Advertisement for orthosearch.org.uk
Results 281 - 300 of 2456
Results per page:
The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1640 - 1646
1 Dec 2018
Medellin MR Fujiwara T Clark R Jeys LM

Aims. The aim of this study was to describe, analyze, and compare the survival, functional outcome, and complications of minimally invasive (MI) and non-invasive (NI) lengthening total femoral prostheses. Patients and Methods. A total of 24 lengthening total femoral prostheses, 11 MI and 13 NI, were implanted between 1991 and 2016. The characteristics, complications, and functional results were recorded. There were ten female patients and ten male patients. Their mean age at the time of surgery was 11 years (2 to 41). The mean follow-up was 13.2 years (seven months to 29.25 years). A survival analysis was performed, and the failures were classified according to the Modified Henderson System. Results. The overall implant survival was 79% at five, ten, and 20 years for MI prostheses, and 84% at five years and 70% at ten years for NI prostheses. At the final follow-up, 13 prostheses did not require further surgery. The overall complication rate was 46%. The mean revision-free implant survival for MI and NI prostheses was 59 months and 49 months, respectively. There were no statistically significant differences in the overall implant survival, revision-free survival, or the distribution of complications between the two types of prosthesis. Infection rates were also comparable in the groups (9% vs 7%; p = 0.902). The rate of leg-length discrepancy was 54% in MI prostheses and 23% in NI prostheses. In those with a MI prosthesis, there was a smaller mean range of movement of the knee (0° to 62° vs 0° to 83°; p = 0.047), the flexion contracture took a longer mean time to resolve after lengthening (3.3 months vs 1.07 months; p < 0.001) and there was a lower mean Musculoskeletal Tumor Society (MSTS) score (24.7 vs 27; p = 0.295). Conclusion. The survival and complications of MI and NI lengthening total femoral prostheses are comparable. However, patients with NI prosthesis have more accurate correction of leg-length discrepancy, a better range of movement of the knee and an improved overall function


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1557 - 1562
1 Dec 2019
Tillman R Tsuda Y Puthiya Veettil M Young PS Sree D Fujiwara T Abudu A

Aims. The aim of this study was to present the long-term surgical outcomes, complications, implant survival, and causes of implant failure in patients treated with the modified Harrington procedure using antegrade large diameter pins. Patients and Methods. A cohort of 50 consecutive patients who underwent the modified Harrington procedure for periacetabular metastasis or haematological malignancy between January 1996 and April 2018 were studied. The median follow-up time for all survivors was 3.2 years (interquartile range 0.9 to 7.6 years). Results. The five-year overall survival rate was 33% for all the patients. However, implant survival rates were 100% and 46% at five and ten years, respectively. Eight patients survived beyond five years. There was no immediate perioperative mortality or complications. A total of 15 late complications occurred in 11 patients (22%). Five patients (10%) required further surgery to treat complications. The most frequent complication was pin breakage without evidence of acetabular loosening (6%). Two patients (4%) underwent revision for aseptic loosening at 6.5 and 8.9 years after surgery. Ambulatory status and pain level were improved in 83% and 89%, respectively. Conclusion. The modified Harrington procedure for acetabular destruction has low complication rates, good functional outcome, and improved pain relief in selected patients. Cite this article: Bone Joint J 2019;101-B:1557–1562


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1392 - 1398
1 Oct 2018
Willeumier JJ van de Sande MAJ van der Wal RJP Dijkstra PDS

Aims. The aim of this study was to assess the current trends in the estimation of survival and the preferred forms of treatment of pathological fractures among national and international general and oncological orthopaedic surgeons, and to explore whether improvements in the management of these patients could be identified in this way. Materials and Methods. All members of the Dutch Orthopaedic Society (DOS) and the European Musculoskeletal Oncology Society (EMSOS) were invited to complete a web-based questionnaire containing 12 cases. Results. A total of 96 of 948 members of the DOS (10.1%; groups 1 and 2) and 33 of 182 members of the EMSOS (18%; group 3) replied. The estimation of survival was accurate by more than 50% of all three groups, if the expected survival was short (< 3 months) or long (> 12 months). General orthopaedic surgeons preferred using an intramedullary nail for fractures of the humerus and femur, irrespective of the expected survival or the origin of primary tumour or the location of the fracture. Oncological orthopaedic surgeons recommended prosthetic reconstruction in patients with a long expected survival. Conclusion. Identifying patients who require centralized care, as opposed to those who can be adequately treated in a regional centre, can improve the management of patients with pathological fractures. This differentiation should be based on the expected survival, the type and extent of the tumour, and the location of the fracture. Cite this article: Bone Joint J 2018;100-B:1392–8


