Symptoms of obstetric brachial plexus injury (OBPI) vary widely
over the course of time and from individual to individual and can
include various degrees of denervation, muscle weakness, contractures,
bone deformities and functional limitations. To date, no universally
accepted overall framework is available to assess the outcome of patients
with OBPI. The objective of this paper is to outline the proposed
process for the development of International Classification of Functioning,
Disability and Health (ICF) Core Sets for patients with an OBPI. The first step is to conduct four preparatory studies to identify
ICF categories important for OBPI: a) a systematic literature review
to identify outcome measures, b) a qualitative study using focus
groups, c) an expert survey and d) a cross-sectional, multicentre
study. A first version of ICF Core Sets will be defined at a consensus
conference, which will integrate the evidence from the preparatory
studies. In a second step, field-testing among patients will validate this
first version of Core Sets for OBPI.Background
Methods
We investigated the effect of progesterone on the nerve during lengthening of the limb in rats. The sciatic nerves of rats were elongated by leg lengthening for ten days at 3 mm per day. On alternate days between the day after the operation and nerve dissection, the progesterone-treated group received subcutaneous injections of 1 mg progesterone in sesame oil and the control group received oil only. On the fifth, tenth and 17th day, the sciatic nerves were excised at the midpoint of the femur and the mRNA expression level of myelin protein P0 was analysed by quantitative real time polymerase chain reaction. On day 52 nodal length was examined by electron microscopy, followed by an examination of the compound muscle action potential (C-MAP) amplitude and the motor conduction velocity (MCV) of the tibial nerve on days 17 and 52. The P0 (a major myelin glycoprotein) mRNA expression level in the progesterone-treated group increased by 46.6% and 38.7% on days five and ten, respectively. On day 52, the nodal length in the progesterone-treated group was smaller than that in the control group, and the MCV of the progesterone-treated group had been restored to normal. Progesterone might accelerate the restoration of demyelination caused by nerve elongation by activating myelin synthesis.
Perilesional changes of chronic focal osteochondral defects were assessed in the knees of 23 sheep. An osteochondral defect was created in the main load-bearing region of the medial condyle of the knees in a controlled, standardised manner. The perilesional cartilage was evaluated macroscopically and biopsies were taken at the time of production of the defect (T0), during a second operation one month later (T1), and after killing animals at three (T3; n = 8), four (T4; n = 8), and seven (T7; n = 8) months. All the samples were histologically assessed by the International Cartilage Repair Society grading system and Mankin histological scores. Biopsies were taken from human patients (n = 10) with chronic articular cartilage lesions and compared with the ovine specimens. The ovine perilesional cartilage presented with macroscopic and histological signs of degeneration. At T1 the International Cartilage Repair Society ‘Subchondral Bone’ score decreased from a mean of 3.0 ( The perilesional cartilage in the animal model became chronic at one month and its histological appearance may be considered comparable with that seen in human osteochondral defects after trauma.
Clavicular fractures are occasionally responsible for lesions of the brachial plexus. The symptoms are usually delayed and due to compression by hypertrophic callus, nonunion or a subclavian pseudoaneurysm. We describe a patient in whom a displaced bone fragment was pressing on the retroclavicular part of the brachial plexus, leading to early symptoms of a lesion of the posterior cord. Internal fixation of the clavicle and external neurolysis of the brachial plexus gave an almost full recovery.
Darrach's procedure was performed for post-traumatic symptoms in the inferior radio-ulnar joint in 36 patients, who were reviewed after a mean follow-up of 6 years. Only 18 of the patients had a satisfactory clinical result. Poor outcome was associated with osteoarthritis of the wrist, the occurrence of algodystrophy and a short ulnar remnant.
