header advert
Results 321 - 340 of 4011
Results per page:
Bone & Joint 360
Vol. 6, Issue 1 | Pages 13 - 16
1 Feb 2017


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1160 - 1169
1 Sep 2012
Bohm ER Tufescu TV Marsh JP

This review considers the surgical treatment of displaced fractures involving the knee in elderly, osteoporotic patients. The goals of treatment include pain control, early mobilisation, avoidance of complications and minimising the need for further surgery. Open reduction and internal fixation (ORIF) frequently results in loss of reduction, which can result in post-traumatic arthritis and the occasional conversion to total knee replacement (TKR). TKR after failed internal fixation is challenging, with modest functional outcomes and high complication rates. TKR undertaken as treatment of the initial fracture has better results to late TKR, but does not match the outcome of primary TKR without complications. Given the relatively infrequent need for late TKR following failed fixation, ORIF is the preferred management for most cases. Early TKR can be considered for those patients with pre-existing arthritis, bicondylar femoral fractures, those who would be unable to comply with weight-bearing restrictions, or where a single definitive procedure is required


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 675 - 681
1 Jun 2019
Gabor JA Padilla JA Feng JE Anoushiravani AA Slover J Schwarzkopf R

Aims

Revision total knee arthroplasty (rTKA) accounts for approximately 5% to 10% of all TKAs. Although the complexity of these procedures is well recognized, few investigators have evaluated the cost and value-added with the implementation of a dedicated revision arthroplasty service. The aim of the present study is to compare and contrast surgeon productivity in several differing models of activity.

Materials and Methods

All patients that underwent primary or revision TKA from January 2016 to June 2018 were included as the primary source of data. All rTKA patients were categorized by the number of components revised (e.g. liner exchange, two or more components). Three models were used to assess the potential surgical productivity of a dedicated rTKA service : 1) work relative value unit (RVU) versus mean surgical time; 2) primary TKA with a single operating theatre (OT) versus rTKA with a single OT; and 3) primary TKA with two OTs versus rTKA with a single OT.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 53 - 56
1 Jan 1991
Barrett D Cobb A Bentley G

We measured joint position sense in the knee by a new method which tests the proprioceptive contribution of the joint capsule and ligaments. The leg was supported on a splint, and held in several positions of flexion. The subjects' perception of the position was recorded on a visual analogue model and compared with the actual angle of flexion. Eighty-one normal and 45 osteoarthritic knees were examined, as were 10 knees with semi-constrained and 11 with hinged joint replacements. All were assessed with and without an elastic bandage around the knee. There was a steady decline in joint position sense with age in subjects with normal knees. Those with osteoarthritic knees had impaired joint position sense at all ages (p less than 0.001). Knee replacement improved the joint position sense slightly (p less than 0.02); semi-constrained replacement had a greater effect than hinged replacement. The effect of an elastic bandage in subjects with poor position sense was dramatic, improving accuracy by 40% (p less than 0.001). It is proposed that reduced proprioception in elderly and osteoarthritic subjects may be responsible for initiation or advancement of degeneration of the knee


The Journal of Bone & Joint Surgery British Volume
Vol. 59-B, Issue 4 | Pages 433 - 438
1 Nov 1977
Abraham E Verinder D Sharrard W

A follow-up study, on average four years after operation, of seventy-six cildren with myelomeningocele who had surgical treatment for flexion contracture of the knee, is reported. After a single operation sixty-eight knees (55 per cent) had a contracture of less than 20 degrees, which was the main criterion of success. About half of the cases of transplantation of the hamstrings to the femur, division or elongation of the hamstrings, or supracondylar osteotomy had successful results. Transfer of the hamstring tendons to the patella was successful in nine of twelve instances, so giving the lowest rate of failure. Forty-five patients were active walkers at follow-up as compared to eighteen before operation. However, only one of the eleven patients over twelve years of age with a motor level above T.12 was an active walker at review. Several conclusions are drawn. A flexion contracture of the hip greater than 30 degress should be corrected before operation of the knee. Supracondylar osteotomy as a primary procedure should only be used to correct flexion contracture of the knee secondary to malunited fractures. Faradic stimulation is useful in the evaluation of muslce function before operation. An intelligence quotient below 65 and weakness of the arms are relative contraindications for correction of the deformity of the knee


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 928 - 935
1 Jul 2014
Matharu GS McBryde CW Robb CA Pynsent PB

