Advertisement for orthosearch.org.uk
Results 281 - 300 of 2367
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 3 | Pages 433 - 437
1 May 1997
Antich-Adrover P Martí-Garin D Murias-Alvarez J Puente-Alonso C

We performed a prospective, randomised trial in 39 patients with open tibial fractures treated initially by external fixation to compare cast immobilisation (group A) and intramedullary nailing (group B) as a sequential protocol planned from the onset of treatment. The results showed that group B achieved faster union (p < 0.05) than group A with less malunion or shortening and a greater range of movement. Patients treated by intramedullary nailing required fewer radiographs and outpatient visits (p = 0.0015) and had a more predictable and rapid return to full function. We feel that these severe fractures are better treated by delayed intramedullary nailing and that this has an acceptable rate of complications


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 4 | Pages 650 - 655
1 Aug 1985
Goodship A Kenwright J

Although it has been well established that fracture healing is influenced by the mechanical environment, the optimal parameters have not yet been established. In two groups of sheep an experimental tibial diaphysial fracture was created, and stabilised using external skeletal fixation. In one group rigid fixation was maintained throughout fracture healing; in the other group controlled axial micromovement, with a loading regime known to be osteogenic in intact bones, was applied for a short period daily. A significant improvement in healing was associated with the application of controlled micromovement. Data from these experiments provide the basis for improving the conditions for fracture healing and may assist in the prevention of delayed union


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 11 | Pages 1563 - 1567
1 Nov 2010
Parmaksizoglu F Koprulu AS Unal MB Cansu E

We present the results of 13 patients who suffered severe injuries to the lower leg. Five sustained a traumatic amputation and eight a Gustilo-Anderson type IIIC open fracture. All were treated with debridement, acute shortening and stabilisation of the fracture and vascular reconstruction. Further treatment involved restoration of tibial length by callus distraction through the distal or proximal metaphysis, which was commenced soon after the soft tissues had healed (n = 8) or delayed until union of the fracture (n = 5). All patients were male with a mean age of 28.4 years (17 to 44), and had sustained injury to the leg only. Chen grade II functional status was achieved in all patients. Although the number of patients treated with each strategy was limited, there was no obvious disadvantage in the early lengthening programme, which was completed more quickly


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 3 | Pages 405 - 408
1 May 1990
Curley P Eyres K Brezinova V Allen M Chan R Barnes M

We assessed 16 patients before and after high tibial osteotomy by electrophysiological recordings, creatine phosphokinase levels, radiographs and intracompartmental pressure monitoring. We found mild electrophysiological abnormalities pre-operatively in 12 of the 16 patients, but postoperatively these had deteriorated in 11 of the 14 patients studied. Creatine phosphokinase levels, compartment pressure and radiological deformity were not predictive of the development of postoperative common peroneal nerve palsy. Patients who also had a proximal fibular osteotomy had greater electrical abnormalities postoperatively and two of them developed common peroneal palsies. Proximal fibular osteotomy appears to be a causative factor in the development of common peroneal nerve palsy; more work is needed on the blood supply of the nerve


The Journal of Bone & Joint Surgery British Volume
Vol. 64-B, Issue 4 | Pages 498 - 499
1 Aug 1982
Shakespeare D Henderson N

The effect of calcaneal traction on the compartmental pressure in the legs of five individuals with tibial fractures was studied. Mean resting pressures without traction were found to be 31.9 mmHg for the deep posterior compartment and 27.0 mmHg for the anterior compartment. For each kilogram weight of traction applied the deep posterior pressure rose by 5.7 per cent of the resting value and the anterior pressure by 1.6 per cent. It is suggested that the weight of traction should be only sufficient to render the patient comfortable and maintain alignment of the limb. Excessive traction is likely to increase the risk of compartmental ischaemia. The application of six kilograms of traction would raise the mean resting pressure by 34 per cent from 31.9 to 42.7 mmHg


