Advertisement for orthosearch.org.uk
Results 261 - 280 of 515
Results per page:
The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 353 - 354
1 Apr 2019
Haddad FS


Bone & Joint 360
Vol. 8, Issue 1 | Pages 31 - 33
1 Feb 2019


The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 62 - 67
1 Jun 2019
Tanzer M Chuang PJ Ngo CG Song L TenHuisen KS

Aims

The purpose of this study was to evaluate the biological fixation of a 3D printed porous implant, with and without different hydroxyapatite (HA) coatings, in a canine model.

Materials and Methods

A canine transcortical model was used to evaluate the characteristics of bone ingrowth of Ti6Al4V cylindrical implants fabricated using laser rapid manufacturing (LRM). At four and 12 weeks post-implantation, we performed histological analysis and mechanical push-out testing on three groups of implants: a HA-free control (LRM), LRM with precipitated HA (LRM-PA), and LRM with plasma-sprayed HA (LRM-PSHA).


The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 16 - 22
1 Jun 2019
Livermore AT Anderson LA Anderson MB Erickson JA Peters CL

Aims

The aim of this study was to compare patient-reported outcome measures (PROMs), radiological measurements, and total hip arthroplasty (THA)-free survival in patients who underwent periacetabular osteotomy (PAO) for mild, moderate, or severe developmental dysplasia of the hip.

Patients and Methods

We performed a retrospective study involving 336 patients (420 hips) who underwent PAO by a single surgeon at an academic centre. After exclusions, 124 patients (149 hips) were included. The preoperative lateral centre-edge angle (LCEA) was used to classify the severity of dysplasia: 18° to 25° was considered mild (n = 20), 10° to 17° moderate (n = 66), and < 10° severe (n = 63). There was no difference in patient characteristics between the groups (all, p > 0.05). Pre- and postoperative radiological measurements were made. The National Institute of Health’s Patient Reported Outcomes Measurement Information System (PROMIS) outcome measures (physical function computerized adaptive test (PF CAT), Global Physical and Mental Health Scores) were collected. Failure was defined as conversion to THA or PF CAT scores < 40, and was assessed with Kaplan–Meier analysis. The mean follow-up was five years (2 to 10) ending in either failure or the latest contact with the patient.


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 207 - 212
1 Feb 2019
Clavé A Gérard R Lacroix J Baynat C Danguy des Déserts M Gatineau F Mottier D

Aims

Cementless primary total hip arthroplasty (THA) is associated with risks of bleeding and thromboembolism. Anticoagulants are effective as venous thromboprophylaxis, but with an increased risk of bleeding. Tranexamic acid (TXA) is an efficient antifibrinolytic agent, but the mode and timing of its administration remain controversial. This study aimed to determine whether two intravenous (IV) TXA regimens (a three-hour two-dose (short-TXA) and 11-hour four-dose (long-TXA)) were more effective than placebo in reducing perioperative real blood loss (RBL, between baseline and day 3 postoperatively) in patients undergoing THA who receive rivaroxaban as thromboprophylaxis. The secondary aim was to assess the non-inferiority of the reduction of blood loss of the short protocol versus the long protocol.

Patients and Methods

A multicentre, prospective, randomized, double-blind, placebo-controlled trial was undertaken involving 229 patients undergoing primary cementless THA using a posterior approach, whose extended rivaroxaban thromboprophylaxis started on the day of surgery. There were 98 male and 131 female patients, with a mean age of 65.5 years (32 to 91). The primary outcome, perioperative RBL, was evaluated at 72 hours postoperatively. The efficacy of short- and long-TXA protocols in the reduction of perioperative RBL was compared with a placebo group.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 5 | Pages 545 - 549
1 May 2008
Ashby E Grocott MPW Haddad FS

Orthopaedic outcome measures are used to evaluate the effect of operative interventions. They are used for audit and research. Knowledge of these measures is becoming increasingly important with league tables comparing surgeons and hospitals being made accessible to the profession and the general public. Several types of tool are available to describe outcome after hip surgery such as generic quality-of-life questionnaires, disease-specific quality-of-life questionnaires, hip-specific outcome measures and general short-term clinical measures. We provide an overview of the outcome measures commonly used to evaluate hip interventions


The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 84 - 90
1 Jun 2019
Charette RS Sloan M Lee G

Aims

Total hip arthroplasty (THA) is gaining popularity as a treatment for displaced femoral neck fractures (FNFs), especially in physiologically younger patients. While THA for osteoarthritis (OA) has demonstrated low complication rates and increased quality of life, results of THA for acute FNF are not as clear. Currently, a THA performed for FNF is included in an institutional arthroplasty bundle without adequate risk adjustment, potentially placing centres participating in fracture care at financial disadvantage. The purpose of this study is to report on perioperative complication rates after THA for FNF compared with elective THA performed for OA of the hip.

