Advertisement for orthosearch.org.uk
Results 341 - 360 of 904
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 1 | Pages 49 - 52
1 Jan 1990
Jensen D Rude C Duus B Bjerg-Nielsen A

We evaluated the long-term results of 109 tibial plateau fractures, 61 treated by skeletal traction and early knee movement and 48 treated by surgery, at an average follow-up of 70 months. The functional results were much the same, though meniscectomy had been performed in almost half of the surgical patients. Time in bed and duration of hospital stay were clearly shorter after surgery (p less than 0.0001). We concluded that conservative management is a valid alternative to surgery, but should probably be reserved for cases where operation is undesirable. Future studies should compare surgery without meniscectomy and conservative treatment using cast braces to reduce the time in traction


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 3 | Pages 383 - 386
1 Aug 1978
Soltanpur A

The management of an anterior supracondylar fracture by closed reduction, traction, percutaneous pinning or open reduction is seldom satisfactory, especially for adults and the aged with a lesser ability to remodel and a slower functional recovery. A new, safe, and simple technique is described in which the condylar mass is pushed posteriorly along the axis of the forearm and the hand is rotated to full supination while the elbow is held in flexion to correct deformities. Fixation is divided into two parts: the circular cast around the upper arm provides a firm buttress onto which the lower fragment is reduced and then the arm is immobilised in a plaster which includes the wrist. Four cases of delayed, comminuted, compound fractures have been fully evaluated clinically and radiologically and the results assessed as good or excellent


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 4 | Pages 620 - 623
1 Jul 1998
Mohammed NSE

A new technique of shoulder fusion is presented using a posterior approach. After removal of the articular cartilage, a Rush pin is introduced from the spine of the scapula, through the glenoid into the medullary canal of the humerus. This is supplemented by tension-band wiring from the acromion to the neck of the humerus and a muscle pedicle graft attached to the acromion. A shoulder spica is applied for four to six weeks. Four patients with injuries to the upper brachial plexus and 14 with paralysis of the upper arm due to anterior poliomyelitis have been followed for three years. One of the 18 patients developed nonunion; she had removed her own cast prematurely. This method of fixation provides high shear resistance and low axial stiffness without deforming plastically. It does not affect bone growth in young patients, is effective in patients with osteoporosis, and gives a high rate of union


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 5 | Pages 797 - 801
1 Sep 1995
Choi K Chan W Lam T Cheng J

Distal radial fractures are common in children. Recent outcome studies have cast doubt on the success of treatment by closed reduction and application of plaster. The most important risk factor for poor outcome is translation of the fracture. If a distal radial fracture is displaced by more than half the diameter of the bone at the fracture site it should be classified as high risk. We performed percutaneous Kirschner-wire pinning on 157 such high-risk distal radial fractures in children under 16 years of age. The predicted early and late failure rate was reduced from 60% to 14% and only 1.5% of patients had significant limitation of forearm movement of more than 15 degrees in the final assessment at a mean of 31 months after operation. There were no cases of early physeal closure or deep infection


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 4 | Pages 596 - 601
1 Jul 1994
Marks D Isbister E Porter K

We report 33 cases of femoral supracondylar fracture in elderly or debilitated patients treated by Zickel supracondylar nails. Most of the patients were female and their mean age was 79 years. All had concurrent medical problems and only nine could walk unaided. The operating time averaged one hour and mean blood loss was 100 ml. Postoperative management was by mobilisation in a cast brace or plaster. Six patients died before fracture union; all the others achieved union at an average of 12 weeks. The results were excellent in terms of pain relief, movement and function; there were no infections or nonunions. The locking screws backed out or broke in 26% but this did not prejudice the outcome. Use of the Zickel system is recommended for this group of frail patients


Bone & Joint 360
Vol. 8, Issue 5 | Pages 37 - 40
1 Oct 2019


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 1 | Pages 61 - 65
1 Jan 1993
Tiel-van Buul M van Beek E Broekhuizen A Bakker A Bos K van Royen E