Surgeons are at risk from both hepatitis B and human immunodeficiency viruses. While vaccines have been developed against the former, barrier methods remain the mainstay of protection. Puncture wounds of the hand are a potential source of contamination; the protection afforded by surgical gloves has been investigated. Gloves from 280 orthopaedic operations for trauma were tested for perforations; one or more was found after 30% of the operations in gloves worn by the surgeon or scrub nurse. About 60% of the perforations were noticed at the time of penetration and most affected the dominant thumb and index finger. Puncture was more common during operations lasting more than one hour. The incidence of perforation was 19% for the outer of double gloves, 14% for a single glove and 6% for the inner of double gloves. These results indicate that surgical gloves function poorly as a protective barrier, especially in difficult, lengthy, fracture surgery. The practice of double-gloving confers increased but not absolute protection.
1. The electric potentials in undeformed rabbit tibiae were measured 2. Surgically traumatised soft-tissues, particularly muscle, constituted the major source of voltage 3. Electrical insulation of the tibia from attached soft parts abolished the high potentials on the bone. 4. Similarly high voltages could be reproduced in an excised tibia by substituting a battery for the injured muscle. 5. Changes in voltage also could be induced by altering blood flow rates or by rapid infusion of saline into the medullary space. 6. Death of the cellular elements in bone did not alter the voltage significantly. 7. The electrical contributions of the nervous system, and of dipole components of the extracellular matrix (such as collagen), either were inconsequential or of such low magnitude as to be "masked" by the larger "injury" voltages. Supported by grants from the United States Public Health Service (AM-07822) and the National Institute of Arthritis and Metabolic Diseases (TIAM-05408).
This chamber is designed for use with conscious or unconscious patients requiring treatment with oxygen under high pressure. It can be pressurised to a maximum of 45 pounds per square inch above ambient (60 pounds per square inch absolute). The unit consists of two parts, the pressure chamber and the control console, connected together by flexible hose. The chamber can be operated up to a distance of 100 feet from the control console and both parts are mobile. The chamber consists of two concentrically mounted transparent cylinders, closed at the ends by domed metal caps. One end cap is detachable and can be removed, complete with the bed. The bed will accommodate a patient 6 feet 6 inches tall. The fully transparent chamber allows a complete view of the patient during treatment. A communication system is provided between the patient and operators. A loud speaker and microphone are built into the door of the chamber and two external pick-up points are situated on the console and the fixed end cap of the chamber. Two-way or three-way conversation is possible and the patient can be temporarily isolated from the system if required. Oxygen and electrical services must be coupled to the console. The chamber will operate directly from oxygen cylinders charged to a maximum of 1,800 pounds per square inch or from any piped supply with a minimum pressure of 75 pounds per square inch absolute. A self-contained 12-volt direct current battery supplies the necessary electrical power. A charging unit is incorporated in the control console and this is normally connected to an alternating current supply to keep the battery fully charged. If initially the battery is fully charged the unit can be operated in a continuous pressurisation-depressurisation cycle for at least twenty-four hours without further charging. Pressurisation and depressurisation are achieved by means of a motorised valve on the outlet of the pressure chamber. During pressurisation a variable speed motor applies a gradually increasing load to a helical spring. This in turn loads the outlet valve. By this means smooth pressure changes are obtained and the motor speed can be used to control the rate of pressure change. Operating the pressure chamber is simple. After the patient has been placed in the chamber and the door sealed by screw-down knobs, pressurisation is started by turning a selector switch on the control console. The required working pressure can be preset or the pressure can be held at any point between ambient and the top working pressure of 45 pounds per square inch above ambient. Pressurisation stops automatically when the preset level is reached or at 45 pounds per square inch. The rate of pressurisation is selected on the console and can be varied up to a maximum of approximately 8 pounds per square inch per minute. In the same manner, depressurisation can be controlled at any rate up to 8 pounds per square inch per minute down to ambient pressure, or held at any intermediate pressure according to the wishes of the operator. Coloured lights on the control panel indicate whether the chamber is ready for use, in the pressurisation or depressurisation state, holding a steady pressure or holding at the chosen maximum pressure. This pressure chamber is run as an open circuit. A continuous ventilating flow of oxygen passes through the chamber to wash out carbon dioxide and water vapour. In the event of an emergency affecting the patient, fast depressurisation controls are provided on both the chamber and the console. An electrically operated dumping valve can be triggered from the control console or the same valve operated manually from the end of the chamber. A pressure drop of one pound per square inch per second is obtained when this valve is used, and it is possible to reduce from maximum pressure and remove the patient from the chamber in approximately one minute. If a total power failure should occur, a manually operated, slow depressurisation valve can be opened on the control console. A number of sealed electrical plugs are provided in the door of the chamber. With suitable apparatus these allow electro-physiological monitoring of the patient throughout the course of the treatment.