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 1 | Pages 9 - 17
1 Jan 1992
Engh G Dwyer K Hanes C

We examined 86 polyethylene inserts, retrieved from total and unicompartmental knee prostheses after an average of 39.5 months in situ, grading them from 0 to 3 for seven modes of polyethylene degradation. Severe wear, with delamination or deformation, was observed in 51% of the implants, and was associated with time in situ, lack of congruency, thin polyethylene, third-body wear debris, and heat-pressed polyethylene. Significant under-surface cold flow was identified in some areas of unsupported polyethylene, and was associated with delamination in the load-bearing areas of thin inserts above screw holes in the underlying metal tray. We recommend the use of thicker polyethylene inserts, particularly in young, active patients and in designs with screw holes in the tibial baseplate. Thin polyethylene inserts which are at risk for accelerated wear and premature failure should be monitored radiographically at annual intervals


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 7 | Pages 1034 - 1036
1 Sep 2001
Rees JL Price AJ Lynskey TG Svärd UCG Dodd CAF Murray DW

Satisfactory selection criteria are essential for the successful outcome of unicompartmental knee arthroplasty (UCA). We report the frequency of revision of the Oxford medial unicompartmental arthroplasty in knees previously treated for anteromedial osteoarthritis by high tibial osteotomy (HTO). The combined results from three sources were used to allow statistical analysis of this uncommon subgroup. In the combined series of 631 knees (507 patients) which had medial unicompartmental replacement, 613 were primary procedures and 18 were for a failed HTO. The mean follow-up times of the two groups were similar (5.8 years and 5.4 years, respectively). At review, 19 (3.1%) of the primary procedures and five (27.8%) of those undertaken for a failed HTO had been revised to total knee replacement. Survival analysis revealed the ten-year cumulative survivals to be 96% and 66%, respectively. The log-rank comparison of these survivals revealed a highly significant difference (p < 0.0001). We recommend that the Oxford UCA should not be used in knees which have previously undergone an HTO


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 1 | Pages 13 - 19
1 Jan 1994
Tornetta P Bergman M Watnik N Berkowitz G Steuer J

Severe open fractures of the tibia have a high incidence of complications and a poor outcome. The most usual method of stabilisation is by external fixation, but the advent of small diameter locking intramedullary nails has introduced a new option. We report the early results of a randomised, prospective study comparing external fixation with non-reamed locked nails in grade-IIIb open tibial fractures. Of 29 patients, 15 were treated by nails and 14 by external fixation. Both groups had the same initial management, soft-tissue procedures, and early bone grafting. All 29 fractures healed within nine months, but the nailed group had slightly better motion and less final angulation. Complications included one deep infection and two pin-track infections in the external fixator group and one deep infection and one vascular problem in the nailed group. Although the differences in healing and range of motion were not statistically significant, we found that the nailed fractures were consistently easier to manage, especially in terms of soft-tissue procedures and bone grafting. It is the treatment preferred by patients and does not require the same high level of patient compliance as external fixation. The only factors against nailing are the longer operating time and the greater need for fluoroscopy. We consider that locked non-reamed nailing is the treatment of choice for grade-IIIb open tibial fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 5 | Pages 710 - 717
1 Sep 1996
Dendrinos GK Kontos S Katsenis D Dalas A

We treated 24 patients with high-energy fractures of the tibial plateau by the Ilizarov fixator and transfixion wires. Eleven fractures were open, and 20 patients had complex injuries. Twelve were treated by ligamentotaxis and percutaneous fixation, seven by limited open reduction and five by extensive open reduction. All were followed for at least 24 months. All the fractures united, with an average time to healing of 14.4 weeks. Thirteen patients achieved full extension and 13 more than 110° of flexion. Twenty-two knees were stable. Fifteen patients walked normally and the rest with only a slight limp. All but two knees had an articular step-off of less than 4 mm and all had normal axial alignment except two. There were no cases of postoperative skin infection, osteomyelitis or septic arthritis. Ilizarov circular fixation is an ideal method of treatment for these fractures when extensive dissection and internal fixation are contraindicated due to trauma to the soft tissue, deficiency of bone stock, and bony comminution