Radiographs of the scaphoid after injury are difficult to interpret, and bone scintigraphy is widely used to increase the accuracy of diagnosis, though many fractures suspected on scintigraphy cannot be confirmed radiologically. We have reviewed the clinical consequences, after one year, of managing suspected scaphoid fractures according to the bone-scan results. We studied 160 patients, 35 of whom had initially positive radiographs and were treated in a cast for 12 weeks. The other 125 had bone scintigraphy and were managed according to the result. After a minimum of one year 119 patients were reviewed. Scintigraphically suspected scaphoid fracture could not be confirmed radiologically in 25%. There were no cases of nonunion. The long period of immobilisation in patients with positive radiographs or positive bone scans did not influence the frequency or severity of late symptoms compared with those with a normal bone scan


The Journal of Bone & Joint Surgery British Volume
Vol. 54-B, Issue 3 | Pages 432 - 441
1 Aug 1972
Maudsley RH Chen SC

1. A modification of the McLaughlin technique of lag screw fixation of the fractured scaphoid is described. 2. Fifty-six patients operated upon between 1956 and 1966 have been reviewed and their fractures classified under the headings recent, delayed union and non-union. 3. Plaster casts were avoided and early return to work encouraged; 95 per cent did so within two months. 4. Of twenty-two recent fractures, including three perilunar trans-scaphoid dislocations, nineteen united; of fifteen showing delayed union, eight united: and of nineteen cases of non-union, only two united. 5. The function of the wrist in the seventeen cases of persistent non-union stabilised by lag-screw was surprisingly good; only one patient has required arthrodesis to date. 6. The indications and contra-indications for the operation are discussed


Bone & Joint Open
Vol. 1, Issue 4 | Pages 74 - 79
24 Apr 2020
Baldock TE Bolam SM Gao R Zhu MF Rosenfeldt MPJ Young SW Munro JT Monk AP

Aim

The coronavirus disease 2019 (COVID-19) pandemic presents significant challenges to healthcare systems globally. Orthopaedic surgeons are at risk of contracting COVID-19 due to their close contact with patients in both outpatient and theatre environments. The aim of this review was to perform a literature review, including articles of other coronaviruses, to formulate guidelines for orthopaedic healthcare staff.

Methods

A search of Medline, EMBASE, the Cochrane Library, World Health Organization (WHO), and Centers for Disease Control and Prevention (CDC) databases was performed encompassing a variety of terms including ‘coronavirus’, ‘covid-19’, ‘orthopaedic’, ‘personal protective environment’ and ‘PPE’. Online database searches identified 354 articles. Articles were included if they studied any of the other coronaviruses or if the basic science could potentially applied to COVID-19 (i.e. use of an inactivated virus with a similar diameter to COVID-19). Two reviewers independently identified and screened articles based on the titles and abstracts. 274 were subsequently excluded, with 80 full-text articles retrieved and assessed for eligibility. Of these, 66 were excluded as they compared personal protection equipment to no personal protection equipment or referred to prevention measures in the context of bacterial infections.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 3 | Pages 484 - 487
1 May 1996
Gleeson AP Stuart MJ Wilson B Phillips B

We studied 45 children who presented with an inversion injury of the ankle. The clinical signs suggested injury to the distal growth plate of the fibula, but the plain radiographs appeared normal. Ultrasound examination of the joint in 40 patients showed a subperiosteal haematoma consistent with a growth-plate injury in 23 (57.5%). Children who had been treated with a tubular bandage and crutches by random selection had a mean time to return of normal activity of 14.22 days compared with 21.60 days for those treated with a plaster-of-Paris cast (t = 3.60, p = 0.0032; d = 7.38, 95% CI 3.0 to 11.8). We conclude that children with inversion ankle injuries who have clinical signs of injury to the distal fibular growth plate but a normal radiological appearance, should be treated with a tubular bandage and crutches


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 6 | Pages 856 - 863
1 Aug 2000
Sanchez-Sotelo J Munuera L Madero R

We performed a prospective, randomised study on 110 patients more than 50 years old with fractures of the distal radius to compare the outcome of conservative treatment with that using remodellable bone cement (Norian skeletal repair system, SRS) and immobilisation in a cast for two weeks. Patients treated with SRS had less pain and earlier restoration of movement and grip strength. The results at one year were satisfactory in 81.54% of the SRS patients and 55.55% of the control group. The rates of malunion were 18.2% and 41.8%, respectively. There was a significant relationship between the functional and radiological results. Soft-tissue extrusion was present initially in 69.1% of the SRS patients; most deposits disappeared progressively, but persisted in 32.73% at one year. We conclude that the injection of a remodellable bone cement into the trabecular defect of fractures of the distal radius provides a better clinical and radiological result than conventional treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 2 | Pages 192 - 199
1 Mar 2000
Engelbrecht E von Foerster G Delling G