The Oxford hip and knee scores (OHS and OKS) are validated patient-reported outcome measures used in patients undergoing total hip replacement (THR), hip resurfacing (HR), total knee replacement (TKR) and unicompartmental knee replacement (UKR). We analysed the absolute OHS and OKS and change in scores following THR, HR, TKR, and UKR performed at one specialist centre. All patients undergoing and completing at least one Oxford score were eligible for inclusion in the study which included 27 950 OHS and 19 750 OKS in 13 682 patients. Data were analysed using non-linear quantile regression. The median absolute Oxford scores for THR, HR, TKR and UKR were pre-operative 68.8% (15.0/48), 58.3% (20.0/48), 66.7% (16.0/48), 60.4% (19.0/48) respectively: and post-operative asymptote was 14.6% (41.0/48), 5.8% (45.2/48), 31.2% (33.0/48), 29.2% (34.0/48). The median asymptotic change from the pre-operative score for THR, HR, TKR and UKR were 47.9% (23.0/48), 47.9% (23.0/48), 33.3% (16.0/48) and 32.4% (15.5/48), respectively. The median time at which no further appreciable change in score was achieved post-operatively was 0.7 years for THR, 1.1 years for HR, 0.9 years for TKR and 1.1 years for UKR. The curves produced from this analysis could be used to educate patients, and to audit the performance of a surgeon and an institution. The time to achieve a stable improvement in outcome varied between different types of joint replacement, which may have implications for the timing of post-operative review. Cite this article: Bone Joint J 2014; 96-B:928–35


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1366 - 1372
1 Oct 2009
Abed YY Beltrami G Campanacci DA Innocenti M Scoccianti G Capanna R

We reviewed 25 patients who had undergone resection of a primary bone sarcoma which extended to within 5 cm of the knee with reconstruction by a combination of a free vascularised fibular graft and a massive allograft bone shell. The distal femur was affected in four patients and the proximal tibia in 21. Their mean age at the time of operation was 19.7 years (5 to 52) and the mean follow-up period 140 months (28 to 213). Three vascularised transfers failed. The mean time to union of the fibula was 5.6 months (3 to 10) and of the allograft 19.6 months (10 to 34). Full weight-bearing was allowed at a mean of 21.4 months (14 to 36). The mean functional score at final follow-up was 27.4 (18 to 30) using a modfied 30-point Musculoskeletal Tumour Society rating system. The overall limb-salvage rate was 88%. The results of our study suggest that the combined use of a vascularised fibular graft and allograft is of value as a limb-salvage procedure for intercalary reconstruction after resection of bone tumours around the knee, especially in skeletally immature patients


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 8 | Pages 1133 - 1136
1 Nov 2004
Tokuhara Y Kadoya Y Nakagawa S Kobayashi A Takaoka K

Varus and valgus joint laxity of the normal living knee in flexion was assessed using MRI. Twenty knees were flexed to 90° and were imaged in neutral and under a varus-valgus stress in an open MRI system. The configuration of the tibiofemoral joint gap was studied in slices which crossed the epicondyles of the femur. When a varus stress was applied, the lateral joint gap opened by 6.7 ± 1.9 mm (mean ± . sd. ; 2.1 to 9.2) whereas the medial joint gap opened by only by a mean of 2.1 ± 1.1 mm (0.2 to 4.2). These discrepancies indicate that the tibiofemoral flexion gap in the normal knee is not rectangular and that the lateral joint gap is significantly lax. These results may be useful for adequate soft-tissue balancing and bone resection in total knee arthroplasty and reconstruction surgery on ligaments


Bone & Joint 360
Vol. 5, Issue 6 | Pages 18 - 21
1 Dec 2016


The Journal of Bone & Joint Surgery British Volume
Vol. 37-B, Issue 3 | Pages 392 - 399
1 Aug 1955
London PS

