Prosthetic joint infection (PJI) is a devastating complication following total joint arthroplasty. Non-contact induction heating of metal implants is a new and emerging treatment for PJI. However, there may be concerns for potential tissue necrosis. It is thought that segmental induction heating can be used to control the thermal dose and to limit collateral thermal injury to the bone and surrounding tissues. The purpose of this study was to determine the thermal dose, for commonly used metal implants in orthopaedic surgery, at various distances from the heating centre (HC). Commonly used metal orthopaedic implants (hip stem, intramedullary nail, and locking compression plate (LCP)) were heated segmentally using an induction heater. The thermal dose was expressed in cumulative equivalent minutes at 43°C (CEM43) and measured with a thermal camera at several different distances from the HC. A value of 16 CEM43 was used as the threshold for thermal damage in bone.Objectives
Methods
Severe acetabular bone loss and pelvic discontinuity (PD) present particular challenges in revision total hip arthroplasty. To deal with such complex situations, cup-cage reconstruction has emerged as an option for treating this situation. We aimed to examine our success in using this technique for these anatomical problems. We undertook a retrospective, single-centre series of 35 hips in 34 patients (seven male, 27 female) treated with a cup-cage construct using a trabecular metal shell in conjunction with a titanium cage, for severe acetabular bone loss between 2011 and 2015. The mean age at the time of surgery was 70 years (42 to 85) and all patients had an acetabular defect graded as Paprosky Type 2C through to 3B, with 24 hips (69%) having PD. The mean follow-up was 47 months (25 to 84).Aims
Patients and Methods
A single-centre prospective randomized trial was conducted to
investigate whether a less intensive follow-up protocol would not
be inferior to a conventional follow-up protocol, in terms of overall
survival, in patients who have undergone surgery for sarcoma of
the limb. Initial short-term results were published in 2014. The primary objective was to show non-inferiority of a chest
radiograph (CXR) group compared with a CT scan group, and of a less
frequent (six-monthly) group than a more frequent (three-monthly)
group, in two-by-two comparison. The primary outcome was overall
survival and the secondary outcome was a recurrence-free survival.
Five-year survival was compared between the CXR and CT scan groups
and between the three-monthly and six-monthly groups. Of 500 patients
who were enrolled, 476 were available for follow-up. Survival analyses
were performed on a per-protocol basis (n = 412).Aims
Patients and Methods
Recurrent infection following two-stage revision total hip arthroplasty
(THA) for prosthetic joint infection (PJI) is a devastating complication.
The purpose of this study was to report the survival of repeat two-stage
revision hip arthroplasty, describe complications, and identify
risk factors for failure. We retrospectively identified 19 hips (19 patients) that had
undergone repeat two-stage revision THA for infection between 2000
to 2013. There were seven female patients (37%) and the mean age
was 60 years (30 to 85). Survival free from revision was assessed
via Kaplan–Meier analysis. The patients were classified according
to the Musculoskeletal Infection Society (MSIS) system, and risk
factors for failure were identified. Mean follow-up was four years
(2 to 11).Aims
Patients and Methods
The aim of the study was to compare measures of the quality of
life (QOL) after resection of a chordoma of the mobile spine with
the national averages in the United States and to assess which factors
influenced the QOL, symptoms of anxiety and depression, and coping
with pain post-operatively in these patients. A total of 48 consecutive patients who underwent resection of
a primary or recurrent chordoma of the mobile spine between 2000
and 2015 were included. A total of 34 patients completed a survey
at least 12 months post-operatively. The primary outcome was the
EuroQol-5 Dimensions (EQ-5D-3L) questionnaire. Secondary outcomes were
the Patient-Reported Outcome Measurement Information System (PROMIS)
anxiety, depression and pain interference questionnaires. Data which
were recorded included the indication for surgery, the region of
the tumour, the number of levels resected, the status of the surgical
margins, re-operations, complications, neurological deficit, length
of stay in hospital and rate of re-admission.Aims
Patients and Methods
Researchers continue to seek easier ways to evaluate the quality of bone and screen for osteoporosis and osteopenia. Until recently, radiographic images of various parts of the body, except the distal femur, have been reappraised in the light of dual-energy X-ray absorptiometry (DXA) findings. The incidence of osteoporotic fractures around the knee joint in the elderly continues to increase. The aim of this study was to propose two new radiographic parameters of the distal femur for the assessment of bone quality. Anteroposterior radiographs of the knee and bone mineral density (BMD) and T-scores from DXA scans of 361 healthy patients were prospectively analyzed. The mean cortical bone thickness (CBTavg) and the distal femoral cortex index (DFCI) were the two parameters that were proposed and measured. Intra- and interobserver reliabilities were assessed. Correlations between the BMD and T-score and these parameters were investigated and their value in the diagnosis of osteoporosis and osteopenia was evaluated.Objectives
Methods
The posterior malleolus of the ankle is the object
of increasing attention, with considerable enthusiasm for CT scanning
and surgical fixation, as expressed in a recent annotation in Cite this article:
Although we often encounter patients with an aortic aneurysm
who also have diffuse idiopathic skeletal hyperostosis (DISH), there
are no reports to date of an association between these two conditions
and the pathogenesis of DISH remains unknown. This study therefore
evaluated the prevalence of DISH in patients with a thoracic aortic
aneurysm (AA). The medical records of 298 patients who underwent CT scans for
a diagnosis of an AA or following high-energy trauma were retrospectively
examined. A total of 204 patients underwent surgery for an AA and
94 had a high-energy injury and formed the non-AA group. The prevalence
of DISH was assessed on CT scans of the chest and abdomen and the
relationship between DISH and AA by comparison between the AA and
non-AA groups.Aims
Patients and Methods
We aimed to retrospectively assess the accuracy and safety of
CT navigated pedicle screws and to compare accuracy in the cervical
and thoracic spine (C2-T8) with (COMB) and without (POST) prior
anterior surgery (anterior cervical discectomy or corpectomy and
fusion with ventral plating: ACDF/ACCF). A total of 592 pedicle screws, which were used in 107 consecutively
operated patients (210 COMB, 382 POST), were analysed. The accuracy
of positioning was determined according to the classification of
Gertzbein and Robbins on post-operative CT scans.Aims
Patients and Methods
This paper describes the methodology, validation and reliability
of a new computer-assisted method which uses models of the patient’s
bones and the components to measure their migration and polyethylene
wear from radiographs after total hip arthroplasty (THA). Models of the patient’s acetabular and femoral component obtained
from the manufacturer and models of the patient’s pelvis and femur
built from a single computed tomography (CT) scan, are used by a
computer program to measure the migration of the components and
the penetration of the femoral head from anteroposterior and lateral radiographs
taken at follow-up visits. The program simulates the radiographic
setup and matches the position and orientation of the models to
outlines of the pelvis, the acetabular and femoral component, and
femur on radiographs. Changes in position and orientation reflect
the migration of the components and the penetration of the femoral
head. Validation was performed using radiographs of phantoms simulating
known migration and penetration, and the clinical feasibility of
measuring migration was assessed in two patients.Aims
Materials and Methods