Patients and Methods

The American College of Surgeons National Surgical Quality Improvement Program (ACS NSQIP) database between 2008 and 2016 was queried. Patients were identified using the THA Current Procedural Terminology (CPT) code and divided into groups by diagnosis: OA in one and FNF in another. Univariate statistics were performed. Continuous variables were compared between groups using Student’s t-test, and the chi-squared test was used to compare categorical variables. Multivariate and propensity-matched logistic regression analyses were performed to control for risk factors of interest.


Bone & Joint 360
Vol. 3, Issue 1 | Pages 14 - 17
1 Feb 2014

The February 2014 Hip & Pelvis Roundup. 360 . looks at: length of stay; cementless metaphyseal fixation; mortality trends in over 400,000 total hip replacements; antibiotics in hip fracture surgery; blood supply to the femoral head after dislocation; resurfacing and THR in metal-on-metal replacement; diabetes and hip replacement; bone remodelling over two decades following hip replacement; and whether bisphosphonates affect acetabular fixation


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 92 - 95
1 Jan 2019
Harris IA Cuthbert A de Steiger R Lewis P Graves SE

Aims

Displaced femoral neck fractures (FNF) may be treated with partial (hemiarthroplasty, HA) or total hip arthroplasty (THA), with recent recommendations advising that THA be used in community-ambulant patients. This study aims to determine the association between the proportion of FNF treated with THA and year of surgery, day of the week, surgeon practice, and private versus public hospitals, adjusting for known confounders.

Patients and Methods

Data from 67 620 patients in the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) from 1999 to 2016 inclusive were used to generate unadjusted and adjusted analyses of the associations between patient, time, surgeon and institution factors, and the proportion of FNF treated with THA.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 11 | Pages 1508 - 1512
1 Nov 2006
Wimsey S Pickard R Shaw G

Magnification of anteroposterior radiographs of the pelvis is variable. To improve the accuracy of templating, reliable and radiographer-friendly methods of scaling are necessary. We assessed two methods of scaling digital radiographs of the pelvis: placing a coin of known diameter in the plane of interest between the patient’s thighs, and using a caliper to measure the bony width of the pelvis. A total of 39 patients who had recently undergone hemiarthroplasty of the hip or total hip replacement were enrolled in the study. The accuracy of the methods was assessed by comparing the actual diameter of the head of the prosthesis with the measured on-screen value. The coin method was within a mean of 1.12% (0% to 2.38%) of the actual measurement, the caliper group within 6.99% (0% to 16.67%). The coin method was significantly more accurate (p < 0.001). It was also reliable and radiographer friendly. We recommend it as the method of choice for scaling radiographs of the pelvis before hip surgery


Bone & Joint 360
Vol. 7, Issue 6 | Pages 31 - 33
1 Dec 2018


Bone & Joint 360
Vol. 7, Issue 4 | Pages 12 - 15
1 Aug 2018


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 829 - 830
1 Jul 2018
Callaghan JJ Haddad FS


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 8 | Pages 1130 - 1132
1 Nov 2001
Asano H Matsubara M Suzuki K Morita S Shinomiya K

We carried out a prospective, randomised study of 62 patients to determine the efficacy of a foot sole pump (the A-V Impulse System) for the prevention of pulmonary embolism (PE) after hip surgery. PE was assessed by pulmonary perfusion scintigraphy before and after operation. We defined a PE as any new scintigraphic defect which was larger than a bronchopulmonary segment. The incidence of PE was 55% in the control group and 21% in the treatment group. The foot sole pump significantly reduced the incidence of PE (p = 0.008) and we encountered no side-effects from its use