The Bone & Joint Journal
Vol. 102-B, Issue 8 | Pages 1088 - 1094
1 Aug 2020
Fujiwara T Tsuda Y Le Nail L Evans S Gregory J Tillman R Abudu A

Aims. The existing clinical guidelines do not describe a clear indication for adjuvant radiotherapy (RT) in the treatment of superficial soft tissue sarcomas (STSs). We aimed to determine the efficacy of adjuvant RT for superficial STSs. Methods. We retrospectively studied 304 patients with superficial STS of the limbs and trunk who underwent surgical resection at a tertiary sarcoma centre. The efficacy of RT was investigated according to the tumour size and grade: group 1, ≤ 5 cm, low grade; group 2, ≤ 5cm, high grade; group 3, > 5 cm, low grade; group 4, > 5 cm, high grade. Results. The five- and ten-year local recurrence-free survival (LRFS) for all patients was 88% and 81%, respectively. While the efficacy of adjuvant RT was not proven in local control of all patients (five-year LRFS; RT+, 90% versus RT-, 83%; p = 0.074), the LRFS was significantly improved by adjuvant RT in group 2 (five-year LRFS; RT+, 96% versus RT-, 82%; p = 0.019), and group 4 (five-year LRFS; RT+, 87% versus RT-, 73%; p = 0.027). In groups 2 and 4, adjuvant RT significantly reduced the LR risk if the resection margin was clear but less than 5 mm; the LR rate was 7% with adjuvant RT compared with 26% with surgery alone (p = 0.003). There was no statistical relationship with the use of adjuvant RT and survival in every group. Conclusion. Adjuvant RT reduces the risk of local recurrence in patients with superficial high-grade STS regardless of tumour size, especially when resection margin is less than 5 mm. Cite this article: Bone Joint J 2020;102-B(8):1088–1094


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 90 - 101
1 Jan 2020
Davis ET Pagkalos J Kopjar B

Aims. The aim of this study was to identify the effect of the manufacturing characteristics of polyethylene acetabular liners on the survival of cementless and hybrid total hip arthroplasty (THA). Methods. Prospective cohort study using linked National Joint Registry (NJR) and manufacturer data. The primary endpoint was revision for aseptic loosening. Cox proportional hazard regression was the primary analytical approach. Manufacturing variables included resin type, crosslinking radiation dose, terminal sterilization method, terminal sterilization radiation dose, stabilization treatment, total radiation dose, packaging, and face asymmetry. Total radiation dose was further divided into G1 (no radiation), G2 (> 0 Mrad to < 5 Mrad), G3 (≥ 5 Mrad to < 10 Mrad), and G4 (≥ 10 Mrad). Results. A total of 5,329 THAs were revised, 1,290 of which were due to aseptic loosening. Total radiation dose, face asymmetry, and stabilization treatments were found to significantly affect implant survival. G1 had the highest revision risk for any reason and for aseptic loosening and G3 and G4 the lowest. Compared with G1, the adjusted hazard ratio for G2 was 0.74 (95% confidence interval (CI) 0.64 to 0.86), G3 was 0.36 (95% CI 0.30 to 0.43), and G4 was 0.38 (95% CI 0.31 to 0.47). The cumulative incidence of revision for aseptic loosening at 12 years was 0.52 and 0.54 per 100 THAs for G3 and G4, respectively, compared with 1.95 per 100 THAs in G1. Asymmetrical liners had a lower revision risk due to aseptic loosening and reasons other than aseptic loosening compared with symmetric (flat) liners. In G3 and G4, stabilization with vitamin E and heating above melting point performed best. Conclusion. Polyethylene liners with a total radiation dose of ≥ 5 Mrad, an asymmetrical liner face, and stabilization with heating above the melting point demonstrate best survival. Cite this article: Bone Joint J 2020;102-B(1):90–101


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 96 - 103
1 Jan 2019
Colo E Leenders LAM Rijnen WHC Schreurs BW Hannink G

