Aims. Assessment of bone mineral density (BMD) with dual-energy X-ray absorptiometry (DXA) is a well-established clinical technique, but it is not available in the acute
Aims. The aim of this study was to determine the current incidence and epidemiology of humeral diaphyseal fractures. The secondary aim was to explore variation in patient and injury characteristics by fracture location within the humeral diaphysis. Methods. Over ten years (2008 to 2017), all adult patients (aged ≥ 16 years) sustaining an acute fracture of the humeral diaphysis managed at the study centre were retrospectively identified from a
Aims. The aim of this study was to investigate whether on-demand removal (ODR) is noninferior to routine removal (RR) of syndesmotic screws regarding functional outcome. Methods. Adult patients (aged above 17 years) with traumatic syndesmotic injury, surgically treated within 14 days of
Aims. Orthopaedic infection is a potentially serious complication of elective and emergency
Aims. The number of convolutional neural networks (CNN) available for fracture detection and classification is rapidly increasing. External validation of a CNN on a temporally separate (separated by time) or geographically separate (separated by location) dataset is crucial to assess generalizability of the CNN before application to clinical practice in other institutions. We aimed to answer the following questions: are current CNNs for fracture recognition externally valid?; which methods are applied for external validation (EV)?; and, what are reported performances of the EV sets compared to the internal validation (IV) sets of these CNNs?. Methods. The PubMed and Embase databases were systematically searched from January 2010 to October 2020 according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. The type of EV, characteristics of the external dataset, and diagnostic performance characteristics on the IV and EV datasets were collected and compared. Quality assessment was conducted using a seven-item checklist based on a modified Methodologic Index for NOn-Randomized Studies instrument (MINORS). Results. Out of 1,349 studies, 36 reported development of a CNN for fracture detection and/or classification. Of these, only four (11%) reported a form of EV. One study used temporal EV, one conducted both temporal and geographical EV, and two used geographical EV. When comparing the CNN’s performance on the IV set versus the EV set, the following were found: AUCs of 0.967 (IV) versus 0.975 (EV), 0.976 (IV) versus 0.985 to 0.992 (EV), 0.93 to 0.96 (IV) versus 0.80 to 0.89 (EV), and F1-scores of 0.856 to 0.863 (IV) versus 0.757 to 0.840 (EV). Conclusion. The number of externally validated CNNs in
Aims. The study objective was to prospectively assess clinical outcomes for a pilot cohort of tibial shaft fractures treated with a new tibial nailing system that produces controlled axial interfragmentary micromotion. The hypothesis was that axial micromotion enhances fracture healing compared to static interlocking. Methods. Patients were treated in a single level I
Aims. The impact of concomitant injuries in patients with proximal femoral fractures has rarely been studied. To date, the few studies published have been mostly single-centre research focusing on the influence of upper limb fractures. A retrospective cohort analysis was, therefore, conducted to identify the impact and distribution of concomitant injuries in patients with proximal femoral fractures. Methods. A retrospective, multicentre registry-based study was undertaken. Between 1 January 2016 and 31 December 2019, data for 24,919 patients from 100 hospitals were collected in the Registry for Geriatric
Aims. Tibial plateau fractures (TPFs) are complex injuries around the knee caused by high- or low-energy
Aims. The follow-up interval of a study represents an important aspect that is frequently mentioned in the title of the manuscript. Authors arbitrarily define whether the follow-up of their study is short-, mid-, or long-term. There is no clear consensus in that regard and definitions show a large range of variation. It was therefore the aim of this study to systematically identify clinical research published in high-impact orthopaedic journals in the last five years and extract follow-up information to deduce corresponding evidence-based definitions of short-, mid-, and long-term follow-up. Methods. A systematic literature search was performed to identify papers published in the six highest ranked orthopaedic journals during the years 2015 to 2019. Follow-up intervals were analyzed. Each article was assigned to a corresponding subspecialty field: sports traumatology, knee arthroplasty and reconstruction, hip-preserving surgery, hip arthroplasty, shoulder and elbow arthroplasty, hand and wrist, foot and ankle, paediatric orthopaedics,
Aims. The aim of this study was to describe the epidemiology of closed
isolated fractures of the femoral shaft in children, and to compare
the treatment and length of stay (LOS) between major
Aims. Open tibial fractures are limb-threatening injuries. While limb loss is rare in children, deep infection and nonunion rates of up to 15% and 8% are reported, respectively. We manage these injuries in a similar manner to those in adults, with a combined orthoplastic approach, often involving the use of vascularised free flaps. We report the orthopaedic and plastic surgical outcomes of a consecutive series of patients over a five-year period, which includes the largest cohort of free flaps for
Aims. Complex fractures of the femur and tibia with associated severe soft tissue injury are often devastating for the individual. The aim of this study was to describe the two-year patient-reported outcomes of patients in a civilian population who sustained a complex fracture of the femur or tibia with a Mangled Extremity Severity Score (MESS) of ≥ 7, whereby the score ranges from 2 (lowest severity) to 11 (highest severity). Methods. Patients aged ≥ 16 years with a fractured femur or tibia and a MESS of ≥ 7 were extracted from the Victorian
Aim. The primary aim of this retrospective study was to identify the
incidence of heterotopic ossification (HO) following elective and
trauma elbow arthroplasty. The secondary aim was to determine clinical
outcomes with respect to the formation of heterotopic ossification. Patients and Methods. A total of 55 total elbow arthroplasties (TEAs) (52 patients)
performed between June 2007 and December 2015 were eligible for
inclusion in the study (29 TEAs for primary elective arthroplasty
and 26 TEAs for trauma). At review, 15 patients (17 total elbow
arthroplasties) had died from unrelated causes. There were 14 men
and 38 women with a mean age of 70 years (42 to 90). The median
clinical follow-up was 3.6 years (1.2 to 6) and the median radiological follow-up
was 3.1 years (0.5 to 7.5). Results. The overall incidence of HO was 84% (46/55). This was higher
in the
Aims. The aim of this study was to explore whether time to surgery affects functional outcome in displaced proximal humeral fractures. Methods. A total of 250 patients presenting within three weeks of sustaining a displaced proximal humeral fracture involving the surgical neck were recruited at 32 acute NHS hospitals in the United Kingdom between September 2008 and April 2011. Of the 125 participants, 109 received surgery (fracture fixation or humeral head replacement) as per randomization. Data were included for 101 and 67 participants at six-month and five-year follow-up, respectively. Oxford Shoulder Scores (OSS) collected at six, 12, and 24 months and at three, four, and five years following randomization was plotted against time to surgery. Long-term recovery was explored by plotting six-month scores against five-year scores and agreement was illustrated with a Bland-Altman plot. Results. The mean time from initial
Aims. High-energy injuries can result in multiple complications, the most prevalent being infection. Vancomycin powder has been used with increasing frequency in
Aims. This study sought to compare the rate of deep surgical site infection (SSI), as measured by the Centers for Disease Control and Prevention (CDC) definition, after surgery for a fracture of the hip between patients treated with standard dressings and those treated with incisional negative pressure wound therapy (iNPWT). Secondary objectives included determining the rate of recruitment and willingness to participate in the trial. Methods. The study was a two-arm multicentre randomized controlled feasibility trial that was embedded in the World Hip
Aims. A pilon fracture is a severe ankle joint injury caused by high-energy