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 959 - 964
1 Nov 1998
Scheerlinck T Ng CS Handelberg F Casteleyn PP

We carried out percutaneous, arthroscopically- and fluoroscopically-assisted osteosynthesis of fractures of the tibial plateau in 52 patients, of whom 38 were assessed using the HSS knee score and standing radiographs. We reviewed 31 AO type-B fractures and seven type-C fractures after a mean follow-up of five years (1 to 14). Fixation was achieved using percutaneous screws and/or an external frame; 33 associated intra-articular injuries, diagnosed in 21 out of the 38 patients, were treated arthroscopically. Subjectively, 94.7% of the patients reviewed were satisfied. According to the HSS knee score 78.9% of the results were excellent, 13.2% good, 7.9% fair and none was poor. Narrowing of the joint space was found in 28.9% of the injured and 5.3% of the unaffected knees and axial deviation of 5° to 10° in 15.8% of the injured and 10.5% of the unaffected knees. Of the 52 fractures, reduction was incomplete in one, and in two secondary displacement occurred, of which one required corrective osteotomy. Deep-venous thrombosis occurred in four cases. The technique has proved to be safe but demanding. It facilitates diagnosis and appropriate treatment of associated intra-articular lesions


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 6 | Pages 942 - 944
1 Nov 1993
Turner R Griffiths H Heatley F

We performed postoperative venography on 84 consecutive patients who had undergone upper tibial osteotomy for medial compartment osteoarthritis of the knee. Deep-vein thrombosis was demonstrated in 41%. Only 15% of the cases were diagnosed clinically, all in the calf veins. Cases of proximal thromboses (3) and mixed-vein thromboses (12) were only revealed by venography


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 3 | Pages 412 - 417
1 May 1990
Kim Y

In 44 consecutive patients, 60 porous-coated anatomic total knee (PCA) prostheses with a porous-coated central tibial stem were implanted without using cement. The clinical results and bony remodelling have been assessed after five years' follow-up. The average Hospital for Special Surgery knee score was 33.1 before operation and 95.7 at the latest follow-up, while the average range of movement improved from 63 degrees to 123 degrees. No subsidence or migration of the components was seen. A radiodense line appeared around the components at six months to one year after the operation and became more dense with time. There was no evidence of bone resorption related to stress-shielding in the tibial plateau


The Journal of Bone & Joint Surgery British Volume
Vol. 62-B, Issue 2 | Pages 238 - 242
1 May 1980
Jakob R Haertel M Stussi E

A new method for the measurement of tibial torsion using computerised transverse tomography is presented. Its accuracy is equal to that of cadaveric skeletal measurement. This method may be used in patients with unilateral post-traumatic torsional deformities, especially when these are combined with genu varum or valgum. The study of torsional aberrations in connection with congenital abnormalities of the foot is of further interest


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 2 | Pages 195 - 198
1 Mar 1992
Triffitt P Konig D Harper W Barnes M Allen M Gregg P

We measured pressures in the anterior and deep posterior compartments continuously for up to 72 hours in 20 patients with closed fractures of the tibial shaft treated primarily in plaster casts. All were examined independently after periods of three to 14 months. Pressures above 40 mmHg occurred in seven (35%) and above 30 mmHg in 14 (70%). No patient had the symptoms of compartment syndrome during monitoring. Abnormalities at review did not correlate with the maximum consecutive time periods during which the compartment pressures were raised. Thus, in the absence of symptoms the monitored pressures did not relate to outcome. Routine monitoring in this type of patient is therefore of doubtful benefit


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 11 - 14
1 Jan 2002
Mubarak SJ

