Advertisement for orthosearch.org.uk
Results 321 - 340 of 444
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1025 - 1031
1 Aug 2008
Mizu-uchi H Matsuda S Miura H Okazaki K Akasaki Y Iwamoto Y

We compared the alignment of 39 total knee replacements implanted using the conventional alignment guide system with 37 implanted using a CT-based navigation system, performed by a single surgeon. The knees were evaluated using full-length weight-bearing anteroposterior radiographs, lateral radiographs and CT scans.

The mean hip-knee-ankle angle, coronal femoral component angle and coronal tibial component angle were 181.8° (174.2° to 188.3°), 88.5° (84.0° to 91.8°) and 89.7° (86.3° to 95.1°), respectively for the conventional group and 180.8° (178.2° to 185.1°), 89.3° (85.8° to 92.0°) and 89.9° (88.0° to 93.0°), respectively for the navigated group.

The mean sagittal femoral component angle was 85.5° (80.6° to 92.8°) for the conventional group and 89.6° (85.5° to 94.0°) for the navigated group.

The mean rotational femoral and tibial component angles were −0.7° (−8.8° to 9.8°) and −3.3° (−16.8° to 5.8°) for the conventional group and −0.6° (−3.5° to 3.0°) and 0.3° (−5.3° to 7.7°) for the navigated group.

The ideal angles of all alignments in the navigated group were obtained at significantly higher rates than in the conventional group. Our results demonstrated significant improvements in component positioning with a CT-based navigation system, especially with respect to rotational alignment.


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 93 - 95
1 Nov 2014
Gehrke T Kendoff D Haasper C

The use of hinged implants in primary total knee replacement (TKR) should be restricted to selected indications and mainly for elderly patients. Potential indications for a rotating hinge or pure hinge implant in primary TKR include: collateral ligament insufficiency, severe varus or valgus deformity (> 20°) with necessary relevant soft-tissue release, relevant bone loss including insertions of collateral ligaments, gross flexion-extension gap imbalance, ankylosis, or hyperlaxity. Although data reported in the literature are inconsistent, clinical results depend on implant design, proper technical use, and adequate indications. We present our experience with a specific implant type that we have used for over 30 years and which has given our elderly patients good mid-term results. Because revision of implants with long cemented stems can be very challenging, an effort should be made in the future to use shorter stems in modular versions of hinged implants.

Cite this article: Bone Joint J 2014;96-B(11 Suppl A):93–5.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 190 - 193
1 Feb 2012
Koh Y Moon H Kim Y Park Y Jo S Kwon S

We compared extrusion of the allograft after medial and lateral meniscal allograft transplantation and examined the correlation between the extent of extrusion and the clinical outcome. A total of 73 lateral and 26 medial meniscus allografts were evaluated by MRI at a mean of 32 months (24 to 59) in 99 patients (67 men, 32 women) with a mean age of 35 years (21 to 52). The absolute values and the proportional widths of extruded menisci as a percentage were measured in coronal images that showed maximum extrusion. Functional assessments were performed using Lysholm scores. The mean extrusion was 4.7 mm (1.8 to 7.7) for lateral menisci and 2.9 mm (1.2 to 6.5) for medial menisci (p < 0.001), and the mean percentage extrusions were 52.0% (23.8% to 81.8%) and 31.2% (11.6% to 63.4%), respectively (p < 0.001). Mean Lysholm scores increased significantly from 49.0 (10 to 83) pre-operatively to 86.6 (33 to 99) at final follow-up for lateral menisci (p = 0.001) and from 50.9 (15 to 88) to 88.3 (32 to 100) for medial menisci (p < 0.001). The final mean Lysholm scores were similar in the two groups (p = 0.312). Furthermore, Lysholm scores were not found to be correlated with degree of extrusion (p = 0.242).

Thus, transplanted lateral menisci extrude more significantly than transplanted medial menisci. However, the clinical outcome after meniscal transplantation was not found to be adversely affected by extrusion of the allograft.


