Advertisement for orthosearch.org.uk
Results 261 - 280 of 4027
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 3 | Pages 324 - 329
1 Mar 2008
Takeda M Higuchi H Kimura M Kobayashi Y Terauchi M Takagishi K

We prospectively examined the physical and imaging findings, including MRI, of 23 patients with spontaneous osteonecrosis of the knee after obtaining informed consent to acquire tissue specimens at surgery. There were four men and 19 women, with a mean age of 67.5 years (58 to 77). Plain radiographs were designated as stages 1, 2, 3 or 4 according to the classification of Koshino. Five knees were classified as stage 1, five as stage 2, seven as stage 3 and six as stage 4. The histological specimens were stained with haematoxylin and eosin and tetrachrome. In the early stages of the condition, a subchondral fracture was noted in the absence of any features of osteonecrosis, whereas in advanced stages, osteonecrotic lesions were confined to the area distal to the site of the fracture which showed impaired healing. In such cases, formation of cartilage and fibrous tissue, occurred indicating delayed or nonunion. These findings strongly suggest that the histopathology at each stage of spontaneous osteonecrosis is characterised by different types of repair reaction for subchondral fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 2 | Pages 195 - 198
1 Mar 2001
Walker CRC Myles C Nutton R Rowe P

We used electrogoniometers to measure the range of movement (ROM) of the knee during various activities, comparing 50 patients with osteoarthritis of the knee (OA) with 20 healthy age- and sex-matched subjects. The minimum and maximum joint angles and the ranges of excursion of the patient and control groups were tested for significant differences, using an unrelated Student’s t-test with pooled variance. Knee flexion in patients with OA was significantly reduced during all activities (p < 0.05), but differences in knee extension were not significant except when patients negotiated stairs. We believe that this reduction in ROM is caused by inhibition due to pain when load-bearing. Static non-load-bearing measurements of the ROM poorly reflected the functional ROM, with a coefficient of determination (r. 2. ) of 0.59 in the patient group and 0.60 in the control group. Electrogoniometry of the ROM of the knee provides a reliable, accurate and objective measurement of knee function


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 204 - 210
1 Feb 2017
Xu J Jia Y Kang Q Chai Y

Aims. To present our experience of using a combination of intra-articular osteotomy and external fixation to treat different deformities of the knee. Patients and Methods. A total of six patients with a mean age of 26.5 years (15 to 50) with an abnormal hemi-joint line convergence angle (HJLCA) and mechanical axis deviation (MAD) were included. Elevation of a tibial hemiplateau or femoral condylar advancement was performed and limb lengthening with correction of residual deformity using a circular or monolateral Ilizarov frame. Results. At a mean follow-up of 2.8 years (1.5 to 4.1), the mean HJLCA improved from 15.6° (10° to 23°) pre-operatively to 0.4° (0° to 2°). The mean MAD improved from 70.0 mm (20.1 to 118.5) pre-operatively to 9.1 mm (3 to 15). The mean tibiofemoral angle improved from 31.0° (8° to 54°) pre-operatively to 4.9° (2° to 8°). The mean limb-length discrepancy decreased from 6.3 cm (2.9 to 13.6) pre-operatively to 1.1 cm (0 to 5). All osteotomies and distraction zones healed without complications. Conclusion. The use of intra-articular corrective osteotomies combined with the Ilizarov technique allowed correction of deformities of the knee joint with satisfactory HJLCA and overall mechanical axis in six patients with a good functional and cosmetic outcome in the short term. Cite this article: Bone Joint J 2017;99-B:204–10


Bone & Joint 360
Vol. 7, Issue 1 | Pages 15 - 17
1 Feb 2018


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1356 - 1361
1 Oct 2012
Streit MR Walker T Bruckner T Merle C Kretzer JP Clarius M Aldinger PR Gotterbarm T

