Advertisement for orthosearch.org.uk
Results 301 - 320 of 749
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 2 | Pages 311 - 314
1 Mar 1988
Bowen C O'Brien B Gumley G

We investigated the feasibility in the dog of using transfers of the distal ulna into the radius either as growth plate replacements or as accessory growth plates in the diaphysis. Preliminary work determined the most satisfactory method of skeletal fixation. The experimental study showed that transfers used as growth plate replacements grew at almost normal rates, uniting with the recipient bone in a mean of 7.1 weeks. Transfers into the diaphysis initially nearly doubled the growth rate of the radius, although in the long-term results were unsatisfactory, because of fracture of the graft after a mean period of 8.2 weeks


Bone & Joint 360
Vol. 9, Issue 1 | Pages 21 - 24
1 Feb 2020


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 2 | Pages 196 - 201
1 Feb 2010
Hallan G Dybvik E Furnes O Havelin LI

The Norwegian Arthroplasty Register has shown that several designs of uncemented femoral stems give good or excellent survivorship. The overall findings for uncemented total hip replacement however, have been disappointing because of poor results with the use of metal-backed acetabular components. In this study, we exclusively investigated the medium-to long-term performance of primary uncemented metal-backed acetabular components. A total of 9113 primary uncemented acetabular components were implanted in 7937 patients between 1987 and 2007. These were included in a prospective, population-based observational study. All the implants were modular and metal-backed with ultra-high-molecular-weight polyethylene liners. The femoral heads were made of stainless steel, cobalt-chrome (CoCr) alloy or alumina ceramic. In all, seven different designs of acetabular component were evaluated by the Kaplan-Meier survivorship method and Cox regression analysis. Most acetabular components performed well up to seven years. When the endpoint was revision of the acetabular component because of aseptic loosening, the survival ranged between 87% and 100% at ten years. However, when the endpoint was revision for any reason, the survival estimates were 81% to 92% for the same implants at ten years. Aseptic loosening, wear, osteolysis and dislocation were the main reasons for the relatively poor overall performance of the acetabular components. Prostheses with alumina heads performed slightly better than those with stainless steel or CoCr alloy in subgroups. Whereas most acetabular components performed well at seven years, the survivorship declined with longer follow-up. Fixation was generally good. None of the metal-backed uncemented acetabular components with ultra-high-molecular-weight polyethylene liners in our study had satisfactory long-term results because of high rates of wear, osteolysis, aseptic loosening and dislocation


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 5 | Pages 682 - 687
1 Jul 2004
Bäthis H Perlick L Tingart M Lüring C Zurakowski D Grifka J

Restoration of neutral alignment of the leg is an important factor affecting the long-term results of total knee arthroplasty (TKA). Recent developments in computer-assisted surgery have focused on systems for improving TKA. In a prospective study two groups of 80 patients undergoing TKA had operations using either a computer-assisted navigation system or a conventional technique. Alignment of the leg and the orientation of components were determined on post-operative long-leg coronal and lateral films. The mechanical axis of the leg was significantly better in the computer-assisted group (96%, within ±3° varus/valgus) compared with the conventional group (78%, within ±3° varus/valgus). The coronal alignment of the femoral component was also more accurate in the computer-assisted group. Computer-assisted TKA gives a better correction of alignment of the leg and orientation of the components compared with the conventional technique. Potential benefits in the long-term outcome and functional improvement require further investigation


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 1 | Pages 3 - 6
1 Jan 1991
Cordes S Dickens D Cole W

The long-term results following the correction of coxa vara by Pauwels' Y-shaped intertrochanteric osteotomy have been evaluated in 14 children. Ten of the children had unilateral hip disease and were otherwise normal while four had bilateral hip disease due to generalised skeletal dysplasias. In each case, the growth plate was vertical, the femoral head was displaced inferiorly and there were abnormalities in the metaphysis of the femoral neck. The results indicate that this osteotomy provides lasting correction of the deformity, regardless of the cause, as long as the inclination of the growth plate is corrected to 40 degrees or less and adequate support is provided for the metaphyseal defect and the displaced femoral head