Glass ionomer cement (Ionocem) was developed for use in bone surgery and is reported to be notably biocompatible. Between 1991 and 1994 we performed revision operations for aseptic loosening of arthroplasties of the hip on 45 patients using this material in its granulate form (Ionogran) mixed with homologous bone as a bone substitute. Of these 45 patients, 42 were followed up for a mean of 42 months. Early reloosening of the acetabular component has occurred in ten after a mean of 30 months. Histological examination showed large deposits of aluminium in the adjacent connective tissue and bone. Osteoblastic function and bone mineralisation were clearly inhibited. The serum levels of aluminium were also increased. The toxic damage at the bone interface caused by high local levels of aluminium must be seen as an important factor in the high rate of early reloosening. Our findings cast doubt on the biocompatibility of this material and we do not recommend continuation of its further use in orthopaedic surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 7 | Pages 1009 - 1014
1 Sep 2002
Deijkers RLM Bloem RM Hogendoorn PCW Verlaan JJ Kroon HM Taminiau AHM

Low-grade surface tumours of bone may theoretically be treated by hemicortical resection, retaining part of the circumference of the cortex. An inlay allograft may be used to reconstruct the defect. Since 1988 we have performed 22 hemicortical procedures in selected patients with low-grade parosteal osteosarcoma (6), peripheral chondrosarcoma (6) and adamantinoma (10). Restricted medullary involvement was not a contraindication for this procedure. There was no evidence of local recurrence or distant metastasis at a mean follow-up of 64 months (27 to 135). Wide resection margins were obtained in 19 patients. All allografts incorporated completely and there were no fractures or infections. Fractures of the remaining hemicortex occurred in six patients and were managed successfully by casts or by osteosynthesis. The functional results were excellent or good in all except one patient. Hemicortical procedures for selected cases of low-grade surface tumours give excellent oncological and functional outcomes. There was complete remodelling and fewer complications when compared with larger intercalary procedures. The surgery is technically demanding but gives good clinical results


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 4 | Pages 671 - 675
1 Jul 1991
Kenwright J Albinana J

We reviewed 46 leg-shortening operations (37 femoral and nine tibial), performed by different methods, to assess the incidence of complications and permanent disability. Shortening of as much as 7.5 cm in the femur and 5 cm in the tibia was achieved in men of normal height without any loss of function. Complications were seen with all surgical techniques despite the use of modern implants. Most problems arose from inadequate stabilisation of the osteotomy. The most reliable method of femoral shortening was open subtrochanteric osteotomy with preservation of the isthmus, and fixation with an intramedullary nail locked at its proximal end. In tibial shortening, bone excision should be at the level of the flare in the lower diaphysis in order to achieve reliable bone healing. Simple intramedullary nail fixation should be supplemented with a long-leg cast for six weeks or the nail should be locked at both ends to prevent postoperative distraction or rotation


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 47 - 52
1 Jan 1991
Zarnett R Velazquez R Salter R

Our purpose was to determine whether continuous passive motion enhanced the quality of knee ligament reconstruction using carbon fibre. In 46 rabbits the medial collateral ligaments were excised and replaced with carbon fibre prostheses. The animals were treated postoperatively by either continuous passive motion, cast immobilisation or cage activity, termed intermittent active motion. At six weeks, the ligaments were compared histologically and biomechanically with normal (control) medial collateral ligaments and with sham-operated controls. The ligaments treated with continuous passive motion were superior to those in the other two treatment groups. There were no ligament failures in any of the groups. This study suggests that continuous passive motion, initiated immediately postoperatively, enhances the biomechanical properties of carbon fibre ligament replacement of the medial collateral ligament while preventing the harmful effects of joint immobilisation


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 3 | Pages 418 - 422
1 May 1986
Roberts S Weightman B Urban J Chappell D