The Oxford mobile-bearing unicompartmental knee replacement (UKR) is an effective and safe treatment for osteoarthritis of the medial compartment. The results in the lateral compartment have been disappointing due to a high early rate of dislocation of the bearing. A series using a newly designed domed tibial component is reported. The first 50 consecutive domed lateral Oxford UKRs in 50 patients with a mean follow-up of three years (2.0 to 4.3) were included. Clinical scores were obtained prospectively and Kaplan-Meier survival analysis was performed for different endpoints. Radiological variables related to the position and alignment of the components were measured. One patient died and none was lost to follow-up. The cumulative incidence of dislocation was 6.2% (95% confidence interval (CI) 2.0 to 17.9) at three years. Survival using revision for any reason and aseptic revision was 94% (95% CI 82 to 98) and 96% (95% CI 85 to 99) at three years, respectively. Outcome scores, visual analogue scale for pain and maximum knee flexion showed a significant improvement (p < 0.001). The mean Oxford knee score was 43 (. sd. 5.3), the mean Objective American Knee Society score was 91 (. sd. 13.9) and the mean Functional American Knee Society score was 90 (. sd. 17.5). The mean maximum flexion was 127° (90° to 145°). Significant elevation of the lateral joint line as measured by the proximal tibial varus angle (p = 0.04) was evident in the dislocation group when compared with the non-dislocation group. Clinical results are excellent and short-term survival has improved when compared with earlier series. The risk of dislocation remains higher using a mobile-bearing UKR in the lateral compartment when compared with the medial compartment. Patients should be informed about this complication. To avoid dislocations, care must be taken not to elevate the lateral joint line.


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 786 - 792
1 Jun 2015
Hutt JRB Farhadnia P Massé V Lavigne M Vendittoli P

This randomised trial evaluated the outcome of a single design of unicompartmental arthroplasty of the knee (UKA) with either a cemented all-polyethylene or a metal-backed modular tibial component. A total of 63 knees in 45 patients (17 male, 28 female) were included, 27 in the all-polyethylene group and 36 in the metal-backed group. The mean age was 57.9 years (39.6 to 76.9). At a mean follow-up of 6.4 years (5 to 9.9), 11 all-polyethylene components (41%) were revised (at a mean of 5.8 years; 1.4 to 8.0) post-operatively and two metal-backed components were revised (at one and five years). One revision in both groups was for unexplained pain, one in the metal-backed group was for progression of osteoarthritis. The others in the all-polyethylene group were for aseptic loosening. The survivorship at seven years calculated by the Kaplan–Meier method for the all-polyethylene group was 56.5% (95% CI 31.9 to 75.2, number at risk 7) and for the metal-backed group was 93.8% (95% CI 77.3 to 98.4, number at risk 16) This difference was statistically significant (p <  0.001). At the most recent follow-up, significantly better mean Western Ontario and McMaster Universities Arthritis Index Scores were found in the all-polyethylene group (13.4 vs 23.0, p = 0.03) but there was no difference in the mean Knee injury and Osteoarthritis Outcome scores (68.8; 41.4 to 99.0 vs 62.6; 24.0 to 100.0), p = 0.36). There were no significant differences for range of movement (p = 0.36) or satisfaction (p = 0.23). This randomised study demonstrates that all-polyethylene components in this design of fixed bearing UKA had unsatisfactory results with significantly higher rates of failure before ten years compared with the metal-back components. Cite this article: Bone Joint J 2015;97-B:786–92


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1522 - 1524
1 Nov 2007
Kumagi M Ikeda S Uchida K Ono T Tsumara H

We carried out three total knee replacements with proximal realignment in two patients with severe osteoarthritis of the knee and congenital dislocation of the patella. During the operation, the femur and the tibia were cut according to the recommendations of the manufacturer of the implant. The femoral component was placed in external rotation and the centre of the tibial component aligned in relation to the tibial tuberosity with regard to rotation and translation. After making the bone cuts, the iliotibial tract was detached from Gerdy’s tubercle, the popliteus tendon divided, and the biceps femoris tendon elongated by Z-plasty. After the trial implants were positioned, a proximal re-alignment procedure was performed. One knee had deep infection. There was one dislocated patella which was repositioned, and walking ability was improved in all knees. We believe that the rotational alignment of a prosthesis is as important as the soft-tissue surgery


Bone & Joint Research
Vol. 7, Issue 5 | Pages 325 - 326
1 May 2018
Clement ND Deehan DJ