We describe six patients aged from 10 to 15 years who, after injury to the distal tibial physis, presented with the following clinical findings: 1) severe pain and swelling of the ankle; 2) hypoaesthesia or anaesthesia in the web space of the great toe; 3) weakness of extensor hallucis longus and extensor digitorum communis; and 4) pain on passive flexion of the toes, especially the great toe. In four patients, the fractures were not reduced for more than 24 hours. The intramuscular pressure beneath the superior extensor retinaculum of the ankle was greater than 40 mmHg in all cases (40 to 130 mmHg), and less than 20 mmHg in the anterior compartment. Treatment consisted of release of the superior extensor retinaculum and stabilisation of the fracture. All patients had prompt relief of pain and improved strength and sensation within 24 hours, although two had some residual numbness in the web space of the great toe


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 4 | Pages 615 - 617
1 Jul 1990
Kallio P Michelsson J Lalla M Holm T

Serial serum C-reactive protein (CRP) measurements were made, for three weeks, in 42 consecutive patients with solitary tibial fractures. The CRP response was related to the treatment: lower values were observed in 27 patients treated conservatively than in 15 operated patients. Open reduction and plating resulted in a greater response than closed intramedullary nailing. The timing of the CRP response was related to the timing of the treatment: the highest values were usually recorded two days after admission or operation. The timing of the operation did not affect the degree of CRP response. Neither the site, nor the type of fracture, nor the age of the patient played any role. Awareness of these natural CRP responses after fractures may help in the diagnosis of early post-traumatic and postoperative complications, especially infections


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 4 | Pages 529 - 534
1 Aug 1984
Hammer R Edholm P Lindholm B

The stability of union following the conservative treatment of tibial shaft fractures has been examined in 157 patients by a non-invasive method. With this technique it is possible to ascertain when the fragments are united and whether the strength of union is sufficient for full weight-bearing without protection. The mean time required for union was 14.0 +/- 9.2 weeks, with a range of 4 to 48 weeks. In 31 cases union was judged to be delayed; in 22 of these, intended operations were avoided because repeated stability determinations indicated progressive union. Of nine fracture variables examined, the only ones which significantly affected the time required to achieve union were the age and the weight of the patient. Irrelevant factors were the type and level of the fracture, the energy of trauma, soft-tissue injury and the presence of multiple injuries


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 2 | Pages 290 - 292
1 Mar 1994
Vanek J

We report a case of an apparent avulsion fracture of the posteromedial margin of the medial plateau of the tibia. This was associated with a tear of the medial meniscus and rupture of the anterior cruciate ligament (ACL). This triad has been previously reported, and the plateau fracture was related to the insertion of the semimembranosus tendon. The detailed investigation of our case and some experiments on cadaver knees showed that the injury was not an avulsion fracture but was produced by varus and external rotation forces on a flexed knee. It was due to the anterior subluxation of the medial tibial plateau after rupture of the ACL


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 4 | Pages 576 - 580
1 Aug 1985
Merianos P Cambouridis P Smyrnis P

A prospective study of 141 patients with 143 tibial shaft fractures has been carried out; 102 fractures were closed and 41 open. All the patients were treated by Ender's nailing and early weight-bearing. The average healing time was 15.2 weeks. There were no cases of bone infection and complications were minimal, the commonest being slight malalignment. Using this method, rapid restoration of bone continuity was achieved, combined with almost normal limb function during treatment


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 2 | Pages 239 - 242
1 Mar 1992
Grewal R Rimmer M Freeman M

We determined the cumulative survival rates, in arthroplasty of the knee, of three designs of tibial component, using a change of position on standard radiographs or revision for aseptic loosening as criteria of failure. The average migration of each of the three designs in the first postoperative year is known from roentgen stereophotogrammetric analysis reported by other authors. The ranking order of the components as judged by cumulative survival is the same as that determined by early migration. This finding supports the view that the measurement of early migration can predict late aseptic loosening and therefore that such measurements are clinically of value