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 118 - 121
1 Nov 2014
Lachiewicz PF Watters TS

Metaphyseal bone loss is common with revision total knee replacement (RTKR). Using the Anderson Orthopaedic Research Institute (AORI) classification, type 2-B and type 3 defects usually require large metal blocks, bulk structural allograft or highly porous metal cones. Tibial and femoral trabecular metal metaphyseal cones are a unique solution for large bone defects. These cones substitute for bone loss, improve metaphyseal fixation, help correct malalignment, restore the joint line and may permit use of a shorter stem. The technique for insertion involves sculpturing of the remaining bone with a high speed burr and rasp, followed by press-fit of the cone into the metaphysis. The fixation and osteoconductive properties of the porous cone outer surface allow ingrowth and encourage long-term biological fixation. The revision knee component is then cemented into the porous cone inner surface, which provides superior fixation compared with cementing into native but deficient metaphyseal bone. The advantages of the cone compared with allograft include: technical ease, biological fixation, no resorption, and possibly a lower risk of infection. The disadvantages include: difficult extraction and relatively short-term follow-up. Several studies using cones report promising short-term results for the reconstruction of large bone defects in RTKR.

Cite this article: Bone Joint J 2014;96-B(11 Suppl A):118–21.


Bone & Joint Research
Vol. 2, Issue 1 | Pages 1 - 8
1 Jan 2013
Costa AJ Lustig S Scholes CJ Balestro J Fatima M Parker DA

Objectives

There remains a lack of data on the reliability of methods to estimate tibial coverage achieved during total knee replacement. In order to address this gap, the intra- and interobserver reliability of a three-dimensional (3D) digital templating method was assessed with one symmetric and one asymmetric prosthesis design.

Methods

A total of 120 template procedures were performed according to specific rotational and over-hang criteria by three observers at time zero and again two weeks later. Total and sub-region coverage were calculated and the reliability of the templating and measurement method was evaluated.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 11 | Pages 1493 - 1496
1 Nov 2011
Lee JK Choi CH

Bone defects are occasionally encountered during primary total knee replacement (TKR) and cause difficulty in establishing a stable well-aligned bone-implant interface. Between March 1999 and November 2005, 59 knees in 43 patients underwent primary TKR with a metal block augmentation for tibial bone deficiency. In all, six patients (eight knees) died less than four years post-operatively, and four patients (five knees) were lost to follow-up leaving 46 knees in 33 patients available for review at a mean of 78.6 months (62 to 129). The clinical results obtained, including range of movement, American Knee Society and Oxford knee scores, and the Western Ontario and McMaster Universities osteoarthritis index, were good to excellent, with no failures. Radiolucent lines at the block-cement-bone interface were noted in five knees (11%) during the first post-operative year, but these did not progress.

Modular rectangular metal augmentation for tibial bone deficiency is a useful option. No deterioration of the block-prosthesis or block-cement-bone interface was seen at minimum of five years follow-up.


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 87 - 92
1 Nov 2014
Kwong LM Nielsen ESN Ruiz DR Hsu AH Dines MD Mellano CM

A retrospective review was performed of patients undergoing primary cementless total knee replacement (TKR) using porous tantalum performed by a group of surgical trainees. Clinical and radiological follow-up involved 79 females and 26 males encompassing 115 knees. The mean age was 66.9 years (36 to 85). Mean follow-up was 7 years (2 to 11). Tibial and patellar components were porous tantalum monoblock implants, and femoral components were posterior stabilised (PS) in design with cobalt–chromium fibre mesh. Radiological assessments were made for implant positioning, alignment, radiolucencies, lysis, and loosening. There was 95.7% survival of implants. There was no radiological evidence of loosening and no osteolysis found. No revisions were performed for aseptic loosening. Average tibial component alignment was 1.4° of varus (4°of valgus to 9° varus), and 6.2° (3° anterior to 15° posterior) of posterior slope. Mean femoral component alignment was 6.6° (1° to 11°) of valgus. Mean tibiofemoral alignment was 5.6° of valgus (7° varus to 16° valgus). Patellar tilt was a mean of 2.4° lateral (5° medial to 28° lateral). Patient satisfaction with improvement in pain was 91%. Cementless TKR incorporating porous tantalum yielded good clinical and radiological outcomes at a mean of follow-up of seven-years.

