We retrospectively reviewed, ten years after surgery, 100 consecutive total hip replacements in which the Duraloc 300 cup had been used. Post-operative radiographs were analysed for placement of the cup and interface gaps and follow-up radiographs for lucent lines, osteolysis, wear and migration. All the components were found to be stable with no evidence of loosening. The mean rate of wear was 0.12 mm/year. Three hips developed acetabular osteolysis at the level of the apex hole. Two have successfully undergone
1. Cancellous
A dose of 48 Gy of X-irradiation given over two to five weeks after grafting caused no significant delay in the rate of healing and only a small and statistically non-significant decrease in the torsional strength of the graft-bone junction of either vascularised or non-vascularised
Giant-cell tumour of bone (GCT) is a locally benign aggressive tumour. The use of adjuvant agents, such as phenol or liquid nitrogen has been recommended to destroy the remaining tumour cells after curettage, and filling of the defect with methylmethacrylate cement has been advocated. Between 1957 and 1992 we treated 92 patients with a GCT with 50% aqueous zinc chloride solution and
We carried out a retrospective study to assess the clinical results of lengthening the fourth metatarsal in brachymetatarsia in 153 feet of 106 patients (100 female, six males) using three different surgical techniques. In one group lengthening was performed by one-stage intercalary
Between 1990 and 2000, 123 hips in 110 patients were reconstructed for aseptic loosening using impaction
We performed a prospective, randomised trial on 120 patients with redisplaced fractures of the distal radius comparing four methods of treatment. The four treatment groups, each containing 30 patients, were remanipulation and plaster, open reduction and
Sixteen patients who underwent a revision operation for nonunion of fractures of the distal humerus following previous internal fixation were reviewed at a mean follow-up of 39 months (8 to 69). The Mayo elbow performance score was excellent in 11, good in two, fair in two and poor in one. In 15 patients union was achieved and in one with an infected nonunion a subsequent
Six highly unstable elbows with severe bone loss due to rheumatoid arthritis were replaced by a non-constrained, unlinked prosthesis. Bone defects were filled with autogenous bone grafts. The mean follow-up was 4.5 years (2 to 8). The clinical results were excellent in four elbows and good in two, with good varus-valgus stability in all. Radiological follow-up showed no appreciable signs of loosening, and the
Ten patients with humeral shaft fractures and no clinical or radiographic signs of healing after at least six weeks' immobilisation were treated by flexible intramedullary nailing using a closed retrograde technique.
We identified 148 patients who had undergone a revision total knee replacement using a single implant system between 1990 and 2000. Of these 18 patients had died, six had developed a peri-prosthetic fracture and ten had incomplete records or radiographs. This left 114 with prospectively-collected radiographs and Bristol knee scores available for study. The height of the joint line before and after revision total knee replacement was measured and classified as either restored to within 5 mm of the pre-operative height or elevated if it was positioned more than 5 mm above the pre-operative height. The joint line was elevated in 41 knees (36%) and restored in 73 (64%). Revision surgery significantly improved the mean Bristol knee score from 41.1 (. sd. 15.9) pre-operatively to 80.5 (. sd. 15) post-operatively (p <
0.001). At one year post-operatively both the total Bristol knee score and its functional component were significantly better in the restored group than in the elevated group (p <
0.01). Overall, revision from a unicondylar knee replacement required less use of
We have reviewed 54 hips in 46 patients from 2 to 14 years after a joint-preserving operation for idiopathic avascular necrosis of the femoral head. The choice between core decompression (17 hips),
The beneficial effect upon osteogenesis of imprenating
The aim of this study was to report the medium-term outcomes of impaction bone allograft and fibular grafting for osteonecrosis of the femoral head (ONFH) and to define the optimal indications. A total of 67 patients (77 hips) with ONFH were enrolled in a single centre retrospective review. Success of the procedure was assessed using the Harris Hip Score (HHS) and rate of revision to total hip arthroplasty (THA). Risk factors were studied, including age, aetiology, duration of hip pain, as well as two classification systems (Association Research Circulation Osseous (ARCO) and Japanese Investigation Committee (JIC) systems).Aims
Methods
We present the results of ankle fusion using the Ilizarov technique for bone loss around the ankle in 20 patients. All except one had sustained post-traumatic bone loss. Infection was present in 17. The mean age was 33.1 years (7 to 71). The mean size of the defect was 3.98 cm (1.5 to 12) and associated limb shortening before the index procedure varied from 1 cm to 5 cm. The mean time in the external fixator was 335 days (42 to 870). Tibiotalar fusion was performed in 19 patients and tibiocalcaneal fusion in one. Associated problems included diabetes in one patient, pelvic and urethral injury in one, visual injury in one patient and ipsilateral tibial fracture in five. At the final mean follow-up of 51.55 months (24 to 121) fusion had been achieved in 19 of 20 patients. A total of 16 patients were able to return to work. The results were graded as good in 11 patients, fair in six and poor in three. The mean external fixation index was 8.8 days/mm (0 to 30). One patient with diabetes developed severe infection which required early removal of the fixator. Refractures occurred in three patients, two of which were at the site of fusion and one at a previous tibial shaft fracture site. Equinus deformity of the ankle fusion occurred after a further fracture in one patient. There were two patients with residual forefoot equinus, and one developed late valgus at the fusion site. Poor consolidation of the regenerated bone in two patients was treated by
One-stage femoral lengthening is thought to have an unacceptably high complication rate and is not widely practised. We reviewed 17 patients after one-stage lengthening for femoral shortening with associated angular or rotational deformities. Minimal dissection of the bone ends was undertaken. The mean length gain was 4 cm (2 to 7), and the average time to union was 6 months (3 to 10). There were no neurovascular complications. Four patients had delayed or nonunion, but union was achieved after
In acetabular dysplasia, fixation of the acetabular component of a cemented total hip prosthesis may be insecure and superolateral
Between 1976 and 2004, 38 revision arthroplasties (35 patients) were performed for aseptic loosening of the humeral component. The mean interval from primary arthroplasty to revision was 7.1 years (0.4 to 16.6). A total of 35 shoulders (32 patients) were available for review at a mean follow-up of seven years (2 to 19.3). Pre-operatively, 34 patients (97%) had moderate or severe pain; at final follow-up, 29 (83%) had no or only mild pain (p <
0.0001). The mean active abduction improved from 88° to 107° (p <
0.01); and the mean external rotation from 37° to 46° (p = 0.27). Excellent or satisfactory results were achieved in 25 patients (71%) according to the modified Neer rating system. Humeral components were cemented in 29, with ingrowth implants used in nine cases. There were 19 of standard length and 17 were longer (two were custom replacements and are not included).
Complex total hip arthroplasty (THA) with subtrochanteric shortening osteotomy is necessary in conditions other than developmental dysplasia of the hip (DDH) and septic arthritis sequelae with significant proximal femur migration. Our aim was to evaluate the hip centre restoration with THAs in these hips. In all, 27 THAs in 25 patients requiring THA with femoral shortening between 2012 and 2019 were assessed. Bilateral shortening was required in two patients. Subtrochanteric shortening was required in 14 out of 27 hips (51.9%) with aetiology other than DDH or septic arthritis. Vertical centre of rotation (VCOR), horizontal centre of rotation, offset, and functional outcome was calculated. The mean followup was 24.4 months (5 to 92 months).Aims
Methods
1. In the treatment of chronic osteomyelitis the most troublesome factor is the infected bone cavity. This is seldom obliterated spontaneously by bone regeneration. The number of procedures designed to fill the cavity, since the beginning of the century, show how much it troubles the surgeon. 2. The use of