Aims. The aim of this study was to analyze the effect of a lateral rim mesh on the survival of primary total hip arthroplasty (THA) in young patients, aged 50 years or younger. Patients and Methods. We compared a study group of 235 patients (257 hips) who received a primary THA with the use of impaction bone grafting (IBG) with an additional lateral rim mesh with a group of 306 patients (343 hips) who received IBG in the absence of a lateral rim mesh during the same period from 1988 to 2015. In the mesh group, there were 74 male and 183 female patients, with a mean age of 35 years (13 to 50). In the no-mesh group, there were 173 male and 170 female patients, with a mean age of 38 years (12.6 to 50). Cox regression analyses were performed to study the effect of a lateral rim mesh on acetabular component survival. Kaplan–Meier analyses with 95% confidence intervals (CIs) were performed to estimate the survival of the acetabular implant. Results. The hazard ratio for the use of lateral rim mesh, adjusted for potential confounders, for acetabular revision for any reason was 0.50 (95% CI 0.13 to 1.93; p = 0.31) and for acetabular revision for aseptic loosening was 0.29 (95% CI 0.020 to 4.04; p = 0.35). The Kaplan–Meier analysis showed a ten-year survival for aseptic loosening of the acetabular of 98% (95% CI 95 to 100, n = 65 at risk) in the mesh group and 94% (89 to 98, n = 76 at risk) in the no-mesh group. The 15-year survival for aseptic acetabular loosening was 90% (81 to 100, n = 35 at risk) in the mesh group and 85% (77 to 94, n = 45 at risk) in the no-mesh group (p = 0.23). Conclusion. This study shows that the use of a lateral rim mesh in primary THA in young patients is not associated with a higher risk of revision of the acetabular component. Therefore, we consider a lateral rim mesh combined with IBG to be effective in reconstructing segmental acetabular defects in primary THA


The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1669 - 1677
1 Nov 2021
Divecha HM O'Neill TW Lunt M Board TN

Aims. To determine if primary cemented acetabular component geometry (long posterior wall (LPW), hooded, or offset reorientating) influences the risk of revision total hip arthroplasty (THA) for instability or loosening. Methods. The National Joint Registry (NJR) dataset was analyzed for primary THAs performed between 2003 and 2017. A cohort of 224,874 cemented acetabular components were included. The effect of acetabular component geometry on the risk of revision for instability or for loosening was investigated using log-binomial regression adjusting for age, sex, American Society of Anesthesiologists grade, indication, side, institution type, operating surgeon grade, surgical approach, polyethylene crosslinking, and prosthetic head size. A competing risk survival analysis was performed with the competing risks being revision for other indications or death. Results. The distribution of acetabular component geometries was: LPW 81.2%; hooded 18.7%; and offset reorientating 0.1%. There were 3,313 (1.5%) revision THAs performed, of which 815 (0.4%) were for instability and 838 (0.4%) were for loosening. Compared to the LPW group, the adjusted subhazard ratio of revision for instability in the hooded group was 2.31 (p < 0.001) and 4.12 (p = 0.047) in the offset reorientating group. Likewise, the subhazard ratio of revision for loosening was 2.65 (p < 0.001) in the hooded group and 13.61 (p < 0.001) in the offset reorientating group. A time-varying subhazard ratio of revision for instability (hooded vs LPW) was found, being greatest within the first three months. Conclusion. This registry-based study confirms a significantly higher risk of revision after cemented THA for instability and for loosening when a hooded or offset reorientating acetabular component is used, compared to a LPW component. Further research is required to clarify if certain patients benefit from the use of hooded or offset reorientating components, but we recommend caution when using such components in routine clinical practice. Cite this article: Bone Joint J 2021;103-B(11):1669–1677


Bone & Joint Research
Vol. 9, Issue 9 | Pages 578 - 586
1 Sep 2020
Ma M Liang X Wang X Zhang L Cheng S Guo X Zhang F Wen Y

Aims. Kashin-Beck disease (KBD) is a kind of chronic osteochondropathy, thought to be caused by environmental risk factors such as T-2 toxin. However, the exact aetiology of KBD remains unclear. In this study, we explored the functional relevance and biological mechanism of cartilage oligosaccharide matrix protein (COMP) in the articular cartilage damage of KBD. Methods. The articular cartilage specimens were collected from five KBD patients and five control subjects for cell culture. The messenger RNA (mRNA) and protein expression levels were detected by quantitative reverse transcription PCR (qRT-PCR) and western blot. The survival rate of C28/I2 chondrocyte cell line was detected by MTT assay after T-2 toxin intervention. The cell viability and mRNA expression levels of apoptosis related genes between COMP-overexpression groups and control groups were examined after cell transfection. Results. The mRNA and protein expression levels of COMP were significantly lower in KBD chondrocytes than control chondrocytes. After the T-2 toxin intervention, the COMP mRNA expression of C28/I2 chondrocyte reduced and the protein level of COMP in three intervention groups was significantly lower than in the control group. MTT assay showed that the survival rate of COMP overexpression KBD chondrocytes were notably higher than in the blank control group. The mRNA expression levels of Survivin, SOX9, Caspase-3, and type II collagen were also significantly different among COMP overexpression, negative control, and blank control groups. Conclusion. Our study results confirmed the functional relevance of COMP with KBD. COMP may play an important role in the excessive chondrocytes apoptosis of KBD patients. Cite this article: Bone Joint Res 2020;9(9):578–586


