Advertisement for orthosearch.org.uk
Results 2861 - 2880 of 6671
Results per page:
The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 774 - 778
1 Jun 2017
Agolley D Gabr A Benjamin-Laing H Haddad FS

Aims. The aim of this study was to report the outcome of the non-operative treatment of high-grade posterior cruciate ligament (PCL) injuries, particularly Hughston grade III injuries, which have not previously been described. Patients and Methods. This was a prospective study involving 46 consecutive patients who were athletes with MRI-confirmed isolated PCL injuries presenting within four weeks of injury. All had Hughston grade II (25 athletes) or III (21 athletes) injuries. Our non-operative treatment regimen involved initial bracing, followed by an individualised rehabilitation programme determined by the symptoms and physical signs. The patients were reviewed until they had returned to sports-specific training, and were reviewed again at a mean of 5.2 years (3 to 9). Results. The mean time to return to sports-specific training was 10.6 weeks and the mean time to return to full competitive sport was 16.4 weeks (10 to 40). A total of 42 patients (91.3%) were playing at the same or higher level of sport two years after the injury, with a mean Tegner activity score of 9 (5 to 10). At five years, 32 patients (69.5%) were playing at the same or higher level of sport, and 38 patients (82.6%) were playing at a competitive level, with a mean Tegner activity score of 9 (5 to 10). Conclusions. Medium-term review of a series of athletes suggests that commencing the non-operative management of isolated, Hughston grade II and III PCL injuries within four weeks of injury gives excellent functional outcomes with a high proportion returning to the same or higher level of sport. Cite this article: Bone Joint J 2017;99-B:774–8


Bone & Joint 360
Vol. 8, Issue 5 | Pages 4 - 10
1 Oct 2019
Tsoi K Samuel A Jeys LM Ashford RU Gregory JJ


Bone & Joint Research
Vol. 6, Issue 8 | Pages 499 - 505
1 Aug 2017
Morrison RJM Tsang B Fishley W Harper I Joseph JC Reed MR

Objectives. We have increased the dose of tranexamic acid (TXA) in our enhanced total joint recovery protocol at our institution from 15 mg/kg to 30 mg/kg (maximum 2.5 g) as a single, intravenous (IV) dose. We report the clinical effect of this dosage change. Methods. We retrospectively compared two cohorts of consecutive patients undergoing total hip arthroplasty (THA) or total knee arthroplasty (TKA) surgery in our unit between 2008 and 2013. One group received IV TXA 15 mg/kg, maximum 1.2 g, and the other 30 mg/kg, maximum 2.5 g as a single pre-operative dose. The primary outcome for this study was the requirement for blood transfusion within 30 days of surgery. Secondary measures included length of hospital stay, critical care requirements, re-admission rate, medical complications and mortality rates. Results. A total of 1914 THA and 2537 TKA procedures were evaluated. In THA, the higher dose of TXA was associated with a significant reduction in transfusion (p = 0.02, risk ratio (RR) 0.74, 95% confidence interval (CI) 0.58 to 0.96) and rate of re-admission (p < 0.001, RR 0.50, 95% CI 0.35 to 0.71). There were reductions in the requirement for critical care (p = 0.06, RR 0.55, 95% CI 0.31 to 1.00), and in the length of stay from 4.7 to 4.3 days (p = 0.02). In TKA, transfusion requirements (p = 0.049, RR 0.64, 95% CI 0.41 to 0.99), re-admission rate (p = 0.001, RR 0.56, 95% CI 0.39 to 0.80) and critical care requirements (p < 0.003, RR 0.34, 95% CI 0.16 to 0.72) were reduced with the higher dose. Mean length of stay reduced from 4.6 days to 3.6 days (p < 0.01). There was no difference in the incidence of deep vein thrombosis, pulmonary embolism, gastrointestinal bleed, myocardial infarction, stroke or death in THA and TKA between cohorts. Conclusion. We suggest that a single pre-operative dose of TXA, 30 mg/kg, maximum 2.5g, results in a lower transfusion requirement compared with a lower dose in patients undergoing elective primary hip and knee arthroplasty. However, these findings should be interpreted in the context of the retrospective non-randomised study design. Cite this article: R. J. M. Morrison, B. Tsang, W. Fishley, I. Harper, J. C. Joseph, M. R. Reed. Dose optimisation of intravenous tranexamic acid for elective hip and knee arthroplasty: The effectiveness of a single pre-operative dose. Bone Joint Res 2017;6:499–505. DOI: 10.1302/2046-3758.68.BJR-2017-0005.R1


