We performed a modified, rotational acetabular osteotomy through a lateral transtrochanteric approach on 19 hips in 18 patients with a dysplastic joint. Six hips in six patients were operated on using the original approach. The mean age at operation was 28 years (14 to 54) and the mean period of follow-up 2.3 years (1 to 4.4). Clinical evaluation using the Merle d’Aubigné score showed excellent or good results in 76%. Radiologically, 15 hips showed good acetabular remodelling and no signs of progressive osteoarthritis. In ten hips (40%) there was chondrolysis and collapse of the transferred
Migration of the acetabular component may give rise to oval-shaped bone defects in the
The Chiari osteotomy and various shelf procedures are used to augment the weight-bearing area in dysplastic acetabula. The new articular surface derives by metaplasia from the acetabular rim and joint capsule, and is therefore of poorer quality than congruous hyaline cartilage. We reviewed 32 patients after augmentation procedures, using conventional radiographs and three-dimensional reconstruction from CT scans. We showed that Chiari osteotomy and shelf procedures generally achieve less than complete cover, especially over the posterolateral quadrant of the femoral head. Our results suggest that alternative methods which reorientate the whole of the
We performed Charnley total hip arthroplasties on 64 patients (71 hips) between 1976 and 1984 for moderate congenital acetabular dysplasia in which a superolateral cement thickness of less than 20 mm was expected when the cup was placed in the true
We carried out radial MRI in 30 hips with moderate osteoarthritis and in ten normal hips. On a scout view containing the entire acetabular rim, 12 vertical radial slices were set at 15° intervals. Different appearances were observed in different parts of the joint. In the weight-bearing portion, from 45° anterosuperior to 45° posterosuperior, ‘attenuation’ (n = 16) and ‘disappearance’ (n = 25) were observed as abnormalities of the labrum with ‘capsular stripping’ (n = 29) and ‘extraosseous high signal lesion’ (n = 27) as capsular abnormalities, seen more often in the anterosuperior portion. In all 12 planes there were osteophytes on the acetabular edge (n = 24), femoral head (n = 22) and/or at the central
We retrospectively reviewed 56 patients (71 hips) treated by total replacement for severe disability after pelvic irradiation. Symptoms were associated with various radiological lesions due to irradiation, including atraumatic femoral-neck fracture, osteonecrosis of the femoral head or of the
Hip resurfacing is a bone-conserving procedure with respect to proximal femoral resection, but there is debate in the literature as to whether the same holds true for the
Complex total hip arthroplasty (THA) with subtrochanteric shortening osteotomy is necessary in conditions other than developmental dysplasia of the hip (DDH) and septic arthritis sequelae with significant proximal femur migration. Our aim was to evaluate the hip centre restoration with THAs in these hips. In all, 27 THAs in 25 patients requiring THA with femoral shortening between 2012 and 2019 were assessed. Bilateral shortening was required in two patients. Subtrochanteric shortening was required in 14 out of 27 hips (51.9%) with aetiology other than DDH or septic arthritis. Vertical centre of rotation (VCOR), horizontal centre of rotation, offset, and functional outcome was calculated. The mean followup was 24.4 months (5 to 92 months).Aims
Methods
The purpose of this study was to compare the clinical, radiological, and patient-reported outcome measures (PROMs) in the first 100 consecutive patients undergoing total hip arthroplasty (THA) via a direct superior approach (DSA) with a matched group of patients undergoing THA by the same surgeon, using a posterolateral approach (PLA). This was a retrospective single surgeon study comparing the first 100 consecutive DSA THA patients with a matched group of patients using a standard PLA. Case notes were examined for patient demographics, length of hospital stay, operating time, intra- and postoperative complications, pain score, satisfaction score, and Oxford Hip Score (OHS). Leg length discrepancy and component positioning were measured from postoperative plain radiographs.Aims
Methods
The results are reported of 44 consecutive Chiari innominate osteotomies performed on 39 adult patients aged between 18 and 55 years for symptoms arising from disproportion between the
Stereoradiography with a base shift of the source of illumination was used to produce pairs of radiographs to be measured by stereophotogrammetric techniques. The direction of shift was parallel with the longitudinal axis of the body, so that each radiograph in the stereopair could be used for other clinical purposes. A base shift of 10 centimetres with a distance of 100 centimetres between the focus and the film gave acceptable value of stereoscopic parallax. The radiographs were measured using a Hilger and Watts medical stereometer. This method was checked with test specimens, namely an osteotomised pelvis in which one
Despite advances in the treatment of paediatric hip disease, adolescent and young adult patients can develop early onset end-stage osteoarthritis. The aims of this study were to address the indications and medium-term outcomes for total hip arthroplasty (THA) with ceramic bearings for teenage patients. Surgery was performed by a single surgeon working in the paediatric orthopaedic unit of a tertiary referral hospital. Databases were interrogated from 2003 to 2017 for all teenage patients undergoing THA with a minimum 2.3 year follow-up. Data capture included patient demographics, the underlying hip pathology, number of previous surgeries, and THA prostheses used. Institutional ethical approval was granted to contact patients for prospective clinical outcomes and obtain up-to-date radiographs. In total, 60 primary hips were implanted in 51 patients (35 female, 16 male) with nine bilateral cases. The mean age was 16.7 years (12 to 19) and mean follow-up was 9.3 years (2.3 to 16.8).Aims