The Bone & Joint Journal
Vol. 102-B, Issue 7 Supple B | Pages 105 - 111
1 Jul 2020
Engh, Jr. CA McAsey CJ Cororaton AD Ho H Hopper, Jr. RH

Aims. The purpose of this study is to examine six types of bearing surfaces implanted at a single institution over three decades to determine whether the reasons for revision vary among the groups and how long it takes to identify differences in survival. Methods. We considered six cohorts that included a total of 1,707 primary hips done between 1982 and 2010. These included 223 conventional polyethylene sterilized with γ irradiation in air (CPE-GA), 114 conventional polyethylene sterilized with gas plasma (CPE-GP), 116 crosslinked polyethylene (XLPE), 1,083 metal-on-metal (MOM), 90 ceramic-on-ceramic (COC), and 81 surface arthroplasties (SAs). With the exception of the COC, all other groups used cobalt-chromium (CoCr) femoral heads. The mean follow-up was 10 (0.008 to 35) years. Descriptive statistics with revisions per 100 component years (re/100 yr) and survival analysis with revision for any reason as the endpoint were used to compare bearing surfaces. Results. XLPE liners demonstrated a lower cumulative incidence of revision at 15 years compared to the CPE-GA and CPE-GP groups owing to the absence of wear-related revisions (4% for XLPE vs 18%, p = 0.02, and 15%, p = 0.003, respectively). Revisions for adverse local tissue reactions occurred exclusively among the MOM (0.8 re/100 year) and SA groups (0.1 re/100 year). The revision rate for instability was lower among hips with 36 mm and larger head sizes compared to smaller head sizes (0.2% vs 2%, p < 0.001). Conclusion. The introduction of XLPE has eliminated wear-related revisions through 15-year follow-up compared to CPE-GP and CPE-GA. Dislocation incidence has been reduced with the introduction of larger diameter heads but remains a persistent concern. The potential for adverse local tissue reactions with MOM requires continued follow-up. Cite this article: Bone Joint J 2020;102-B(7 Supple B):105–111


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1379 - 1384
1 Oct 2019
Park J Park S Lee C

Aims. This study aimed to evaluate the incidence and prognosis of patients with spinal metastasis as the initial manifestation of malignancy (SM-IMM). Patients and Methods. We retrospectively reviewed the electronic medical records of 338 patients who underwent surgical treatment for metastatic spinal disease. The enrolled patients were divided into two groups. The SM-IMM group included patients with no history of malignancy whose site of primary malignancy was diagnosed after the identification of spinal metastasis. The other group included patients with a history of treatment for primary malignancy who then developed spinal metastasis (SM-DTM). The incidence of SM-IMM by site of primary malignancy was calculated. The difference between prognoses after surgical treatment for SM-IMM and SM-DTM was established. Results. The median follow-up period was 11.5 months (interquartile range (IQR) 3.2 to 13.4) after surgical treatment. During the follow-up period, 264 patients died; 74 patients survived. The SM-IMM group consisted of 94 patients (27.8%). The site of primary malignancy in the SM-IMM group was lung in 35/103 patients (34.0%), liver in 8/45 patients (17.8%), kidney in 10/33 patients (30.3%), colorectum in 3/29 patients (10.3%), breast in 3/22 patients (13.6%), prostate in 3/10 patients (30%), thyroid in 4/8 patients (50%), and ‘other’ in 28/88 patients (31.8%). On Kaplan–Meier survival analysis, the SM-IMM group showed a significantly longer survival than the SM-DTM group (p = 0.013). The mean survival time was 23.0 months (95% confidence interval (CI) 15.5 to 30.5) in the SM-IMM group and 15.5 months (95% CI 11.8 to 19.2) in the SM-DTM group. Conclusion. Of the 338 enrolled patients who underwent surgical treatment for spinal metastasis, 94 patients (27.8%) underwent surgical treatment for SM-IMM. The SM-IMM group had an acceptable prognosis with surgical treatment. Cite this article: Bone Joint J 2019;101-B:1379–1384


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 116 - 122
1 Jun 2020
Bedard NA Cates RA Lewallen DG Sierra RJ Hanssen AD Berry DJ Abdel MP