The Bone & Joint Journal
Vol. 97-B, Issue 5 | Pages 649 - 653
1 May 2015
Hawi N Kendoff D Citak M Gehrke T Haasper C

Knee arthrodesis is a potential salvage procedure for limb preservation after failure of total knee arthroplasty (TKA) due to infection. In this study, we evaluated the outcome of single-stage knee arthrodesis using an intramedullary cemented coupled nail without bone-on-bone fusion after failed and infected TKA with extensor mechanism deficiency. Between 2002 and 2012, 27 patients (ten female, 17 male; mean age 68.8 years; 52 to 87) were treated with septic single-stage exchange. Mean follow-up duration was 67.1months (24 to 143, n = 27) (minimum follow-up 24 months) and for patients with a minimum follow-up of five years 104.9 (65 to 143,; n = 13). A subjective patient evaluation (Short Form (SF)-36) was obtained, in addition to the Visual Analogue Scale (VAS). The mean VAS score was 1.44 (SD 1.48). At final follow-up, four patients had recurrent infections after arthrodesis (14.8%). Of these, three patients were treated with a one-stage arthrodesis nail exchange; one of the three patients had an aseptic loosening with a third single-stage exchange, and one patient underwent knee amputation for uncontrolled sepsis at 108 months. All patients, including the amputee, indicated that they would choose arthrodesis again. Data indicate that a single-stage knee arthrodesis offers an acceptable salvage procedure after failed and infected TKA. Cite this article: Bone Joint J 2015;97-B:649–53


The Bone & Joint Journal
Vol. 96-B, Issue 8 | Pages 1111 - 1118
1 Aug 2014
van der Heijden L Mastboom MJL Dijkstra PDS van de Sande MAJ

We retrospectively reviewed 30 patients with a diffuse-type giant-cell tumour (Dt-GCT) (previously known as pigmented villonodular synovitis) around the knee in order to assess the influence of the type of surgery on the functional outcome and quality of life (QOL). Between 1980 and 2001, 15 of these tumours had been treated primarily at our tertiary referral centre and 15 had been referred from elsewhere with recurrent lesions. The mean follow-up was 64 months (24 to 393). Functional outcome and QOL were assessed with range of movement and the Knee injury and Osteoarthritis Outcome Score (KOOS), the Musculoskeletal Tumour Society (MSTS) score, the Toronto Extremity Salvage Score (TESS) and the SF-36 questionnaire. There was recurrence in four of 14 patients treated initially by open synovectomy. Local control was achieved after a second operation in 13 of 14 (93%). Recurrence occurred in 15 of 16 patients treated initially by arthroscopic synovectomy. These patients underwent a mean of 1.8 arthroscopies (one to eight) before open synovectomy. This achieved local control in 8 of 15 (53%) after the first synovectomy and in 12 of 15 (80%) after two. The functional outcome and QOL of patients who had undergone primary arthroscopic synovectomy and its attendant subsequent surgical procedures were compared with those who had had a primary open synovectomy using the following measures: range of movement (114º versus 127º; p = 0.03); KOOS (48 versus 71; p = 0.003); MSTS (19 versus 24; p = 0.02); TESS (75 versus 86; p = 0.03); and SF-36 (62 versus 80; p = 0.01). Those who had undergone open synovectomy needed fewer subsequent operations. Most patients who had been referred with a recurrence had undergone an initial arthroscopic synovectomy followed by multiple further synovectomies. At the final follow-up of eight years (2 to 32), these patients had impaired function and QOL compared with those who had undergone open synovectomy initially. We conclude that the natural history of Dt-GCT in patients who are treated by arthroscopic synovectomy has an unfavourable outcome, and that primary open synovectomy should be undertaken to prevent recurrence or residual disease. Cite this article: Bone Joint J 2014; 96-B:1111–18


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1640 - 1644
1 Dec 2015
Dzaja I Vasarhelyi EM Lanting BA Naudie DD Howard JL Somerville L McCalden RW MacDonald SJ