Cite this article: Bone Joint J 2014;96-B(11 Suppl A):87–92.


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1644 - 1648
1 Dec 2014
Abdel MP Pulido L Severson EP Hanssen AD

Instability in flexion after total knee replacement (TKR) typically occurs as a result of mismatched flexion and extension gaps. The goals of this study were to identify factors leading to instability in flexion, the degree of correction, determined radiologically, required at revision surgery, and the subsequent clinical outcomes. Between 2000 and 2010, 60 TKRs in 60 patients underwent revision for instability in flexion associated with well-fixed components. There were 33 women (55%) and 27 men (45%); their mean age was 65 years (43 to 82). Radiological measurements and the Knee Society score (KSS) were used to assess outcome after revision surgery. The mean follow-up was 3.6 years (2 to 9.8). Decreased condylar offset (p < 0.001), distalisation of the joint line (p < 0.001) and increased posterior tibial slope (p < 0.001) contributed to instability in flexion and required correction at revision to regain stability. The combined mean correction of posterior condylar offset and joint line resection was 9.5 mm, and a mean of 5° of posterior tibial slope was removed. At the most recent follow-up, there was a significant improvement in the mean KSS for the knee and function (both p < 0.001), no patient reported instability and no patient underwent further surgery for instability.

The following step-wise approach is recommended: reduction of tibial slope, correction of malalignment, and improvement of condylar offset. Additional joint line elevation is needed if the above steps do not equalise the flexion and extension gaps.

Cite this article: Bone Joint J 2014;96-B:1644–8.


Bone & Joint 360
Vol. 3, Issue 3 | Pages 39 - 40
1 Jun 2014
Arastu M


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1193 - 1197
1 Sep 2008
El-Azab H Halawa A Anetzberger H Imhoff AB Hinterwimmer S

Radiographs of 110 patients who had undergone 120 high tibial osteotomies (60 closed-wedge, 60 open-wedge) were assessed for posterior tibial slope before and after operation, and before removal of the hardware. In the closed-wedge group the mean slope was 5.7° (sd 3.8) before and 2.4° (sd 3.9) immediately after operation, and 2.4° (sd 3.4) before removal of the hardware. In the open-wedge group, these values were 5.0° (sd 3.7), 7.7° (sd 4.3) and 8.1° (sd 3.9) respectively, when stabilised with a non-locking plate, and 7.7° (sd 3.5), 9.4° (sd 4.1) and 9.1° (sd 3.8), when stabilised with a locking plate. The reduction in slope (−2.7° (sd 4.1)) in the closed-wedge group and the increase (+2.5° (sd 3.4), in the open-wedge group was significantly different before and after operation (p = 0.002, p = 0.003). In no group were the changes in slope directly after operation and before removal of the hardware significant (p > 0.05). There was no correlation between the amount of correction in the frontal plane and the post-operative change in slope.

Posterior tibial slope decreases after closed-wedge high tibial osteotomy and increases after an open-wedge procedure because of the geometry of the proximal tibia. The changes in the slope are stable over time, emphasising the influence of the operative procedure rather than of the implant.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 668 - 673
1 May 2008
Karva AR Board TN Porter ML

We present a 25-year-old patient with juvenile rheumatoid arthritis and ankylosis of both hips and both knees treated by staged bilateral hip and knee arthroplasty. She was followed up for 18 months. We discuss the pre-operative planning, surgical details and post-operative rehabilitation.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 58 - 63
1 Jan 2009
Hooper G Rothwell A Frampton C

We have examined the outcome of 400 consecutive patients who underwent total knee replacement with the Low Contact Stress mobile-bearing system between 1993 and 1994 and were followed up for a minimum of ten years. All operations were performed by surgeons in Christchurch, New Zealand, who used no other knee prosthesis during the study time.