Aims. Metaphyseal cones with cemented stems are frequently used in revision total knee arthroplasty (TKA). However, if the diaphysis has been previously violated, the resultant sclerotic canal can impair cemented stem fixation, which is vital for bone ingrowth into the cone, and long-term fixation. We report the outcomes of our solution to this problem, in which impaction grafting and a cemented stem in the diaphysis is combined with an uncemented metaphyseal cone, for revision TKA in patients with severely compromised bone. Methods. A metaphyseal cone was combined with diaphyseal impaction grafting and cemented stems for 35 revision TKAs. There were two patients with follow-up of less than two years who were excluded, leaving 33 procedures in 32 patients in the study. The mean age of the patients at the time of revision TKA was 67 years (32 to 87); 20 (60%) were male. Patients had undergone a mean of four (1 to 13) previous knee arthroplasty procedures. The indications for revision were aseptic loosening (80%) and two-stage reimplantation for prosthetic joint infection (PJI; 20%). The mean follow-up was four years (2 to 11). Results. Survival free from revision of the cone/impaction grafting construct due to aseptic loosening was 100% at five years. Survival free from any revision of the construct and free from any reoperation were 92% and 73% at five years, respectively. A total of six patients (six TKAs, 17%) required a further revision, four for infection or wound issues, and two for periprosthetic fracture. Radiologically, one unrevised TKA had evidence of loosening which was asymptomatic. In all unrevised TKAs the impacted diaphyseal bone graft appeared to be incorporated radiologically. Conclusion. When presented with a sclerotic diaphysis and substantial metaphyseal bone loss, this technique combining diaphyseal impaction grafting with a metaphyseal cone provided near universal success in relation to implant fixation. Moreover, radiographs revealed incorporation of the bone graft and biological fixation of the cone. While long-term follow-up will be important, this technique provides an excellent option for the management of complex revision TKAs. Cite this article: Bone Joint J 2020;102-B(6 Supple A):116–122


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 478 - 483
1 Apr 2019
Borg T Hernefalk B Hailer NP

Aims. Displaced, comminuted acetabular fractures in the elderly are increasingly common, but there is no consensus on whether they should be treated non-surgically, surgically with open reduction and internal fixation (ORIF), or with acute total hip arthroplasty (THA). A combination of ORIF and acute THA, an approach called ’combined hip procedure’ (CHP), has been advocated and our aim was to compare the outcome after CHP or ORIF alone. Patients and Methods. A total of 27 patients with similar acetabular fractures (severe acetabular impaction with or without concomitant femoral head injury) with a mean age of 72.2 years (50 to 89) were prospectively followed for a minimum of two years. In all, 14 were treated with ORIF alone and 13 were treated with a CHP. Hip joint and patient survival were estimated. Operating times, blood loss, radiological outcomes, and patient-reported outcomes were assessed. Results. No patient in the CHP group required further hip surgery, giving THA a survival rate of 100% (95% confidence interval (CI) 100 to 100) after three years, compared with 28.6% hip joint survival in the ORIF group (95% CI 12.5 to 65.4; p = 0.001). No dislocations or deep infections occurred in the CHP group. No patient died within the first year after index surgery, but patient survival was lower in the CHP group after three years. There were no relevant differences in patient-reported outcomes. Conclusion. The CHP confers a considerably reduced need of further surgery when compared with ORIF alone in elderly patients with complex acetabular fractures. These findings encourage both further use of, and larger prospective studies on, the CHP. Cite this article: Bone Joint J 2019;101-B:478–483


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 414 - 422
1 Apr 2020
Gwynne-Jones DP Gray AR

Aims. To compare long-term survival of all-cemented and hybrid total hip arthroplasty (THA) using the Exeter Universal stem. Methods. Details of 1,086 THAs performed between 1999 and 2005 using the Exeter stem and either a cemented (632) or uncemented acetabular component (454) were collected from local records and the New Zealand Joint Registry. A competing risks regression survival analysis was performed with death as the competing risk with adjustments made for age, sex, approach, and bearing. Results. There were 61 revisions (9.7%; 0.82 revisions/100 observed component years, (OCYs)) in the all-cemented group and 18 (4.0%; 0.30/100 OCYs) in the hybrid group. The cumulative incidence of revision at 18 years was 12.1% for cemented and 5.2% for hybrids. There was a significantly greater risk of revision for all-cemented compared with hybrids (unadjusted sub-hazard ratio (SHR) 2.44; p = 0.001), and of revision for loosening, wear, or osteolysis (unadjusted SHR 3.77; p < 0.001). After adjustment, the increased risk of all-cause revision did not reach significance at age 70 years and above. The advantage for revision for loosening, wear, and osteolysis remained at all ages. Conclusion. This study supports the use of uncemented acetabular fixation when used in combination with the Exeter stem with improved survivorship for revision for aseptic loosening, wear, and osteolysis at all ages and for all-cause revision in patients less than 70 years. Cite this article: Bone Joint J 2020;102-B(4):414–422