Methods
Optimal exposure through the direct anterior approach (DAA) for total hip arthroplasty (THA) conducted on a regular operating theatre table is achieved with a standardized capsular releasing sequence in which the anterior capsule can be preserved or resected. We hypothesized that clinical outcomes and implant positioning would not be different in case a capsular sparing (CS) technique would be compared to capsular resection (CR). In this prospective trial, 219 hips in 190 patients were randomized to either the CS (n = 104) or CR (n = 115) cohort. In the CS cohort, a medial based anterior flap was created and sutured back in place at the end of the procedure. The anterior capsule was resected in the CR cohort. Primary outcome was defined as the difference in patient-reported outcome measures (PROMs) after one year. PROMs (Harris Hip Score (HHS), Hip disability and Osteoarthritis Outcome Score (HOOS), and Short Form 36 Item Health Survey (SF-36)) were collected preoperatively and one year postoperatively. Radiological parameters were analyzed to assess implant positioning and implant ingrowth. Adverse events were monitored.Aims
Methods
To investigate the effect of polyethylene manufacturing characteristics and irradiation dose on the survival of cemented and reverse hybrid total hip arthroplasties (THAs). In this registry study, data from the National Joint Registry of England, Wales, Northern Ireland and the Isle of Man (NJR) were linked with manufacturing data supplied by manufacturers. The primary endpoint was revision of any component. Cox proportional hazard regression was a primary analytic approach adjusting for competing risk of death, patient characteristics, head composition, and stem fixation.Aims
Methods
Cementless acetabular components rely on press-fit fixation for initial stability. In certain cases, initial stability is more difficult to obtain (such as during revision). No current study evaluates how a surgeon’s impaction technique (mallet mass, mallet velocity, and number of strikes) may affect component fixation. This study seeks to answer the following research questions: 1) how does impaction technique affect a) bone strain generation and deterioration (and hence implant stability) and b) seating in different density bones?; and 2) can an impaction technique be recommended to minimize risk of implant loosening while ensuring seating of the acetabular component? A custom drop tower was used to simulate surgical strikes seating acetabular components into synthetic bone. Strike velocity and drop mass were varied. Synthetic bone strain was measured using strain gauges and stability was assessed via push-out tests. Polar gap was measured using optical trackers.Aims
Methods
In 12 patients, we measured the oxygen concentration in the femoral head-neck junction during hip resurfacing through the anterolateral approach. This was compared with previous measurements made for the posterior approach. For the anterolateral approach, the oxygen concentration was found to be highly dependent upon the position of the leg, which was adjusted during surgery to provide exposure to the
1. A total of 120 Moore's arthroplasties in 111 patients were reviewed one to nine years after operation. 2. There was striking reduction in the severity of pain in 105 out of the 120 hips reviewed. Range of movement was improved in most patients but the degree of independence was improved less often. The reasons for this are discussed. 3. We draw the following conclusions regarding the place of Moore's arthroplasty. Firstly, it was a natural step in the evolution towards total hip replacement, an operation which promises to give more complete relief of symptoms and which seems likely to replace Moore's arthroplasty as the treatment of choice in osteoarthritis of the hip in the elderly. Secondly, Moore's arthroplasty is still a rational procedure for the treatment of degeneration if the
1. Three hundred and twenty cases of tuberculosis of the hip joint have been analysed and the late results assessed three or more years after discharge from hospital. 2. The primary bone focus involved the
There are no recent studies comparing cable with
wire for the fixation of osteotomies or fractures in total hip replacement
(THR). Our objective was to evaluate the five-year clinical and
radiological outcomes and complication rates of the two techniques.
We undertook a review including all primary and revision THRs performed
in one hospital between 1996 and 2005 using cable or wire fixation.
Clinical and radiological evaluation was performed five years post-operatively.
Cables were used in 51 THRs and wires in 126, and of these, 36 THRs
with cable (71%) and 101 with wire (80%) were evaluated at follow-up.
The five-year radiographs available for 33 cable and 91 wire THRs
revealed rates of breakage of fixation of 12 of 33 (36%) and 42
of 91 (46%), respectively. With cable there was a significantly
higher risk of metal debris (68% vs 9%; adjusted
relative risk (RR) 6.6; 95% confidence interval (CI) 3.0 to 14.1),
nonunion (36% vs 21%; adjusted RR 2.0; 95% CI 1.0
to 3.9) and osteolysis around the material,