1. Synovectomy was carried out in thirty-four knees, of which thirty-one were certainly or probably afflicted by rheumatoid arthritis. 2. Synovectomy was considered only when adequate medical and physical treatment had failed to afford relief. Its purpose is to preserve useful function, and one of the principal factors influencing the decision to operate was the retention of a normal or good radiographic joint space in a persistently painful, warm and swollen knee. 3. Radiographic appearances constituted a useful but not infallible guide to the true state of the articular surfaces. 4. The method of operation, findings and subsequent care are described. 5. Up to two years after operation it appeared that improvement might be related to the state of the articular surfaces, but after two years this relationship was not evident and an attempt to explain this difference has been made. 6. It seems clear that the longer-term results are determined mainly by the course taken by the rheumatoid process. An unfavourable course was associated with considerably less satisfactory results than was a favourable course. 7. It is concluded that in rheumatoid arthritis which has resisted rest and medical treatment synovectomy of the knee is most likely to be successful when the radiographic joint space is good or normal, and when the rheumatoid process follows a favourable course. To undertake the operation at an early stage in the disease is to leave in doubt the outcome, as this is dependent upon the as yet undeclared general course of the disease. Even so, early synovectomy is worth considering when nothing else has given relief. The fact that arthrodesis has only once been necessary after synovectomy appears to justify the policy of salvage described


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 318 - 323
1 Mar 2015
Verdonk P Dhollander A Almqvist KF Verdonk R Victor J

The treatment of osteochondral lesions is of great interest to orthopaedic surgeons because most lesions do not heal spontaneously. We present the short-term clinical outcome and MRI findings of a cell-free scaffold used for the treatment of these lesions in the knee. A total of 38 patients were prospectively evaluated clinically for two years following treatment with an osteochondral nanostructured biomimetic scaffold. There were 23 men and 15 women; the mean age of the patients was 30.5 years (15 to 64). Clinical outcome was assessed using the Knee Injury and Osteoarthritis Outcome Score (KOOS), the Tegner activity scale and a Visual Analgue scale for pain. MRI data were analysed based on the Magnetic Resonance Observation of Cartilage Repair Tissue (MOCART) scoring system at three, 12 and 24 months post-operatively. There was a continuous significant clinical improvement after surgery. In two patients, the scaffold treatment failed (5.3%) There was a statistically significant improvement in the MOCART precentage scores. The repair tissue filled most of the defect sufficiently. We found subchondral laminar changes in all patients. Intralesional osteophytes were found in two patients (5.3%). We conclude that this one-step scaffold-based technique can be used for osteochondral repair. The surgical technique is straightforward, and the clinical results are promising. The MRI aspects of the repair tissue continue to evolve during the first two years after surgery. However, the subchondral laminar and bone changes are a concern. Cite this article: Bone Joint J 2015; 97-B:318–23


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 1 | Pages 42 - 43
1 Jan 1985
Johnson-Nurse C Dandy D

Seventy-six knees with fracture-separations of articular cartilage are described. The lesion involved the full thickness of the articular surface with exposed subchondral bone in 28 knees and only part of the thickness in 48. The clinical features and distribution of the lesions within the knee are described


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 1 | Pages 43 - 47
1 Jan 2004
Ritter MA Faris PM Thong AE Davis KE Meding JB Berend ME

Interest in unicompartmental knee arthroplasty (UKA) for the treatment of medial compartment osteoarthritis has increased in recent years with apparent improvement in the long-term results. This is a result of improved surgical technique, patient selection, and implant design. In an effort further to improve patient selection we analysed the relationship between the pre-operative alignment of the knee and the anatomical findings at the time of surgery. We compared these findings with the indications for UKA. From 4021 total knee arthroplasties we compared intra-operative observations with the pre-operative clinical data in order to identify knees with isolated, medial, compartment changes, which would have been ideal candidates for UKA. We found that only 247 of the knees (6.1%) met anatomical qualifications for isolated, medial, unicompartmental osteoarthritis, and of these, only 168 (4.3%) met clinical standards ideal for UKA. Pre-operative alignment showed a significant relationship with patterns of disease. Logistic regression revealed a relationship between pre-operative alignment and intra-operative findings resembling a Gaussian distribution. Patients with a pre-operative varus alignment of 7° were slightly more likely to be selected for UKA. But the further the anatomical alignment in either direction varies from 7° of varus, the more unlikely it is for the knee to exhibit a disease pattern of isolated, medial, unicompartmental osteoarthritis


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 3 | Pages 345 - 347
1 Apr 2001
Harcourt WGV White SH Jones P