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1158 - 1163
1 Sep 2006
Tai CC Cross MJ

We carried out a prospective study of 118 hydroxyapatite-coated, cementless total knee replacements in patients who were ≤ 55 years of age and who had primary (92; 78%) or post-traumatic (26; 22%) osteoarthritis. The mean period of follow-up was 7.9 years (5 to 12.5). The Knee Society clinical scores improved from a pre-operative mean of 98 (0 to 137) to a mean of 185 (135 to 200) at five years, and 173 (137 to 200) at ten years. There were two revisions of the tibial component because of aseptic loosening, and one case of polyethylene wear requiring further surgery. There was no osteolysis or progressive radiological loosening of any other component. At 12 years, the overall rate of implant survival was 97.5% (excluding exchange of spacer) and 92.1% (including exchange of spacer). Cementless total knee replacement can achieve excellent long-term results in young, active patients with osteoarthritis. In contrast to total hip replacement, polyethylene wear, osteolysis and loosening of the prosthesis were not major problems for these patients, although it is possible that this observation could change with longer periods of follow-up


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 969 - 974
1 Nov 1999
Ito H Kaneda K Matsuno T

We present the long-term results of simple varus intertrochanteric osteotomy for osteonecrosis of the femoral head. We followed 26 hips in 20 patients, with a mean age at the time of surgery of 36 years, for a mean of 12.5 years. The mean varus angulation was 23°. The outcome in 19 of the hips (73%) was good or excellent; seven (27%) had a fair or poor result, with four needing some form of prosthetic arthroplasty. Simple varus intertrochanteric osteotomy is indicated, even if the extent of the capital infarct comprises more than 50% of the diameter of maximum radial distance from the circumference, provided that after operation the medial necrotic lesion measures less than two-thirds of the weight-bearing area, and the superolateral bone is normal


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 513 - 518
1 Apr 2020
Hershkovich O D’Souza A Rushton PRP Onosi IS Yoon WW Grevitt MP

Aims

Significant correction of an adolescent idiopathic scoliosis in the coronal plane through a posterior approach is associated with hypokyphosis. Factors such as the magnitude of the preoperative coronal curve, the use of hooks, number of levels fused, preoperative kyphosis, screw density, and rod type have all been implicated. Maintaining the normal thoracic kyphosis is important as hypokyphosis is associated with proximal junctional failure (PJF) and early onset degeneration of the spine. The aim of this study was to determine if coronal correction per se was the most relevant factor in generating hypokyphosis.

Methods

A total of 95 patients (87% female) with a median age of 14 years were included in our study. Pre- and postoperative radiographs were measured and the operative data including upper instrumented vertebra (UIV), lower instrumented vertebra (LIV), metal density, and thoracic flexibility noted. Further analysis of the post-surgical coronal outcome (group 1 < 60% correction and group 2 ≥ 60%) were studied for their association with the postoperative kyphosis in the sagittal plane using univariate and multivariate logistic regression.


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 3 | Pages 282 - 285
1 Jun 1982
Muirhead-Allwood W Catterall A

Eighty-four children suffering from Perthes' disease are reviewed. The policy of management for these patients was one by which 55 per cent of the cases had no active treatment and the remainder were treated by operation. Results of the series show an improvement over a previously reported series of untreated controls, particularly where clinical management had been possible throughout the disease process. The importance of early definitive treatment for Group 4 cases is stressed. It is concluded that in the early stages where "head-at-risk" signs are not present, treatment may be conservative. Should these signs develop later the long-term result is not prejudiced if operative treatment is undertaken promptly


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 5 | Pages 737 - 742
1 Jul 2004
Bourelle S Cottalorda J Gautheron V Chavrier Y