Bone & Joint 360
Vol. 8, Issue 5 | Pages 16 - 19
1 Oct 2019


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1199 - 1208
1 Oct 2019
Lamb JN Matharu GS Redmond A Judge A West RM Pandit HG

Aims

We compared implant and patient survival following intraoperative periprosthetic femoral fractures (IOPFFs) during primary total hip arthroplasty (THA) with matched controls.

Patients and Methods

This retrospective cohort study compared 4831 hips with IOPFF and 48 154 propensity score matched primary THAs without IOPFF implanted between 2004 and 2016, which had been recorded on a national joint registry. Implant and patient survival rates were compared between groups using Cox regression.


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 702 - 704
1 May 2017
Haddad FS

Haefeli PC, Marecek GS, Keel MJB, Siebenrock KA, Tannast M. Patients undergoing surgical hip dislocation for the treatment of acetabular fractures show favourable long-term outcome. Bone Joint J;2017;99-B:508-515


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 78 - 80
1 Jan 2016
Lee G

Patient specific instrumentation (PSI) uses advanced imaging of the knee (CT or MRI) to generate individualised cutting blocks aimed to make the procedure of total knee arthroplasty (TKA) more accurate and efficient. However, in this era of healthcare cost consciousness, the value of new technologies needs to be critically evaluated. There have been several comparative studies looking at PSI versus standard instrumentation. Most compare PSI with conventional instrumentation in terms of alignment in the coronal plane, operative time and surgical efficiency, cost effectiveness and short-term outcomes. Several systematic reviews and meta-analyses have also been published. PSI has not been shown to be superior compared with conventional instrumentation in its ability to restore traditional mechanical alignment in primary TKA. Most studies show comparative efficacy and no decrease in the number of outliers in either group. In terms of operative time and efficiency, PSI tended towards decreasing operative time, saving a mean of five minutes per patient (0 to 20). Furthermore, while some cost savings could be realised with less operative time and reduced instrumentation per patient, these savings were overcome by the cost of the CT/MRI and the cutting blocks. Finally, there was no evidence that PSI positively affected clinical outcomes at two days, two months, or two years. Consequently, current evidence does not support routine use of PSI in routine primary TKA. Cite this article: Bone Joint J 2016;98-B(1 Suppl A):78–80


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 723 - 728
1 Jun 2015
Hamilton DF Howie CR Burnett R Simpson AHRW Patton JT

Worldwide rates of primary and revision total knee arthroplasty (TKA) are rising due to increased longevity of the population and the burden of osteoarthritis. Revision TKA is a technically demanding procedure generating outcomes which are reported to be inferior to those of primary knee arthroplasty, and with a higher risk of complication. Overall, the rate of revision after primary arthroplasty is low, but the number of patients currently living with a TKA suggests a large potential revision healthcare burden. Many patients are now outliving their prosthesis, and consideration must be given to how we are to provide the necessary capacity to meet the rising demand for revision surgery and how to maximise patient outcomes. The purpose of this review was to examine the epidemiology of, and risk factors for, revision knee arthroplasty, and to discuss factors that may enhance patient outcomes. Cite this article: Bone Joint J 2015; 97-B:723–8


Bone & Joint 360
Vol. 8, Issue 5 | Pages 33 - 35
1 Oct 2019


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 494 - 502
1 Apr 2017
Simpson AHRW Keenan G Nayagam S Atkins RM Marsh D Clement ND