There is a need for the accurate measurement of the outcome after knee surgery. The Oxford Knee Score is being increasingly used since it is reported to be short, simple, inexpensive and validated. We sent the questionnaire to 346 patients awaiting surgery to the hip or lumbar spine. Only 11% of 141 patients with proximal pathology who denied knee problems gave a maximum score. Their mean score was substantially lower than expected at 28.7 (maximum 48), and was significantly lower than the score of 36.5 obtained from patients after total knee replacement. We therefore suggest that the frequent coexistence of hip or spinal pathology will significantly alter both the absolute score and any improvement to be expected after knee surgery. Although sensitive to disability originating from the knee the Oxford Knee Score is not sufficiently specific since it is heavily influenced by more proximal pathology


Bone & Joint 360
Vol. 5, Issue 5 | Pages 13 - 17
1 Oct 2016


The Journal of Bone & Joint Surgery British Volume
Vol. 53-B, Issue 3 | Pages 507 - 509
1 Aug 1971
Chamberlain MA

1. Eight patients with rheumatoid arthritis had an intra-articular nodule in one or both knees causing mechanical symptoms. 2. The nodule was on the lateral side of the knee and interfered with walking. It caused a click and painful instability of the knee at about 15 degrees of flexion. 3. Surgical excision of the nodule, which was attached to the synovial membrane, abolished the symptoms


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 1 | Pages 29 - 32
1 Jan 2001
Hulet CH Locker BG Schiltz D Texier A Tallier E Vielpeau CH

We reviewed 74 partial medial meniscectomies in 57 patients with stable knees, to assess the long-term functional and radiological outcome. The International Knee Documentation Committee score and the residual laxity were assessed in both knees. At the time of surgery the mean age of the patients was 36 ± 11 years and the mean follow-up was 12 ± 1 years. All had a limited medial meniscectomy. The anterior cruciate ligament was intact in all cases. The meniscal tear was vertical in 95% and complex in 5%. The posterior part of the meniscus was removed in 99%. A peripheral rim was preserved in all cases. After 12 years 95% of the patients were satisfied or very satisfied with their knee(s). Objectively, 57% had grade A function and 43% were grade B. The outcome correlated only with the presence of anterior knee pain at final follow-up. In the 49 cases of arthroscopic meniscectomy for which there was a contralateral normal knee there was narrowing of the ‘joint-space’ in 16% of the operated knees. There was no correlation between this and other parameters such as age or different meniscal pathologies


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 5 | Pages 819 - 824
1 Nov 1989
Amis A

The anteroposterior stability of cadaveric knees was investigated. There was a wide range of normal laxity; knees were more stable at 90 degrees than at 20 degrees flexion. Anterior cruciate ligament implants with different stiffnesses were inserted; normal stability could always be restored, and the stiffness or extensibility of implants did not affect knee behaviour significantly. The tightness of implants was critical--small tensioning errors caused subluxation, inhibited knee extension and allowed damagingly high implant tensions. It is concluded that the tension of ligament implants could not be adjusted simply with a pre-set instrument; the procedure will remain critically dependent on the judgment of the operating surgeon


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 900 - 904
1 Jul 2006
Din R Annear P Scaddan J

A total of 11 patients (12 knees) with stable lesions of osteochondritis dissecans of the knee underwent arthroscopic fixation of the fragments using polylactide bioabsorbable pins. The site of the lesion was the medial femoral condyle in ten knees and the lateral femoral condyle in two. The mean age of the patients was 14.8 years (12 to 16). At a mean follow-up of 32.4 months (13 to 38 months) all fragments had MRI evidence of union. One patient developed early transient synovitis, which resolved with non-steroidal anti-inflammatory medication. All patients returned to sporting activities within eight months of operation and did not require a period of immobilisation


The Journal of Bone & Joint Surgery British Volume
Vol. 60-B, Issue 3 | Pages 345 - 352
1 Aug 1978
Denham R Bishop R

Static force transmission at the knee is analysed using measurements from radiographs showing the position of the line of body weight and also the bones of the knee in their correct orientation during function. With this technique it is possible to suggest values for a variety of forces acting at the knee. During function the degree of knee flexion is not as important as the angle that the thigh makes with the vertical. The tension in the extensor mechanism is not the same above and below the patella. Failure to recognise these two features results in fundamental errors. The patella, the effects of patellectomy and of forward displacement of the attachment of the patellar ligament are discussed. The importance of the transmission of force in the coronal plane is emphasised with particular reference to total knee replacement. It is suggested that small errors of geometry, as seen in the anteroposterior radiograph, can produce large changes of load