At ten years after operation 238 patients (244 knees) remained for independent clinical and radiological assessment. There was a significant improvement (p < 0.001) in the postoperative knee scores at one, three, seven and ten years, although a slight deterioration in the score occurred between seven and ten years which did not reach statistical significance. The survival for polyethylene wear or loosening was 97% (95% CI 96 to 98) and survival using reoperation for any cause was 92% (95% CI 90 to 94) at 12 years. Polyethylene wear was more common in the meniscal-bearing component, with five knees requiring revision and a further eight demonstrating early wear. Osteolysis was not seen in the rotating platform component, but was present in three of the meniscal-bearing knees.

There was no association between the radiological alignment at one year and those knees that subsequently required revision. However, there was an association between the overall limb alignment and the Western Ontario McMasters University score (p < 0.001).

The Low Contact Stress mobile-bearing total knee replacement has proved to be a reliable implant at ten years when used in primary knee replacement irrespective of the deformity and diagnosis.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 4 | Pages 494 - 499
1 Apr 2008
Howells NR Gill HS Carr AJ Price AJ Rees JL

The aim of this study was to investigate the effect of laboratory-based simulator training on the ability of surgical trainees to perform diagnostic arthroscopy of the knee.

A total of 20 junior orthopaedic trainees were randomised to receive either a fixed protocol of arthroscopic simulator training on a bench-top knee simulator or no additional training. Motion analysis was used to assess performance objectively. Each trainee then received traditional instruction and demonstrations of diagnostic arthroscopy of the knee in theatre before performing the procedure under the supervision of a blinded consultant trainer. Their performance was assessed using a procedure-based assessment from the Orthopaedic Competence Assessment Project and a five-point global rating assessment scale.

In theatre the simulator-trained group performed significantly better than the untrained group using the Orthopaedic Competence Assessment Project score (p = 0.0007) and assessment by the global rating scale (p = 0.0011), demonstrating the transfer of psychomotor skills from simulator training to arthroscopy in the operating theatre. This has implications for the planning of future training curricula.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 142 - 150
1 Feb 2005
Keating JF Simpson AHRW Robinson CM


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 569 - 573
1 May 2014
Sullivan MP McHale KJ Parvizi J Mehta S

Nanotechnology is the study, production and controlled manipulation of materials with a grain size < 100 nm. At this level, the laws of classical mechanics fall away and those of quantum mechanics take over, resulting in unique behaviour of matter in terms of melting point, conductivity and reactivity. Additionally, and likely more significant, as grain size decreases, the ratio of surface area to volume drastically increases, allowing for greater interaction between implants and the surrounding cellular environment. This favourable increase in surface area plays an important role in mesenchymal cell differentiation and ultimately bone–implant interactions.

Basic science and translational research have revealed important potential applications for nanotechnology in orthopaedic surgery, particularly with regard to improving the interaction between implants and host bone. Nanophase materials more closely match the architecture of native trabecular bone, thereby greatly improving the osseo-integration of orthopaedic implants. Nanophase-coated prostheses can also reduce bacterial adhesion more than conventionally surfaced prostheses. Nanophase selenium has shown great promise when used for tumour reconstructions, as has nanophase silver in the management of traumatic wounds. Nanophase silver may significantly improve healing of peripheral nerve injuries, and nanophase gold has powerful anti-inflammatory effects on tendon inflammation.

Considerable advances must be made in our understanding of the potential health risks of production, implantation and wear patterns of nanophase devices before they are approved for clinical use. Their potential, however, is considerable, and is likely to benefit us all in the future.

Cite this article: Bone Joint J 2014; 96-B: 569–73.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 11 | Pages 1440 - 1448
1 Nov 2011
Dodds AL Gupte CM Neyret P Williams AM Amis AA

This annotation considers the place of extra-articular reconstruction in the treatment of anterior cruciate ligament (ACL) deficiency. Extra-articular reconstruction has been employed over the last century to address ACL deficiency. However, the technique has not gained favour, primarily due to residual instability and the subsequent development of degenerative changes in the lateral compartment of the knee. Thus intra-articular reconstruction has become the technique of choice. However, intra-articular reconstruction does not restore normal knee kinematics. Some authors have recommended extra-articular reconstruction in conjunction with an intra-articular technique.