Articular cartilage from the femoral heads of 27 patients having an arthroplasty for subcapital fracture was studied, and its mechanical and chemical properties compared to those of a group of 33 age-matched macroscopically normal autopsy specimens. Water and proteoglycan contents were measured, as were swelling ability, compressive and tensile strength of the cartilage, and the density of the underlying bone. Cartilage from the fracture specimens had a significantly reduced proteoglycan content, as measured by fixed charge density, and increased swelling ability. These results indicate that this group differs from the "normal" population and care should be taken before they are accepted as control material for studies on osteoarthritic cartilage. Another finding was that bone density was much the same in the fracture and the normal group. This casts some doubt upon the concept that patients who sustain subcapital fractures are more osteoporotic than the average for the same age range


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 3 | Pages 413 - 417
1 Apr 2002
McLauchlan GJ Cowan B Annan IH Robb JE

In a prospective, randomised controlled trial, 68 children who had a completely displaced metaphyseal fracture of the distal radius were treated either by manipulation (MUA) and application of an above-elbow cast alone or by the additional insertion of a percutaneous Kirschner (K-) wire. Full radiological follow-up to union was obtained in 65 children and 56 returned for clinical evaluation three months after injury. Maintenance of reduction was significantly better in the K-wire group and fewer follow-up radiographs were required. There was no significant difference in the clinical outcome measured three months after injury. Seven of 33 patients in the MUA group had to undergo a second procedure because of an unacceptable position compared with none of the 35 in the K-wire group (chi-squared test, p < 0.01). One patient in the K-wire group required exploration for recovery of a migrated wire. We conclude that the use of a percutaneous K-wire to augment the reduction of the fracture in children who have a completely displaced metaphyseal fracture of the distal radius is a safe and reliable way of maintaining alignment of the fracture


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 392 - 397
1 May 1999
Tennant S Kinmont C Lamb G Gedroyc W Hunt DM

Conventional methods of imaging in the investigation of developmental dysplasia of the hip all have disadvantages, either in definition or in exposure to radiation. We describe a new open-configuration MR scanner which is unique in that it allows anaesthesia and access to the patient within the imaging volume for surgical procedures and application of casts. We performed 13 scans in eight anaesthetised infants. Dynamic imaging revealed two dislocated hips which were then visualised during reduction. Hip spicas were applied without removing the patient from the scanner. In one hip, an adductor tenotomy was carried out. In all patients, stressing the hips during dynamic imaging allowed an assessment of stability. This was particularly useful in two hips in which an analysis of stability in different positions facilitated the planning of femoral osteotomies. This method of imaging provides new and important information. It has great potential in the investigation of developmental dysplasia of the hip and, with ultrasound, may allow management without the need for radiography


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 1 | Pages 114 - 123
1 Jan 1984
Herbert T Fisher W

A new and simple operative technique has been developed to provide rigid internal fixation for all types of fractures of the scaphoid. This involves the use of a double-threaded bone screw which provides such good fixation that, after operation, a plaster cast is rarely required and most patients are able to return to work within a few weeks. A classification of scaphoid fractures is proposed. The indications for operation included not only acute unstable fractures, but also fractures with delayed healing and those with established non-union; screw fixation was combined with bone grafting to treat non-union. In a prospective trial, 158 operations using this technique were carried out between 1977 and 1981. The rate of union was 100 per cent for acute fractures and 83 per cent overall. This method of treatment appears to offer significant advantages over conventional techniques in the management of the fractured scaphoid


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 4 | Pages 510 - 515
1 Nov 1978
Fraser R Hunter G Waddell J

The hospital records of 222 cases of ipsilateral fractures of the femur and tibia were reviewed, and patients were grouped according to the type of fracture and the method of treatment. Thirty-five per cent of patients required late operation for delayed union or non-union, osteomyelitis, refracture and malunion, regardless of the treatment group. A disturbing factor was the 30% incidence of osteomyelitis in patients treated by fixation of both fractures, almost three times the incidence when only one fracture was fixed. A 30% incidence of delayed union or non-union occurred in patients managed conservatively. Of sixty-three patients personally examined, the worst results found were those following conservative management of both fractures. More use of rigid external fixation and of cast bracing is recommended in the management of the fractured tibia, combined with internal fixation of the femoral fracture. Examination of the knee suggested that, with ipsilateral fractures, disruption of ligaments is a common occurrence and should always be suspected