1. A small mobile oxygen chamber is described which overcomes some of the disadvantages of using high pressure oxygen therapy in cases of general or local anoxia. 2. A case of limb ischaemia following an open fracture of the tibia and fibula is described in which such a method of treatment was used.
We report a case of local compression-induced transient femoral nerve palsy in a 46-year-old man. He had previously undergone surgical release of the soft tissues anterior to both hip joints because of contractures following spinal injury. An MRI scan confirmed a synovial cyst originating from the left hip joint, lying adjacent to the femoral nerve. The cyst expanded on standing, causing a transient femoral nerve palsy. The symptoms resolved after excision of the cyst.
A computer-based model of the knee was used to study forces in the cruciate ligaments induced by co-contraction of the extensor and flexor muscles, in the absence of external loads. Ligament forces are required whenever the components of the muscle forces parallel to the tibial plateau do not balance. When the extending effect of quadriceps exactly balances the flexing effect of hamstrings, the horizontal components of the two muscle forces also balance only at the critical flexion angle of 22 degrees. The calculations show that co-contraction of the quadriceps and hamstring muscles loads the anterior cruciate ligament from full extension to 22 degrees of flexion and loads the posterior cruciate at higher flexion angles. In these two regions of flexion, the forward pull of the patellar tendon on the tibia is, respectively, greater than or less than the backward pull of hamstrings. Simultaneous quadriceps and gastrocnemius contraction loads the anterior cruciate over the entire flexion range. Simultaneous contraction of all three muscle groups can unload the cruciate ligaments entirely at flexion angles above 22 degrees. These results may help the design of rational regimes of rehabilitation after ligament injury or repair.
Serial serum C-reactive protein (CRP) measurements were made, for three weeks, in 42 consecutive patients with solitary tibial fractures. The CRP response was related to the treatment: lower values were observed in 27 patients treated conservatively than in 15 operated patients. Open reduction and plating resulted in a greater response than closed intramedullary nailing. The timing of the CRP response was related to the timing of the treatment: the highest values were usually recorded two days after admission or operation. The timing of the operation did not affect the degree of CRP response. Neither the site, nor the type of fracture, nor the age of the patient played any role. Awareness of these natural CRP responses after fractures may help in the diagnosis of early post-traumatic and postoperative complications, especially infections.
Opinion varies as to the incidence of nerve lesions in anterior dislocation of the shoulder after low-velocity trauma. Most studies are retrospective or do not use EMG. We have investigated the incidence and the clinical consequences of nerve lesions in a prospective study by clinical and electrophysiological examination. Axonal loss was seen in 48% of 77 patients. The axillary nerve was most frequently involved (42%). Although recovery as judged by EMG and muscle strength was almost complete, function of the shoulder was significantly impaired in patients with lesions of the axillary and suprascapular nerves. Unfavourable prognostic factors are increasing age and the presence of a haematoma. It is not necessary to carry out EMG routinely; an adequate programme of physiotherapy is important. In patients with a severe paresis, EMG is essential after three weeks.
This work studied the fibre bundle anatomy of the anterior cruciate ligament. Three functional bundles--anteromedial, intermediate, and posterolateral--were identified in cadaver knees. Their contributions to resisting anterior subluxation in flexion and extension were found by repeated tests after sequential bundle transection. Changes of length in flexion and extension and in tibial rotation were measured. None of the fibres were isometric. The posterolateral bundle was stretched in extension and the anteromedial in flexion, which correlated with increased contributions to knee stability and the likelihood of partial ruptures in these positions. Tibial rotation had no significant effect. The fibre length changes suggested that the 'isometric point' aimed at by some ligament replacements lay anterior and superior to the femoral origin of the intermediate fibre bundle and towards the roof of the intercondylar notch.