Aims. The aim of this double-blind prospective randomised controlled trial was to assess whether low intensity pulsed ultrasound (LIPUS) accelerated or enhanced the rate of bone healing in adult patients undergoing distraction osteogenesis. Patients and Methods. A total of 62 adult patients undergoing limb lengthening or bone transport by distraction osteogenesis were randomised to treatment with either an active (n = 32) or a placebo (n = 30) ultrasound device. A standardised corticotomy was performed in the proximal tibial metaphysis and a circular Ilizarov frame was used in all patients. The rate of distraction was also standardised. The primary outcome measure was the time to removal of the frame after adjusting for the length of distraction in days/cm for both the per protocol (PP) and the intention-to-treat (ITT) groups. The assessor was blinded to the form of treatment. A secondary outcome was to identify covariates affecting the time to removal of the frame. Results. There was no difference in the time to removal of the frame between the PP (difference in favour of the control group was 10.1 days/cm, 95% confidence interval (CI) -3.2 to 23.4, p = 0.054) or ITT (difference 5.0 days/cm, 95% CI -8.2 to 18.21, p = 0.226) groups. The smoking status was the only covariate which increased the time to removal of the frame (hazard ratio 0.47, 95% CI 0.22 to 0.97, p = 0.042). Conclusion. LIPUS does not influence the rate of bone healing in patients who undergo distraction osteogenesis. Smoking may influence bone healing. . Cite this article: Bone Joint J 2017;99-B:494–502


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 151 - 158
1 Feb 2017
Huang T Long Y George D Wang W

Aims. There are two techniques widely used to determine the rotational alignment of the components in total knee arthroplasty (TKA); gap balancing (GB) and measured resection (MR). Which technique is the best remains controversial. We aimed to investigate this in a systematic review and meta-analysis. Materials and Methods. In accordance with the methods of Cochrane, databases were searched for all randomised controlled trials in the literature between January 1986 and June 2015 comparing radiographic and clinical outcomes between the use of these two tecniques. Meta-analysis involved the use of the Revman5.3 software provided by Cochrane collaboration. Results. A total of 1464 papers were initially identified, and after the application of rigourous inclusion and exclusion critera, eight were included in the study. In total they inolved 980 TKAs. The meta-analysis showed that GB techniques resulted in statistically significant improvements in the restoration of mechanical and rotational alignment and mean Knee Society Scores and Knee Society Function scores two years post-operatively, but resulted in greater elevation of the position of the joint line. There is no significant difference in the other radiographic data. Conclusion. This study suggests that GB may provide better radiographic and clinical outcomes than MR when used to determine mechanical rotation in TKAs. Cite this article: Bone Joint J 2017;99-B:151–8


Bone & Joint Research
Vol. 8, Issue 10 | Pages 472 - 480
1 Oct 2019
Hjorthaug GA Søreide E Nordsletten L Madsen JE Reinholt FP Niratisairak S Dimmen S

Objectives

Experimental studies indicate that non-steroidal anti-inflammatory drugs (NSAIDs) may have negative effects on fracture healing. This study aimed to assess the effect of immediate and delayed short-term administration of clinically relevant parecoxib doses and timing on fracture healing using an established animal fracture model.

Methods

A standardized closed tibia shaft fracture was induced and stabilized by reamed intramedullary nailing in 66 Wistar rats. A ‘parecoxib immediate’ (Pi) group received parecoxib (3.2 mg/kg bodyweight twice per day) on days 0, 1, and 2. A ‘parecoxib delayed’ (Pd) group received the same dose of parecoxib on days 3, 4, and 5. A control group received saline only. Fracture healing was evaluated by biomechanical tests, histomorphometry, and dual-energy x-ray absorptiometry (DXA) at four weeks.


Bone & Joint Research
Vol. 8, Issue 10 | Pages 438 - 442
1 Oct 2019
Kayani B Haddad FS


Bone & Joint Research
Vol. 8, Issue 10 | Pages 502 - 508
1 Oct 2019
Mao W Ni H Li L He Y Chen X Tang H Dong Y

Objectives

Different criteria for assessing the reduction quality of trochanteric fractures have been reported. The Baumgaertner reduction quality criteria (BRQC) are relatively common and the Chang reduction quality criteria (CRQC) are relatively new. The objectives of the current study were to compare the reliability of the BRQC and CRQC in predicting mechanical complications and to investigate the clinical implications of the CRQC.

Methods

A total of 168 patients were assessed in a retrospective observational study. Clinical information including age, sex, fracture side, American Society of Anesthesiologists (ASA) classification, tip-apex distance (TAD), fracture classification, reduction quality, blade position, BRQC, CRQC, bone quality, and the occurrence of mechanical complications were used in the statistical analysis.