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 779 - 787
1 Jun 2020
Gupta S Griffin AM Gundle K Kafchinski L Zarnett O Ferguson PC Wunder J

Aims. Iliac wing (Type I) and iliosacral (Type I/IV) pelvic resections for a primary bone tumour create a large segmental defect in the pelvic ring. The management of this defect is controversial as the surgeon may choose to reconstruct it or not. When no reconstruction is undertaken, the residual ilium collapses back onto the remaining sacrum forming an iliosacral pseudarthrosis. The aim of this study was to evaluate the long-term oncological outcome, complications, and functional outcome after pelvic resection without reconstruction. Methods. Between 1989 and 2015, 32 patients underwent a Type I or Type I/IV pelvic resection without reconstruction for a primary bone tumour. There were 21 men and 11 women with a mean age of 35 years (15 to 85). The most common diagnosis was chondrosarcoma (50%, n = 16). Local recurrence-free, metastasis-free, and overall survival were assessed using the Kaplan-Meier method. Patient function was evaluated using the Musculoskeletal Tumour Society (MSTS) and Toronto Extremity Salvage Score (TESS). Results. At a mean follow-up of 159 months (1 to 207), 23 patients were alive without disease, one was alive with lung metastases, one was alive following local recurrence, four were dead of disease, and three had died from other causes. The overall ten-year survival was 77%. There was only one (3%) local recurrence, which occurred at 26 months. There were 18 complications in 17 patients; 13 wound healing complications/infections, three fractures, one pulmonary embolism, and one dislocation of the hip. Most complications occurred early. The mean functional scores were 21.1 (SD 8.1) for MSTS-87, 67.3 (SD 23.9) for MSTS-93 and 76.2 (SD 20.6) for TESS. Conclusion. Patients requiring Type I or Type I/IV pelvic resections can expect a good oncological outcome and a high rate of local control. Complications are generally acute in nature and are easily manageable. These patients achieved a good functional outcome without the need for bony reconstruction. Cite this article: Bone Joint J 2020;102-B(6):779–787


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 227 - 232
1 Feb 2019
Walker T Rutkowski L Innmann M Panzram B Herre J Gotterbarm T Aldinger PR Merle C

Aims. The treatment of patients with allergies to metal in total joint arthroplasty is an ongoing debate. Possibilities include the use of hypoallergenic prostheses, as well as the use of standard cobalt-chromium (CoCr) alloy. This non-designer study was performed to evaluate the clinical outcome and survival rates of unicondylar knee arthroplasty (UKA) using a standard CoCr alloy in patients reporting signs of a hypersensitivity to metal. Patients and Methods. A consecutive series of patients suitable for UKA were screened for symptoms of metal hypersensitivity by use of a questionnaire. A total of 82 patients out of 1737 patients suitable for medial UKA reporting cutaneous metal hypersensitivity to cobalt, chromium, or nickel were included into this study and prospectively evaluated to determine the functional outcome, possible signs of hypersensitivity, and short-term survivorship at a minimum follow-up of 1.5 years. Results. At a mean follow-up of three years (1.5 to 5.7), no local or systemic symptoms of hypersensitivity to metal were observed. One patient underwent revision surgery to a bicondylar prosthesis due to a tibial periprosthetic fracture resulting in a survival rate of 98.8% (95% confidence interval (CI) 91.7 to 99.8; number at risk, 28) at three years with the endpoint of revision for any reason and a survival rate of 97.6% (95% CI 90.6 to 99.3; number at risk, 29) for the endpoint of all reoperations. Clinical outcome was good to excellent with a mean Oxford Knee Score of 42.5 (. sd. 2.5; 37 to 48). Conclusion. This study is the first demonstrating clinical results and survival analysis of UKA using a CoCr alloy in patients with a history of metal hypersensitivity. Functional outcome and survivorship are on a high-level equivalent to those reported for UKA in patients without a history of metal hypersensitivity. No serious local or systemic symptoms of metal hypersensitivity could be detected, and no revision surgery was performed due to an adverse reaction to metal ions


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 47 - 54
1 Jan 2019
Clough T Bodo K Majeed H Davenport J Karski M