Of 23 children (35 feet) with cerebral palsy who had undergone a Grice extra-articular subtalar arthrodesis for a valgus hindfoot between 1976 and 1981, we reviewed 17 (26 feet), at a mean of 20 years (17 years 3 months to 22 years 4 months) after operation. Seven were quadriplegic, eight spastic diplegic, and two hemiplegic. They were all able to walk at the time of operation. Thirteen patients (20 feet) were pleased with the Grice procedure, 13 had no pain and 15 (23 feet) were still able to walk. The clinical results were satisfactory for most feet. Radiography showed that the results had been maintained over time but 14 feet developed a mean ankle valgus of 11° (6 to 18) with a compensatory hindfoot varus in 12 feet. No deformity of the talus or arthritis of adjacent joints was noted. The Grice procedure gives good long-term results in children with cerebral palsy


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 198 - 204
1 Feb 2020
Perlbach R Palm L Mohaddes M Ivarsson I Schilcher J

Aims

This single-centre observational study aimed to describe the results of extensive bone impaction grafting of the whole acetabular cavity in combination with an uncemented component in acetabular revisions performed in a standardized manner since 1993.

Methods

Between 1993 and 2013, 370 patients with a median age of 72 years (interquartile range (IQR) 63 to 79 years) underwent acetabular revision surgery. Of these, 229 were more than ten years following surgery and 137 were more than 15 years. All revisions were performed with extensive use of morcellized allograft firmly impacted into the entire acetabular cavity, followed by insertion of an uncemented component with supplementary screw fixation. All types of reoperation were captured using review of radiographs and medical charts, combined with data from the local surgical register and the Swedish Hip Arthroplasty Register.


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 5 | Pages 711 - 715
1 Sep 1992
Berry D Muller M

Revision hip arthroplasty in patients with massive acetabular bone deficiency has generally given poor long-term results. We report the use of an 'anti-protrusio cage', secured to the ischium and ilium, which bridges areas of acetabular bone loss, provides support for the acetabular socket, and allows pelvic bone grafting in an environment protected from excessive stress. Forty-two failed hip arthroplasties with massive acetabular bone loss were revised with the Burch-Schneider anti-protrusio cage and evaluated after two to 11 years (mean five years). There was failure due to sepsis in five hips (12%) and aseptic loosening in five (12%); the remaining 32 hips (76%) showed no evidence of acetabular component failure or loosening


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 3 | Pages 507 - 509
1 May 1990
van der Ham A Hackeng C Yo T

We treated 249 patients for ingrowing toenails in a prospective randomised study which compared wedge excision with segmental phenol cauterisation. Follow-up of 97% was at a minimum of 14 months. The analgesic requirement was significantly lower after phenol cauterisation (p less than 0.001), and significantly fewer patients needed to miss school or work (p = 0.001). Recurrence of ingrowth was seen in 16% after wedge excision and 9.6% after phenol cauterisation (not significant), but re-operation was significantly less frequent after phenol (p less than 0.01). Phenol cauterisation gives better short-term and long-term results than wedge resection


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 172 - 176
1 Mar 2004
Glyn-Jones S Gill HS McLardy-Smith P Murray DW

The Birmingham hip resurfacing (BHR) arthroplasty is a metal-on-metal prosthesis for which no medium- or long-term results have been published. Despite this, it is increasing in popularity as an alternative to stemmed prostheses for younger patients. Since the fixation of the socket is conventional, the major concern is long-term failure of the femoral component. This can be predicted by the use of roentgen stereophotogrammetric analysis (RSA). We have therefore undertaken such a study of the BHR femoral component over a period of two years. Twenty patients (22 hips) underwent a standard BHR procedure. Migration of the femoral component was measured by RSA at intervals of three, six, 12 and 24 months. At 24 months the total three-dimensional migration of the head was 0.2 mm. This was not statistically significant. Previous studies have shown that implants which loosen quickly have rapid early migration. Our results therefore suggest that the BHR femoral component is an inherently stable device which is likely to perform well in the long term


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 1 | Pages 78 - 84
1 Jan 1988
Saito S Ohzono K Ono K