The purpose of this study was to compare clinical outcomes of total knee arthroplasty (TKA) after manipulation under anaesthesia (MUA) for post-operative stiffness with a matched cohort of TKA patients who did not requre MUA. . In total 72 patients (mean age 59.8 years, 42 to 83) who underwent MUA following TKA were identified from our prospective database and compared with a matched cohort of patients who had undergone TKA without subsequent MUA. Patients were evaluated for range of movement (ROM) and clinical outcome scores (Western Ontario and McMaster Universities Arthritis Index, Short-Form Health Survey, and Knee Society Clinical Rating System) at a mean follow-up of 36.4 months (12 to 120). MUA took place at a mean of nine weeks (5 to 18) after TKA. In patients who required MUA, mean flexion deformity improved from 10° (0° to 25°) to 4.4° (0° to 15°) (p < 0.001), and mean range of flexion improved from 79.8° (65° to 95°) to 116° (80° to 130°) (p < 0.001). There were no statistically significant differences in ROM or functional outcome scores at three months, one year, or two years between those who required MUA and those who did not. There were no complications associated with manipulation. At most recent follow-up, patients requiring MUA achieved equivalent ROM and clinical outcome scores when compared with a matched control group. While other studies have focused on ROM after manipulation, the current study adds to current literature by supplementing this with functional outcome scores. Cite this article: Bone Joint J 2015;97-B:1640–4


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 901 - 903
1 Jul 2007
McDonnell SM Sinsheimer J Price AJ Carr AJ

We report a study of 112 patients with primary anteromedial osteoarthritis of the knee and their families. Sibling risk was determined using randomly selected single siblings. Spouses were used as controls. The presence of symptomatic osteoarthritis was determined using an Oxford knee score of ≥ 29 supported by a Kellgren and Lawrence radiological score of II or greater. Using Fisher’s exact test we found that there was a significant increased risk of anteromedial osteoarthritis (OA) relative to the control group (p = 0.031). The recurrence risk of anteromedial OA to siblings was 3.21 (95% confidence interval 1.12 to 9.27). These findings imply that genetic factors may play a major role in the development of anteromedial OA of the knee


Bone & Joint 360
Vol. 6, Issue 6 | Pages 17 - 20
1 Dec 2017


The Bone & Joint Journal
Vol. 97-B, Issue 4 | Pages 550 - 557
1 Apr 2015
Mollon B Lee A Busse JW Griffin AM Ferguson PC Wunder JS Theodoropoulos J

Pigmented villonodular synovitis (PVNS) is a rare proliferative process of the synovium which most commonly affects the knee and occurs in either a localised (LPVNS) or a diffuse form (DPVNS). The effect of different methods of surgical synovectomy and adjuvant radiotherapy on the rate of recurrence is unclear. We conducted a systematic review and identified 35 observational studies in English which reported the use of surgical synovectomy to treat PVNS of the knee. A meta-analysis included 630 patients, 137 (21.8%) of whom had a recurrence after synovectomy. For patients with DPVNS, low-quality evidence found that the rate of recurrence was reduced by both open synovectomy (odds ration (OR) = 0.47; 95% CI 0.25 to 0.90; p = 0.024) and combined open and arthroscopic synovectomy (OR = 0.19, 95% CI = 0.06 to 0.58; p = 0.003) compared with arthroscopic surgery. Very low-quality evidence found that the rate of recurrence of DPVNS was reduced by peri-operative radiotherapy (OR = 0.31, 95% CI 0.14 to 0.70; p = 0.01). Very low-quality evidence suggested that the rate of recurrence of LPVNS was not related to the surgical approach. . This meta-analysis suggests that open synovectomy or synovectomy combined with peri-operative radiotherapy for DPVNS is associated with a reduced rate of recurrence. Large long-term prospective multicentre observational studies, with a focus on both rate of recurrence and function, are required to confirm these findings. Cite this article: Bone Joint J 2015;97-B:550–7


Bone & Joint 360
Vol. 6, Issue 5 | Pages 12 - 16
1 Oct 2017


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 2 | Pages 327 - 330
1 Mar 1997
Poynton AR Javadpour SM Finegan PJ O’Brien M