Aims. We report the long-term clinical and radiological outcomes of a consecutive series of 200 total ankle arthroplasties (TAAs, 184 patients) at a single centre using the Scandinavian Total Ankle Replacement (STAR) implants. Patients and Methods. Between November 1993 and February 2000, 200 consecutive STAR prostheses were implanted in 184 patients by a single surgeon. Demographic and clinical data were collected prospectively and the last available status was recorded for further survival analysis. All surviving patients underwent regular clinical and radiological review. Pain and function were assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot scoring system. The principal endpoint of the study was failure of the implant requiring revision of one or all of the components. Kaplan–Meier survival curves were generated with 95% confidence intervals and the rate of failure calculated for each year. Results. A total of 84 patients (87 ankles) were alive by the end of this study. Of the surviving 84 patients (87 ankles; rheumatoid arthritis (RA), n = 40; OA, n = 47), 45 were women and 39 were men, with a mean age of 54 years (18 to 72 years) at the time of surgery. A total of 32 implants failed (16%), requiring revision surgery. The mean time to revision was 80 months (2 to 257). The implant survival at 15.8 years, using revision as an endpoint, was 76.16% (95% confidence interval (CI) 64.41 to 87.91). We found a steady but low decrease in survival over the study period. The mean AOFAS score improved from 28 (10 to 52) preoperatively to 61 (20 to 90) at long-term follow-up. Conclusion. STAR prostheses in the United Kingdom have now been largely superseded by newer design TAAs, potentially with improved characteristics and surgical techniques. The long-term survivorship for the STAR prosthesis can provide a benchmark for these later designs of ankle arthroplasty


The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1157 - 1161
1 Sep 2018
Brown TS Fehring KA Ollivier M Mabry TM Hanssen AD Abdel MP

Aims. Recurrent infection following two-stage revision total hip arthroplasty (THA) for prosthetic joint infection (PJI) is a devastating complication. The purpose of this study was to report the survival of repeat two-stage revision hip arthroplasty, describe complications, and identify risk factors for failure. Patients and Methods. We retrospectively identified 19 hips (19 patients) that had undergone repeat two-stage revision THA for infection between 2000 to 2013. There were seven female patients (37%) and the mean age was 60 years (30 to 85). Survival free from revision was assessed via Kaplan–Meier analysis. The patients were classified according to the Musculoskeletal Infection Society (MSIS) system, and risk factors for failure were identified. Mean follow-up was four years (2 to 11). Results. Gram-positive bacteria were responsible for 16/17 (94%) of the re-infections where microbes were identified. Following the repeat two-stage exchange arthroplasty, survival free from any revision was 74% (95% confidence interval (CI) 56% to 96%, 14 at risk) at two years and 45% (95% CI 25% to 75%, five at risk) at five years. Failure to control infection resulted in re-operation or revision in 42%A of patients (8/19). Survival free from revision was not dependent on host grade. Conclusion. Re-infection after two-stage exchange hip arthroplasty for PJI presents a challenging scenario. Repeat two-stage exchange arthroplasty has a low survival free from revision at five years (45%) and a high rate of re-infection (42%). Cite this article: Bone Joint J 2018;100-B:1157–61


The Bone & Joint Journal
Vol. 103-B, Issue 6 | Pages 1070 - 1077
1 Jun 2021
Hipfl C Mooij W Perka C Hardt S Wassilew GI

Aims. The purpose of this study was to evaluate unexpected positive cultures in total hip arthroplasty (THA) revisions for presumed aseptic loosening, to assess the prevalence of low-grade infection using two definition criteria, and to analyze its impact on implant survival after revision. Methods. A total of 274 THA revisions performed for presumed aseptic loosening from 2012 to 2016 were reviewed. In addition to obtaining intraoperative tissue cultures from all patients, synovial and sonication fluid samples of the removed implant were obtained in 215 cases (79%) and 101 cases (37%), respectively. Histopathological analysis was performed in 250 cases (91%). Patients were classified as having low-grade infections according to institutional criteria and Musculoskeletal Infection Society (MSIS) International Consensus Meeting (ICM) 2013 criteria. Low-grade infections according to institutional criteria were treated with targeted antibiotics for six weeks postoperatively. Implant failure was defined as the need for re-revision resulting from periprosthetic joint infection (PJI) and aseptic reasons. The mean follow-up was 68 months (26 to 95). Results. Unexpected positive intraoperative samples were found in 77 revisions (28%). Low-grade infection was diagnosed in 36 cases (13%) using institutional criteria and in nine cases (3%) using MSIS ICM 2013 criteria. In all, 41 patients (15%) had single specimen growth of a low-virulent pathogen and were deemed contaminated. Coagulase-negative Staphylococcus and anaerobes were the most commonly isolated bacteria. Implant failure for PJI was higher in revisions with presumed contaminants (5/41, 12%) compared to those with low-grade infections (2/36, 6%) and those with negative samples (5/197, 3%) (p = 0.021). The rate of all-cause re-revision was similar in patients diagnosed with low-grade infections (5/36, 14%) and those with presumed contaminants (6/41, 15%) and negative samples (21/197, 11%) (p = 0.699). Conclusion. Our findings suggest that the presumption of culture contamination in aseptic revision hip arthroplasty may increase the detection of PJI. In this cohort, the presence of low-grade infection did not increase the risk of re-revision. Further studies are needed to assess the relevance of single specimen growth and the benefits of specific postoperative antibiotic regimens. Cite this article: Bone Joint J 2021;103-B(6):1070–1077