Bone & Joint 360
Vol. 1, Issue 3 | Pages 10 - 12
1 Jun 2012

The June 2012 Hip & Pelvis Roundup. 360. looks at: whether metal-on-metal is really such a disaster; resurfacings with unexplained pain; large heads and high ion levels; hip arthroscopy for FAI; the inaccuracy of clinical tests for impingement; arthroscopic lengthening of iliopsoas; the OA hip; the injured hamstring – football’s most common injury; an algorithm for hip fracture surgery; and sparing piriformis at THR


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 8 | Pages 1118 - 1123
1 Nov 2004
Singh S Trikha SP Edge AJ

We describe the clinical and radiological results of 38 total hip replacements (THR) using the JRI Furlong hydroxyapatite-ceramic (HAC)-coated femoral component in patients younger than 50 years. The mean age at the time of operation was 42 years (22 to 49) and the mean length of follow-up was ten years (63 to 170 months). All patients receiving a Furlong HAC THR were entered into the study regardless of the primary pathology including patients who had undergone previous hip surgery. The mean Harris hip score improved from 44 before operation to 92 at the last postoperative review. After 12 years the cumulative surivival for the stem was 100% (95% confidence interval 89 to 100). No femoral component was revised. Our results show that the Furlong HAC implant gives excellent long-term results in young patients with high demands


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1609 - 1617
1 Dec 2018
Malhas AM Granville-Chapman J Robinson PM Brookes-Fazakerley S Walton M Monga P Bale S Trail I

Aims

We present our experience of using a metal-backed prosthesis and autologous bone graft to treat gross glenoid bone deficiency.

Patients and Methods

A prospective cohort study of the first 45 shoulder arthroplasties using the SMR Axioma Trabecular Titanium (TT) metal-backed glenoid with autologous bone graft. Between May 2013 and December 2014, 45 shoulder arthroplasties were carried out in 44 patients with a mean age of 64 years (35 to 89). The indications were 23 complex primary arthroplasties, 12 to revise a hemiarthroplasty or resurfacing, five for aseptic loosening of the glenoid, and five for infection.


The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1220 - 1226
1 Sep 2018
Chiu H Chen C Su T Chen C Hsieh H Hsieh C Shen D

Aims

We aimed to determine the effect of dementia and Parkinson’s disease on one, three and 12-month mortality following surgery for fracture of the hip in elderly patients from an Asian population.

Patients and Methods

Using a random sample of patients taken from the Taiwan National Health Insurance Research Database, this retrospective cohort study analyzed the data on 6626 elderly patients who sustained a fracture of the hip between 1997 and 2012 who had ICD-9 codes within the general range of hip fracture (820.xx). We used Cox regression to estimate the risk of death associated with dementia, Parkinson’s disease or both, adjusting for demographic, clinical, treatment, and provider factors.


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1499 - 1454
1 Nov 2018
Green CM Buckley SC Hamer AJ Kerry RM Harrison TP

Aims

The management of acetabular defects at the time of revision hip arthroplasty surgery is a challenge. This study presents the results of a long-term follow-up study of the use of irradiated allograft bone in acetabular reconstruction.

Patients and Methods

Between 1990 and 2000, 123 hips in 110 patients underwent acetabular reconstruction for aseptic loosening, using impaction bone grafting with frozen, irradiated, and morsellized femoral heads and a cemented acetabular component. A total of 55 men and 55 women with a mean age of 64.3 years (26 to 97) at the time of revision surgery are included in this study.


The Journal of Bone & Joint Surgery British Volume
Vol. 51-B, Issue 1 | Pages 38 - 44
1 Feb 1969
Hunter GA

1. A review of fifty-eight posterior dislocations or fracture-dislocations of the hip is presented. 2. With few exceptions, patients were treated by immediate reduction of the dislocation under general anaesthesia, traction for six weeks and avoidance of weight-bearing for a further six weeks. 3. The results are discussed with reference to the age of the patient, length of follow-up, side affected and type of dislocation. 4. As a result ofthis review, we propose to reduce the period oftreatment in Type I dislocations (posterior dislocation without fracture) and to continue a conservative policy in respect to treatment and reconstructive hip surgery in Types II and HI fracture-dislocations