The meniscofemoral ligaments (MFL) of the knee have both functional and clinical importance, but have been poorly described. We examined 42 human cadaver knees: there was at least one MFL in every joint and both ligaments were present in 27. The anterior MFL was present in the knees in all 18 males and in 17 of the 24 females. The posterior MFL was present in 16 males and 22 females. Measurement of the ligaments showed that they were of significant size. The mean midpoint width for the anterior MFL was 5.09 ± 1.41 mm in males and 2.99 ± 1.29 mm in females. The mean width of the posterior MFL was 5.48 ± 2.13 mm in males and 3.79 ± 2.56 mm in females. The average length of the anterior MFL was 27.09 ± 2.15 mm in males and 24.38 ± 3.39 mm in females, and the posterior MFL was 31.13 ± 2.54 mm and 27.59 ± 3.74 mm, respectively. There were anatomical variations in 16 (38%) knees (62.5% female, 37.5% male), more commonly in the posterior ligament. We conclude that the meniscofemoral ligaments are anatomically and probably functionally important structures in the human knee


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 892 - 900
1 Jul 2016
Atrey A Heylen S Gosling O Porteous MJL Haddad FS

Joint replacement of the hip and knee remain very satisfactory operations. They are, however, expensive. The actual manufacturing of the implant represents only 30% of the final cost, while sales and marketing represent 40%. Recently, the patents on many well established and successful implants have expired. Companies have started producing and distributing implants that purport to replicate existing implants with good long-term results. The aims of this paper are to assess the legality, the monitoring and cost saving implications of such generic implants. We also assess how this might affect the traditional orthopaedic implant companies. Cite this article: Bone Joint J 2016;98-B:892–900


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 11 | Pages 1441 - 1445
1 Nov 2008
Hadjicostas PT Soucacos PN Thielemann FW

We describe the mid-term results of a prospective study of total knee replacement in severe valgus knees using an osteotomy of the lateral femoral condyle and computer navigation. There were 15 knees with a mean valgus deformity of 21° (17° to 27°) and a mean follow-up of 28 months (24 to 60). A cemented, non-constrained fixed bearing, posterior-cruciate-retaining knee prosthesis of the same design was used in all cases (Columbus-B. Braun; Aesculap, Tuttlingen, Germany). All the knees were corrected to a mean of 0.5° of valgus (0° to 2°). Flexion of the knee had been limited to a mean of 85° (75° to 110°) pre-operatively and improved to a mean of 105° (90° to 130°) after operation. The mean Knee Society score improved from 37 (30 to 44) to 90 points (86 to 94). Osteotomy of the lateral femoral condyle combined with computer-assisted surgery gave an excellent mid-term outcome in patients undergoing total knee replacement in the presence of severe valgus deformity


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 241 - 248
1 Feb 2005
Pynsent PB Adams DJ Disney SP

The Oxford hip and knee scores are used to measure the outcome after primary total hip and knee replacement. We propose a new layout for the instrument in which patients are always asked about both limbs. In addition, we have defined an alternative scoring method which accounts for missing data. Over a period of 4.5 years, 4086 (1423 patients) and 5708 (1458 patients) questionnaires were completed for hips and knees, respectively. The hip score had a pre-operative median of 70.8 (interquartile range (IQR) 58.3 to 81.2) decreasing to 20.8 (IQR 10.4 to 35.4) after one year. The knee score had a pre-operative median of 68.8 (IQR 56.2 to 79.2) decreasing to 29.2 (IQR 14.6 to 45.8). There was no further significant change in either score after one year. As a result of the data analysis, we suggest that the score percentiles can be used as a standard for auditing patients before and after operation


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 5 | Pages 807 - 811
1 Nov 1987
Hoshino A Wallace W

A biomechanical study has been carried out on 20 cadaveric knees to investigate their load-absorbing mechanism. The impact load was applied using a weight falling onto the transected proximal femur and the force transmitted through the knee was measured at the transected distal tibia using a load transducer. The peak force transmitted increased as, sequentially, meniscus, articular cartilage and subchondral bone were damaged or removed. The most striking result was found in an implanted knee replacement where the transmitted force reached 180% of that in the intact knee. The results show that the joint has an impact-absorbing property in each segment and that in the osteoarthritic knee there is less absorption of shock than in the normal knee. The high impact force in an implanted knee suggests that microfractures of the cancellous bone might be expected and may produce loosening