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1647 - 1654
1 Dec 2018
Shepherd KL Cool P Cribb G

Aims. The purpose of this study was to identify prognostic indicators of outcome at presentation to the orthopaedic surgeon, in patients with metastatic prostate cancer. Our aim was to use this information in a pragmatic, clinic-based approach so that surgical decision making could be optimized to benefit the patient in their remaining lifetime. Patients and Methods. A cohort analysis was undertaken of all patients with metastatic disease of the prostate who presented to a regional orthopaedic centre in the United Kingdom between 2003 and 2016. Biochemical data were collected in addition to disease and demographic data. These included: prostate-specific antigen (PSA) at orthopaedic presentation; haemoglobin (Hb); platelets (plt); alkaline phosphatase (ALP); albumin (Alb); and corrected calcium (CaC). Statistical analysis included Kaplan–Meier survival analysis, and a Cox proportional hazards model was fitted to the data. Results. From the departmental database, 137 episodes were identified in 136 patients with a median age at presentation of 72 years (interquartile range (IQR) 66 to 78). Most patients had stage IV disease (n = 98, 72%), and most did not undergo surgical intervention. At one-year follow-up, 50% of patients had died. Biomarkers found to be independently associated with poor survival were: low Hb, low Alb, relatively low PSA (< 30 mmol/l), and a raised ALP. Patients who needed surgical intervention had a poorer survival rate than patients who were managed nonoperatively. Conclusion. The study findings are important for orthopaedic clinical practice in the management of patients with metastatic prostate cancer. The interpretation of routine blood tests can help to predict survival in patients who present with orthopaedic manifestations of prostate cancer. A lower PSA is not necessarily a good prognostic sign. We believe that simple blood testing should be carried out routinely when assessing a patient, guiding potential surgical management and palliative care in the future


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 787 - 792
1 Jul 2019
Goto K Kuroda Y Kawai T Kawanabe K Matsuda S

Aims. In the 1990s, a bioactive bone cement (BABC) containing apatite-wollastonite glass-ceramic (AW-GC) powder and bisphenol-a-glycidyl methacrylate resin was developed at our hospital. In 1996, we used BABC to fix the acetabular component in primary total hip arthroplasty (THA) in 20 patients as part of a clinical trial. The purpose of this study was to investigate the long-term results of primary THA using BABC. Patients and Methods. A total of 20 patients (three men and 17 women) with a mean age of 57.4 years (40 to 71), a mean body weight of 52.3 kg (39 to 64), and a mean body mass index (BMI) of 23.0 kg/m. 2. (19.8 to 28.6) were evaluated clinically and radiologically. Survival analyses were undertaken, and wear analyses were carried out using a computer-aided method. Results. The mean follow-up was 17.6 years (1.5 to 21.1). Radiological loosening occurred in four sockets with aseptic loosening at a mean of 7.8 years (1.5 to 20.7). Kaplan–Meier survival analyses using revision of the acetabular component, radiological loosening of the acetabular component, and the worst-case scenario with revision of the acetabular component to include the two patients lost to follow-up as endpoints yielded survival rates of 94.7%, 84.4%, and 85.0% at ten years, and 70.0%, 84.4%, and 62.8% at 20 years, respectively. Wear analysis revealed a mean linear wear rate of 0.068 mm per year. Conclusion. The long-term results of primary THAs using BABC were unsatisfactory. Its brittle nature and poor handling properties need to be improved before it becomes an alternative method of fixing the acetabular component in cemented THA. Cite this article: Bone Joint J 2019;101-B:787–792