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1300 - 1306
1 Oct 2019
Oliver WM Smith TJ Nicholson JA Molyneux SG White TO Clement ND Duckworth AD

Aims

The primary aim of this study was to develop a reliable, effective radiological score to assess the healing of humeral shaft fractures, the Radiographic Union Score for HUmeral fractures (RUSHU). The secondary aim was to assess whether the six-week RUSHU was predictive of nonunion at six months after the injury.

Patients and Methods

Initially, 20 patients with radiographs six weeks following a humeral shaft fracture were selected at random from a trauma database and scored by three observers, based on the Radiographic Union Scale for Tibial fractures system. After refinement of the RUSHU criteria, a second group of 60 patients with radiographs six weeks after injury, 40 with fractures that united and 20 with fractures that developed nonunion, were scored by two blinded observers.


The Bone & Joint Journal
Vol. 95-B, Issue 9 | Pages 1209 - 1216
1 Sep 2013
van der Voort P Pijls BG Nouta KA Valstar ER Jacobs WCH Nelissen RGHH

Mobile-bearing (MB) total knee replacement (TKR) was introduced to reduce the risk of aseptic loosening and wear of polyethylene inserts. However, no consistent clinical advantages of mobile- over fixed-bearing (FB) TKR have been found. In this study we evaluated whether mobile bearings have an advantage over fixed bearings with regard to revision rates and clinical outcome scores. Furthermore, we determined which modifying variables affected the outcome. A systematic search of the literature was conducted to collect clinical trials comparing MB and FB in primary TKR. The primary outcomes were revision rates for any reason, aseptic loosening and wear. Secondary outcomes included range of movement, Knee Society score (KSS), Oxford knee score (OKS), Short-Form 12 (SF-12) score and radiological parameters. Meta-regression techniques were used to explore factors modifying the observed effect. . Our search yielded 1827 publications, of which 41 studies met our inclusion criteria, comprising over 6000 TKRs. Meta-analyses showed no clinically relevant differences in terms of revision rates, clinical outcome scores or patient-reported outcome measures between MB and FB TKRs. It appears that theoretical assumptions of superiority of MB over FB TKR are not borne out in clinical practice. Cite this article: Bone Joint J 2013;95-B:1209–16


Bone & Joint 360
Vol. 8, Issue 5 | Pages 40 - 41
1 Oct 2019


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1209 - 1217
1 Oct 2019
Zeng C Lane NE Englund M Xie D Chen H Zhang Y Wang H Lei G

Aims

There is an increasing demand for hip arthroplasty in China. We aimed to describe trends in in-hospital mortality after this procedure in China and to examine the potential risk factors.

Patients and Methods

We included 210 450 patients undergoing primary hip arthroplasty registered in the Hospital Quality Monitoring System in China between 2013 and 2016. In-hospital mortality after hip arthroplasty and its relation to potential risk factors were assessed using multivariable Poisson regression.


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1459 - 1463
1 Nov 2019
Enishi T Yagi H Higuchi T Takeuchi M Sato R Yoshioka S Nakamura M Nakano S

Aims

Rotational acetabular osteotomy (RAO) is an effective joint-preserving surgical treatment for acetabular dysplasia. The purpose of this study was to investigate changes in muscle strength, gait speed, and clinical outcome in the operated hip after RAO over a one-year period using a standard protocol for rehabilitation.

Patients and Methods

A total of 57 patients underwent RAO for acetabular dysplasia. Changes in muscle strength of the operated hip, 10 m gait speed, Japanese Orthopaedic Association (JOA) hip score, and factors correlated with hip muscle strength after RAO were retrospectively analyzed.


Bone & Joint 360
Vol. 3, Issue 1 | Pages 2 - 6
1 Feb 2014
Rickert J

Patient-centred medicine is an approach to medical care that emphasises the patient experience. Treatment outcome measures reflect this experience, and outcomes are measured by obtaining patient feedback. Central to this type of care is the patient-physician relationship. Communication, physician empathy, and shared decision making are key components of this relationship. Patient-centred care is correlated with better patient outcomes across medical specialties and higher patient perceived quality of care. Payors are now using patient-centred quality measures in their physician reimbursement schedules