The anatomy and biomechanics of the anterolateral structures of the knee remain largely undetermined. Further studies to establish the structure and function of the anterolateral structures may lead to more anatomical extra-articular reconstruction techniques that supplement intra-articular reconstruction. This might reduce residual pivot shift after an intra-articular reconstruction and thus improve the post-operative kinematics of the knee.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 1 | Pages 31 - 36
1 Jan 2008
Yoo JH Kang YG Chang CB Seong SC Kim TK

We examined the placement of the stem in relation to the medial tibial cortex when using total knee replacements (TKRs) with medially-offset tibial stems in Korean patients. Measurements were performed on the pre- and post-operative radiographs of 246 osteoarthritic knees replaced between January 2005 and May 2006 using the Genesis II or E-motion TKR with a medially-offset stem. Pre-operatively, we measured the distance between the mechanical axis and that of the tibial shaft and post-operatively, that between the midline of the tibial stem and the axis of the shaft.

Knees were identified in which there was radiological contact between the tip of the stem and the medial tibial cortex. The mechanical axis was located medial to the axis of the shaft in 203 knees (82.5%). Post-operatively, the midline of the tibial stem was located medial to the tibial shaft axis in 196 knees (79.7%). In 16 knees (6.5%) there was radiological contact between the tibial stem or cement mantle and the medial tibial cortex.

Our study has shown that the medially-offset stem in the tibial component may not be a good option for knees undergoing replacement for advanced osteoarthritis in some Korean patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1466 - 1470
1 Oct 2010
Didden K Luyckx T Bellemans J Labey L Innocenti B Vandenneucker H

The biomechanics of the patellofemoral joint can become disturbed during total knee replacement by alterations induced by the position and shape of the different prosthetic components. The role of the patella and femoral trochlea has been well studied. We have examined the effect of anterior or posterior positioning of the tibial component on the mechanisms of patellofemoral contact in total knee replacement. The hypothesis was that placing the tibial component more posteriorly would reduce patellofemoral contact stress while providing a more efficient lever arm during extension of the knee.

We studied five different positions of the tibial component using a six degrees of freedom dynamic knee simulator system based on the Oxford rig, while simulating an active knee squat under physiological loading conditions. The patellofemoral contact force decreased at a mean of 2.2% for every millimetre of posterior translation of the tibial component. Anterior positions of the tibial component were associated with elevation of the patellofemoral joint pressure, which was particularly marked in flexion > 90°.

From our results we believe that more posterior positioning of the tibial component in total knee replacement would be beneficial to the patellofemoral joint.


The Bone & Joint Journal
Vol. 96-B, Issue 7 | Pages 857 - 862
1 Jul 2014
Abdel MP Oussedik S Parratte S Lustig S Haddad FS

Substantial healthcare resources have been devoted to computer navigation and patient-specific instrumentation systems that improve the reproducibility with which neutral mechanical alignment can be achieved following total knee replacement (TKR). This choice of alignment is based on the long-held tenet that the alignment of the limb post-operatively should be within 3° of a neutral mechanical axis. Several recent studies have demonstrated no significant difference in survivorship when comparing well aligned versus malaligned TKRs. Our aim was to review the anatomical alignment of the knee, the historical and contemporary data on a neutral mechanical axis in TKR, and the feasibility of kinematically-aligned TKRs.

Review of the literature suggests that a neutral mechanical axis remains the optimal guide to alignment.

Cite this article: Bone Joint J 2014;96-B:857–62.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 1 | Pages 34 - 38
1 Jan 2007
Epinette J Manley MT

This study describes 146 primary total knee replacements, either fully or partially coated with hydroxyapatite of which 74 knees in 68 patients were available for clinical and radiological assessment at a mean of 11.2 years (10 to 15). The global failure rate was 1.37% and survival rate with mechanical failure as the end-point was 98.14%. Radiological assessment indicated intimate contact between bone and the hydroxyapatite coating. Over time the hydroxyapatite coating appears to encourage filling of interface gaps remaining after surgery. Our results compare favourably with those of series describing cemented or porous-coated knee replacements, and suggest that fixation with hydroxyapatite is a reliable option in primary total knee replacement.