p <
0.05)
and the implanted Corail stems were smaller in those with a fracture
(mean size 9 The variability of the shape of the femoral neck at the level
of division contributes to the understanding of the causation of
intra-operative fractures in uncemented THA. Cite this article:
We report the kinematic and early clinical results
of a patient- and observer-blinded randomised controlled trial in which
CT scans were used to compare potential impingement-free range of
movement (ROM) and acetabular component cover between patients treated
with either the navigated ‘femur-first’ total hip arthroplasty (THA) method
(n = 66; male/female 29/37, mean age 62.5 years; 50 to 74) or conventional
THA (n = 69; male/female 35/34, mean age 62.9 years; 50 to 75).
The Hip Osteoarthritis Outcome Score, the Harris hip score, the
Euro-Qol-5D and the Mancuso THA patient expectations score were
assessed at six weeks, six months and one year after surgery. A
total of 48 of the patients (84%) in the navigated ‘femur-first’
group and 43 (65%) in the conventional group reached all the desirable
potential ROM boundaries without prosthetic impingement for activities
of daily living (ADL) in flexion, extension, abduction, adduction
and rotation (p = 0.016). Acetabular component cover and surface
contact with the host bone were >
87% in both groups. There was
a significant difference between the navigated and the conventional
groups’ Harris hip scores six weeks after surgery (p = 0.010). There
were no significant differences with respect to any clinical outcome
at six months and one year of follow-up. The navigated ‘femur-first’
technique improves the potential ROM for ADL without prosthetic
impingement, although there was no observed clinical difference
between the two treatment groups. Cite this article:
Most published randomised controlled trials which
compare the rates of wear of conventional and cross-linked (XL) polyethylene
(PE) in total hip arthroplasty (THA) have described their use with
a cementless acetabular component. We conducted a prospective randomised study to assess the rates
of penetration of two distinct types of PE in otherwise identical
cemented all-PE acetabular components. A total of 100 consecutive patients for THA were randomised to
receive an acetabular component which had been either highly XL
then remelted or moderately XL then annealed. After a minimum of eight years follow-up, 38 hips in the XL group
and 30 hips in the annealed group had complete data (mean follow-up
of 9.1 years (7.6 to 10.7) and 8.7 years (7.2 to 10.2), respectively).
In the XL group, the steady state rate of penetration from one year
onwards was -0.0002 mm/year ( These results show that the yearly linear rate of femoral head
penetration can be significantly reduced by using a highly XLPE
cemented acetabular component. Cite this article: