Prosthetic joint infection (PJI) is a devastating complication following total joint arthroplasty. Non-contact induction heating of metal implants is a new and emerging treatment for PJI. However, there may be concerns for potential tissue necrosis. It is thought that segmental induction heating can be used to control the thermal dose and to limit collateral thermal injury to the bone and surrounding tissues. The purpose of this study was to determine the thermal dose, for commonly used metal implants in orthopaedic surgery, at various distances from the heating centre (HC). Commonly used metal orthopaedic implants (hip stem, intramedullary nail, and locking compression plate (LCP)) were heated segmentally using an induction heater. The thermal dose was expressed in cumulative equivalent minutes at 43°C (CEM43) and measured with a thermal camera at several different distances from the HC. A value of 16 CEM43 was used as the threshold for thermal damage in bone.Objectives
Methods
Unicompartmental knee arthroplasty (UKA) is one surgical option for treating symptomatic medial osteoarthritis. Clinical studies have shown the functional benefits of UKA; however, the optimal alignment of the tibial component is still debated. The purpose of this study was to evaluate the effects of tibial coronal and sagittal plane alignment in UKA on knee kinematics and cruciate ligament tension, using a musculoskeletal computer simulation. The tibial component was first aligned perpendicular to the mechanical axis of the tibia, with a 7° posterior slope (basic model). Subsequently, coronal and sagittal plane alignments were changed in a simulation programme. Kinematics and cruciate ligament tensions were simulated during weight-bearing deep knee bend and gait motions. Translation was defined as the distance between the most medial and the most lateral femoral positions throughout the cycle.Objectives
Methods
The aims of this study were to establish whether composite fixation
(rail-plate) decreases fixator time and related problems in the
management of patients with infected nonunion of tibia with a segmental
defect, without compromising the anatomical and functional outcomes
achieved using the classical Ilizarov technique. We also wished
to study the acceptability of this technique using patient-based
objective criteria. Between January 2012 and January 2015, 14 consecutive patients
were treated for an infected nonunion of the tibia with a gap and
were included in the study. During stage one, a radical debridement
of bone and soft tissue was undertaken with the introduction of
an antibiotic-loaded cement spacer. At the second stage, the tibia
was stabilized using a long lateral locked plate and a six-pin monorail
fixator on its anteromedial surface. A corticotomy was performed
at the appropriate level. During the third stage, i.e. at the end
of the distraction phase, the transported fragment was aligned and
fixed to the plate with two to four screws. An iliac crest autograft
was added to the docking site and the fixator was removed. Functional
outcome was assessed using the Association for the Study and Application
of Methods of Ilizarov (ASAMI) criteria. Patient-reported outcomes
were assessed using the Musculoskeletal Tumor Society (MSTS) score.Aims
Patients and Methods
Anatomical atlases document classical safe corridors for the
placement of transosseous fine wires through the calcaneum during
circular frame external fixation. During this process, the posterior
tibial neurovascular bundle (PTNVB) is placed at risk, though this
has not been previously quantified. We describe a cadaveric study
to investigate a safe technique for posterolateral to anteromedial
fine wire insertion through the body of the calcaneum. A total of 20 embalmed cadaveric lower limbs were divided into
two groups. Wires were inserted using two possible insertion points
and at varying angles. In Group A, wires were inserted one-third
along a line between the point of the heel and the tip of the lateral
malleolus while in Group B, wires were inserted halfway along this
line. Standard dissection techniques identified the structures at
risk and the distance of wires from neurovascular structures was measured.
The results from 19 limbs were subject to analysis.Aims
Materials and Methods
The primary stability of the cementless Oxford Unicompartmental Knee Replacement (OUKR) relies on interference fit (or press fit). Insufficient interference may cause implant loosening, whilst excessive interference could cause bone damage and fracture. The aim of this study was to identify the optimal interference fit by measuring the force required to seat the tibial component of the cementless OUKR (push-in force) and the force required to remove the component (pull-out force). Six cementless OUKR tibial components were implanted in 12 new slots prepared on blocks of solid polyurethane foam (20 pounds per cubic foot (PCF), Sawbones, Malmo, Sweden) with a range of interference of 0.1 mm to 1.9 mm using a Dartec materials testing machine HC10 (Zwick Ltd, Herefordshire, United Kingdom) . The experiment was repeated with cellular polyurethane foam (15 PCF), which is a more porous analogue for trabecular bone.Objectives
Materials and Methods
The aim of this study was to compare the cost-effectiveness of
intramedullary nail fixation and ‘locking’ plate fixation in the
treatment of extra-articular fractures of the distal tibia. An economic evaluation was conducted from the perspective of
the United Kingdom National Health Service (NHS) and personal social
services (PSS), based on evidence from the Fixation of Distal Tibia
Fractures (UK FixDT) multicentre parallel trial. Data from 321 patients
were available for analysis. Costs were collected prospectively
over the 12-month follow-up period using trial case report forms
and participant-completed questionnaires. Cost-effectiveness was
reported in terms of incremental cost per quality adjusted life
year (QALY) gained, and net monetary benefit. Sensitivity analyses
were conducted to test the robustness of cost-effectiveness estimates.Aim
Patients and Methods
The aim of this study was to describe the technique of distraction
osteogenesis followed by arthrodesis using internal fixation to
manage complex conditions of the ankle, and to present the results
of this technique. Between 2008 and 2014, distraction osteogenesis followed by arthrodesis
using internal fixation was performed in 12 patients with complex
conditions of the ankle due to trauma or infection. There were eight
men and four women: their mean age was 35 years (23 to 51) at the
time of surgery. Bone healing and functional recovery were evaluated
according to the criteria described by Paley. Function was assessed
using the ankle-hindfoot scale of the American Orthopedic Foot and
Ankle Society (AOFAS).Aims
Patients and Methods
Opening wedge high tibial osteotomy (HTO) is an established surgical procedure for the treatment of early-stage knee arthritis. Other than infection, the majority of complications are related to mechanical factors – in particular, stimulation of healing at the osteotomy site. This study used finite element (FE) analysis to investigate the effect of plate design and bridging span on interfragmentary movement (IFM) and the influence of fracture healing on plate stress and potential failure. A 10° opening wedge HTO was created in a composite tibia. Imaging and strain gauge data were used to create and validate FE models. Models of an intact tibia and a tibia implanted with a custom HTO plate using two different bridging spans were validated against experimental data. Physiological muscle forces and different stages of osteotomy gap healing simulating up to six weeks postoperatively were then incorporated. Predictions of plate stress and IFM for the custom plate were compared against predictions for an industry standard plate (TomoFix).Objectives
Materials and Methods
This study reviews the use of a titanium mesh cage (TMC) as an
adjunct to intramedullary nail or plate reconstruction of an extra-articular
segmental long bone defect. A total of 17 patients (aged 17 to 61 years) treated for a segmental
long bone defect by nail or plate fixation and an adjunctive TMC
were included. The bone defects treated were in the tibia (nine),
femur (six), radius (one), and humerus (one). The mean length of
the segmental bone defect was 8.4 cm (2.2 to 13); the mean length
of the titanium mesh cage was 8.3 cm (2.6 to 13). The clinical and
radiological records of the patients were analyzed retrospectively.Aims
Patients and Methods
We treated 24 patients with nonunion of
1. The frequency of variable degrees of ischaemia of soft tissue in closed tibial and fibular shaft fractures is emphasised. 2. Two cases with ischaemia of calf musculature are described. 3. A follow-up study of 100 cases of closed
We report the results of a three-year study of bifocal fractures of the tibia and fibula, excluding segmental shaft fractures. In our whole series, these formed 4.7% of all
The surgical challenge with severe hindfoot injuries is one of technical feasibility, and whether the limb can be salvaged. There is an additional question of whether these injuries should be managed with limb salvage, or whether patients would achieve a greater quality of life with a transtibial amputation. This study aims to measure functional outcomes in military patients sustaining hindfoot fractures, and identify injury features associated with poor function. Follow-up was attempted in all United Kingdom military casualties sustaining hindfoot fractures. All respondents underwent short-form (SF)-12 scoring; those retaining their limb also completed the American Academy of Orthopaedic Surgeons Foot and Ankle (AAOS F&A) outcomes questionnaire. A multivariate regression analysis identified injury features associated with poor functional recovery.Objectives
Methods
1. The results of internal fixation are described in 470
The Fluid Lavage in Open Fracture Wounds (FLOW) trial was a multicentre,
blinded, randomized controlled trial that used a 2 × 3 factorial
design to evaluate the effect of irrigation solution (soap Participants completed the Short Form-12 (SF-12) and the EuroQol-5
Dimensions (EQ-5D) at baseline (pre-injury recall), at two and six
weeks, and at three, six, nine and 12-months post-fracture. We calculated
the Physical Component Score (PCS) and the Mental Component Score
(MCS) of the SF-12 and the EQ-5D utility score, conducted an analysis
using a multi-level generalized linear model, and compared differences
between the baseline and 12-month scores.Aims
Patients and Methods