We have reviewed 54 hips in 46 patients from 2 to 14 years after a joint-preserving operation for idiopathic avascular necrosis of the femoral head. The choice between core decompression (17 hips), bone grafting (18), rotation osteotomy (15) or varus osteotomy (4) was determined by the stage and location of the area of necrosis. The overall success rate was unexpectedly low at 60%. Core decompression and bone grafting by our techniques gave poor long-term results, but those of rotation or varus osteotomies, performed with care for the correct indications, were better. The indications for each procedure are discussed: osteotomy is best when the area of necrosis is shallow and localised in the medial or anterior portion of the femoral head


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 5 | Pages 647 - 652
1 Jul 2002
Nishimatsu H Iida H Kawanabe K Tamura J Nakamura T

We evaluated the long-term results of a modified Spitzy shelf operation for secondary osteoarthritis in 119 hips with a mean follow-up of 23.8 years. The mean age of the patients at the time of surgery was 25 years. Preoperative osteoarthritic change, the age at operation and shelf height were important factors in determining the outcome. Of the 61 hips in the pre-stage (three) and the initial stage (58) of osteoarthritis, 53 (87%) had good results, compared with only 30 (51%) of 58 hips with advanced osteoarthritis. Of the latter, 72% of those aged less than 25 years had good results compared with only 40% of patients aged over 25 years. The shelf height in the group with good results was significantly lower than in those with poor results. This operation is a safe procedure and indicated for acetabular dysplasia or subluxation of the hip with early osteoarthritic change in patients aged less than 25 years


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 1 | Pages 60 - 63
1 Jan 1995
Kakiuchi M

A combined open and percutaneous operative technique has been devised for repair of tendo Achillis. This minimises postoperative scarring. We compared the long-term results of 12 patients treated by this method with the results of 10 who had undergone an open repair. The combined open and percutaneous repair gave significantly better relief of symptoms during everyday activities (p < 0.05), better single-limb hopping (p < 0.02) and a greater chance of returning to sport (p < 0.01). There were no significant differences between the two treatments as regards to active range of ankle motion, calf circumference or the ability to stand on tiptoe. The new technique gave better cosmetic results


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 1 | Pages 49 - 52
1 Jan 1990
Jensen D Rude C Duus B Bjerg-Nielsen A

We evaluated the long-term results of 109 tibial plateau fractures, 61 treated by skeletal traction and early knee movement and 48 treated by surgery, at an average follow-up of 70 months. The functional results were much the same, though meniscectomy had been performed in almost half of the surgical patients. Time in bed and duration of hospital stay were clearly shorter after surgery (p less than 0.0001). We concluded that conservative management is a valid alternative to surgery, but should probably be reserved for cases where operation is undesirable. Future studies should compare surgery without meniscectomy and conservative treatment using cast braces to reduce the time in traction


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 5 | Pages 772 - 776
1 Nov 1988
Kannus P Jarvinen M

We have reviewed 32 patients who sustained a substantial knee ligament injury during adolescence when their knee epiphyses were open. They were all treated non-operatively and re-examined and evaluated in detail after an average of eight years. There were 25 Grade II partial tears and seven Grade III complete tears. After Grade II injuries the functional results were excellent or good, though static instability had not improved from the initial post-traumatic examination. The long-term results of Grade III injuries were poor, because of chronic functional instability, with continuous symptoms and some post-traumatic osteoarthritis. The results of non-operative treatment for Grade III ligament injuries were not acceptable


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 3 | Pages 361 - 363
1 Apr 2002
Jennings AG Sefton GK

We report the long-term results of the surgical treatment of chronic rupture of tendo Achillis using polyester tape. This requires minimal postoperative splintage and allows early mobilisation and a prompt return to work and sport. We reviewed 16 patients (10 women and 6 men) at a mean period of three years after surgery. The median time from injury to operation was 16.8 months (3.9 months to 13 years), and the median age of the patients was 52 years (27 to 78). The median time to full weight-bearing was 40 days and the median time for return to sport was 18 weeks (5.4 to 32). One patient required further surgery and one had numbness along the distribution of the sural nerve. After surgery only two patients had increased dorsiflexion of the ankle compared with the uninjured side. There were no cases of rerupture. We recommend this technique for the treatment of chronic rupture of tendo Achillis